Refine
Year of publication
Document Type
Conference Type
- Konferenzartikel (11)
- Konferenz-Poster (1)
Has Fulltext
- no (22) (remove)
Is part of the Bibliography
- yes (22)
Keywords
- MPC (3)
- Crack opening stress (2)
- Herzrhythmusmodell (2)
- Katheterablation (2)
- Photovoltaic (2)
- Plasticity-induced crack closure (2)
- Automobilindustrie (1)
- Batteries (1)
- Blockchain (1)
- Chip-Karte (1)
Institute
- CRT - Campus Research & Transfer (22) (remove)
Open Access
- Closed (8)
- Open Access (8)
- Closed Access (6)
- Bronze (3)
In this paper, a complete passive transponder device has been discussed which is meant to monitor leakage in silicone breast implants. The passive tag operates in the HF frequency range of 13.56MHz using RFID ISO 15693 standard. The complete system consists of the transponder, reader and a PC. This paper focusses on the development of such a state of the art passive RFID transponder to monitor the wellness of the silicone breast implants periodically in order to detect leakage in the same. Keyword: RFID (Radio frequency identification device), EM (Electromagnetic) field, Passive Transponder, Silicone breast implants.
Die Auswirkungen der digitalen Transformation werden meist im Kontext von Wirtschaftsunternehmen diskutiert und auf die Blickwinkel Wirtschaft und Technologie fokussiert. Der digitale Wandel hat jedoch auch die Führungsaufgaben in vielen gesellschaftlichen Bereichen verändert, wie am Beispiel Schule und Kommunalverwaltung aufgezeigt wird.
Es wird der Einsatz von Doppelschichtkondensatoren mit Kapazitäten bis zu 1500 F für den Einsatz in der Kraftfahrzeugtechnik und der Umwelttechnik diskutiert. Dabei werden sowohl die Verwendung zur Entlastung der Batterie bei Stromspitzen wie auch die Einsatzmöglichkeiten in alltagstauglichen Hybridfahrzeugen beleuchtet. Voraussetzung ist die Kombination mit einer ausgereiften Leistungselektronik. Doppelschichtkondensatoren verfügen über eine Leistungsdichte von derzeit etwa 2 Wh/kg, wobei weitere Steigerungen zu erwarten sind. Damit sind sie als Ergänzung oder sogar als Ersatz für Akkumulatoren einsetzbar. Da die Spannung vom Ladezustand abhängig ist, muß eine genaue Überwachung und Regelung stattfinden, andererseits wird dadurch die Ladezustandsdiagnose erheblich vereinfacht. Durch Kondensatorpufferung mittels Stellglied kann die Batterie bei starken Lastwechseln entlastet werden. In Elektrofahrzeugen läßt sich so die hohe Beschleunigungsleistung erbringen, die Batterie kann dann schwächer ausgelegt werden. Auch kann sich die Bremsenergie durch Kondensatoren besser zurückgewonnen werden. Die Möglichkeit der Entladung bis auf 0 V eröffnet ein wesentlich größeres Spannungsfenster. Der Einsatz in Hybridfahrzeugen mit kombiniertem Elektroantrieb/Verbrennungsmotor wird noch untersucht. Zur Untersuchung der elektronischen Systeme wurde ein Simulationsprogramm entwickelt, mit dem u. a. die Abhängigkeit von Energiedichte und spezifischer Konstantleistung als Ragone-Diagramm dargestellt werden kann.
The increase in households with grid connected Photovoltaic (PV) battery system poses challenge for the grid due to high PV feed-in as a result of mismatch in energy production and load demand. The purpose of this paper is to show how a Model Predictive Control (MPC) strategy could be applied to an existing grid connected household with PV battery system such that the use of battery is maximized and at the same time peaks in PV energy and load demand are reduced. The benefits of this strategy are to allow increase in PV hosting capacity and load hosting capacity of the grid without the need for external signals from the grid operator. The paper includes the optimal control problem formulation to achieve the peak shaving goals along with the experiment set up and preliminary experiment results. The goals of the experiment were to verify the hardware and software interface to implement the MPC and as well to verify the ability of the MPC to deal with the weather forecast deviation. A prediction correction has also been introduced for a short time horizon of one hour within this MPC strategy to estimate the PV output power behavior.
