With recent developments in the Ukrainian-Russian conflict, many are discussing about Germany’s dependency on fossil fuel imports in its energy system, and how can the country proceed with reducing that dependency. With its wide-ranging consumption sectors, the electricity sector comes as the perfect choice to start with. Recent reports showed that the German federal government is already intending to have a fully renewable electricity by 2035 while exploiting all possible clean power options. This was published in the federal government’s climate emergency program (Easter Package) in early 2022. The aim of this package is to initiate a rapid transition and decarbonization of the electricity sector. The Easter Package expects an enormous growth of renewable energies to a completely new level, with already at least 80% renewable gross energy consumption, with extensive and broad deployment of different generation technologies on various scales. This paper will discuss this ambitious plan and outline some insights into this huge and rapidly increasing step, and show how much will Germany need in order to achieve this huge milestone towards a fully green supply of the electricity sector. Different scenarios and shares of renewables will be investigated in order to elaborate on preponed climate-neutral goal of the electricity sector by 2035. The results pointed out some promising aspects in achieving a 100% renewable power, with massive investments in both generation and storage technologies.
The sharp rise in electricity and oil prices due to the war in Ukraine has caused fluctuations in the results of the previous study about the economic analysis of electric buses. This paper shows how the increase in fuel prices affects the implementation of electric buses. This publication is constructing the Total Cost of Ownership (TCO) model in the small-mid-size city, Offenburg for the transition to electric buses. The future development of costs is estimated and a projection based on learning curves will be carried out. This study intends to introduce a new future prospect by presenting the latest data based on previous research. Through the new TCO result, the cost differences between the existing diesel bus and the electric bus are updated, and also the future prospects for the economic feasibility of the electric bus in a small and midsize city are presented.
The formation of secondary phases in the porous electrodes is a severe mechanism affecting the lifetime of solid oxide fuel cells (SOFC). It can occur via various chemical mechanisms and it has a significant influence on cell performance due to pore clogging and deactivation of active surfaces and triple-phase boundary (TPB). We present a modeling and simulation study of nickel oxide formation (reoxidation) and carbon formation (coking) within the SOFC anode. We use a 2D continuum model based on a multi-phase framework [Neidhardt et al., J. Electrochem. Soc., 159, 9 (2012)] that allows the introduction of arbitrary solid phases (here: Ni, YSZ, NiO, Carbon) plus gas phase. Reactions between the bulk phases are modeled via interface-adsorbed species and are described by an elementary kinetic approach. Published experimental data are used for parameterization and validation. Simulations allow the prediction of cell performance under critical operation conditions, like (i) a non-fuel operation test, where NiO formation is taking place (Figure 1a), or (ii) an open circuit voltage (OCV) stability test under hydrocarbon atmosphere, where solid carbon is formed (Figure 1b). Results are applied for enhanced interpretation of experimental data and for prediction of safe operation conditions.
The twin concept is increasingly used for optimization tasks in the context of Industry 4.0 and digitization. The twin concept can also help small and medium-sized enterprises (SME) to exploit their energy flexibility potential and to achieve added value by appropriate energy marketing. At the same time, this use of flexibility helps to realize a climate-neutral energy supply with high shares of renewable energies. The digital twin reflects real production, power flows and market influences as a computer model, which makes it possible to simulate and optimize on-site interventions and interactions with the energy market without disturbing the real production processes. This paper describes the development of a generic model library that maps flexibility-relevant components and processes of SME, thus simplifying the creation of a digital twin. The paper also includes the development of an experimental twin consisting of SME hardware components and a PLC-based SCADA system. The experimental twin provides a laboratory environment in which the digital twin can be tested, further developed and demonstrated on a laboratory scale. Concrete implementations of such a digital twin and experimental twin are described as examples.
