The Metering Bus, also known as M-Bus, is a European standard EN13757-3 for reading out metering devices, like electricity, water, gas, or heat meters. Although real-life M-Bus networks can reach a significant size and complexity, only very simple protocol analyzers are available to observe and maintain such networks. In order to provide developers and installers with the ability to analyze the real bus signals easily, a web-based monitoring tool for the M-Bus has been designed and implemented. Combined with a physical bus interface it allows for measuring and recording the bus signals. For this at first a circuit has been developed, which transforms the voltage and current-modulated M-Bus signals to a voltage signal that can be read by a standard ADC and processed by an MCU. The bus signals and packets are displayed using a web server, which analyzes and classifies the frame fragments. As an additional feature an oscilloscope functionality is included in order to visualize the physical signal on the bus. This paper describes the development of the read-out circuit for the Wired M-Bus and the data recovery.
The invention concerns a method for spectrum monitoring a given frequency band, in which the spectral power density (S(f)) within the given frequency band is determined for all noise and signal components in the frequency band and, in order to detect the presence of one or more signals within the given frequency band, it is evaluated whether the spectral power density (S(f)) exceeds a threshold value (&lgr;). According to the invention, the threshold value (&lgr;) is calculated in accordance with an estimation of a distribution density (hR(S)) for the noise component of the spectral power density (S(f)) within the given frequency band and in accordance with a predefined value for the false-alarm probability (Pfa).
Verfahren zur Bestimmung von Eigenschaften einer Rohrleitung, insbesondere der Position eines Abzweigs einer Abwasserrohrleitung, (a) bei dem ein Schallwellensendesignal (S, S') an einem vorgegebenen Einspeisepunkt in die Rohrleitung (1) eingespeist wird und sich in axialer Richtung der Rohrleitung (1) ausbreitet, (b) wobei das Frequenzspektrum des Schallwellensendesignals (S, S') eine Frequenzkomponente oder einen Spektralbereich aufweist, dessen maximale Frequenz kleiner ist als die untere Grenzfrequenz (fc) für die erste Obermode, (c) bei dem innerhalb der Rohrleitung (1) reflektierte Anteile (Sr1, Sr2, Sr3, S'r1, S'r2, S'r3) des Schallwellensendesignals (S, S') als Schallwellenempfangssignal (E, E') detektiert werden, und (d) bei dem die Rohrleitung (1) durch eine Auswertung des Schallwellenempfangssignal (E, E') in Bezug auf das Schallwellensendesignal (S, S') hinsichtlich des Vorhandenseins von Schallwellenreflexionen (Sr1, Sr2, Sr3, S'r1, S'r2, S'r3) verursachenden Reflexionsorten entlang der Rohrleitung (1) untersucht wird, (e) wobei mittels der Auswertung des Schallwellenempfangssignals (E, E') zumindest jeweils der Abstand (I) eines Reflexionsortes von dem Einspeisepunkt bestimmt wird.
Autonomous humanoid robots require light weight, high torque and high speed actuators to be able to walk and run. For conventional gears with a fixed gear ratio the product of torque and velocity is constant. On the other hand desired motions require maximum torque and speed. In this paper it is shown that with a variable gear ratio it is possible to vary the relation between torque and velocity. This is achieved by introducing systems of rods and levers to move the joints of our humanoid robot ”Sweaty II”. On the basis of a variable gear ratio low speed and high torque can be achieved for those joint angles, which require this motion mode, whereas high speed and low torque can be realized for those joint angles, where it is favorable for the desired motion.
Security in IT systems, particularly in embedded devices like Cyber Physical Systems (CPSs), has become an important matter of concern as it is the prerequisite for ensuring privacy and safety. Among a multitude of existing security measures, the Transport Layer Security (TLS) protocol family offers mature and standardized means for establishing secure communication channels over insecure transport media. In the context of classical IT infrastructure, its security with regard to protocol and implementation attacks has been subject to extensive research. As TLS protocols find their way into embedded environments, we consider the security and robustness of implementations of these protocols specifically in the light of the peculiarities of embedded systems. We present an approach for systematically checking the security and robustness of such implementations using fuzzing techniques and differential testing. In spite of its origin in testing TLS implementations we expect our approach to likewise be applicable to implementations of other cryptographic protocols with moderate efforts.
Bluetooth Low Energy extends the Bluetooth standard in version 4.0 for ultra-low energy applications through the extensive usage of low-power sleeping periods, which inherently difficult in frequency hopping technologies. This paper gives an introduction into the specifics of the Bluetooth Low Energy protocol, shows a sample implementation, where an embedded device is controlled by an Android smart phone, and shows the results of timing and current consumption measurements.
Im Projekt bwLehrpool wurde ein verteiltes System für die flexible Nutzung von Rechnerpools durch Desktop-Virtualisierung entwickelt. Auf Basis eines zentral gebooteten Linux- Grundsystems können beliebige virtualisierbare Betriebssysteme für Lehrund Prüfungszwecke zentral bereitgestellt und lokal auf den Maschinen aus-gewählt werden. Die verschiedenen Ar- beitsumgebungen müssen nicht mehr auf den PCs installiert werden und erlauben so eine multifunktionale Nutzung von PCs und Räumen für vielfältige Lehrund Lernszenarien sowie für elektronische Prüfungen. bwLehrpool abstrahiert von der PC-Hardware vor Ort und ermöglicht den Dozenten die eigene Gestaltung und Verwaltung ihrer Softwareumgebungen als Self-Service. Darüber hinaus fördert bwLehrpool den hochschulübergreifenden Austausch von Kursumgebungen.
In this paper an RFID/NFC (ISO 15693 standard) based inductively powered passive SoC (system on chip) for biomedical applications is presented. A brief overview of the system design, layout techniques and verification method is dis-cussed here. The SoC includes an integrated 32 bit microcontroller, sensor interface circuit, analog to digital converter, integrated RAM, ROM and some other peripherals required for the complete passive operation. The entire chip is realized in CMOS 0.18 μm technology with a chip area of 1.52mm x 3.24 mm.
The aim of this research work was to develop a boiler model with few parameters required for energy planning. The showcase considered for this work was the boiler system of the energy center at Offenburg University of Applied Sciences. A grey box model of the boiler was developed systematically starting from model abstraction, simplification, model break-down and to the use of empirical correlations wherever necessary to describe the intermediate effects along with the use of information from manufacturer’s specification in order to reduce parameters. This strategy had resulted in a boiler model with only 6 parameters, namely, nominal burner capacity, water gallery capacity, air ratio, heat capacity of wall, thermal conductance on flue gas and hot water side. Most of these parameters can be obtained through the information available in the spec sheets and thus an energy planner will be able to parameterize the model with low effort. The model was validated with the monitored data of the showcase. It was tested for the start-up, shut-down behavior and the effect of storage.