Refine
Year of publication
Document Type
- Article (reviewed) (116) (remove)
Language
- German (116) (remove)
Has Fulltext
- no (116) (remove)
Keywords
- Management (4)
- Biomechanik (3)
- Corporate Governance (3)
- Götz von Berlichingen (3)
- Handprothese (3)
- Johann Sebastian Bach (3)
- Regelungstechnik (3)
- Simulation (3)
- Steuerbarkeit (3)
- 3D-CAD (2)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (33)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (29)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (26)
- Fakultät Wirtschaft (W) (25)
- POIM - Peter Osypka Institute of Medical Engineering (16)
- INES - Institut für nachhaltige Energiesysteme (11)
- Fakultät Medien (M) (ab 22.04.2021) (4)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (2)
- CRT - Campus Research & Transfer (1)
- IBMS - Institute for Advanced Biomechanics and Motion Studies (ab 16.11.2022) (1)
Open Access
- Closed Access (61)
- Closed (24)
- Open Access (14)
- Diamond (4)
- Gold (1)
Der Endkundenvertrieb ist für die Bewahrung und Weiterentwicklung des Kundenstamms eines Energieversorgers essenziell. Doch um knappe Mittel im Vertrieb möglichst wirkungsvoll einsetzen zu können, wird Wissen darüber benötigt, wie sich die durchschnittlich erzielbaren Strompreise und die zu erwartende Kundenbindungsdauer zwischen verschiedenen Vertriebskanälen unterscheiden. Leitet man anhand dieser Informationen den Wert eines Kunden je Vertriebskanal ab, lässt sich treffsicherer über einzusetzende Marketing-Budgets entscheiden.
Die Hersteller von Cochlea-Implantat (CI)-Systemen sehen für klinische Audiologen die Möglichkeit vor, die Mikrofonleistung der meisten aktuellen CI-Sprachprozessoren mittels anschließbarer Monitorkopfhörer zu prüfen. Nähere Angaben dazu, nach welchem Prozedere diese Prüfung stattfinden soll, z. B. welche Stimuli mit welchen Pegeln verwendet werden sollen, sind nach Wissen der Autoren seitens der CI-Hersteller nicht verfügbar. Auf der Basis dieser subjektiven Prüfung entscheidet dann der Audiologe, ob der betreffende Sprachprozessor an den Hersteller eingeschickt wird oder nicht. Wir haben eine Messbox entwickelt, mit der die Mikrofonleistung aller abhörbaren CI-Sprachprozessoren der Hersteller Advanced Bionics, Cochlear und MED-EL objektiv geprüft werden kann. Die Box wurde im 3-D-Druckverfahren hergestellt. Der zu prüfende Sprachprozessor wird in die Messbox eingehängt und über einen verbauten Lautsprecher mit definierten Prüfsignalen (Sinustönen unterschiedlicher Frequenz) beschallt. Das Signal des Mikronfons bzw. der Mikrofone wird über das in der Audio-/Abhörbuchse des Prozessors eingesteckte Kabel der Monitorkopfhörer herausgeführt und mit einer Shifting and Scaling-Schaltung in einen Spannungsbereich transformiert, der für die A/D-Wandlung mit einem Mikrokontroller (ATmega1280 verbaut auf einem Arduino Mega) geeignet ist. Derselbe Mikrokontroller übernimmt über einen eigens gebauten D/AWandler die Ausgabe der Prüfsignale über den Lautsprecher. Signalaufnahme und –wiedergabe erfolgt jeweils mit einer Samplingrate von 38,5 kHz. Der frequenzspezifische Effektivwert des abgegriffenen Mikrofonsignals wird mit einem Referenzwert verglichen. Die (frequenzspezifischen) Referenzwerte wurden mit einem neuwertigen Sprachprozessor gleichen Typs ermittelt und im Speicher des Mikrokontrollers abgelegt. Das Ergebnis wird nach Abschluss der Messung grafisch auf einem Touchscreen ausgegeben. Derzeit läuft eine erste Datenerhebung mit in der Klinik subjektiv auffällig gewordenen CI-Sprachprozessoren, die anschließend in der Messbox untersucht werden. Längerfristiges Ziel ist es, die hit und false alarm Raten der subjektiven Prüfung zu ermitteln.
