Refine
Year of publication
- 2016 (43) (remove)
Document Type
- Conference Proceeding (31)
- Article (reviewed) (7)
- Article (unreviewed) (2)
- Book (1)
- Part of a Book (1)
- Master's Thesis (1)
Conference Type
- Konferenzartikel (27)
- Konferenz-Abstract (3)
- Sonstiges (1)
Language
- English (43) (remove)
Keywords
- Haustechnik (3)
- 6LoWPAN (2)
- Brennstoffzelle (2)
- Dünnschichtchromatographie (2)
- Eingebettetes System (2)
- Methanisierung (2)
- Algorithmus (1)
- Bellman Ford algorithm (1)
- Biogas (1)
- Biogasreaktor (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (26)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (14)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (9)
- INES - Institut für nachhaltige Energiesysteme (6)
- Fakultät Wirtschaft (W) (5)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (3)
- ACI - Affective and Cognitive Institute (1)
- WLRI - Work-Life Robotics Institute (1)
Open Access
- Closed Access (43) (remove)
Die Vision vom "Internet der Dinge" prägt seit Jahren Forschung und Entwicklung, wenn es um smarte Technologien und die Vernetzung von Geräten geht. In der Zukunft wird die reale Welt zunehmend mit dem Internet verknüpft, wodurch zahlreiche Gegenstände (Dinge) des normalen Alltags dazu befähigt werden, zu interagieren und sowohl online als auch autark zu kommunizieren. Viele Branchen wie Medizin, Automobilbau, Energieversorgung und Unterhaltungselektronik sind gleichermaßen betroffen, wodurch trotz Risiken auch neues wirtschaftliches Potential entsteht. Im Bereich "Connected Home" sind bereits Lösungen vorhanden, mittels intelligenter Vernetzung von Haushaltsgeräten und Sensoren, die Lebensqualität in den eigenen vier Wänden zu erhöhen. Diese Arbeit beschäftigt sich mit dem Thread Protokoll; einer neuen Technologie zur Integration mehrerer Kommunikationsschnittstellen innerhalb eines Netzwerks. Darüber hinaus wird die Implementierung auf Netzwerkebene (Network Layer) vorgestellt, sowie aufbereitete Informationen bezüglich verwendeter Technologien dargestellt.
Background: Cardiac resynchronization therapy (CRT) is an established therapy for heart failure (HF) patients (P) with reduced left ventricular (LV) ejection fraction and electrical interventricular desynchronization, but not all P improved clinically. The aim of the study was to evaluate electrical interventricular delay (IVD) to LV delay (LVD) ratio in atrial fibrillation (AF) CRT responder (R) and non-responder (NR).
Methods: AF P (n = 18, age 60.6 ± 11.4 years, 1 female, 17 males) with HF New York Heart Association (NYHA) class 3.0 ± 0.2, 25.3 ± 5.9 % LV ejection fraction and 157.8 ± 24.4 ms QRS duration (QRSD) were measured by surface ECG and focused transesophageal bipolar LV ECG before implantation of CRT pacemaker (n = 2) or CRT defibrillator (n = 16). IVD was measured between onset of QRS in the surface ECG and onset of LV signal in the LV ECG. LVD was measured between onset and offset of LV signal in the LV ECG.
Results: Electrical ventricular desynchronization in AF CRT P were 61.9 ± 26.9ms IVD, 80.6 ± 24.3ms LVD, 0.85 ± 0.41 IVD-LVD-ratio (Figure), 3.12 ± 1.89 QRSD-IVD-ratio and 2.07 ± 0.47 QRSD-LVD-ratio. There were 72.2 % AF CRT R (n = 13) with 64.2 ± 24.6ms IVD and 77.8 ± 21.6ms LVD with Pearson correlation to 0.89 ± 0.39 IVD-LVD-ratio (r = 0.87, P < 0.01; r = -0.69, P < 0.01), 2.82 ± 1.32 QRSD-IVD-ratio (r = -0.76, P < 0.01; r = 0.67, P = 0.011) and 2.13 ± 0.46 QRSD-LVD-ratio (r = 0.57, P = 0.041; r = -0.85, P < 0.01). There were 27.8% AF CRT NR (n = 5) with 56.0 ± 34.5ms IVD and 87.8 ± 31.9ms LVD without correlation to 0.74 ± 0.48 IVD-LVD-ratio, 3.88 ± 2.98 QRSD-IVD-ratio and 1.90 ± 0.48 QRSD-LVD-ratio. During 15.3 ± 13.1 month CRT follow-up, the AF CRT R NYHA class improved from 3.0 ± 0.2 to 2.2 ± 0.3 (P < 0.001). During 18.8 ± 20.7 month CRT follow-up, the AF CRT NR NYHA class not improved from 3 to 3.3 ± 0.97.
