Refine
Year of publication
Document Type
- Article (reviewed) (67) (remove)
Keywords
- Crack opening stress (2)
- Digitalisierung (2)
- Diode-array detection (2)
- Electrical Engineering (2)
- Electronic Engineering (2)
- Export (2)
- Johann Sebastian Bach (2)
- Kubelka-Munk theory (2)
- Mikrowelle (2)
- Nonlinearity (2)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (30)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (15)
- Fakultät Wirtschaft (W) (15)
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (8)
- INES - Institut für nachhaltige Energiesysteme (7)
- POIM - Peter Osypka Institute of Medical Engineering (7)
- IfTI - Institute for Trade and Innovation (4)
- CRT - Campus Research & Transfer (3)
- IBMS - Institute for Advanced Biomechanics and Motion Studies (ab 16.11.2022) (3)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (2)
Open Access
- Closed (67) (remove)
Background
To assess the in-field walking mechanics during downhill hiking of patients with total knee arthroplasty five to 14 months after surgery and an age-matched healthy control group and relate them to the knee flexor and extensor muscle strength.
Methods
Participants walked on a predetermined hiking trail at a self-selected, comfortable pace wearing an inertial sensor system for recording the whole-body 3D kinematics. Sagittal plane hip, knee, and ankle joint angles were evaluated over the gait cycle at level walking and two different negative slopes. The concentric and eccentric lower extremity muscle strength of the knee flexors and extensors isokinetically at 50 and 120°/s were measured.
Findings
Less knee flexion angles during stance have been measured in patients in the operated limb compared to healthy controls in all conditions (level walking, moderate downhill, steep downhill). The differences increased with steepness. Muscle strength was lower in patients for both muscle groups and all measured conditions. The functional hamstrings to quadriceps ratio at 120°/sec correlated with knee angle during level and downhill walking at the moderate slope in patients, showing higher ratios with lower peak knee flexion angles.
Interpretation
The study shows that even if rehabilitation has been completed successfully and complication-free, five to 14 months after surgery, the muscular condition was still insufficient to display a normal gait pattern during downhill hiking. The muscle balance between quadriceps and hamstring muscles seems related to the persistence of a stiff knee gait pattern after knee arthroplasty. LoE: III.
Purpose
This study aims to investigate a systematic approach to the production and use of additively manufactured injection mould inserts in product development (PD) processes. For this purpose, an evaluation of the additive tooling design method (ATDM) is performed.
Design/methodology/approach
The evaluation of the ATDM is conducted within student workshops, where students develop products and validate them using AT-prototypes. The evaluation process includes the analysis of work results as well as the use of questionnaires and participant observation.
Findings
This study shows that the ATDM can be successfully used to assist in producing and using AT mould inserts to produce valid AT prototypes. As a reference for the implementation of AT in industrial PD, extracts from the work of the student project groups and suitable process parameters for prototype production are presented.
Originality/value
This paper presents the application and evaluation of a method to support AT in PD that has not yet been scientifically evaluated.
Hintergrund
In diesem Artikel wird ein Überblick und Vergleich der am häufigsten verwendeten zementierten Hüftschäfte, gruppiert in die verschiedenen Schafttypen und Zementmanteldicken, gegeben, um zu sehen, welche Kombination gut abschneidet.
Methodik
Aus dem Endoprothesenregister Deutschland wurden die Revisionsraten zementierter Schaftarten kategorisiert und die Revisionsraten von 3 und 5 Jahren erfasst und analysiert. Für die Recherche lag die Konzentration auf den Schäften Exeter, C‑Stem, MS-30, Excia, Bicontact, Charnley, Müller Geradschaft, Twinsys, Corail, Avenir, Quadra und dem Lubinus SP II. Ein wichtiger Aspekt lag darin, welcher Schaft favorisiert implantiert wird und welche Zementiertechnik in Hinblick auf die geplante Zementmanteldicke angewendet wird. Um einen Trend in der zementierten Hüftendoprothetik herauszufinden, wurden zusätzlich die Daten des dänischen, schwedischen, norwegischen, schweizerischen, neuseeländischen, englischen und australischen Endoprothesenregister verglichen.
