Refine
Year of publication
Document Type
- Article (reviewed) (7)
- Article (unreviewed) (6)
- Conference Proceeding (5)
- Part of a Book (3)
- Bachelor Thesis (1)
- Book (1)
- Master's Thesis (1)
- Report (1)
Conference Type
- Konferenzartikel (4)
- Sonstiges (1)
Keywords
- Energieversorgung (25) (remove)
Institute
Open Access
- Open Access (8)
- Closed Access (6)
- Closed (3)
Kolbenmotoren finden in der Energieversorgung vielfältig Verwendung als Notstromaggregate, als Antrieb für Pumpen in Großkraftwerken und in dezentralen Blockheizkraftwerken (BHKW). Motoren für Notstromaggregate und zum Antrieb von Arbeitsmaschinen werden meist mit Diesel-Kraftstoff betrieben. In BHKW dominieren Gasmotoren, wobei Erdgas, Bio-, Deponie- oder Klärgas bevorzugt sind. Die wesentliche Thermodynamik der Otto-, Diesel- und Stirling-Motoren wird in Kürze behandelt, während die Gasmotoren tiefere Behandlung finden. Die Motoren für die Energieversorgung stammen i. Allg. von mobilen Anwendungen ab und werden an die energietechnischen Anwendungen angepasst. Technische Details der Motoren sind in der Fachliteratur zu finden, z. B. [1]. Die Website [2] gibt einen umfassenden Überblick über Hersteller und deren Kolbenmotoren.
Die Hochschule Offenburg begleitet seit Juli 2006 in Zusammenarbeit mit dem Fraunhofer ISE in Freiburg und der HfT Stuttgart die solar unterstützte Klimatisierung der Festo AG & Co. KG in Esslingen. Die Anlage wurde im Rahmen des Forschungsvorhabens „Solarthermie2000plus“ vom Bundesumweltministerium gefördert. Dabei wurde die bereits bestehende Adsorptionskälteanlage, die bisher mit Kompressorabwärme und Gaskesseln betrieben wurde, durch eine Solaranlage als drittem Wärmelieferanten ergänzt.
In den vergangenen Jahren ist das technische Gas Schwefelhexafluorid (SF6) immer wieder Gegenstand von Diskussionen des Klimaschutzes und der technischen Notwendigkeit für den Betrieb von Schaltanlagen gewesen und wird dies wohl auch noch für längere Zeit bleiben. Das Gas, welches sich aus einem Schwefelatom und sechs Fluoratomen zusammensetzt, wird seit Ende der sechziger 1960er Jahre in Schaltanlagen der Mittel- und Hochspannung eingesetzt. So günstig dessen Eigenschaften im technischen Einsatz auch sind, so klimaschädlich ist es beim Entweichen in die Atmosphäre. SF6 ist das Klimagas mit dem größten bekannten Treibhauspotenzial, es weist ein CO2-Äquivalent (GWP) von 23.900 und eine atmosphärische Lebensdauer von ca. 3.200 Jahren auf. Neben nur wenig verbliebenen Anwendungen in Industrie, Militär und Medizin kommt es heute hauptsächlich bei der elektrischen Energieversorgung als Isolier- und Lichtbogenlöschgas in Schaltanlagen von Übertragungs- und Verteilnetzen zum Einsatz. Grund genug die technische Notwendigkeit, mögliche Alternativen und Konsequenzen drohender Verbote zu diskutieren. In diesem Artikel werden zunächst die Grundlagen moderner SF6- Hochspannungsschaltanlagen vorgestellt, die Klimabelastung durch entweichendes SF6 evaluiert, ein Überblick über den Stand der Forschung gegeben und mögliche Konsequenzen eines Verbotes von Schwefelhexafluorid in der Energieversorgung diskutiert.
Ecological concerns on the climatic effects of the emissions from electricity production stipulate the remuneration of electricity grids to accept growing amounts of intermittent regenerative electricity feed-in from wind and solar power. Germany’s eager political target to double regenerative electricity production by 2030 puts pressure on grid operators to adapt and restructure their transmission and distribution grids. The ability of local distribution grids to operate autonomous of transmission grid supply is essential to stabilize electricity supply at the level of German federal states. Although congestion management and collaboration at the distribution system operator (DSO) level are promising approaches, relatively few studies address this issue. This study presents a methodology to assess the electric energy balance for the low-voltage grids in the German federal state of Baden-Württemberg, assuming the typical load curves and the interchange potential among local distribution grids by means of linear programming of the supply function and for typical seasonal electricity demands. The model can make a statement about the performance and development requirements for grid architecture for scenarios in 2035 and 2050 when regenerative energies will—according to present legislation—account for more than half of Germany’s electricity supply. The study details the amendment to Baden-Württemberg’s electricity grid required to fit the system to the requirements of regenerative electricity production. The suggested model for grid analysis can be used in further German regions and internationally to systematically remunerate electricity grids for the acceptance of larger amounts of regenerative electricity inflows. This empirical study closes the research gap of assessing the interchange potential among DSO and considers usual power loads and simultaneously usual electricity inflows.
In the dual membrane fuel cell (DM-Cell), protons formed at the anode and oxygen ions formed at the cathode migrate through their respective dense electrolytes to react and form water in a porous composite layer called dual membrane (DM). The DM-Cell concept was experimentally proven (as detailed in Part I of this paper). To describe the electrochemical processes occurring in this novel fuel cell, a mathematical model has been developed which focuses on the DM as the characteristic feature of the DM-Cell. In the model, the porous composite DM is treated as a continuum medium characterized by effective macro-homogeneous properties. To simulate the polarization behavior of the DM-Cell, the potential distribution in the DM is related to the flux of protons and oxygen ions in the conducting phases by introducing kinetic and transport equations into charge balances. Since water pressure may affect the overall formation rate, water mass balances across the DM and transport equations are also considered. The satisfactory comparison with available experimental results suggests that the model provides sound indications on the effects of key design parameters and operating conditions on cell behavior and performance.
Electric arc furnaces (EAF) are complex industrial plants whose actual behavior depends upon numerous factors. Due to its energy intensive operation, the EAF process has always been subject to optimization efforts. For these reasons, several models have been proposed in literature to analyze and predict different modes of operation. Most of these models focused on the processes inside the vessel itself. The present paper introduces a dynamic, physics-based model of a complete EAF plant which consists of the four subsystems vessel, electric system, electrode regulation, and off-gas system. Furthermore the solid phase is not treated to be homogenous but a simple spatial discretization is employed. Hence it is possible to simulate the energy input by electric arcs and fossil fuel burners depending on the state of the melting progress. The model is implemented in object-oriented, equation-based language Modelica. The simulation results are compared to literature data.