Refine
Year of publication
Document Type
- Article (reviewed) (67)
- Conference Proceeding (6)
- Book (1)
- Article (unreviewed) (1)
Conference Type
- Konferenzartikel (6)
Language
- English (75) (remove)
Keywords
- 3D printing (5)
- neuroprosthetics (5)
- Götz von Berlichingen (4)
- Iron Hand (3)
- blockchain (3)
- hand prosthesis (3)
- 3D-CAD (2)
- Blockchain (2)
- CNC (2)
- CPC (2)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (32)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (29)
- INES - Institut für nachhaltige Energiesysteme (13)
- Fakultät Wirtschaft (W) (9)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (8)
- POIM - Peter Osypka Institute of Medical Engineering (7)
- Fakultät Medien (M) (ab 22.04.2021) (4)
- IMLA - Institute for Machine Learning and Analytics (4)
- ACI - Affective and Cognitive Institute (2)
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (2)
Open Access
- Gold (75) (remove)
Non-contact anterior cruciate ligament injuries typically occur during cutting maneuvers and are associated with high peak knee abduction moments (KAM) within early stance. To screen athletes for injury risk or quantify the efficacy of prevention programs, it may be necessary to design tasks that mimic game situations. Thus, this study compared KAMs and ranking consistency of female handball players in three sport-specific fake-and-cut tasks of increasing complexity. The biomechanics of female handball players (n = 51, mean ± SD: 66.9 ± 7.8 kg, 1.74 ± 0.06 m, 19.2 ± 3.4 years) were recorded with a 3D motion capture system and force plates during three standardized fake-and-cut tasks. Task 1 was designed as a simple pre-planned cut, task 2 included catching a ball before a pre-planned cut in front of a static defender, and task 3 was designed as an unanticipated cut with three dynamic defenders involved. Inverse dynamics were used to calculate peak KAM within the first 100 ms of stance. KAM was decomposed into the frontal plane knee joint moment arm and resultant ground reaction force. RANOVAs (α ≤ 0.05) were used to reveal differences in the KAM magnitudes, moment arm, and resultant ground reaction force for the three tasks. Spearman's rank correlations were calculated to test the ranking consistency of the athletes' KAMs. There was a significant task main effect on KAM (p = 0.02; ηp2 = 0.13). The KAM in the two complex tasks was significantly higher (task 2: 1.73 Nm/kg; task 3: 1.64 Nm/kg) than the KAM in the simplest task (task 1: 1.52 Nm/kg). The ranking of the peak KAM was consistent regardless of the task complexity. Comparing tasks 1 and 2, an increase in KAM resulted from an increased frontal plane moment arm. Comparing tasks 1 and 3, higher KAM in task 3 resulted from an interplay between both moment arm and the resultant ground reaction force. In contrast to previous studies, unanticipated cutting maneuvers did not produce the highest KAMs. These findings indicate that the players have developed an automated sport-specific cutting technique that is utilized in both pre-planned and unanticipated fake-and-cut tasks.
Deep learning approaches are becoming increasingly important for the estimation of the Remaining Useful Life (RUL) of mechanical elements such as bearings. This paper proposes and evaluates a novel transfer learning-based approach for RUL estimations of different bearing types with small datasets and low sampling rates. The approach is based on an intermediate domain that abstracts features of the bearings based on their fault frequencies. The features are processed by convolutional layers. Finally, the RUL estimation is performed using a Long Short-Term Memory (LSTM) network. The transfer learning relies on a fixed-feature extraction. This novel deep learning approach successfully uses data of a low-frequency range, which is a precondition to use low-cost sensors. It is validated against the IEEE PHM 2012 Data Challenge, where it outperforms the winning approach. The results show its suitability for low-frequency sensor data and for efficient and effective transfer learning between different bearing types.