Ergebnisse und Schlussfolgerung
Die meisten Länder nutzen zementierte Prothesen nach dem Kraftschlussprinzip (Exeter, MS30, C‑Stem etc.) oder dem Formschlussprinzip (Charnley, Excia, Bicontact), welche mit einer Zementmanteldicke von 2–4 mm implantiert werden. Jedoch hat sich in Deutschland und der Schweiz ein Trend zur Line-to-Line-Technik, mit einer geplanten Zementmanteldicke von 1 mm (Twinsys, Corail, Avenir, Quadra) aufgezeigt, dem Prinzip der Müller-Geradschaft-Prothese und der Kerboul-Charnley-Prothese folgend, auch wenn diese an sich als „french paradoxon“ postuliert werden. In den EPRD-5-Jahres-Ergebnissen scheinen die neueren Line-to-Line-Prothesen etwas schlechter abzuschneiden. Die besten Ergebnisse erzielt der „MS 30“ in Deutschland und der „Exeter“ in England. Hierbei handelt es sich um polierte Geradschäfte mit Zentraliser und Subsidence-Raum an der Spitze mit einem 2–4 mm Zementmantel in guter Zementiertechnik.
Analysing and predicting the advance rate of a tunnel boring machine (TBM) in hard rock is integral to tunnelling project planning and execution. It has been applied in the industry for several decades with varying success. Most prediction models are based on or designed for large-diameter TBMs, and much research has been conducted on related tunnelling projects. However, only a few models incorporate information from projects with an outer diameter smaller than 5 m and no penetration prediction model for pipe jacking machines exists to date. In contrast to large TBMs, small-diameter TBMs and their projects have been considered little in research. In general, they are characterised by distinctive features, including insufficient geotechnical information, sometimes rather short drive lengths, special machine designs and partially concurring lining methods like pipe jacking and segment lining. A database which covers most of the parameters mentioned above has been compiled to investigate the performance of small-diameter TBMs in hard rock. In order to provide sufficient geological and technical variance, this database contains 37 projects with 70 geotechnically homogeneous areas. Besides the technical parameters, important geotechnical data like lithological information, unconfined compressive strength, tensile strength and point load index is included and evaluated. The analysis shows that segment lining TBMs have considerably higher penetration rates in similar geological and technical settings mostly due to their design parameters. Different methodologies for predicting TBM penetration, including state-of-the-art models from the literature as well as newly derived regression and machine learning models, are discussed and deployed for backward modelling of the projects contained in the database. New ranges of application for small-diameter tunnelling in several industry-standard penetration models are presented, and new approaches for the penetration prediction of pipe jacking machines in hard rock are proposed.
Physical unclonable functions (PUFs) are increasingly generating attention in the field of hardware-based security for the Internet of Things (IoT). A PUF, as its name implies, is a physical element with a special and unique inherent characteristic and can act as the security anchor for authentication and cryptographic applications. Keeping in mind that the PUF outputs are prone to change in the presence of noise and environmental variations, it is critical to derive reliable keys from the PUF and to use the maximum entropy at the same time. In this work, the PUF output positioning (POP) method is proposed, which is a novel method for grouping the PUF outputs in order to maximize the extracted entropy. To achieve this, an offset data is introduced as helper data, which is used to relax the constraints considered for the grouping of PUF outputs, and deriving more entropy, while reducing the secret key error bits. To implement the method, the key enrollment and key generation algorithms are presented. Based on a theoretical analysis of the achieved entropy, it is proven that POP can maximize the achieved entropy, while respecting the constraints induced to guarantee the reliability of the secret key. Moreover, a detailed security analysis is presented, which shows the resilience of the method against cyber-security attacks. The findings of this work are evaluated by applying the method on a hybrid printed PUF, where it can be practically shown that the proposed method outperforms other existing group-based PUF key generation methods.
In this paper, the J-integral is derived for temperature-dependent elastic–plastic materials described by incremental plasticity. It is implemented using the equivalent domain integral method for assessment of three-dimensional cracks based on results of finite-element calculations. The J-integral considers contributions from inhomogeneous temperature fields and temperature-dependent elastic and plastic material properties as well as from gradients in the plastic strains and the hardening variables. Different energy densities are considered, the Helmholtz free energy and the stress-working density, providing a physical meaning of the J-integral as a fracture criteria for crack growth. Results obtained for a plate with two different crack configurations each loaded by a cool-down thermal shock show domain-independence of the incremental J-integral for different energy densities even for high temperature gradients and significant temperature-dependence of the yield stress and the hardening exponent in the presence of large scale yielding. Hence, the derived J-integral is an appropriate parameter for the assessment of cracks in thermomechanically loaded components.
