Refine
Year of publication
Document Type
- Article (reviewed) (522) (remove)
Has Fulltext
- no (522) (remove)
Is part of the Bibliography
- yes (522) (remove)
Keywords
- Dünnschichtchromatographie (17)
- Adsorption (11)
- Metallorganisches Netzwerk (9)
- Ermüdung (8)
- Lithiumbatterie (8)
- Simulation (7)
- Energieversorgung (6)
- Intelligentes Stromnetz (6)
- Plastizität (6)
- Brennstoffzelle (5)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (214)
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (135)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (74)
- INES - Institut für nachhaltige Energiesysteme (73)
- Fakultät Wirtschaft (W) (70)
- POIM - Peter Osypka Institute of Medical Engineering (17)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (13)
- IfTI - Institute for Trade and Innovation (11)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (11)
- Fakultät Medien (M) (ab 22.04.2021) (9)
Open Access
- Closed Access (242)
- Open Access (119)
- Closed (61)
- Diamond (10)
- Gold (6)
- Hybrid (5)
- Bronze (3)
- Grün (1)
Laser pulses focused near the tip of an elastic wedge generate acoustic waves guided at its apex. The shapes of the acoustic wedge wave pulses depend on the energy and the profile of the exciting laser pulse and on the anisotropy of the elastic medium the wedge is made of. Expressions for the acoustic pulse shapes have been derived in terms of the modal displacement fields of wedge waves for laser excitation in the thermo-elastic regime and for excitation via a pressure pulse exerted on the surface. The physical quantity considered is the local inclination of a surface of the wedge, which is measured optically by laser-probe-beam deflection. Experimental results on pulse shapes in the thermo-elastic regime are presented and confirmed by numerical calculations. They pertain to an isotropic sharp-angle wedge with two wedge-wave branches and to a non-reciprocity phenomenon at rectangular silicon edges.
This paper focuses on the microstructure-dependent inelastic behavior of lamellar gray cast iron. It comprises the reconstruction of three dimensional volume elements by use of the serial sectioning method for the materials GJL-150, GJL-250 and GJL-350. The obtained volume elements are prepared for the numerical analyses by means of finite-element method. In the finite-element analysis, the metallic matrix is modeled with an elastic–plastic deformation law. The graphite inclusions are modeled nonlinear elastic with a decreasing value of Young’s modulus for increasing tensile loading. Thus, the typical tension–compression asymmetry of this material class can be described. The stress–strain curves obtained with the microstructure-based finite-element models agree well with experimental curves of tension and compression tests. Besides the analysis of the whole volume element, the scatter of the stress–strain response in smaller statistical volume elements is investigated. Furthermore, numerical studies are performed to reduce computational costs.
Two closely related series of paddle-wheel-based triazolyl isophthalate MOFs are presented. Thermal and CO2 adsorption studies reveal network flexibility induced by alkyl substituents of the linker. By choice of the substituent, the pore volumes and pore diameters can be adjusted. Fine-tuning of the gate opening pressure and the hysteresis shape is possible by modulating the substitution pattern and by choice of the metal ion.
MITK-OpenIGTLink for combining open-source toolkits in real-time computer-assisted interventions
(2016)
PURPOSE:
Due to rapid developments in the research areas of medical imaging, medical image processing and robotics, computer-assisted interventions (CAI) are becoming an integral part of modern patient care. From a software engineering point of view, these systems are highly complex and research can benefit greatly from reusing software components. This is supported by a number of open-source toolkits for medical imaging and CAI such as the medical imaging interaction toolkit (MITK), the public software library for ultrasound imaging research (PLUS) and 3D Slicer. An independent inter-toolkit communication such as the open image-guided therapy link (OpenIGTLink) can be used to combine the advantages of these toolkits and enable an easier realization of a clinical CAI workflow.
METHODS:
MITK-OpenIGTLink is presented as a network interface within MITK that allows easy to use, asynchronous two-way messaging between MITK and clinical devices or other toolkits. Performance and interoperability tests with MITK-OpenIGTLink were carried out considering the whole CAI workflow from data acquisition over processing to visualization.
RESULTS:
We present how MITK-OpenIGTLink can be applied in different usage scenarios. In performance tests, tracking data were transmitted with a frame rate of up to 1000 Hz and a latency of 2.81 ms. Transmission of images with typical ultrasound (US) and greyscale high-definition (HD) resolutions of [Formula: see text] and [Formula: see text] is possible at up to 512 and 128 Hz, respectively.
CONCLUSION:
With the integration of OpenIGTLink into MITK, this protocol is now supported by all established open-source toolkits in the field. This eases interoperability between MITK and toolkits such as PLUS or 3D Slicer and facilitates cross-toolkit research collaborations. MITK and its submodule MITK-OpenIGTLink are provided open source under a BSD-style licence ( http://mitk.org )
Modeling and Simulation the Influence of Solid Carbon Formation on SOFC Performance and Degradation
(2013)
Mit der Messung des Wärme- und Kälteverbrauchs im Labor gelingt es, sowohl thermisch träge als auch agile Flächentemperiersysteme unter praxisnahen, dynamischen Bedingungen messtechnisch zu bewerten. Werden Nutzwärme- und Nutzkältebedarf berechnet und ins Verhältnis zu den gemessenen Verbräuchen gesetzt, können die Aufwandzahlen für die Nutzenübergabe ece für verschiedene Flächentemperiersysteme und in Kombinationen mit anderen Übergabesystemen unter verschiedenen Nutzungsbedingungen und für unterschiedliche Betriebsführungsstrategien bestimmt werden. Damit stehen Aufwandszahlen auf Basis kalorischer Messungen zur Verfügung, die je nach Aufgabenstellung entweder produkt- oder objektbezogen in der Planung komplexer Energiekonzepte verwendet werden können und die tatsächlichen Aufwandszahlen eh, ce für den Heizfall bzw. ec, ce für den Kühlfall genauer als Literaturwerte bzw. projektbezogen beschreiben
Cardiac resynchronization therapy is an established therapy for heart failure patients. The aim of the study was to evaluate electrical left cardiac atrioventricular delay and interventricular desynchronization in sinus rhythm cardiac resynchronization therapy responder and non-responder. Cardiac electrical desynchronization were measured by surface ECG and focused transesophageal bipolar left atrial and left ventricular ECG before implantation of cardiac resynchronization therapy defibrillators. Preoperative electrical cardiac desynchronization was 195.7 ± 46.7 ms left cardiac atrioventricular delay and 74.8 ± 24.5 ms interventricular delay in cardiac resynchronization therapy responder. Cardiac resynchronization therapy responder New York Heart Association class improved during long term biventricular pacing. Transesophageal left cardiac atrioventricular delay and interventricular delay may be additional useful parameters to improve patient selection for cardiac resynchronization therapy.
Die Namen Cormack und Hounsfield sind für den Radiologen zu einem wichtigen Synonym für die Computertomographie (CT) geworden. Der mathematische Wegbereiter für die CT, Johann Radon, kommt in der radiologischen Diskussion und den historischen Rückblicken hingegen oft zu Unrecht zu kurz. Die folgende Kurzübersicht möchte daher dem interessierten Leser die wichtigsten historischen Eckdaten zu dem in vielerlei Hinsicht bewegenden Leben und Wirken dieses großen Mathematikers näherbringen.
This is a commentary note on the situation of functional neuroimaging in psychiatry. With this we would like to encourage psychiatrists and the journal editors of psychiatric and related journals to at least rethink the role of functional neuroimaging in this discipline and use these imaging techniques in their various aspects of clinical diagnosis and therapy regimens,respectively.