A system for the on-line/in-line measurement of soot particle sizes and concentrations in the undiluted exhaust gas of diesel engines was developed and successfully tested. The unit uses the individual attenuations of three different laser wavelengths and is combined with an optical cell (white principle) with adjustable path lengths from 2.5 to 15 meters.
A prototype multiwavelength sensor able to characterise soot emissions in Diesel exhaust in terms of size and concentration has been tested against other methods for diesel particle measurements like electrical mobility sizing (SMPS) and raw exhaust gravimetric sampling (RES). Measurements carried out with the prototype sensor were correlated with the SMPS by assuming spherical and/or fractal aggregate morphology of the particles. Correlation of RES gravimetric data against the sensor and the SMPS led to the calculation of the solid density for soot particles to be 2.3 gr/cm3.
Time Resolved Measurements of Soot Concentrations and Mean Particle Sizes during EUDC and ECE Cycles
(2002)
Specific prototypes of sedimentation field flow fractionation devices (SdFFF) have been developed with relative success for cell sorting. However, no data are available to compare these apparatus with commercial ones. In order to compare with other devices mainly used for non-biological species, biocompatible systems were used for standard particle (latex: 3–10 μm of different size dispersities) separation development. In order to enhance size dependent separations, channels of reduced thickness were used (80 and 100 μm) and channel/carrier-phase equilibration procedures were necessary. For sample injection, the use of inlet tubing linked to the FFF accumulation wall, common for cell sorting, can be extended to latex species when they are eluted in the Steric Hyperlayer elution mode. It avoids any primary relaxation steps (stop flow injection procedure) simplifying series of elution processing. Mixtures composed of four different monodispersed latex beads can be eluted in 6 min with 100 μm channel thickness.
The three wavelength extinction method (3-WEM) was applied for the on-line particle analysisof suspensions of monodisperse latex beads and polydisperse metal oxide particles of industrialinterest. Comparative measurements were performed by photon correlation spectroscopy (PCS). Thedata of latex particles obtained by 3-WEM and PCS are in good agreement with the manufacture’svalues. Also, the values of oxide particles measured by means of the two techniques are in reasonableagreement despite of the irregular particle shape.Discrepancies are observed by comparing the oxideparticle size results with those of scanning electron microscopy, which is due to the broad sampledistributions and shape irregularities.