The contribution of the RoofKIT student team to the SDE 21/22 competition is the extension of an existing café in Wuppertal, Germany, to create new functions and living space for the building with simultaneous energetic upgrading. A demonstration unit is built representing a small cut-out of this extension. The developed energy concept was thoroughly simulated by the student team in seminars using Modelica. The system uses mainly solar energy via PVT collectors as the heat source for a brine-water heat pump (space heating and hot water). Energy storage (thermal and electrical) is installed to decouple generation and consumption. Simulation results confirm that carbon neutrality is achieved for the building operation, consuming and generating around 60 kWh/m2a.
The uncertain and time-variant nature of renewable energy results in the need to deal with peaks in the production of energy. One approach is to achieve a load shift and thereby help balancing the grid by using thermally Activated Building Systems (TABS). Control systems currently in place do not exploit the full potential of TABS. This paper reviews how Model Predictive Control can possibly reduce the fluctuations of the demand and supply of (renewable) energy as it enables the TABS to react to the dynamics of weather and its impact on the grid at any time.
In the dual membrane fuel cell (DM-Cell), protons formed at the anode and oxygen ions formed at the cathode migrate through their respective dense electrolytes to react and form water in a porous composite layer called dual membrane (DM). The DM-Cell concept was experimentally proven (as detailed in Part I of this paper). To describe the electrochemical processes occurring in this novel fuel cell, a mathematical model has been developed which focuses on the DM as the characteristic feature of the DM-Cell. In the model, the porous composite DM is treated as a continuum medium characterized by effective macro-homogeneous properties. To simulate the polarization behavior of the DM-Cell, the potential distribution in the DM is related to the flux of protons and oxygen ions in the conducting phases by introducing kinetic and transport equations into charge balances. Since water pressure may affect the overall formation rate, water mass balances across the DM and transport equations are also considered. The satisfactory comparison with available experimental results suggests that the model provides sound indications on the effects of key design parameters and operating conditions on cell behavior and performance.
We describe a prototype for power line communi- cation for grid monitoring. The PLC receiver is used to gain information about the PLC channel and the current state of the power grid. The PLC receiver uses the communication signal to obtain an accurate estimate of the current channel and provides information which can be used as a basis for further processing with the aim to detect partial discharges and other anomalies in the grid. This monitoring of the power grid takes advantage of existing PLC infrastructure and uses the data signals, which are transmitted anyway to obtain a real-time measurement of the channel transfer function and the received noise signal. Since this signal is sampled at a high sampling rate compared to simpler measurement sensors, it contains valuable information about possible degradations in the grid which need to be addressed. While channel measurements are based on a received PLC signal, information about partial discharges or other sources of interference can be gathered by a PLC receiver in the absence of a transmit signal. A prototype based on Software Defined Radio has been developed, which implements the simultaneous communication and sensing for a power grid.
The PHOTOPUR project aims to develop a photocatalytic process as a type of AOPs (Advanced Oxidation Processes) for the elimination of plant protection products (PPP) of the cleaning water used to wash sprayers. At INES a PV based energy supply for the photocatalytic cleaning system was developed within the framework of two bachelor theses and assembled as a demonstration unit. Then the system was step by step extended with further process automation features and pushed to a remote operating device. The final system is now available as a mobile unit mounted on a lab table. The latest step was the photocatalytic reactor module which completed the first PHOTOPUR prototype. The system is actually undergoing an intensive testing phase with performance checks at the consortium partners. First results give an overview about the successful operation.
Significant improvements in module performance are possible via implementation of multi-wire electrodes. This is economically sound as long as the mechanical yield of the production is maintained. While flat ribbons have a relatively large contact area to exert forces onto the solar cell, wires with round cross section reduce this contact area considerably – in theory to an infinitively thin line. Therefore, the local stresses induced by the electrodes might increase to a point that mechanical production yields suffer unacceptably.
In this paper, we assess this issue by an analytical mechanical model as well as experiments with an encapsulant-free N.I.C.E. test setup. From these, we can derive estimations for the relationship between lay-up accuracy and expected breakage losses. This paves the way for cost-optimized choices of handling equipment in industrial N.I.C.E.-wire production lines.