Laser pulses focused near the tip of an elastic wedge generate acoustic waves guided at its apex. The shapes of the acoustic wedge wave pulses depend on the energy and the profile of the exciting laser pulse and on the anisotropy of the elastic medium the wedge is made of. Expressions for the acoustic pulse shapes have been derived in terms of the modal displacement fields of wedge waves for laser excitation in the thermo-elastic regime and for excitation via a pressure pulse exerted on the surface. The physical quantity considered is the local inclination of a surface of the wedge, which is measured optically by laser-probe-beam deflection. Experimental results on pulse shapes in the thermo-elastic regime are presented and confirmed by numerical calculations. They pertain to an isotropic sharp-angle wedge with two wedge-wave branches and to a non-reciprocity phenomenon at rectangular silicon edges.
Covert channels have been known for a long time because of their versatile forms of appearance. For nearly every technical improvement or change in technology, such channels have been (re-)created or known methods have been adapted. For example, the introduction of hyperthreading technology has introduced new possibilities for covert communication between malicious processes because they can now share the arithmetic logical unit as well as the L1 and L2 caches, which enable establishing multiple covert channels. Even virtualization, which is known for its isolation of multiple machines, is prone to covert- and side-channel attacks because of the sharing of resources. Therefore, it is not surprising that cloud computing is not immune to this kind of attacks. Moreover, cloud computing with multiple, possibly competing users or customers using the same shared resources may elevate the risk of illegitimate communication. In such a setting, the “air gap” between physical servers and networks disappears, and only the means of isolation and virtual separation serve as a barrier between adversary and victim. In the work at hand, we will provide a survey on vulnerable spots that an adversary could exploit trying to exfiltrate private data from target virtual machines through covert channels in a cloud environment. We will evaluate the feasibility of example attacks and point out proposed mitigation solutions in case they exist.
Phenolic compounds, such as flavonoids and phenolic acids, are very important substances that occur in various medicinal plants. They show different pharmacological activities which might be useful in the therapy of many diseases. Phenolic compounds have achieved an increasing interest over the last years because these compounds are easily oxidized and, thus, act as strong antioxidants. We present the chemiluminescence of different phenolic compounds measured directly on high-performance thin-layer chromatography LiChrospher® plates using the oxalic acid derivative bis(2,4,6-trichlorophenyl) oxalate (TCPO) in conjunction with H2O2. Our results indicate that chemiluminescence intensity increases with an ascending number of phenolic groups in the molecule. The method can be used to detect phenolic compounds in beverages like coffee, tea, and wine.
The industry of the agave-derived bacanora, in the northern Mexican state of Sonora, has been growing substantially in recent years. However, this higher demand still lies under the influences of a variety of social, legal, cultural, ecological and economic elements. The governmental institutions of the state have tried to encourage a sustainable development and certain levels of standardization in the production of bacanora by applying different economical and legal strategies. However, a large portion of this alcoholic beverage is still produced in a traditional and rudimentary fashion. Beyond the quality of the beverage, the lack of proper control, by using adequate instrumental methods, might represent a health risk, as in several cases traditional-distilled beverages can contain elevated levels of harmful materials. The present article describes the qualitative spectral analysis of samples of the traditional-produced distilled beverage bacanora in the range from 0 cm−1 to 3500 cm−1 by using a Fourier Transform Raman spectrometer. This particular technique has not been previously explored for the analysis of bacanora, as in the case of other beverages, including tequila. The proposed instrumental arrangement for the spectral analysis has been built by combining conventional hardware parts (Michelson interferometer, photo-diodes, visible laser, etc.) and a set of self-developed evaluation algorithms. The resulting spectral information has been compared to those of pure samples of ethanol and to the spectra from different samples of the alcoholic beverage tequila. The proposed instrumental arrangement can be used the analysis of bacanora.
Flexible Three-dimensional Camera-based Reconstruction and Calibration of Tracked Instruments
(2016)
Navigated instruments commonly include applied parts, e.g. burrs or saw blades, that need to be calibrated with respect to the attached or integrated tracker. Since this calibration has to be very precise, it is often performed by the manufacturer. However, due to the great variety of instruments and the option to exchange the applied parts (e.g. burrs) there is a definite demand for flexible and generic calibration techniques. Furthermore, if we look into the medical field, there is also a need for calibrating sterile instruments. We propose a new and flexible camera-based calibration technique that addresses these demands by working contactlessly, precisely, and generically for a large variety of tracked instruments. This is realized using one or more tracked cameras which are calibrated with respect to an attached or integrated tracker. The tracked instrument is rotated in front of the camera(s) and its 3D geometry and surface are reconstructed from the 2D images in the coordinate system of the attached or integrated tracker. The 3D geometry of the navigated instrument was reconstructed with an accuracy of under 0.2 mm. The radius of a sphere-shaped instrument was reconstructed with an RMS deviation of 0.015mm.