Refine
Year of publication
Document Type
- Conference Proceeding (153)
Conference Type
- Konferenz-Abstract (153) (remove)
Has Fulltext
- no (153) (remove)
Is part of the Bibliography
- yes (153)
Keywords
- RoboCup (13)
- Biomechanik (9)
- Heart rhythm model (5)
- Modeling and simulation (5)
- injury (5)
- Herzkrankheit (4)
- running (4)
- CST (3)
- HF-Ablation (3)
- Katheter (3)
- biomechanics (3)
- ACL (2)
- Abtragung (2)
- CRT (2)
- Cryoballoon catheter ablation (2)
- Defibrillator (2)
- Herzrhythmusmodell (2)
- Herzrhythmusstörung (2)
- Herzschrittmacher (2)
- Kardiale Resynchronisationstherapie (2)
- Signaltechnik (2)
- Supraventricular tachycardia (2)
- Synchronisierung (2)
- Vorhofflimmern (2)
- atrial fibrillation (2)
- 3D analysis (1)
- 3D print (1)
- Abwasser (1)
- Ageing (1)
- Artificial Intelligence (1)
- Atrial fibrillation (1)
- Austausch (1)
- Bestrahlung (1)
- Bioelektrochemische Brennstoffzelle (1)
- Biogas (1)
- Biogasreaktor (1)
- Bioimpedance measurement (1)
- Brennstoffzelle (1)
- Business Intelligence (1)
- Cardiac resynchronization therapy (1)
- Dimensional Modelling (1)
- Durchblutung (1)
- Dünnschichtchromatographie (1)
- E-Learning (1)
- Electrochemistry (1)
- Electromagnetic and thermal simulation (1)
- Elektrizitätserzeugung (1)
- Elektrokardiogramm (1)
- Esophageal catheter (1)
- Eye tracking (1)
- Footwear (1)
- Gehirn (1)
- Hemodynamic monitoring (1)
- Herzmuskelkrankheit (1)
- High frequency ablation (1)
- Hochfrequenzablation (1)
- Hochfrequenztechnik (1)
- IVD (1)
- KAM (1)
- Kardiologie (1)
- Kernspintomografie (1)
- Kryoballonkatheter (1)
- Left Atrial Appendage Closure (1)
- Lithium-ion battery (1)
- Lumineszenz (1)
- Materialermüdung (1)
- Medizintechnik (1)
- Methan (1)
- Methanisierung (1)
- Methanol (1)
- Modellierung und Simulation (1)
- Modelling (1)
- Multiside heart stimulation (1)
- Physik (1)
- Prothesen (1)
- Pulmonalvenenisolation (1)
- Pulmonary vein isolation (1)
- Qualitätskontrolle (1)
- Qualitätssicherung (1)
- Radiologie (1)
- Running (1)
- SAP Analytics Cloud (1)
- SAP Data Warehouse Cloud (1)
- Schleudertrauma (1)
- Schrittmacher (1)
- Simulation (1)
- Speiseröhre (1)
- Spinal cord stimulation (1)
- Sportmedizin (1)
- Steuerung (1)
- Synchronisationstherapie (1)
- Telemetrie (1)
- Transesophageal left atrial pacing (1)
- Verbrennungsmotor (1)
- Versorgung (1)
- Weitsprung (1)
- Wellenlänge (1)
- algorithm-based data analysis (1)
- athletic performance (1)
- biomechanical stimulation (1)
- carbon elements (1)
- cushioning (1)
- cushioning (property) (1)
- customization (1)
- dickkopf 3 (1)
- echocardiography (1)
- elektrische Felder (1)
- force (1)
- high-speed cameras (1)
- impedance cardiography (1)
- kardiale Resynchronisationstherapie (1)
- mild traumatic brain injury (1)
- mobile web design guidelines (1)
- modeling (1)
- overuse (1)
- pulmonary vein isolation (1)
- road and track running (1)
- running shoe (1)
- running shoes (1)
- signal averaging (1)
- sport (1)
- thermische Felder (1)
- three-dimensional kinematic (1)
- transversal skills (1)
- wavelet transformation (1)
- Überwachung (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (75)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (47)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (19)
- IBMS - Institute for Advanced Biomechanics and Motion Studies (ab 16.11.2022) (11)
- INES - Institut für nachhaltige Energiesysteme (10)
- POIM - Peter Osypka Institute of Medical Engineering (8)
- Fakultät Wirtschaft (W) (5)
- Fakultät Medien (M) (ab 22.04.2021) (1)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (1)
- IMLA - Institute for Machine Learning and Analytics (1)
Open Access
- Open Access (101)
- Closed Access (38)
- Bronze (34)
- Closed (11)
- Diamond (3)
Energetische Aspekte gewinnen bei nachhaltig optimierten Systemen zunehmend an Bedeutung. Klassische Lösungen der Strömungsmechanik sind für viele technische Anwendungen von enormerWichtigkeit. In dieser Arbeit präsentieren wir energetische Analysen zu den unterschiedlichen Rayleigh-Stokes Problemen wie der plötzlich in Gang gesetzten oder gestoppten Platte sowie der periodisch oszillierenden Platte. Die in [1] beschriebenen klassischen Rayleigh-Stokes Probleme sind in vielfältigerWeise für verallgemeinerte Rand- und Anfangsbedingungen untersucht worden. Beispiele hierzu sind in [2, 3] dargestellt. Theoretische Grundlagen zu den folgenden energetischen Betrachtungen sind in [4, 5] enthalten.
