Refine
Year of publication
Document Type
- Article (reviewed) (17)
- Conference Proceeding (16)
- Report (4)
- Patent (3)
- Book (1)
- Part of a Book (1)
- Article (unreviewed) (1)
Conference Type
- Konferenz-Abstract (14)
- Konferenzartikel (2)
Has Fulltext
- no (43) (remove)
Is part of the Bibliography
- yes (43)
Keywords
- Lithiumbatterie (5)
- Brennstoffzelle (2)
- Durchfluss (2)
- Hochtemperaturbrennstoffzelle (2)
- Lithium-ion battery (2)
- Polymere (2)
- Abgas (1)
- Ageing (1)
- Akkumulator (1)
- Batterieaufladung (1)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (43) (remove)
Open Access
- Open Access (24)
- Closed Access (10)
- Closed (1)
- Diamond (1)
The durability of polymer electrolyte membrane fuel cells (PEMFC) is governed by a nonlinear coupling between system demand, component behavior, and physicochemical degradation mechanisms, occurring on timescales from the sub-second to the thousand-hour. We present a simulation methodology for assessing performance and durability of a PEMFC under automotive driving cycles. The simulation framework consists of (a) a fuel cell car model converting velocity to cell power demand, (b) a 2D multiphysics cell model, (c) a flexible degradation library template that can accommodate physically-based component-wise degradation mechanisms, and (d) a time-upscaling methodology for extrapolating degradation during a representative load cycle to multiple cycles. The computational framework describes three different time scales, (1) sub-second timescale of electrochemistry, (2) minute-timescale of driving cycles, and (3) thousand-hour-timescale of cell ageing. We demonstrate an exemplary PEMFC durability analysis due to membrane degradation under a highly transient loading of the New European Driving Cycle (NEDC).
The DMFC is a promising option for backup power systems and for the power supply of portable devices. However, from the modeling point of view liquid-feed DMFC are challenging systems due to the complex electrochemistry, the inherent two-phase transport and the effect of methanol crossover. In this paper we present a physical 1D cell model to describe the relevant processes for DMFC performance ranging from electrochemistry on the surface of the catalyst up to transport on the cell level. A two-phase flow model is implemented describing the transport in gas diffusion layer and catalyst layer at the anode side. Electrochemistry is described by elementary steps for the reactions occurring at anode and cathode, including adsorbed intermediate species on the platinum and ruthenium surfaces. Furthermore, a detailed membrane model including methanol crossover is employed. The model is validated using polarization curves, methanol crossover measurements and impedance spectra. It permits to analyze both steady-state and transient behavior with a high level of predictive capabilities. Steady-state simulations are used to investigate the open circuit voltage as well as the overpotentials of anode, cathode and electrolyte. Finally, the transient behavior after current interruption is studied in detail.
Seven cell design concepts for aqueous (alkaline) lithium–oxygen batteries are investigated using a multi-physics continuum model for predicting cell behavior and performance in terms of the specific energy and specific power. Two different silver-based cathode designs (a gas diffusion electrode and a flooded cathode) and three different separator designs (a porous separator, a stirred separator chamber, and a redox-flow separator) are compared. Cathode and separator thicknesses are varied over a wide range (50 μm–20 mm) in order to identify optimum configurations. All designs show a considerable capacity-rate effect due to spatiotemporally inhomogeneous precipitation of solid discharge product LiOH·H2O. In addition, a cell design with flooded cathode and redox-flow separator including oxygen uptake within the external tank is suggested. For this design, the model predicts specific power up to 33 W/kg and specific energy up to 570 Wh/kg (gravimetric values of discharged cell including all cell components and catholyte except housing and piping).
Electrochemical impedance spectroscopy (EIS) is a widely-used diagnostic technique to characterize electrochemical processes. It is based on the dynamic analysis of two electrical observables, that is, current and voltage. Electrochemical cells with gaseous reactants or products (e.g., fuel cells, metal/air cells, electrolyzers) offer an additional observable, that is, the gas pressure. The dynamic coupling of current and/or voltage with gas pressure gives rise to a number of additional impedance definitions, for which we have introduced the term electrochemical pressure impedance spectroscopy (EPIS) [1,2]. EPIS shows a particular sensitivity towards transport processes of gas-phase or dissolved species, in particular, diffusion coefficients and transport pathway lengths. It is as such complementary to standard EIS, which is mainly sensitive towards electrochemical processes. This sensitivity can be exploited for model parameterization and validation. A general analysis of EPIS is presented, which shows the necessity of model-based interpretation of the complex EPIS shapes in the Nyquist plot (cf. Figure). We then present EPIS simulations for two different electrochemical cells: (1) a sodium/oxygen battery cell and (2) a hydrogen/air fuel cell. We use 1D or 2D electrochemical and transport models to simulate current excitation/pressure detection or pressure excitation/voltage detection. The results are compared to first EPIS experimental data available in literature [2,3].
Mass transfer phenomena in membrane fuel cells are complex and diversified because of the presence of complex transport pathways including porous media of very different pore sizes and possible formation of liquid water. Electrochemical impedance spectroscopy, although allowing valuable information on ohmic phenomena, charge transfer and mass transfer phenomena, may nevertheless appear insufficient below 1 Hz. Use of another variable, that is, back pressure, as an excitation variable for electrochemical pressure impedance spectroscopy is shown here a promising tool for investigations and diagnosis of fuel cells.