Refine
Year of publication
- 2016 (52) (remove)
Document Type
- Article (reviewed) (52) (remove)
Has Fulltext
- no (52)
Is part of the Bibliography
- yes (52)
Keywords
- Energieversorgung (3)
- Computertomografie (2)
- Durchblutung (2)
- Lichtbogenofen (2)
- Lithium-Ionen-Akkumulator (2)
- Messtechnik (2)
- Radiologie (2)
- Schlafforschung (2)
- Ultraschall (2)
- Wärmeübertragung (2)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (30)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (15)
- INES - Institut für nachhaltige Energiesysteme (9)
- Fakultät Wirtschaft (W) (6)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (1)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (1)
Open Access
- Closed Access (10)
- Open Access (10)
- Closed (3)
Der Beitrag behandelt ausgewählte Themenkomplexe im Zusammenhang mit der Vorspannung von Schraubenverbindungen im Stahlbau. Es werden verschiedene Anwendungen und damit verbundene Aspekte beleuchtet und diskutiert, zum Beispiel die Schraubensicherung durch Vorspannung oder die Steifigkeit der Verbindung. Dem vorangestellt ist eine kurze Einführung in die mechanische Wirkung der Vorspannung in der Verbindung sowie eine Vorstellung der Vorspannverfahren.
In this study the dynamics and stability of thin and electrically conductive aqueous films under the influence of a time-periodic electric field are explored. With the help of analytical linear stability analysis for long wavelength disturbances, the stability threshold of the system as a function of various electrochemical parameters and transport coefficients is presented. The contributions of parameters like surface tension, disjoining pressure, electric double layer (Debye length and interfacial zeta potential), and unsteady Maxwell and viscous stresses are highlighted with the help of appropriate dimensionless groups. The physical mechanisms affecting the stability of thin films are detailed with the above-mentioned forces and parametric dependence of stability trends is discussed.
Bud type carbon nanohorns (CNHs) are composed of carbon and have a closed conical tip at one end protruding from an aggregate structure. By employing a simple oxidation process in CO2 atmosphere, it is possible to open the CNH tips which increases their specific surface area by four fold. These tip opened CNHs combine the microporous nature of activated carbons and the crystalline mesoporous character of carbon nanotubes. The results for the high pressure CO2 gas adsorption of tip opened CNHs are reported herein for the first time and are found to be superior to traditional CO2 adsorbents like zeolites. The modified CNHs are also found to be promising materials for lithium ion batteries and the performance is found to be on a par with carbon nanotubes and carbon nanofibers.
A new yield function for lamellar gray cast iron materials is proposed. The new model is able to describe the results of recently performed microstructure-based finite-element computations that resolve the three dimensional yield surface of three different gray cast irons. The yield function requires only the yield stress in tension and compression of the respective material as model parameters. Furthermore, the algorithmic formulation of the new model is assessed for numerical robustness and efficiency.
Passive solar elements for both direct and indirect gains, are systems used to maintain a comfortable living environment while saving energy, especially in the building energy retrofit and adaptation process. Sunspaces, thermal mass and glazing area and orientation have been often used in the past to guarantee adequate indoor conditions when mechanical devices were not available. After a period of neglect, nowadays they are again considered as appropriate systems to help face environmental issues in the building sector, and both international and national legislation takes into consideration the possibility of including them in the building planning tools, also providing economic incentives. Their proper design needs dynamic simulation, often difficult to perform and time consuming. Moreover, results generally suffer from several uncertainties, so quasi steady-state procedures are often used in everyday practice with good results, but some corrections are still needed. In this paper, a comparative analysis of different solutions for the construction of verandas in an existing building is presented, following the procedure provided by the slightly modified and improved Standard EN ISO 13790:2008. Advantages and disadvantages of different configurations considering thermal insulation, windows typology and mechanical ventilation systems are discussed and a general intervention strategy is proposed. The aim is to highlight the possibility of using sunspaces in order to increase the efficiency of the existing building stock, considering ease of construction and economic viability.
Energy Performance of Verandas in the Building Retrofit Process (PDF Download Available). Available from: https://www.researchgate.net/publication/303093420_Energy_Performance_of_Verandas_in_the_Building_Retrofit_Process [accessed Jul 5, 2017].
BACKGROUND:
While hearing aids for a contralateral routing of signals (CROS-HA) and bone conduction devices have been the traditional treatment for single-sided deafness (SSD) and asymmetric hearing loss (AHL), in recent years, cochlear implants (CIs) have increasingly become a viable treatment choice, particularly in countries where regulatory approval and reimbursement schemes are in place. Part of the reason for this shift is that the CI is the only device capable of restoring bilateral input to the auditory system and hence of possibly reinstating binaural hearing. Although several studies have independently shown that the CI is a safe and effective treatment for SSD and AHL, clinical outcome measures in those studies and across CI centers vary greatly. Only with a consistent use of defined and agreed-upon outcome measures across centers can high-level evidence be generated to assess the safety and efficacy of CIs and alternative treatments in recipients with SSD and AHL.
