Refine
Year of publication
- 2021 (9) (remove)
Document Type
- Article (reviewed) (4)
- Letter to Editor (4)
- Part of a Book (1)
Language
- English (9) (remove)
Is part of the Bibliography
- yes (9)
Keywords
- Götz von Berlichingen (3)
- ancient Capua leg (2)
- 3D CAD (1)
- 3D computer-aided design (1)
- 3D print (1)
- 3D-light scanning (1)
- Ancient Capua leg (1)
- Christian von Mechel (1)
- Hannes hand (1)
- Second Iron Hand (1)
Institute
Open Access
- Open Access (6)
- Closed Access (3)
Background: This paper presents a conceptual design for an anthropomorphic replacement hand made of silicone that integrates a sensory feedback system. In combination with a motorized orthosis, it allows performing movements and registering information on the flexion and the pressure of the fingers.
Methods: To create the replacement hand, a three-dimensional (3D) scanner was used to scan the hand of the test person. With computer-aided design (CAD), a mold was created from the hand, then 3D-printed. Bending and force sensors were attached to the mold before silicone casting to implement the sensory feedback system. To achieve a functional and anthropomorphic appearance of the replacement hand, a material analysis was carried out. In two different test series, the properties of the used silicones were analyzed regarding their mechanical properties and the manufacturing process.
Results: Individual fingers and an entire hand with integrated sensors were realized, which demonstrated in several tests that sensory feedback in such an anthropomorphic replacement hand can be realized. Nevertheless, the choice of silicone material remains an open challenge, as there is a trade-off between the hardness of the material and the maximum mechanical force of the orthosis.
Conclusion: Apart from manufacturing-related issues, it is possible to cost-effectively create a personalized, anthropomorphic replacement hand, including sensory feedback, by using 3D scanning and 3D printing techniques.
eLetter: "The ancient Capua leg from 300 BC and the 1941 air raid on the Royal College of Surgeons"
(2021)
eLetter zum Artikel "The College of Surgeons, London", veröffentlicht in Science, Vol. 93, Issue 2425, Seite 587 (DOI: 10.1126/science.93.2425.587).
eLetter zum Artikel "Plague Through History" von Nils Chr. Stenseth, veröffentlicht in Science, Vol. 321, Issue 5890, Seite 773-774 (doi.org/10.1126/science.1161496)
eLetter zum Artikel "The Hannes hand prosthesis replicates the key biological properties of the human hand" von Matteo Laffranchi et al., veröffentlicht in Science Robotics, Vol. 5, Issue 46, eabb0467 (doi.org/10.1126/scirobotics.abb0467)
Dementia is a clinical diagnosis reflecting many possible underlying pathologies, for example, vascular dementia and neurodegenerative disorders such as frontotemporal dementia, Lewy body-type disorder or Alzheimer’s disease (AD). The breakthrough of 99mtechnetium-labelled perfusion tracers in the 1990s resulted in many SPECT studies of flow changes in AD. In the first decade of 2000, the role of perfusion SPECT was shifted from diagnosis towards differential diagnosis, parallel to the growing attention for diagnosing early stages of dementia. Previously a diagnosis based largely on a process of exclusion, new guidelines have emerged increasingly employing positive criteria to establish the diagnosis, including neuroimaging biomarkers. Nowadays, FDG PET has largely limited the role of perfusion SPECT, although it is still considered a valuable and cost-effective alternative when PET is not available.