Refine
Year of publication
- 2007 (38) (remove)
Document Type
- Conference Proceeding (18)
- Article (reviewed) (4)
- Book (4)
- Part of a Book (4)
- Contribution to a Periodical (4)
- Article (unreviewed) (2)
- Periodical Part (1)
- Report (1)
Conference Type
- Konferenzartikel (13)
- Konferenz-Abstract (2)
- Konferenzband (2)
- Konferenz-Poster (1)
Is part of the Bibliography
- yes (38) (remove)
Keywords
- CDMA (2)
- Abwasser (1)
- Bioelektrochemische Brennstoffzelle (1)
- Chromatographie (1)
- Codierung (1)
- Elektrizitätserzeugung (1)
- Emission (1)
- Energietechnik (1)
- FFF (1)
- Faseroptik (1)
Institute
Open Access
- Closed Access (11)
- Open Access (9)
- Closed (8)
- Bronze (3)
A platform of an electronic capsule is being developed for multi-task medical assistant application. It includes a near field telemetry unit for bidirectional communication system of 115 KHz low carrier frequency for inductive data transmission suited for human body energy transfer. The system triggers an actuator for drug delivery in various time and release forms via wireless external control, it has the ability to record temperature, measure pH of the body (additional sensors), and retrieve data to the outside. It consists of a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA. A final layout of the complete chip design is still under progress.
A new electronic capsule with bidirectional communication system is being developed for multi-task application. The capsule is designed to be a platform for medical assistant application inside the body. The designed telemetry unit is a synchronous bidirectional communication block using continuous phase DQPSK of 115 kHz low carrier frequency for inductive data transmission suited for human body energy transfer. The communication system can assist the electronic pill to trigger an actuator for drug delivery, to record temperature, or to measure pH of the body. It consists additionally to a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA. A final layout of the complete chip design is still under progress.
To provide proper solutions to the problem of device dependant content delivery, a fine categorization of the application target devices is needed. Earlier attempts provided two different presentations for desktop and mobile platforms. The mobile platform presentation was divided into three categories, based on a general classification (PDA, Smartphone or mobile phone). In order to improve the on mobile device presentation a finer categorization is introduced. In this paper, our focus is to clarify the concept of this more flexible presentation module, in which the delivered content depends on the efficiency of the device based on a selected set of capabilities.
Electronic pills, smart capsules or miniaturized microsystems swallowed by human beings or animals for various biomedical and diagnostic applications are growing rapidly in the last years. This paper searched out the important existing electronic pills in the market and prototypes in research centers. Further objective of this research is to develop a technology platform with enhanced feature to cover the drawback of most
capsules. The designed telemetry unit is a synchronous bidirectional communication block using continuous phase DQPSK of 115 kHz low carrier frequency for inductive data transmission suited for human body energy transfer. The communication system can assist the electronic pill to trigger an actuator for drug delivery, to record temperature, or to measure pH of the body. It consists additionally to a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA.
A new, small, and optimized for low power processor core named SIRIUS has been developed, simulated, synthesized to a netlist and verified. From this netlist, containing only primitives like gates and flip-flops, a mapping to an ASIC - or FPGA technology can easily be done with existing synthesizer tools, allowing very complex SOC designs with several blocks. Emulation via FPGA can be done on already simple setups and cheap hardware because of the small core size. The performance is estimated 50 MIPS on Cyclone II FPGA and about 100 MIPS on a 0.35 CMOS 5M2P technology with 4197 primitives used for the core, including a 16 x 16 multiplier. An example design of the ASIC for an electronic ePille device currently in development is shown.
Im Rahmen dieses Projekts wurde im Labor Telekommunikationstechnik der Hochschule Offenburg ein flexibel konfigurierbares Funknetz nach dem ZigBee-Standard aufgebaut. Mit Hilfe diverser Messgeräte und Analyse-Tools wurden die wesentlichen Performance Parameter dieses Funknetzes unter realen Betriebsbedingungen evaluiert. So wurden z.B. Erkenntnisse über die Empfängerempfindlichkeit, die effektiv erreichbare Datenrate sowie das Interferenzpotential gewonnen, die Voraussetzungen für die optimale Nutzung dieser neuen Funktechnologie sind.
Soot particles emitted from a light duty (LD) Volkswagen diesel engine running at different operating points (speed and torque levels) are analyzed for mean size determination using a laser‐based three Wavelength Extinction Method (3‐WEM). For this reason, collected soot samples are suspended using an appropriate sample preparation technique with optimized conditions of sonication as it revealed its effect on the soot mean particle size measured by 3‐WEM.
An online Scanning Mobility Particle Analyzer (SMPS) is also used to measure soot emission at identical engine operating points. Size values obtained from SMPS are lower than those of suspended soot samples obtained from 3‐WEM. The size discrepancies are mainly related to the required sample preparation procedure employed for 3‐WEM measurements. The engine operating points affect, differently, the size measurements obtained from SMPS and 3‐WEM.
Sedimentation Field‐Flow Fractionation (SdFFF) is used for density determination of soot samples based on size measurements of fractions collected at peak maxima of fractograms using the off‐line hyphenation with 3‐WEM. It is assumed that a size dependent separation of soot particles occurred with a uniform particle density over the whole size distribution. An average density value is used for the conversion of soot fractograms to size distributions. Discrepancies are also found with size distribution profiles obtained from SMPS for the same engine operating points, due to the sample preparation procedure employed for SdFFF measurements.