METHODS:
This paper presents a comparative study design and minimum outcome measures for the assessment of current treatment options in patients with SSD/AHL. The protocol was developed, discussed, and eventually agreed upon by expert panels that convened at the 2015 APSCI conference in Beijing, China, and at the CI 2016 conference in Toronto, Canada.
RESULTS:
A longitudinal study design comparing CROS-HA, BCD, and CI treatments is proposed. The recommended outcome measures include (1) speech in noise testing, using the same set of 3 spatial configurations to compare binaural benefits such as summation, squelch, and head shadow across devices; (2) localization testing, using stimuli that rove in both level and spectral content; (3) questionnaires to collect quality of life measures and the frequency of device use; and (4) questionnaires for assessing the impact of tinnitus before and after treatment, if applicable.
CONCLUSION:
A protocol for the assessment of treatment options and outcomes in recipients with SSD and AHL is presented. The proposed set of minimum outcome measures aims at harmonizing assessment methods across centers and thus at generating a growing body of high-level evidence for those treatment options.
Mit der Messung des Wärme- und Kälteverbrauchs im Labor gelingt es, sowohl thermisch träge als auch agile Flächentemperiersysteme unter praxisnahen, dynamischen Bedingungen messtechnisch zu bewerten. Werden Nutzwärme- und Nutzkältebedarf berechnet und ins Verhältnis zu den gemessenen Verbräuchen gesetzt, können die Aufwandzahlen für die Nutzenübergabe ece für verschiedene Flächentemperiersysteme und in Kombinationen mit anderen Übergabesystemen unter verschiedenen Nutzungsbedingungen und für unterschiedliche Betriebsführungsstrategien bestimmt werden. Damit stehen Aufwandszahlen auf Basis kalorischer Messungen zur Verfügung, die je nach Aufgabenstellung entweder produkt- oder objektbezogen in der Planung komplexer Energiekonzepte verwendet werden können und die tatsächlichen Aufwandszahlen eh, ce für den Heizfall bzw. ec, ce für den Kühlfall genauer als Literaturwerte bzw. projektbezogen beschreiben
Two closely related series of paddle-wheel-based triazolyl isophthalate MOFs are presented. Thermal and CO2 adsorption studies reveal network flexibility induced by alkyl substituents of the linker. By choice of the substituent, the pore volumes and pore diameters can be adjusted. Fine-tuning of the gate opening pressure and the hysteresis shape is possible by modulating the substitution pattern and by choice of the metal ion.
n this work a mathematical model for describing the performance of lithium-ion battery electrodes consisting of porous active material particles is presented. The model represents an extension of the Newman-type model, accounting for the agglomerate structure of the active material particles, here Li(Ni1/3Co1/3Mn1/3)O2 (NCM) and Li(Ni1/3Co1/3Al1/3)O2 (NCA). To this goal, an additional pore space is introduced on the active material level. The space is filled with electrolyte and a charge-transfer reaction takes place at the liquid-solid interface within the porous active material particles. Volume-averaging techniques are used to derive the model equations. A local Thiele modulus is defined and provides an insight into the potentially limiting factors on the active material level. The introduction of a liquid-phase ion transport within the active material reduces the overall transport losses, while the additional active surface area within the agglomerate lowers the charge-transfer resistance. As a consequence, calculated discharge capacities are higher for particles modeled as agglomerates. This finding is more pronounced in the case of high C-rates
MITK-OpenIGTLink for combining open-source toolkits in real-time computer-assisted interventions
(2016)
PURPOSE:
Due to rapid developments in the research areas of medical imaging, medical image processing and robotics, computer-assisted interventions (CAI) are becoming an integral part of modern patient care. From a software engineering point of view, these systems are highly complex and research can benefit greatly from reusing software components. This is supported by a number of open-source toolkits for medical imaging and CAI such as the medical imaging interaction toolkit (MITK), the public software library for ultrasound imaging research (PLUS) and 3D Slicer. An independent inter-toolkit communication such as the open image-guided therapy link (OpenIGTLink) can be used to combine the advantages of these toolkits and enable an easier realization of a clinical CAI workflow.
METHODS:
MITK-OpenIGTLink is presented as a network interface within MITK that allows easy to use, asynchronous two-way messaging between MITK and clinical devices or other toolkits. Performance and interoperability tests with MITK-OpenIGTLink were carried out considering the whole CAI workflow from data acquisition over processing to visualization.
RESULTS:
We present how MITK-OpenIGTLink can be applied in different usage scenarios. In performance tests, tracking data were transmitted with a frame rate of up to 1000 Hz and a latency of 2.81 ms. Transmission of images with typical ultrasound (US) and greyscale high-definition (HD) resolutions of [Formula: see text] and [Formula: see text] is possible at up to 512 and 128 Hz, respectively.
CONCLUSION:
With the integration of OpenIGTLink into MITK, this protocol is now supported by all established open-source toolkits in the field. This eases interoperability between MITK and toolkits such as PLUS or 3D Slicer and facilitates cross-toolkit research collaborations. MITK and its submodule MITK-OpenIGTLink are provided open source under a BSD-style licence ( http://mitk.org )