Refine
Year of publication
- 2012 (7) (remove)
Document Type
- Article (reviewed) (5)
- Part of a Book (1)
- Conference Proceeding (1)
Conference Type
- Konferenzartikel (1)
Language
- English (7) (remove)
Has Fulltext
- no (7)
Is part of the Bibliography
- yes (7)
Keywords
- Adsorption (3)
- Dünnschichtchromatographie (2)
- Metallorganisches Netzwerk (2)
- Ammoniumverbindungen (1)
- Belastung (1)
- Biene (1)
- Electric power production (1)
- Gas (1)
- Insektizid (1)
- Kupfer (1)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (7) (remove)
Open Access
- Closed Access (7) (remove)
Power systems are increasingly built from distributed generation units and smart consumers that are able to react to grid conditions. Managing this large number of decentralized electricity sources and flexible loads represent a very huge optimization problem. Both from the regulatory and the computational perspective, no one central coordinator can optimize this overall system. Decentralized control mechanisms can, however, distribute the optimization task through price signals or market-based mechanisms. This chapter presents the concepts that enable a decentralized control of demand and supply while enhancing overall efficiency of the electricity system. It highlights both technological and business challenges that result from the realization of these concepts, and presents the state-of-the-art in the respective domains.
Improved separation of highly toxic contact herbicides paraquat (1,1′-dimethyl-4-4′-bipyridinium), diquat (6,7-dihydrodipyridol[ 1,2-a:2′,1′-c]pyrazine-5,8-di-ium), difenzoquat (1,2-dimethyl-3,5-diphenyl-1H-pyrazolium-methyl sulfate), mepiquat (1,1-dimethyl-piperidinium), and chloromequat (2-chloroethyltrimethylammonium) were presented by high-performance thin-layer chromatography (HPTLC). The quantification is based on a derivatization reaction, using sodium tetraphenylborate. Measurements were made in the wavelength range from 500 to 535 nm, using a light-emitting diode (LED) for excitation purposes, which emits very dense light at 365 nm. For calculations, a new theory of standard addition method was used, thus leading to a minimal error if exactly the same amount of sample content is added as a standard. The method provides a fast and inexpensive approach to quantification of the five most important quats used for plant protection purposes. The method works reliably because it takes into account losses during pre-treatment procedure. The method meets the European legislation limits for paraquat and diquat in drinking water according to United States Environmental Protection Agency (US EPA) method 549.2 which are 680 ng L−1 for paraquat and 720 ng L−1 for diquat. The method of standard addition in planar chromatography can be beneficially used to reduce systematic errors. Although recovery rates of 33.7% to 65.2% are observed, calculated contents according to the method of standard addition lie between 69% and 127% of the theoretical amounts.
Pure gas adsorption isotherms of CH4 and N2 and their binary mixtures were measured at 273 K, 298 K and 323 K and up to 2 MPa on two different microporous metal–organic frameworks (MOFs), i.e. the commercially available Basolite® A100 and the recently reported copper-based triazolyl benzoate MOF 3∞[Cu(Me-4py-trz-ia)] (1). The Tòth isotherm model and the vacancy solution model were used to describe the experimentally determined isotherms and proved to be well suited for this purpose. While 1 shows a more homogeneous surface with a nearly constant isosteric heat of adsorption of 18–18.5 kJ mol−1 for CH4 and 12–15 kJ mol−1 for N2, the isosteric heat of adsorption at zero coverage for Basolite® A100 is 19 kJ mol−1 for CH4 and 16.2 kJ mol−1 for N2, decreasing significantly with increasing loading. Binary adsorption isotherms were measured gravimetrically to determine the total adsorbed mass of CH4 and N2. The van Ness method was successfully applied to calculate partial loadings from gravimetrically measured binary adsorption isotherms. Further studies by volumetric–chromatographic experiments support the good correlation between experimental data and predictions by the vacancy solution model (VSM-Wilson) and the ideal adsorbed solution theory (IAST) from pure gas isotherms. The experimental selectivities were determined to be αCH4/N2 = 4.0–5.0 for 1, slightly higher than for Basolite® A100 with αCH4/N2 = 3.4–4.5. These values are in good agreement with predictions for ideal selectivities based on Henry's law constants. From the experimental selectivities the potential of both MOFs in gas separation of CH4 from N2 can be derived.
