Refine
Year of publication
Document Type
- Article (reviewed) (109)
- Conference Proceeding (106)
- Contribution to a Periodical (27)
- Article (unreviewed) (12)
- Patent (8)
- Doctoral Thesis (3)
- Master's Thesis (3)
- Working Paper (2)
- Bachelor Thesis (1)
- Periodical Part (1)
Conference Type
- Konferenzartikel (62)
- Konferenz-Abstract (33)
- Sonstiges (7)
- Konferenz-Poster (5)
- Konferenzband (1)
Language
- English (272) (remove)
Keywords
- injury (9)
- RoboCup (8)
- biomechanics (8)
- running (7)
- 3D printing (6)
- Biomechanik (5)
- Chromatography (5)
- Laboratory Medicine (5)
- Monitoring/Environmental Analysis (5)
- Pharmacy (5)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (272) (remove)
Open Access
- Open Access (272) (remove)
This thesis explores the feasibility and optimization of a solar-thermal sorption system mainly designed to provide cooling but also capable of heating functionalities. Through the development of a black-box model using Python programming, the study delves into the system's performance under various operation modes. Simulation results reveal the effectiveness of adaptive control strategies and pre-heating stages in optimizing efficiency, particularly in cooling modes. In heating assessments, superior performance is observed when utilizing the outdoor coil as the heat source for the heat pump. Challenges related to operational temperature bands are addressed, proposing parallel connections of the heat pump and outdoor coil to enhance performance. Future research directions include refining regression models and incorporating real-time measurement data for improved accuracy, as well as extending simulation duration for comprehensive evaluations. This study contributes valuable insights into the system’s capabilities and applications, laying the groundwork for advancements in heat-driven integrated sustainable energy systems.
In a randomized controlled cross-over study ten male runners (26.7 ± 4.9 years; recent 5-km time: 18:37 ± 1:07 min:s) performed an incremental treadmill test (ITT) and a 3-km time trial (3-km TT) on a treadmill while wearing either carbon fiber insoles with downwards curvature or insoles made of butyl rubber (control condition) in light road racing shoes (Saucony Fastwitch 9). Oxygen uptake, respiratory exchange ratio, heart rate, blood lactate concentration, stride frequency, stride length and time to exhaustion were assessed during ITT. After ITT, all runners rated their perceived exertion, perceived shoe comfort and perceived shoe performance. Running time, heart rate, blood lactate levels, stride frequency and stride length were recorded during, and shoe comfort and shoe performance after, the 3-km TT. All parameters obtained during or after the ITT did not differ between the two conditions [range: p = 0.188 to 0.948 (alpha value: 0.05); Cohen's d = 0.021 to 0.479] despite the rating of shoe comfort showing better scores for the control insoles (p = 0.001; d = −1.646). All parameters during and after the 3-km TT showed no differences (p = 0.200 to 1.000; d = 0.000 to 0.501) between both conditions except for shoe comfort showing better scores for control insoles (p = 0.017; d = −0.919). Running with carbon fiber insoles with downwards curvature did not change running performance or any submaximal or maximal physiological or biomechanical parameter and perceived exertion compared to control condition. Shoe comfort is impaired while running with carbon fiber insoles. Wearing carbon fiber insoles with downwards curvature during treadmill running is not beneficial when compared to running with control insoles.
Batteries typically consist of multiple individual cells connected in series. Here we demonstrate single-cell state of charge (SOC) and state of health (SOH) diagnosis in a 24 V class lithium-ion battery. To this goal, we introduce and apply a novel, highly efficient algorithm based on a voltage-controlled model (VCM). The battery, consisting of eight single cells, is cycled over a duration of five months under a simple cycling protocol between 20 % and 100 % SOC. The cell-to-cell standard deviations obtained with the novel algorithm were 1.25 SOC-% and 1.07 SOH-% at beginning of cycling. A cell-averaged capacity loss of 9.9 % after five months cycling was observed. While the accuracy of single-cell SOC estimation was limited (probably owed to the flat voltage characteristics of the lithium iron phosphate, LFP, chemistry investigated here), single-cell SOH estimation showed a high accuracy (2.09 SOH-% mean absolute error compared to laboratory reference tests). Because the algorithm does not require observers, filters, or neural networks, it is computationally very efficient (three seconds analysis time for the complete data set consisting of eight cells with approx. 780.000 measurement points per cell).
