Refine
Document Type
- Bachelor Thesis (4) (remove)
Language
- English (4) (remove)
Has Fulltext
- yes (4)
Is part of the Bibliography
- no (4)
Keywords
- Bewegungsabläufe (1)
- Biomechanical (1)
- Compressor (1)
- Heat transfer (1)
- Hocheffizienzfahrzeug (1)
- Leichtbau (1)
- Markerless (1)
- Markerlos (1)
- Motion Capture System (1)
- Schluckspecht (1)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (4) (remove)
Open Access
- Closed (4) (remove)
The interest of scientists to study motion sequences exists in the fields of sports science, clinical analysis and computer animation for quite some time. While in the last decades mainly markerbased motion capture systems have been used to evaluate movements, the interest in markerless systems is growing more and more. Nevertheless, in the field of clinical analysis, markerless methods have not yet proven their value, partly due to a lack of studies evaluating the quality of the obtained data. Therefore, this study aims to validate two markerless motion capture softwares from Simi Reality Motion Systems. The software Simi Shape, which is a mixture of traditional image-based tracking supported by an artificial intelligence net (AI net), and the software Crush, that uses a completely AI-based method. For this purpose, all motion data was recorded with two in-house motion capture systems. One system for recording the movements for a markerbased evaluation as gold standard and one system for markerless tracking. Within a laboratory environment, eight cameras per system were mounted around the area of motion. By placing two cameras in the same position and using the same calibration, deviations in the image data between those for markerbased and markerless tracking were extremely minimal. Based on this data, markerbased tracking was performed using the Simi Motion program, markerless tracking was performed using the Simi Shape software system and the latest software from Simi Reality Motion Systems, Crush. When comparing the markerless data with the markerbased data, an average root mean square error of 0,038 m was calculated for Simi Shape and a deviation of 0,037 m for Crush. In a direct comparison of the two markerless systems, a root mean square error of 0,019 m was scored. Based on these data, conclusions could be drawn about the accuracies of the two markerless systems. The obtained kinematic data of the tracking are in the range of high accuracy, which is limited to a deviation of less than 0,05 m according to the literature.
The present document is aimed to propose a suitable thermal model for the cooling down process of a one piston air cooled reciprocating compressor. In order to achieve this, a thermographic camera is used to record the temperature of different measuring points throughout different operating conditions. This data is later analyzed, with statistical tools and graphical visualization. The thermal phenomena present in the thermal process is characterized according to the compressors' geometry. Finally, using the analysis and taking into consideration the thermal phenomena the optimal thermal model is selected. This paper belongs to a bigger project and the last step is to simulate the compressor and the accuracy of the proposed model.
As society continues to age, the implementation of hip stems increases every year. However, there are a variety of different hip stem designs.
The aim of this project is to analyze which hip stem design implemented in a femur is most effective under different static loading conditions such as gait and sideways falling. In addition, a four-point-bending test was carried out. Therefore, the tech-niques were simulated in silico by FEA with Abaqus/CAE 2019.
A short stem, a straight stem and an anatomical stem were tested. All prosthesis are cementless press-fit stems. Each hip stem was examined in physiological and osteoporotic bone applying all three tests. To compare the stems the tests were also applied on a native bone model as a reference. Boundary conditions were used in order to simulate the tests.
The average von Mises stress, tension, compression and the risk of fracture were extracted and compared.
Biomechanical results show that the straight stem induces higher von Mises stresses compared to the anatomical stem. The risk of fracture is higher for osteo-porotic bone than for physiological bone. However, there is no risk of fracture as all the results are below the risk of value.
Schluckspecht project
(2022)