Refine
Year of publication
Document Type
- Article (reviewed) (17)
- Article (unreviewed) (5)
- Conference Proceeding (3)
- Contribution to a Periodical (2)
- Bachelor Thesis (1)
- Book (1)
Conference Type
- Konferenzartikel (2)
- Konferenz-Abstract (1)
Keywords
- Dünnschichtchromatographie (29) (remove)
Institute
Open Access
- Closed Access (19)
- Open Access (4)
- Closed (1)
A 2D-separation of 16 polyaromatic hydrocarbons (PAHs) according to the Environmental Protecting Agency (EPA) standard was introduced. Separation took place on a TLC RP-18 plate (Merck, 1.05559). In the first direction, the plate was developed twice using n-pentane at −20°C as the mobile phase. The mixture acetonitrile-methanol-acetone-water (12:8:3:3, v/v) was used for developing the plate in the second direction. Both developments were carried out over a distance of 43 mm. Further on in this publication, a specific and very sensitive indication method for benzo[a]pyrene and perylene was presented. The method can detect these hazardous compounds even in complicated PAH mixtures. These compounds can be quantified by a simple chemiluminescent reaction with a limit of detection (LOD) of 48 pg per band for perylene and 95 pg per band for benzo[a]pyrene. Although these compounds were separated from all other PAHs in the standard, a separation of both compounds was not possible from one another. The method is suitable for tracing benzo[a]pyrene and/or perylene. The proposed chemiluminescence screening test on PAHs is extremely sensitive but may indicate a false positive result for benzo[a]pyrene.
HPTLC (High Performance Thin Layer Chromatography) is a well known and versatile separation method which shows many advantages when compared to other separation techniques. The method is fast and inexpensive and does not need time-consuming pretreatments. For visualisation of the sample distribution on a HPTLC-plate we developed a new and sturdy HPTLC-scanner. The scanner allows simultaneous registrations of spectra in a range from 198 nm to 612 nm with a spectral resolution of better than 0.8 nm. The on-plate spatial resolution is better than 160 μm. The measurement of 450 spectra in one separation track does not need more than two minutes. The new diode-array scanner offers a fast survey over a TLC-separation and makes various chemometric applications possible. For compound identification a cross-correlation function is described to compare UV sample spectra with appropriate library data. The cross-correlation function herein described can also be used for purity testing. Unresolved peaks can be virtually separated by use of a least squares fit algorithm. In summary, the diode arry system delivers much more information than the commonly used TLC-scanner.
Phenolic compounds, such as flavonoids and phenolic acids, are very important substances that occur in various medicinal plants. They show different pharmacological activities which might be useful in the therapy of many diseases. Phenolic compounds have achieved an increasing interest over the last years because these compounds are easily oxidized and, thus, act as strong antioxidants. We present the chemiluminescence of different phenolic compounds measured directly on high-performance thin-layer chromatography LiChrospher® plates using the oxalic acid derivative bis(2,4,6-trichlorophenyl) oxalate (TCPO) in conjunction with H2O2. Our results indicate that chemiluminescence intensity increases with an ascending number of phenolic groups in the molecule. The method can be used to detect phenolic compounds in beverages like coffee, tea, and wine.
Vorgestellt wird die Dioden-Array-Dünnschichtchromatographie als eine moderne und preiswerte Messmethode zur densitometrischen Erfassung von Substanzen auf einer DC- oder einer HPTLC-Platte. Sicher identifizierbar sind auch Substanzen mit schwachem Chromophor. Die Kubelka-Munk-Gleichung beschreibt einen linearen Zusammenhang zwischen Remissionslicht und lichtabsorbierender Stoffmenge auf der Platte. Die Auswertung im Spektralbereich von 316 bis 334 nm zeigt den Zusammenhang zwischen transformiertem Messsignal und aufgetragener Substanzmasse. Die schnelle Aufnahme von UV/vis-Spektren eröffnet der HPTLC den gesamten Bereich der Methodenvalidierung auf dem Niveau, auf welchem heute die HPLC-Analytik durchgeführt wird.