Non-esterified plant oils gain ecological and economical importance, particularly in the EU where it is intended to increase the share of renewable energies. Plant oils do not require any chemical treatment so do not cause secondary pollution. The importance of plant oil will increase in Germany for mobile and stationary applications. The generation co-generation of heat and power is subsidized by the German “Erneuerbares Energiegesetz” and the “Kraft-Wärme-Kopplungsgesetz” when renewable fuels are used such as plant oils..
Plant oils have a much higher viscosity than conventional gas oil. It is mandatory to decrease the oil viscosity by heating prior to injection to assure proper injection and to avoid engine damage due to coke formation in the combustion chamber and at the injection nozzle. The German quality standard of Weihenstephan (RK-Qualitätsstandard 05/2000) for rape seed oil should be followed for use as diesel fuel. The chemical composition of plant oils is appreciably different in comparison to diesel fuels derived from mineral oils suggesting also different emission behavior.
The identification and quantification of compounds in the gas phase becomes of increasing interest in the context of environmental protection, as well as in the analytical field. In this respect, the high extinction coefficients of vapours and gases in the ultraviolet wavelength region allow a very sensitive measurement system. In addition, the increased performance of the components necessary for setting up a measurement system, such as fibres, light sources and detectors has been improved. In particular the light sources and detectors offer improved stability, and the deep UV performance and solarisation resistance of fused silica fibres allow have been significantly optimized in the past years. Therefore a compact and reliable detection system with high measuring accuracy is developed. Within this paper possible applications of the system under development and recent results will be discussed.
This paper shows the results of the evaluation of two sets of mobile web design guidelines concerning mobile learning. The first set of guidelines is concerned with the usage of text on mobile device screens. The second set is concerned with the usage of images on mobile devices. The evaluation is performed by eye tracking (objective) as well as questionnaires and interviews (subjective) respectively.
Plant oils may be used as a sustainable, nearly CO2neutral fuel for diesel engines. This work investigates experimentally the particulate and gaseous emissions of diesel engines fuelled with different non-esterified, pure plant oils. The data are collected from three engines: a) Common rail 1.7 liter passenger car engine from Opel AG b) 12.8 liter truck engine from VOLVO c) Truck engine from MAN AG.
The emissions of the MAN engine have been used to perform AMES tests to analyze possible health impacts of plant oil operation. Finally, all emission results with plant oils have been compared to traditional gas oils.
Vergleich der hämodynamischen Reaktion auf VV-Delay Änderungen bei Sinusrhythmus und Vorhofflimmern
(2010)
AV delay (AVD) optimization can improve hemodynamics and avoid nonresponding to cardiac resynchronization therapy (CRT). AVD can be approximated by the sum of the individual implant-related interatrial conduction interval and a mean electromechanical interval of about 50ms. We searched for methods to facilitate automatic, implant-based AV delay optimization. In 25 patients (19m, 6f, age: 65±8yrs.) with Medtronic Insync III Marquis CRT-D series systems and left ventricular electrode at lateral or posterolateral wall, we determined interatrial conduction intervals by telemetric left ventricular tip versus superior vena cava coil electrogram (LVCE). Compared with esophageal measurements, the duration of optimal AV delay by LVCE showed good correlation (k=0.98, p=0.01) with a difference of 1.5±4.9ms, only. Therefore, LVCE is feasible to determine interatrial conduction intervals in order to automate AV delay optimization in CRT-D pacing promising increased accuracy compared to other algorithms.