Limits of quantification of some neonicotinoid insecticides measured by thin-layer chromatography
(2012)
A simple method to quantify the neonicotinoid insecticides nitenpyram, thiamethoxam, acetamiprid, imidacloprid, thiacloprid and clothianidin directly on an HPTLC-plate is presented. As stationary phase silica gel 60 RP-18WF254 s plates were used and a mixture of methyl-t-butyl ether, 2-butanone, NH3 (25%) (5 + 2+0.1, v/v) was used as solvent. All neonicotinoid insecticides show light absorptions below 300 nm. The calculated limits of quantification (LOQ) by UV-detection are in the range from 12 ng to 26 ng on plate depending on the different insecticides.Nitenpyram can be stained using fast blue salt B, forming red zones. The observed LOQ is 25 ng on plate. Acetamiprid can be specifically stained using phenylglyoxylic acid forming a yellow/green fluorescent compound. The LOQ is 52 ng per spot.The compounds thiamethoxam, acetamiprid, thiacloprid and clothianidin can be transformed into blue fluorescing zones, using a relatively new staining solution. This consists of tetraphenylborate and HCl. This is the first publication mentioning that neonicotinoids undergo this reaction. The calculated limits of quantification are in the range from 10 ng to 27 ng on plate.A simple pre-treatment procedure using an acetonitrile extraction and a Chromabond SiOH clean up procedure leads to overall LOQs for bee samples of 48 to 108 µg/Kg. The method can be used to measure neonicotinoid contaminations of bees.
An isomorphous series of 10 microporous copper-based metal–organic frameworks (MOFs) with the general formulas ∞3[{Cu3(μ3-OH)(X)}4{Cu2(H2O)2}3(H-R-trz-ia)12] (R = H, CH3, Ph; X2– = SO42–, SeO42–, 2 NO32– (1–8)) and ∞3[{Cu3(μ3-OH)(X)}8{Cu2(H2O)2}6(H-3py-trz-ia)24Cu6]X3 (R = 3py; X2– = SO42–, SeO42– (9, 10)) is presented together with the closely related compounds ∞3[Cu6(μ4-O)(μ3-OH)2(H-Metrz-ia)4][Cu(H2O)6](NO3)2·10H2O (11) and ∞3[Cu2(H-3py-trz-ia)2(H2O)3] (12Cu), which are obtained under similar reaction conditions. The porosity of the series of cubic MOFs with twf-d topology reaches up to 66%. While the diameters of the spherical pores remain unaffected, adsorption measurements show that the pore volume can be fine-tuned by the substituents of the triazolyl isophthalate ligand and choice of the respective copper salt, that is, copper sulfate, selenate, or nitrate.
As a basis for the evaluation of hydrogen storage by physisorption, adsorption isotherms of H2 were experimentally determined for several porous materials at 77 K and 298 K at pressures up to 15 MPa. Activated carbons and MOFs were studied as the most promising materials for this purpose. A noble focus was given on how to determine whether a material is feasible for hydrogen storage or not, dealing with an assessment method and the pitfalls and problems of determining the viability. For a quantitative evaluation of the feasibility of sorptive hydrogen storage in a general analysis, it is suggested to compare the stored amount in a theoretical tank filled with adsorbents to the amount of hydrogen stored in the same tank without adsorbents. According to our results, an “ideal” sorbent for hydrogen storage at 77 K is calculated to exhibit a specific surface area of >2580 m2 g−1 and a micropore volume of >1.58 cm3 g−1.
The provisioning of security for highly dynamic wireless networks, as for Car2X applications is still a major topic, as very specific requirements have to be solved. Those include a perfect privacy level and advanced real-time behavior, and the necessity to work with a public infrastructure (PKI) to support secure authentication.
This contribution analyzes these requirements, discusses the existing approaches, performs a gap analysis and elaborates on proposals to fill these gaps. It describes work in progress within the KoFAS-initiative for the development of a cooperative pedestrian protection system (CPPS).