A 2D-separation of 16 polyaromatic hydrocarbons (PAHs) according to the Environmental Protecting Agency (EPA) standard was introduced. Separation took place on a TLC RP-18 plate (Merck, 1.05559). In the first direction, the plate was developed twice using n-pentane at −20°C as the mobile phase. The mixture acetonitrile-methanol-acetone-water (12:8:3:3, v/v) was used for developing the plate in the second direction. Both developments were carried out over a distance of 43 mm. Further on in this publication, a specific and very sensitive indication method for benzo[a]pyrene and perylene was presented. The method can detect these hazardous compounds even in complicated PAH mixtures. These compounds can be quantified by a simple chemiluminescent reaction with a limit of detection (LOD) of 48 pg per band for perylene and 95 pg per band for benzo[a]pyrene. Although these compounds were separated from all other PAHs in the standard, a separation of both compounds was not possible from one another. The method is suitable for tracing benzo[a]pyrene and/or perylene. The proposed chemiluminescence screening test on PAHs is extremely sensitive but may indicate a false positive result for benzo[a]pyrene.
The state-of-the-art electrochemical impedance spectroscopy (EIS) calculations have not yet started from fully multi-dimensional modeling. For a polymer electrolyte membrane fuel cell (PEMFC) with long flow channel, the impedance plot shows a multi-arc characteristic and some impedance arcs could merge. By using a step excitation/Fourier transform algorithm, an EIS simulation is implemented for the first time based on the full 2D PEMFC model presented in the first part of this work. All the dominant transient behaviors are able to be captured. A novel methodology called ‘configuration of system dynamics’, which is suitable for any electrochemical system, is then developed to resolve the physical meaning of the impedance spectra. In addition to the high-frequency arc due to charge transfer, the Nyquist plots contain additional medium/low-frequency arcs due to mass transfer in the diffusion layers and along the channel, as well as a low-frequency arc resulting from water transport in the membrane. In some case, the impedance spectra appear partly inductive due to water transport, which demonstrates the complexity of the water management of PEMFCs and the necessity of physics-based calculations.
A two-dimensional single-phase model is developed for the steady-state and transient analysis of polymer electrolyte membrane fuel cells (PEMFC). Based on diluted and concentrated solution theories, viscous flow is introduced into a phenomenological multi-component modeling framework in the membrane. Characteristic variables related to the water uptake are discussed. A Butler–Volmer formulation of the current-overpotential relationship is developed based on an elementary mechanism of electrochemical oxygen reduction. Validated by using published V–I experiments, the model is then used to analyze the effects of operating conditions on current output and water management, especially net water transport coefficient along the channel. For a power PEMFC, the long-channel configuration is helpful for internal humidification and anode water removal, operating in counterflow mode with proper gas flow rate and humidity. In time domain, a typical transient process with closed anode is also investigated.
Photovoltaics Energy Prediction Under Complex Conditions for a Predictive Energy Management System
(2015)
The energy system of the future will transform from the current centralised fossil based to a decentralised, clean, highly efficient, and intelligent network. This transformation will require innovative technologies and ideas like trigeneration and the crowd energy concept to pave the way ahead. Even though trigeneration systems are extremely energy efficient and can play a vital role in the energy system, turning around their deployment is hindered by various barriers. These barriers are theoretically analysed in a multiperspective approach and the role decentralised trigeneration systems can play in the crowd energy concept is highlighted. It is derived from an initial literature research that a multiperspective (technological, energy-economic, and user) analysis is necessary for realising the potential of trigeneration systems in a decentralised grid. And to experimentally quantify these issues we are setting up a microscale trigeneration lab at our institute and the motivation for this lab is also briefly introduced.
Combined heat and power production (CHP) based on solid oxide fuel cells (SOFC) is a very promising technology to achieve high electrical efficiency to cover power demand by decentralized production. This paper presents a dynamic quasi 2D model of an SOFC system which consists of stack and balance of plant and includes thermal coupling between the single components. The model is implemented in Modelica® and validated with experimental data for the stack UI-characteristic and the thermal behavior. The good agreement between experimental and simulation results demonstrates the validity of the model. Different operating conditions and system configurations are tested, increasing the net electrical efficiency to 57% by implementing an anode offgas recycle rate of 65%. A sensitivity analysis of characteristic values of the system like fuel utilization, oxygen-to-carbon ratio and electrical efficiency for different natural gas compositions is carried out. The result shows that a control strategy adapted to variable natural gas composition and its energy content should be developed in order to optimize the operation of the system.
The transformation of the building energy sector to a highly efficient, clean, decentralised and intelligent system requires innovative technologies like microscale trigeneration and thermally activated building structures (TABS) to pave the way ahead. The combination of such technologies however presents a scientific and engineering challenge. Scientific challenge in terms of developing optimal thermo-electric load management strategies based on overall energy system analysis and an engineering challenge in terms of implementing these strategies through process planning and control. Initial literature research has pointed out the need for a multiperspective analysis in a real life laboratory environment. To this effect an investigation is proposed wherein an analytical model of a microscale trigeneration system integrated with TABS will be developed and compared with a real life test-rig corresponding to building management systems. Data from the experimental analysis will be used to develop control algorithms using model predictive control for achieving the thermal comfort of occupants in the most energy efficient and grid reactive manner. The scope of this work encompasses adsorption cooling based microscale trigeneration systems and their deployment in residential and light commercial buildings.