Injury prevention is essential in running due to the risk of overuse injury development. Tailoring running shoes to individual needs may be a promising strategy to reduce this risk. Novel manufacturing processes allow the production of individualised running shoes that incorporate features that meet individual biomechanical and experiential needs. However, specific ways to individualise footwear to reduce injury risk are poorly understood. Therefore, this scoping review provides an overview of (1) footwear design features that have the potential for individualisation; and (2) the literature on the differential responses to footwear design features between selected groups of individuals. These purposes focus exclusively on reducing the risk of overuse injuries. We included studies in the English language on adults that analysed: (1) potential interaction effects between footwear design features and subgroups of runners or covariates (e.g., age, sex) for running-related biomechanical risk factors or injury incidences; (2) footwear comfort perception for a systematically modified footwear design feature. Most of the included articles (n = 107) analysed male runners. Female runners may be more susceptible to footwear-induced changes and overuse injury development; future research should target more heterogonous sampling. Several footwear design features (e.g., midsole characteristics, upper, outsole profile) show potential for individualisation. However, the literature addressing individualised footwear solutions and the potential to reduce biomechanical risk factors is limited. Future studies should leverage more extensive data collections considering relevant covariates and subgroups while systematically modifying isolated footwear design features to inform footwear individualisation.
Lithium-ion battery cells exhibit a complex and nonlinear coupling of thermal, electrochemical,and mechanical behavior. In order to increase insight into these processes, we report the development of a pseudo-three-dimensional (P3D) thermo-electro-mechanical model of a commercial lithium-ion pouch cell with graphite negative electrode and lithium nickel cobalt aluminum oxide/lithium cobalt oxide blend positive electrode. Nonlinear molar volumes of the active materials as function of lithium stoichiometry are taken from literature and implemented into the open-source software Cantera for convenient coupling to battery simulation codes. The model is parameterized and validated using electrical, thermal and thickness measurements over a wide range of C-rates from 0.05 C to 10 C. The combined experimental and simulated analyses show that thickness change during cycling is dominated by intercalation-induced swelling of graphite, while swelling of the two blend components partially cancel each other. At C-rates above 2 C, electrochemistry-induced temperature increase significantly contributes to cell swelling due to thermal expansion. The thickness changes are nonlinearly distributed over the thickness of the electrode pair due to gradients in the local lithiation, which may accelerate local degradation. Remaining discrepancies between simulation and experiment at high C-rates might be attributed to lithium plating, which is not considered in the model at present.
In this project, different calcification methods for collagen and collagen coatings were compared in terms of their applicability for 3D printing and production of collagen-coated scaffolds. For this purpose, scaffolds were printed from polycaprolactone PCL using the EnvisionTec 3D Bioplotter and then coated with collagen. Four different coating methods were then applied: hydroxyapatite (HA) powder directly in the collagen coating, incubation in 10× SBF, coating with alkaline phosphatase (ALP), and coating with poly-L-aspartic acid. The results were compared by ESEM, µCT, TEM, and EDX. HA directly in the collagen solution resulted in a pH change and thus an increase in viscosity, leading to clumping on the scaffolds. As a function of incubation time in 10× SBF as well as in ALP, HA layer thickness increased, while no coating on the collagen layer was apparently observed with poly-L-aspartic acid. Only ultrathin sections and TEM with SuperEDX detected nano crystalline HA in the collagen layer. Exclusively the incubation in poly-L-aspartic acid led to HA crystals within the collagen coating compared to all other methods where the HA layers formed in different forms only at the collagen layer.
Spatially Distributed Wireless Networks (SDWN) are one of the basic technologies for the Internet of Things (IoT) and (Industrial) Internet of Things (IIoT) applications. These SDWN for many of these applications has strict requirements such as low cost, simple installation and operations, and high potential flexibility and mobility. Among the different Narrowband Wireless Wide Area Networking (NBWWAN) technologies, which are introduced to address these categories of wireless networking requirements, Narrowband Internet of Things (NB-IoT) is getting more traction due to attractive system parameters, energy-saving mode of operation with low data rates and bandwidth, and its applicability in 5G use cases. Since several technologies are available and because the underlying use cases come with various requirements, it is essential to perform a systematic comparative analysis of competing technologies to choose the right technology. It is also important to perform testing during different phases of the system development life cycle. This paper describes the systematic test environment for automated testing of radio communication and systematic measurements of the performance of NB-IoT.