Footwear plays a critical role in our daily lives, affecting our performance, health and overall well-being. Well-designed footwear can provide protection, comfort and improved foot functionality, while poorly designed footwear can lead to mobility problems and declines in physical activity. The overall goal of footwear research is to provide a scientific basis for professionals in the field to provide an optimal footwear solution for a given person, for a given task, in a given environment, while using sustainable manufacturing processes. This article suggests potential directions for future research with a focus on athletic footwear biomechanics. Directions include the evidence-based individualisation of footwear, the interaction between design and prolonged use, and improving the sustainability of footwear. The authors also provide a speculative outlook on methodological developments that may provide greater insight into these areas. These developments may include: (1) the use of larger scale, real-world and representative data, (2) the use of 3D printing to create experimental footwear, (3) the advancement of in silico research methods, and (4) furthering multidisciplinary collaboration. If successfully applied in the future, footwear research will contribute to active and healthy lifestyles across the lifespan.
Material flow simulation is a core technology of Industry 4.0. It can analyze and improve large-scale production systems through experimentation with digital simulation models. However, modeling in discrete event simulation is considered as an effortful and time-consuming activity and challenges especially small and medium-sized enterprises. Systematic experiments and what-if-analysis require a large number of models. Modeling and simulation becomes a repetitive activity and the ability to model and simulate instantly becomes crucial for industry, 4.0. However, model generation typically uses specific methods to build models with individual properties for specific physical systems. A general literature review cannot sufficiently describe the current state of model generation. This study aims to provide an analysis of model generation based on the modeling strategy, modeling view, and production system type, as well as model properties and limitations.
International trade requires sufficient, reliable, and affordable sources of financing. Export credit agencies (ECAs) fill trade finance gaps by offering financing, insurance and guarantees to provide liquidity or mitigate risks. They help to create or secure jobs in the domestic economy. However, comprehensive government support is required to create significant impact. This includes ‘full faith and credit’ of the state. In the context of public foreign trade promotion, full faith and credit is defined as an explicit, direct or indirect, irrevocable, legal commitment to accept all liabilities of an ECA as unconditional obligations of the respective government. Our policy recommendations for countries with relatively young ECAs, for example in Ukraine, Armenia, and Malawi, are to establish a full guarantee in addition to an efficient legal set-up, sufficient capital, and sound risk management of the respective agency. Without full faith and credit, policy goals of fostering economic growth through foreign trade fall short.
Bewegungsanalysesysteme in der Forschung und für niedergelassene Orthopädinnen und Orthopäden
(2023)
Hintergrund
Komplexe biomechanische Bewegungsanalysen können für eine Vielzahl orthopädischer Fragestellungen wichtige Informationen liefern. Bei der Beschaffung von Bewegungsanalysesystemen sind neben den klassischen Messgütekriterien (Validität, Reliabilität, Objektivität) auch räumliche und zeitliche Rahmenbedingungen sowie Anforderungen an die Qualifikation des Messpersonals zu berücksichtigen.
Anwendung
In der komplexen Bewegungsanalyse werden Systeme zur Bestimmung der Kinematik, der Kinetik und der Muskelaktivität (Elektromyographie) eingesetzt. Der vorliegende Artikel gibt einen Überblick über Methoden der komplexen biomechanischen Bewegungsanalyse für den Einsatz in der orthopädischen Forschung oder in der individuellen Patientenversorgung. Neben dem Einsatz zur reinen Bewegungsanalyse wird auch der Einsatz von Bewegungsanalyseverfahren im Bereich des Biofeedbacktrainings diskutiert.
Beschaffung
Für die konkrete Anschaffung von Bewegungsanalysesystemen empfiehlt sich die Kontaktaufnahme mit Fachgesellschaften (z. B. Deutsche Gesellschaft für Biomechanik), Hochschulen und Universitäten mit vorhandenen Bewegungsanalyseeinrichtungen oder Vertriebsfirmen im Bereich der Biomechanik.