In rural low voltage grid networks, the use of battery in the households with a grid connected Photovoltaic (PV) system is a popular solution to shave the peak PV feed-in to the grid. For a single electricity price scenario, the existing forecast based control approaches together with a decision based control layer uses weather and load forecast data for the on–off schedule of the battery operation. These approaches do bring cost benefit from the battery usage. In this paper, the focus is to develop a Model Predictive Control (MPC) to maximize the use of the battery and shave the peaks in the PV feed-in and the load demand. The solution of the MPC allows to keep the PV feed-in and the grid consumption profile as low and as smooth as possible. The paper presents the mathematical formulation of the optimal control problem along with the cost benefit analysis . The MPC implementation scheme in the laboratory and experiment results have also been presented. The results show that the MPC is able to track the deviation in the weather forecast and operate the battery by solving the optimal control problem to handle this deviation.
Die Katheterablation mit Hochfrequenzstrom (HF) ist der Goldstandard für die Therapie vieler kardi-aler Tachyarrhythmien. Bei der HF-Ablation entstehen Temperaturen zwischen 50 °C und 70 °C, wo-durch bestimmte Strukturen im Herzgewebe gezielt zerstört werden können. Ziel der Studie ist, die HF-Ablation und deren Wärmeausbreitung in Bezug auf die zugeführte Leistung mit unterschiedli-chem Elektrodenmaterial und Elektrodengröße bei supraventrikülären Tachykardien zu simulieren.
A new electronic capsule with bidirectional communication system is being developed for multi-task application. The capsule is designed to be a platform for medical assistant application inside the body. The designed telemetry unit is a synchronous bidirectional communication block using continuous phase DQPSK of 115 kHz low carrier frequency for inductive data transmission suited for human body energy transfer. The communication system can assist the electronic pill to trigger an actuator for drug delivery, to record temperature, or to measure pH of the body. It consists additionally to a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA. A final layout of the complete chip design is still under progress.
Digitalisierung ist heute allgegenwärtig. Wo im Privaten bereitwillig neue digitale Tools, Apps und Funktionen genutzt werden, tun sich Unternehmen in der Umsetzung von Digitalisierungsprojekten oft schwer. Dieser Beitrag beleuchtet die Motive für Digitalisierungsvorhaben, ihre Hürden sowie die Auswirkung auf die Arbeitsbelastung von Mitarbeitenden und versucht in der Verknüpfung mit den Grundprinzipien des Kontinuierlichen Verbesserungsprozesses, Handlungsempfehlungen für eine erfolgreiche Umsetzung dieser abzuleiten.
In recent times, the energy consumed by buildings facilities became considerable. Efficient local energy management is vital to deal with building power demand penalties. This operation becomes complex when a hybrid energy system is included in the power system. This study proposes new energy management between photovoltaic (PV) system, Battery Energy Storage System (BESS) and the power network in a building by controlling the PV/BESS inverter. The strategy is based on explicit model predictive control (MPC) to find an optimal power flow in the building for one-day ahead. The control algorithm is based on a simple power flow equation and weather forecast. Then, a cost function is formulated and optimised using genetic algorithms-based solver. The objective is reducing the imported energy from the grid preventing the saturation and emptiness of BESS. Including other targets to the control policy as energy price dynamic and BESS degradation, MPC can optimise dramatically the efficacy of the global building power system. The strategy is implemented and tested successfully using MATLAB/SimPowerSystems software, compared to classical hysteresis management, MPC has given 10% in energy cost economy and 25% improvement in BESS lifetime.
A platform of an electronic capsule is being developed for multi-task medical assistant application. It includes a near field telemetry unit for bidirectional communication system of 115 KHz low carrier frequency for inductive data transmission suited for human body energy transfer. The system triggers an actuator for drug delivery in various time and release forms via wireless external control, it has the ability to record temperature, measure pH of the body (additional sensors), and retrieve data to the outside. It consists of a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA. A final layout of the complete chip design is still under progress.