Refine
Document Type
- Conference Proceeding (29)
- Article (reviewed) (28)
- Article (unreviewed) (5)
- Part of a Book (1)
- Contribution to a Periodical (1)
Conference Type
- Konferenz-Abstract (18)
- Konferenzartikel (8)
- Konferenz-Poster (3)
Is part of the Bibliography
- yes (64) (remove)
Keywords
- injury (11)
- running (9)
- biomechanics (8)
- Biomechanik (7)
- ACL (4)
- COVID-19 (3)
- footwear (3)
- injury prevention (3)
- sport (3)
- Advanced Footwear Technology (2)
Institute
Open Access
- Open Access (44)
- Bronze (19)
- Closed (14)
- Gold (8)
- Closed Access (6)
- Hybrid (6)
- Diamond (4)
Quantifying the midsole material characteristics of athletic footwear is a standard task in footwear research and development. Current material testing protocols primarily focus on the determination of cushioning properties of the heel region or the quantification of the midsole properties as one assembly. However, midsoles possess different spatial material properties that have not been quantified from previous methodologies. Therefore, new material testing methods are required to quantify the local material response of athletic footwear. We developed a cyclical force-controlled material testing protocol for the determination of non-homogeneously distributed material stiffness with a high spatial resolution. In five prototype shoes varying in their stiffness distribution, we found that the material properties can be reliably measured across the midsole. Furthermore, we observed a characteristic non-linear material response regardless of the midsole location. We found that the material stiffness increased with an increase of the applied force and that this effect is further intensified by higher testing cycles. Additionally, the obtained midsole stiffness depends on the geometry of the midsole. We explored different approaches to reduce the measurement time of the testing protocol and found that the number of measurements can be reduced by 70% using 2 D-interpolation procedures. Determining the spatial material properties of midsoles needs to be considered to understand foot-shoe interactions. Furthermore, this measurement protocol can be used for quality control within the footwear and can be adapted for considering the effects of different running styles or speeds on ground force application characteristics.
Background:
Ankle braces aim to reduce lateral ankle sprains. Next to protection, factors influencing user compliance, such as sports performance, motion restriction, and users’ perceptions, are relevant for user compliance and thus injury prevention. Novel adaptive protection systems claim to change their mechanical behavior based on the intensity of motion (eg, the inversion velocity), unlike traditional passive concepts of ankle bracing.
Purpose:
To compare the performance of a novel adaptive brace with 2 passive ankle braces while considering protection, sports performance, freedom of motion, and subjective perception.
Study Design:
Controlled laboratory study.
Methods:
The authors analyzed 1 adaptive and 2 passive (one lace-up and one rigid brace) ankle braces, worn in a low-cut, indoor sports shoe, which was also the no-brace reference condition. We performed material testing using an artificial ankle joint system at high and low inversion velocities. Further, 20 male, young, healthy team sports athletes were analyzed using 3-dimensional motion analysis in sports-related movements to address protection, sports performance, and active range of motion dimensions. Participants rated subjective comfort, stability, and restriction experienced when using the products.
Results:
Subjective stability rating was not different between the adaptive and passive systems. The rigid brace was superior in restricting peak inversion during the biomechanical testing compared with the passive braces. However, in the material test, the adaptive brace increased its stiffness by approximately 400% during the fast compared with the slow inversion velocities, demonstrating its adaptive behavior and similar stiffness values to passive braces. We identified minor differences in sports performance tasks. The adaptive brace improved active ankle range of motion and subjective comfort and restriction ratings.
Conclusion:
The adaptive brace offered similar protective effects in high-velocity inversion situations to those of the passive braces while improving range of motion, comfort, and restriction rating during noninjurious motions.
Clinical Relevance:
Protection systems are only effective when used. Compared with traditional passive ankle brace technologies, the novel adaptive brace might increase user compliance by improving comfort and freedom of movement while offering similar protection in injurious situations.
Treadmills are essential to the study of human and animal locomotion as well as for applied diagnostics in both sports and medicine. The quantification of relevant biomechanical and physiological variables requires a precise regulation of treadmill belt velocity (TBV). Here, we present a novel method for time-efficient tracking of TBV using standard 3D motion capture technology. Further, we analyzed TBV fluctuations of four different treadmills as seven participants walked and ran at target speeds ranging from 1.0 to 4.5 m/s. Using the novel method, we show that TBV regulation differs between treadmill types, and that certain features of TBV regulation are affected by the subjects’ body mass and their locomotion speed. With higher body mass, the TBV reductions in the braking phase of stance became higher, even though this relationship differed between locomotion speeds and treadmill type (significant body mass × speed × treadmill type interaction). Average belt speeds varied between about 98 and 103% of the target speed. For three of the four treadmills, TBV reduction during the stance phase of running was more intense (> 5% target speed) and occurred earlier (before 50% of stance phase) unlike the typical overground center of mass velocity patterns reported in the literature. Overall, the results of this study emphasize the importance of monitoring TBV during locomotor research and applied diagnostics. We provide a novel method that is freely accessible on Matlab’s file exchange server (“getBeltVelocity.m”) allowing TBV tracking to become standard practice in locomotion research.