This paper presents new measurements of a bronze cast from the right hand of the famous Italian violin virtuoso Nicolò Paganini (1782-1840). These are compared to anthropometric standard values. In addition, detailed dorsal and palmar views of the cast are shown. With a middle finger length of 75 mm, the palm width is 60 mm and the hand length 152 mm, which is significantly below the 5% percentile of today's standard values. Also the finger length index (0.55), the ratio of finger length to palm length (0.98) and the ratio of finger length to palm width (1.25) are significantly above normal limits. Hence, Paganini had abnormal hand measurements with a very small palm and relatively "long" fingers. This remarkable constellation, among others, could have been advantageous for his amazing skills as a violinist.
Um Simulationen schnell und kostengünstig sowie ergebnisträchtig durchzuführen, bedarf es einer sorgfältigen Vorbereitung. Der Artikel befaßt sich mit dem automatischen Ablauf einer Simulationstudie zum Materilafluß und erläutert die im Ablauf notwendigen Beiträge der Anwender. In den Einzelheiten wird über die automatische Vorgehensweise und Anwendung der Standard-Simulationsmodelle (SSM) sowie spezieller Simulationsmodule (SimDBC) berichtet. Entscheidend für eine breitere Anwendung von Simulationswerkzeugen ist die einfache Handhabung und leicht verständliche Definition der zu untersuchenden Szenarien.
Turbinen aus der Tragetasche
(2014)
Am Karlsruher Institut für Technologie wurde der Prototyp eines Kleinwindkraftwerks zur autarken Stromversorgung entwickelt. Das "Energypack" genannte System besteht aus einem 1,10 m langen PVC-Gehäuse mit dreieckigem Querschnitt, Generator, Seilen sowie Funkgerät und kostet ab 50 Euro. Mit dem Energypack kann ein Dynamo mit 2,5 W angetrieben werden. An der Dualen Hochschule BW Heidenheim wurde das System "Anemotec" entworfen, das anstelle von Windflügeln über ein schraubenähnliches Gewinde verfügt. Der Rotor und die Windführung bestehen aus glasfaserverstärkten Werkstoffen. Die erzeugte Leistung liegt bei 365 W, die Stromgestehungskosten liegen bei 23 Cent pro kWh. Die von der Hochschule Offenburg entwickelte Windturbine "Windzip" arbeitet mit einem H-Rotor und besteht aus neun leicht gekrümmten Blechen, die wie Planeten in unterschiedlichem Abstand und in unterschiedlicher Höhe um einen vertikalen Stab kreisen. Bei einer Windgeschwindigkeit von 10 Meter pro Sekunde wurde damit eine Leistung von 40 W erzeugt.
In 35 deutschen und 7 europäischen Büro- und Verwaltungsgebäuden wurden auf Basis von Monitoringkampagnen über mehrere Betriebsjahre Raum- und Außentemperaturwerte in zeitlich hoher Auflösung erfasst und der thermische Raumkomfort im Sommer standardisiert nach der Komfortnorm DIN EN 15251:2007-08 detailliert ausgewertet. Ergänzt wird die Auswertung um Kurzzeitmesskampagnen über zwei sehr warme Wochen im Sommer in unsanierten bzw. teilsanierten Bürogebäuden, errichtet im Zeitraum von 1960 bis 1975. Die untersuchten Gebäude mit ihrem jeweiligen Kühlkonzept lassen sich in sechs Kategorien einteilen: ohne Kühlung, passive, luftgeführte und wassergeführte Kühlung sowie Mixed-mode-Kühlung und Vollklimatisierung. Im Quervergleich aller Gebäude werden die Kühlkonzepte gleichermaßen nach dem thermischen Raumkomfort und thermischen Kühlenergiebezug bewertet. Detaillierte Komfortuntersuchungen nach der Europäischen Komfortnorm DIN EN 15251:2007-08 geben Hinweise auf die Wirksamkeit der eingesetzten Kühltechnologien in den jeweiligen Klimazonen. Daraus lassen sich Handlungsempfehlungen für die Planungspraxis und den Gebäudebetrieb ableiten.