Decarbonisation Strategies in Energy Systems Modelling: APV and e-tractors as Flexibility Assets
(2023)
This work presents an analysis of the impact of introducing Agrophotovoltaic technologies and electric tractors into Germany’s energy system. Agrophotovoltaics involves installing photovoltaic systems in agricultural areas, allowing for dual usage of the land for both energy generation and food production. Electric tractors, which are agricultural machinery powered by electric motors, can also function as energy storage units, providing flexibility to the grid. The analysis includes a sensitivity study to understand how the availability of agricultural land influences Agrophotovoltaic investments, followed by the examination of various scenarios that involve converting diesel tractors to electric tractors. These scenarios are based on the current CO2 emission reduction targets set by the German Government, aiming for a 65% reduction below 1990 levels by 2030 and achieving zero emissions by 2045. The results indicate that approximately 3% of available agricultural land is necessary to establish a viable energy mix in Germany. Furthermore, the expansion of electric tractors tends to reduce the overall system costs and enhances the energy-cost-efficiency of Agrophotovoltaic investments.
A wet-chemical treatment system for electrochemically coating flat substrates with coating material, has having a basin for receiving an electrolyte, a transporting means, by means of which the flat substrates can be transported through the electrolyte horizontally, and at least one contact element which comprises a shaft having an axis of rotation and a cylindrical circumferential surface suitable for rolling on the substrate, wherein the circumferential surface comprises at least one electrically insulated segment and at least one electrically conductive segment which can be connected to a current source in such a way that the polarity can be reversed, wherein the axis of rotation of the contact element is positioned above the surface of the electrolyte, and wherein the contact element is designed as a consumable electrode.
The invention relates to a device for metalising substrates. In particular, the invention relates to the field of contact elements used to electroplate solar cells within the context of a wet-chemical continuous treatment system. A wet-chemical treatment system according to the invention, for electrochemically coating flat substrates (1) with coating material, has a tank for accommodating an electrolyte, transporting means, by means of which the flat substrates (1) can be transported through the electrolyte horizontally, and at least one contact element (2), which comprises a shaft (4) having an axis of rotation (5) and a cylindrical circumferential surface suitable for rolling on the substrate (1), wherein the circumferential surface comprises at least one electrically insulating segment (3B) and at least one electrically conductive segment (3A), which can be connected to a current source (6) in such a way that the polarity can be reversed, wherein the axis of rotation (5) of the contact element (2) is positioned above the surface of the electrolyte, and wherein the contact element (2) is designed as a consumable electrode.
Variable refrigerant flow (VRF) and variable air volume (VAV) systems are considered among the best heating, ventilation, and air conditioning systems (HVAC) thanks to their ability to provide cooling and heating in different thermal zones of the same building. As well as their ability to recover the heat rejected from spaces requiring cooling and reuse it to heat another space. Nevertheless, at the same time, these systems are considered one of the most energy-consuming systems in the building. So, it is crucial to well size the system according to the building’s cooling and heating needs and the indoor temperature fluctuations. This study aims to compare these two energy systems by conducting an energy model simulation of a real building under a semi-arid climate for cooling and heating periods. The developed building energy model (BEM) was validated and calibrated using measured and simulated indoor air temperature and energy consumption data. The study aims to evaluate the effect of these HVAC systems on energy consumption and the indoor thermal comfort of the building. The numerical model was based on the Energy Plus simulation engine. The approach used in this paper has allowed us to reach significant quantitative energy saving along with a high level of indoor thermal comfort by using the VRF system compared to the VAV system. The findings prove that the VRF system provides 46.18% of the annual total heating energy savings and 6.14% of the annual cooling and ventilation energy savings compared to the VAV system.
During pyrolysis, biomass is carbonised in the absence of oxygen to produce biochar with heat and/or electricity as co-products making pyrolysis one of the promising negative emission technologies to reach climate goals worldwide. This paper presents a simplified representation of pyrolysis and analyses the impact of this technology on the energy system. Results show that the use of pyrolysis can allow getting zero emissions with lower costs by making changes in the unit commitment of the power plants, e.g. conventional power plants are used differently, as the emissions will be compensated by biochar. Additionally, the process of pyrolysis can enhance the flexibility of energy systems, as it shows a correlation between the electricity generated by pyrolysis and the hydrogen installation capacity, being hydrogen used less when pyrolysis appears. The results indicate that pyrolysis, which is available on the market, integrates well into the energy system with a promising potential to sequester carbon.