Refine
Year of publication
- 2014 (32) (remove)
Document Type
- Article (reviewed) (32) (remove)
Has Fulltext
- no (32)
Keywords
- Intelligentes Stromnetz (4)
- Elektrolyt (3)
- Lithiumbatterie (3)
- Management (2)
- Netzwerk (2)
- Analyse (1)
- Anomalie (1)
- Arzneimittel (1)
- Aufbereitung (1)
- BACnet (1)
Institute
Open Access
- Closed Access (16)
- Open Access (3)
Pure component sorption isotherms of n-butane, isobutane, 1-butene and isobutene on the metal–organic framework (MOF) 3∞[Cu4(μ4-O)(μ2-OH)2(Me2trz-pba)4] at various temperatures between 283 K and 343 K and pressures up to 300 kPa are presented. The isotherms show a stepwise pore filling which is typical for structurally flexible materials with broad adsorption–desorption hysteresis loops. Gate opening pressures in their endemic characteristic depend on the used hydrocarbon gases. From all investigated gases only the isotherms of 1-butene present a second step at a relative pressure above p/p0 = 0.55. As a consequence, only 1-butene can fully open the framework resulting in a pore volume of 0.54 cm3 g−1. This result is in good agreement with the value of 0.59 cm3 g−1 calculated based on single crystal structure data. The isosteric heat of adsorption was calculated from the experimental isotherms for all C4-isomers. At low loadings the isosteric heat is in a narrow region between 41 and 49 kJ mol−1. Moreover, in situ XRD measurements at different relative hydrocarbon pressures were performed at 298 K for the C4-isomers. The differences in the pressure-depending powder diffraction patterns indicate phase transitions as a result of adsorption. Similar diffraction patterns were observed for all C4-hydrocarbons, except 1-butene, where the second step at higher relative pressure (p/p0 > 0.55) is accompanied by an additional phase transition. This powder pattern resembles that of the as-synthesized MOF material containing solvent molecules in the pore system. The resulting structural changes of the material during guest and pressure induced external stimuli are evidenced by the new coupled XRD adsorption equipment.
This paper presents new measurements of a bronze cast from the right hand of the famous Italian violin virtuoso Nicolò Paganini (1782-1840). These are compared to anthropometric standard values. In addition, detailed dorsal and palmar views of the cast are shown. With a middle finger length of 75 mm, the palm width is 60 mm and the hand length 152 mm, which is significantly below the 5% percentile of today's standard values. Also the finger length index (0.55), the ratio of finger length to palm length (0.98) and the ratio of finger length to palm width (1.25) are significantly above normal limits. Hence, Paganini had abnormal hand measurements with a very small palm and relatively "long" fingers. This remarkable constellation, among others, could have been advantageous for his amazing skills as a violinist.
Aqueous lithium–oxygen batteries are promising candidates for electric energy storage. In this paper we present and discuss a multiphase continuum model of an aqueous lithium–oxygen single cell including reactions and transport in a porous gas diffusion electrode (GDE). The model is parameterized using in-house half-cell experiments and available literature data on aqueous electrolytes. We validate our transport model with cyclic voltammetry and electrochemical impedance spectroscopy measurements over a wide range of temperatures (25, 40, 55 °C) and electrolyte concentrations (0.1–2 M). We observe very good agreement between simulations and measurements during oxygen reduction conditions. A sensitivity analysis of the validated model demonstrates the influence of the porous structure on GDE performance and gives directions for the future development of electrodes.
In 35 deutschen und 7 europäischen Büro- und Verwaltungsgebäuden wurden auf Basis von Monitoringkampagnen über mehrere Betriebsjahre Raum- und Außentemperaturwerte in zeitlich hoher Auflösung erfasst und der thermische Raumkomfort im Sommer standardisiert nach der Komfortnorm DIN EN 15251:2007-08 detailliert ausgewertet. Ergänzt wird die Auswertung um Kurzzeitmesskampagnen über zwei sehr warme Wochen im Sommer in unsanierten bzw. teilsanierten Bürogebäuden, errichtet im Zeitraum von 1960 bis 1975. Die untersuchten Gebäude mit ihrem jeweiligen Kühlkonzept lassen sich in sechs Kategorien einteilen: ohne Kühlung, passive, luftgeführte und wassergeführte Kühlung sowie Mixed-mode-Kühlung und Vollklimatisierung. Im Quervergleich aller Gebäude werden die Kühlkonzepte gleichermaßen nach dem thermischen Raumkomfort und thermischen Kühlenergiebezug bewertet. Detaillierte Komfortuntersuchungen nach der Europäischen Komfortnorm DIN EN 15251:2007-08 geben Hinweise auf die Wirksamkeit der eingesetzten Kühltechnologien in den jeweiligen Klimazonen. Daraus lassen sich Handlungsempfehlungen für die Planungspraxis und den Gebäudebetrieb ableiten.