Linear acceleration is a key performance determinant and major training component of many sports. Although extensive research about lower limb kinetics and kinematics is available, consistent definitions of distinctive key body positions, the underlying mechanisms and their related movement strategies are lacking. The aim of this ‘Method and Theoretical Perspective’ article is to introduce a conceptual framework which classifies the sagittal plane ‘shin roll’ motion during accelerated sprinting. By emphasising the importance of the shin segment’s orientation in space, four distinctive key positions are presented (‘shin block’, ‘touchdown’, ‘heel lock’ and ‘propulsion pose’), which are linked by a progressive ‘shin roll’ motion during swing-stance transition. The shin’s downward tilt is driven by three different movement strategies (‘shin alignment’, ‘horizontal ankle rocker’ and ‘shin drop’). The tilt’s optimal amount and timing will contribute to a mechanically efficient acceleration via timely staggered proximal-to-distal power output. Empirical data obtained from athletes of different performance levels and sporting backgrounds are required to verify the feasibility of this concept. The framework presented here should facilitate future biomechanical analyses and may enable coaches and practitioners to develop specific training programs and feedback strategies to provide athletes with a more efficient acceleration technique.
Governments have restricted public life during the COVID-19 pandemic, inter alia closing sports facilities and gyms. As regular exercise is essential for health, this study examined the effect of pandemic-related confinements on physical activity (PA) levels. A multinational survey was performed in 14 countries. Times spent in moderate-to-vigorous physical activity (MVPA) as well as in vigorous physical activity only (VPA) were assessed using the Nordic Physical Activity Questionnaire (short form). Data were obtained for leisure and occupational PA pre- and during restrictions. Compliance with PA guidelines was calculated based on the recommendations of the World Health Organization (WHO). In total, n = 13,503 respondents (39 ± 15 years, 59% females) were surveyed. Compared to pre-restrictions, overall self-reported PA declined by 41% (MVPA) and 42.2% (VPA). Reductions were higher for occupational vs. leisure time, young and old vs. middle-aged persons, previously more active vs. less active individuals, but similar between men and women. Compared to pre-pandemic, compliance with WHO guidelines decreased from 80.9% (95% CI: 80.3–81.7) to 62.5% (95% CI: 61.6–63.3). Results suggest PA levels have substantially decreased globally during the COVID-19 pandemic. Key stakeholders should consider strategies to mitigate loss in PA in order to preserve health during the pandemic.
Background
To assess the in-field walking mechanics during downhill hiking of patients with total knee arthroplasty five to 14 months after surgery and an age-matched healthy control group and relate them to the knee flexor and extensor muscle strength.
Methods
Participants walked on a predetermined hiking trail at a self-selected, comfortable pace wearing an inertial sensor system for recording the whole-body 3D kinematics. Sagittal plane hip, knee, and ankle joint angles were evaluated over the gait cycle at level walking and two different negative slopes. The concentric and eccentric lower extremity muscle strength of the knee flexors and extensors isokinetically at 50 and 120°/s were measured.
Findings
Less knee flexion angles during stance have been measured in patients in the operated limb compared to healthy controls in all conditions (level walking, moderate downhill, steep downhill). The differences increased with steepness. Muscle strength was lower in patients for both muscle groups and all measured conditions. The functional hamstrings to quadriceps ratio at 120°/sec correlated with knee angle during level and downhill walking at the moderate slope in patients, showing higher ratios with lower peak knee flexion angles.
Interpretation
The study shows that even if rehabilitation has been completed successfully and complication-free, five to 14 months after surgery, the muscular condition was still insufficient to display a normal gait pattern during downhill hiking. The muscle balance between quadriceps and hamstring muscles seems related to the persistence of a stiff knee gait pattern after knee arthroplasty. LoE: III.
In pandemic times, the possibilities for conventional sports activities are severely limited; many sports facilities are closed or can only be used with restrictions. To counteract this lack of health activities and social exchange, people are increasingly adopting new digital sports solutions—a behavior change that had already started with the trend towards fitness apps and activity trackers. Existing research suggests that digital solutions increase the motivation to move and stay active. This work further investigates the potentials of digital sports incorporating the dimensions gender and preference for team sports versus individual sports. The study focuses on potential users, who were mostly younger professionals and academics. The results show that the SARS-CoV-19 pandemic had a significant negative impact on sports activity, particularly on persons preferring team sports. To compensate, most participants use more digital sports than before, and there is a positive correlation between the time spent physically active during the pandemic and the increase in motivation through digital sports. Nevertheless, there is still considerable skepticism regarding the potential of digital sports solutions to increase the motivation to do sports, increase performance, or raise a sense of team spirit when done in groups.
In a randomized controlled cross-over study ten male runners (26.7 ± 4.9 years; recent 5-km time: 18:37 ± 1:07 min:s) performed an incremental treadmill test (ITT) and a 3-km time trial (3-km TT) on a treadmill while wearing either carbon fiber insoles with downwards curvature or insoles made of butyl rubber (control condition) in light road racing shoes (Saucony Fastwitch 9). Oxygen uptake, respiratory exchange ratio, heart rate, blood lactate concentration, stride frequency, stride length and time to exhaustion were assessed during ITT. After ITT, all runners rated their perceived exertion, perceived shoe comfort and perceived shoe performance. Running time, heart rate, blood lactate levels, stride frequency and stride length were recorded during, and shoe comfort and shoe performance after, the 3-km TT. All parameters obtained during or after the ITT did not differ between the two conditions [range: p = 0.188 to 0.948 (alpha value: 0.05); Cohen's d = 0.021 to 0.479] despite the rating of shoe comfort showing better scores for the control insoles (p = 0.001; d = −1.646). All parameters during and after the 3-km TT showed no differences (p = 0.200 to 1.000; d = 0.000 to 0.501) between both conditions except for shoe comfort showing better scores for control insoles (p = 0.017; d = −0.919). Running with carbon fiber insoles with downwards curvature did not change running performance or any submaximal or maximal physiological or biomechanical parameter and perceived exertion compared to control condition. Shoe comfort is impaired while running with carbon fiber insoles. Wearing carbon fiber insoles with downwards curvature during treadmill running is not beneficial when compared to running with control insoles.