Refine
Year of publication
Document Type
- Bachelor Thesis (131) (remove)
Has Fulltext
- yes (131)
Is part of the Bibliography
- no (131)
Keywords
- Biomechanik (15)
- Bewegungsanalyse (6)
- Schluckspecht (6)
- Leichtbau (5)
- Ganganalyse (4)
- Hocheffizienzfahrzeug (4)
- Konstruktion (4)
- Medizintechnik (4)
- Elektromotor (3)
- Kreuzband (3)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (131) (remove)
Open Access
- Closed Access (66)
- Closed (53)
- Open Access (12)
- Diamond (1)
The aim of this bachelor thesis is to introduce a product data management (PDM) system to reduce the current difficulties in the project team workflow. The main objective is to reduce or prevent problems in the project team's collaboration processes by establishing a centralized, structured data repository.
The process to achieve this goal was to first talk to the project team and monitor professors to find the most effective strategies. Early research on PDM/PLM (Product Lifecycle Management) was conducted through literature reviews, online searches, thesis reviews, and video resources.
In order to gain a comprehensive understanding of PDM systems, the thesis used a combination of group discussions and literature reviews. The emphasis was on the practical application, which included the customization of configurations.
Um den Prozess der Direktreduktion von Eisenerz computergestützt zu simulieren, werden mathematische Modelle, zur Beschreibung von Gas-Feststoff-Reaktionen, in Python implementiert. In der vorliegenden Arbeit wird ein einzelnes Pellet aus Eisenerz, welches sich in einem Gasstrom aus reinem Wasserstoff befindet, betrachtet. Es werden mehrere Modellansätze aus der Literatur miteinander verglichen und davon geeignete zur recheneffizienten Implementierung ausgewählt. Die entwickelte Simulationssoftware besitzt eine grafische Oberfläche und bietet die Auswahl aus drei Modellen mit unterschiedlichem Detaillierungsgrad. Diese sind vollständig parametriert und die meisten Parameter werden temperaturabhängig bestimmt oder sind frei wählbar. Die Durchführung von Parameterstudien ist über die lineare Variierung eines beliebigen Parameters möglich. Die Ergebnisse der Simulation können dann in Abhängigkeit der Zeit dargestellt oder im CSV-Format exportiert werden. Die Rechenmodelle sind in einem separaten Python-Modul zusammengefasst und können einfach in eine übergeordnete Modellierung eingebaut werden. Zur Validierung erfolgt ein Abgleich mit experimentellen Literaturdaten. Abschließend werden die Stärken und Schwächen der implementierten Modelle gegenübergestellt und bewertet.
Rückenschmerzen sind ein weit verbreitetes Problem in der deutschen Gesellschaft. In der Mehrzahl der Fälle von Schmerzen im unteren Rücken ist es schwierig, eine spezifische nozizeptive Ursache zu finden. Aus vorherigen Studien ist bekannt, dass manuelles Heben eine Belastung für die Wirbelsäule darstellen kann. Die Geschwindigkeit der Hebebewegung spielt eine Rolle, ebenso wie Gewicht und Stabilität der Gelenke und Gliedmaßen.
Ziel dieser Arbeit ist die Analyse der Veränderungen in der Kinematik der Lendenwirbelsäule, der Hüfte und des Knies beim Heben von Lasten mit unterschiedlichen Geschwindigkeiten und Gewichten. Für diese Arbeit wurden die kinematischen Daten von insgesamt 79 Personen ausgewertet. Die Stichprobe bestand aus 20 asymptomatischen Frauen, 22 asymptomatischen Männern, 19 Frauen mit chronischen Rückenschmerzen und 18 Männern mit chronischen Rückenschmerzen. Die Daten wurden mit einem 3D-Bewegungsanalysesystem in Verbindung mit einem Set passiver Marker aufgenommen.
Es wurde kein signifikanter Effekt auf die mittleren maximalen Gelenkwinkel durch den Vergleich der geschlechtlich gemischten Gruppe mit Rückenschmerzen mit asymptomatischen Personen festgestellt, im Vergleich des Verhältnisses zwischen lumbaler Bewegung zu Beckenbewegungen (L/P-ratio) konnten signifikante Unterschiede ermittelt werden. Der Vergleich der Geschlechter zeigte signifikante Unterschiede für den lumbopelvinen Rhythmus. Für die Parameter Gewicht und Geschwindigkeit wurde kein signifikanter Effekt erfasst.