Improved separation of highly toxic contact herbicides paraquat (1,1′-dimethyl-4-4′-bipyridinium), diquat (6,7-dihydrodipyridol[ 1,2-a:2′,1′-c]pyrazine-5,8-di-ium), difenzoquat (1,2-dimethyl-3,5-diphenyl-1H-pyrazolium-methyl sulfate), mepiquat (1,1-dimethyl-piperidinium), and chloromequat (2-chloroethyltrimethylammonium) were presented by high-performance thin-layer chromatography (HPTLC). The quantification is based on a derivatization reaction, using sodium tetraphenylborate. Measurements were made in the wavelength range from 500 to 535 nm, using a light-emitting diode (LED) for excitation purposes, which emits very dense light at 365 nm. For calculations, a new theory of standard addition method was used, thus leading to a minimal error if exactly the same amount of sample content is added as a standard. The method provides a fast and inexpensive approach to quantification of the five most important quats used for plant protection purposes. The method works reliably because it takes into account losses during pre-treatment procedure. The method meets the European legislation limits for paraquat and diquat in drinking water according to United States Environmental Protection Agency (US EPA) method 549.2 which are 680 ng L−1 for paraquat and 720 ng L−1 for diquat. The method of standard addition in planar chromatography can be beneficially used to reduce systematic errors. Although recovery rates of 33.7% to 65.2% are observed, calculated contents according to the method of standard addition lie between 69% and 127% of the theoretical amounts.
We present a video-densitometric quantification method for the pain killer known as diclofenac and ibuprofen. These non-steroidal anti-inflammatory drugs were separated on cyanopropyl bonded plates using CH2Cl2, methanol, cyclohexane (95 + 5 + 40, v/v) as mobile phase. The quantification is based on a bio-effective-linked analysis using Vibrio fisheri bacteria. Within 10 min a CCD-camera registered the white light of the light-emitting bacteria. Diclofenac and ibuprofen effectively suppressed the bacterial light emission which can be used for quantification within a linear range of 10 to 2000 ng. The detection limit for ibuprofen is 20 ng and the limit of quantification 26 ng per zone. Measurements were carried out using a 16-bit ST-1603ME CCD camera with 1.56 megapixels (from Santa Barbara Instrument Group, Inc., Santa Barbara, USA). The range of linearity covers more than two magnitudes because the extended Kubelka-Munk expression is used for data transformation. The separation method is inexpensive, fast, and reliable.
Das einzige deutschsprachige Buch zur quantitativen Dünnschichtchromatographie auf dem Markt
Für Wissenschaftler und Anwender: von der vollständigen Behandlung der Theorie bis hin zu Entwicklungs- und Auswertetechniken
Auch für Einsteiger geeignet, da das Buch entsprechend der Arbeitsschritte einer DC-Analyse aufgebaut ist
We present a video-densitometric quantification method in combination with diode-array quantification for the methyl-, ethyl-, propyl-, and butylparaben in cosmetics. These parabens were separated on cyanopropyl bonded plates using water-acetonitrile-dioxane-ethanol-NH3 (25%) (8:2:1:1:0.05, v/v) as mobile phase. The quantification is based on UV-measurements at 255 nm and a bioeffectively-linked analysis using Vibrio fischeri bacteria. Within 5 min, a Tidas S 700 diode-array scanner (J&M, Aalen, Germany) scans 8 tracks and thus measures in total 5600 spectra in the wavelengths range from 190 to 1000 nm. The quantification range for all these parabens is from 20 to 400 ng per band, measured at 255 nm. In the V. fischeri assay a CCD-camera registers the white light of the light-emitting bacteria within 10 min. All parabens effectively suppress the bacterial light emission which can be used for quantifying within a linear range from 100 to 400 ng. Measurements were carried out using a 16-bit MicroChemi chemiluminescence system (biostep GmbH, Jahnsdorf, Germany), using a CCD camera with 4.19 megapixels. The range of linearity is achieved because the extended Kubelka-Munk expression was used for data transformation. The separation method is inexpensive, fast, and reliable.
The efficiency of a chromatographic analytical method is determined by the selectivity of the chromatographic separation and the specificity of the detection method. In high-performance thin-layer chromatography (HPTLC) the separated components can be detected and quantified directly on the plate by physical and chemical methods. By coupling high-performance thin-layer chromatography with biological or biochemical inhibition tests it is possible to detect toxic substances in situ.