Refine
Year of publication
- 2016 (105) (remove)
Document Type
- Conference Proceeding (45)
- Article (reviewed) (30)
- Part of a Book (8)
- Bachelor Thesis (5)
- Book (5)
- Patent (4)
- Master's Thesis (3)
- Article (unreviewed) (3)
- Letter to Editor (2)
Conference Type
- Konferenzartikel (33)
- Konferenz-Abstract (7)
- Sonstiges (4)
- Konferenzband (1)
Keywords
- Eingebettetes System (5)
- Hochschule (3)
- Mathematik (3)
- Messtechnik (3)
- Radiologie (3)
- RoboCup (3)
- 6LoWPAN (2)
- Abtragung (2)
- Brennstoffzelle (2)
- Computertomografie (2)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (105) (remove)
Open Access
- Closed Access (37)
- Open Access (27)
- Bronze (7)
Energy and environment continue to be major issues of human mankind. This holds true on the regional, the national, and the global level. And it is one of the problems, where engineers and scientists in conjunction with political will and people's awareness, can find new approaches and solutions to save the natural resources and to make their use more efficient.
Diese Arbeit befasst sich mit der Konzeption und Implementierung eines Dateiimportfilters für Mess- und Kalibrierwerkzeuge. Dieser ermöglicht das Importieren von INCA-Experimenten nach CANape, indem aus Experiment-Exportdateien Konfigurationsdateien generiert werden. Im Zuge der Umsetzung wurde dazu das aus binären Daten bestehende Exportdateiformat von INCA analysiert. Das Ziel dieser Analyse bestand darin, herauszufinden, wo und wie die Informationen in den Exportdateien gespeichert sind. Die so erlangten Erkenntnisse wurden verwendet, um den Dateiimportfilter zu entwickeln. Dieser liest aus Exportdateien die notwendigen Informationen aus, überführt sie in eine CANape interne Repräsentation und generiert daraus eine entsprechende Konfigurationsdatei. Die korrekte Funktionsweise wurde anhand von selbst erstellten Experimenten sowie mithilfe von Kundenexperimenten validiert.
Components of rocket engines as actively cooled combustion chambers must withstand high pressure as well as severe and complex thermal transients. While the thermal transients result in temperature gradients and, thus, in constraint thermal strains, the pressure load induces mean stresses. To assess the mechanical behaviour of such components during design via finite-element calculations, constitutive models are necessary that describe the time- and temperature-dependent plasticity of the material appropriately.
Advanced models account for viscoplastic deformations including isotropic and kinematic hardening, recovery and ratcheting. However, the models contain a relatively large number of temperature-dependent material properties that must be determined on the basis of data of material tests. The determination of the properties is a non-trivial task because it is not clear which loading history must be applied in the tests for a certain material to obtain stable and robust (i.e. objective) material properties. Consequently, the determined properties are depending on the underlying loading history in the tests as well as on the experience and valuation of the person that determined the properties. This results in uncertainties during the assessment of the components that must be faced with conservative designs leading to negative consequences in terms of mass and costs.
It is the aim of this work funded by the European Space Agency ESA to derive a procedure to determine stable and robust material properties of an advanced viscoplastic constitutive model for aerospace materials. To this end, a special loading history is applied in isothermal material tests conducted with copper at different temperatures in the temperature range from 300 to 700 K. To determine the material properties and to assess stability and robustness methods for numerical optimization as well as analytical and statistical methods are used. The determined material properties are validated on the basis of results of thermomechanical material tests also conducted in the temperature range from 300 to 700 K.
Die Erfindung betrifft ein Verfahren zur Kalibration einer Kamera (110) unter Nutzung eines Bildschirmes (120), wobei der Bildschirm (120) eine Menge von Bildpunkten (122) aufweist und die Kamera (110) eine Vielzahl von Pixeln (112) zur Darstellung des Bildes nutzt. Das Verfahren umfasst die folgenden Schritten (a) Darstellen zumindest eines Bildwertes (BW) in zumindest einem Bildpunkt (122) des Bildschirms (120) basierend auf einer Bildwertzuweisung; (b) Erfassen des zumindest einen Bildwertes (BW) durch einen Pixel (112a) der Kamera (110); und (c) Bestimmen der Position des zumindest einen Bildpunktes (122) auf dem Bildschirm (120) basierend auf dem zumindest einen erfassten Bildwert (BW) und der Bildwertzuweisung. Das Verfahren umfasst weiter ein Verschieben des Bildschirmes (120) oder der Kamera (110) in eine Richtung um einen Betrag, sodass der zumindest eine Bildpunkt (122) eine andere Entfernung zu dem Pixel (112a) der Kamera (110) aufweist als vor dem Verschieben, und ein Wiederholen zumindest der Schritte (b) und (c) für den verschobenen Bildschirm (120i). Die Kamera (110) umfasst einen variablen Fokus beim Verschieben des Bildschirmes (120) relativ zu der Kamera (110), und das Verfahren umfasst weiter ein Abspeichern einer Zuordnung bezüglich des Pixels (112) und der Positionen des zumindest einen Bildpunktes (122) für verschiedene verschobene Bildschirmpositionen (120i).
Flexible Three-dimensional Camera-based Reconstruction and Calibration of Tracked Instruments
(2016)
Navigated instruments commonly include applied parts, e.g. burrs or saw blades, that need to be calibrated with respect to the attached or integrated tracker. Since this calibration has to be very precise, it is often performed by the manufacturer. However, due to the great variety of instruments and the option to exchange the applied parts (e.g. burrs) there is a definite demand for flexible and generic calibration techniques. Furthermore, if we look into the medical field, there is also a need for calibrating sterile instruments. We propose a new and flexible camera-based calibration technique that addresses these demands by working contactlessly, precisely, and generically for a large variety of tracked instruments. This is realized using one or more tracked cameras which are calibrated with respect to an attached or integrated tracker. The tracked instrument is rotated in front of the camera(s) and its 3D geometry and surface are reconstructed from the 2D images in the coordinate system of the attached or integrated tracker. The 3D geometry of the navigated instrument was reconstructed with an accuracy of under 0.2 mm. The radius of a sphere-shaped instrument was reconstructed with an RMS deviation of 0.015mm.