Batteries typically consist of multiple individual cells connected in series. Here we demonstrate single-cell state of charge (SOC) and state of health (SOH) diagnosis in a 24 V class lithium-ion battery. To this goal, we introduce and apply a novel, highly efficient algorithm based on a voltage-controlled model (VCM). The battery, consisting of eight single cells, is cycled over a duration of five months under a simple cycling protocol between 20 % and 100 % SOC. The cell-to-cell standard deviations obtained with the novel algorithm were 1.25 SOC-% and 1.07 SOH-% at beginning of cycling. A cell-averaged capacity loss of 9.9 % after five months cycling was observed. While the accuracy of single-cell SOC estimation was limited (probably owed to the flat voltage characteristics of the lithium iron phosphate, LFP, chemistry investigated here), single-cell SOH estimation showed a high accuracy (2.09 SOH-% mean absolute error compared to laboratory reference tests). Because the algorithm does not require observers, filters, or neural networks, it is computationally very efficient (three seconds analysis time for the complete data set consisting of eight cells with approx. 780.000 measurement points per cell).
With the function RooTri(), we present a simple and robust calculation method for the approximation of the intersection points of a scalar field given as an unstructured point cloud with a plane oriented arbitrarily in space. The point cloud is approximated to a surface consisting of triangles whose edges are used for computing the intersection points. The function contourc() of Matlab is taken as a reference. Our experiments show that the function contourc() produces outliers that deviate significantly from the defined nominal value, while the quality of the results produced by the function RooTri() increases with finer resolution of the examined grid.
Running stability is the ability to withstand naturally occurring minor perturbations during running. It is susceptible to external and internal running conditions such as footwear or fatigue. However, both its reliable measurability and the extent to which laboratory measurements reflect outdoor running remain unclear. This study aimed to evaluate the intra- and inter-day reliability of the running stability as well as the comparability of different laboratory and outdoor conditions. Competitive runners completed runs on a motorized treadmill in a research laboratory and overground both indoors and outdoors. Running stability was determined as the maximum short-term divergence exponent from the raw gyroscope signals of wearable sensors mounted to four different body locations (sternum, sacrum, tibia, and foot). Sacrum sensor measurements demonstrated the highest reliabilities (good to excellent; ICC = 0.85 to 0.91), while those of the tibia measurements showed the lowest (moderate to good; ICC = 0.55 to 0.89). Treadmill measurements depicted systematically lower values than both overground conditions for all sensor locations (relative bias = -9.8% to -2.9%). The two overground conditions, however, showed high agreement (relative bias = -0.3% to 0.5%; relative limits of agreement = 9.2% to 15.4%). Our results imply moderate to excellent reliability for both overground and treadmill running, which is the foundation of further research on running stability.
Relationships between External, Wearable Sensor-Based, and Internal Parameters: A Systematic Review
(2023)
Micro electro-mechanical systems (MEMS) are used to record training and match play of intermittent team sport athletes. Paired with estimates of internal responses or adaptations to exercise, practitioners gain insight into players’ dose–response relationship which facilitates the prescription of the training stimuli to optimize performance, prevent injuries, and to guide rehabilitation processes. A systematic review on the relationship between external, wearable-based, and internal parameters in team sport athletes, compliant with the PRISMA guidelines, was conducted. The literature research was performed from earliest record to 1 September 2020 using the databases PubMed, Web of Science, CINAHL, and SportDISCUS. A total of 66 full-text articles were reviewed encompassing 1541 athletes. About 109 different relationships between variables have been reviewed. The most investigated relationship across sports was found between (session) rating of perceived exertion ((session-)RPE) and PlayerLoad™ (PL) with, predominantly, moderate to strong associations (r = 0.49–0.84). Relationships between internal parameters and highly dynamic, anaerobic movements were heterogenous. Relationships between average heart rate (HR), Edward’s and Banister’s training impulse (TRIMP) seem to be reflected in parameters of overall activity such as PL and TD for running-intensive team sports. PL may further be suitable to estimate the overall subjective perception. To identify high fine-structured loading—relative to a certain type of sport—more specific measures and devices are needed. Individualization of parameters could be helpful to enhance practicality.