Das Ziel der vorliegenden Arbeit ist die Beantwortung der Frage, wie sich eine individuelle Fußbettung auf die Druckverteilung im Fuß und das körperliche Wohlbefinden im Allgemeinen auswirkt. Zu Anfang stehen die Nullhypothesen, dass durch eine solche Einlage keine Veränderungen in der Druckverteilung zu erwarten sind.
Um die Forschungsfrage zu beantworten, wurde eine experimentelle interventionelle Pilotstudie mit einer Kohorte von neun Probanden ohne orthopädische Probleme durchgeführt, die alle eine individuelle Schuheinlage erhielten. Die plantare Druckverteilung im Schuh wurde einmal ohne und einmal mit der Einlage sowohl statisch als auch dynamisch erfasst. Die Ergebnisse wurden anschließend verglichen. Die dynamische Datenerfassung beinhaltete die folgenden Konditionen: geradeaus Gehen, Gehen im Kreis (links- und rechtsherum), Stehen und der Transfer einer Kiste mit sich drehendem Oberkörper. Gleichzeitig wurde das Wohlbefinden der Probanden mit verschiedenen Fragebögen erfasst.
Die Anwendung einer individuellen Einlage zeigte im Bereich des medialen Mittelfußes einen Druckanstieg von über 100%, der Rückfuß wurde während des Stehens und Gehens entlastet. Der Vorfuß wurde während des Stehens teilweise mehr belastet. Diese Veränderungen können unter Umständen auf das Einführen der Längsgewölbestütze in der Einlage zurückgeführt werden. Die Auswertung der Fragebögen zu dieser Studie ergab, dass sich speziell für die Füße das Wohlbefinden leicht zum Schlechteren änderte, andere Bereiche, welche in den Fragebögen eruiert wurden, zeigten keine nennenswerten Veränderungen auf.
Daraus wird geschlossen, dass eine Schuheinlage die Druckverteilung in der Fußsohle stark verändern kann. Weiterführende Studien könnten den Einfluss der Einlage im Allgemeinen und der Wirkungsweise einer Längsgewölbestütze im Besonderen mit kinematischen Daten weiter belegen. Längerfristige Studien könnten die Langzeitwirkung von Einlagen auf das Wohlbefinden genauer erforschen.
Chitin ist nach Cellulose, das am zweit häufigsten vorkommende Biopolymer auf der Erde und erlangt durch die positiven Eigenschaften seiner Oligomere immer mehr an Aufmerksamkeit in der Industrie. Derzeit werden Chitin-Oligomere rein chemisch mittels starker Säurebehandlung gewonnen. Alternativ können Endo- und Exochitinasen für eine umweltfreundlichere Hydrolyse eingesetzt werden. In dieser Arbeit wurden drei fungale Endochitinasen aus den Ursprungsorganismen Trichoderma harzianum (Chit33-TH), Trichoderma asperellum (Chit36-TA) und Myceliophthora thermophila (Chit46-MT) in Pichia pastoris rekombinant exprimiert, mittels Ni-NTA-Affinitätschromatographie und Dialyse aufgereinigt und biochemisch charakterisiert. Dabei zeigten die Chitinasen maximale spezifische Umsatzgeschwindigkeiten von 16 (Chit33-TH), 50 (Chit36-TA) und 98 nkat/mg (Chit46-MT). Die Endochitinasen hatten nach der Deglykosylierung ein molekulares Gewicht von 33 (Chit33-TH), 36 (Chit36-TA) und 46 kDa (Chit46-MT). Die pH-Optima und Temperaturmaxima lagen für alle drei Enzyme bei einem pH-Wert von 4,5 und 50 °C, zudem waren sie bei 45 bis 50 °C für 15 Minuten temperaturstabil. Detergenzien und Kationen wie Cu2+, Mn2+, Co2+ und Zn2+ hatten einen inhibierenden Effekt ab 1 mM. Höhere Ca2+-Konzentrationen ab 10 mM reduzierten die Enzymaktivität um bis zu 30 %. Eine Produktinhibition mit N-Acetylglucosamin konnte nicht festgestellt werden. Bei allen rekombinanten Enzymen konnte mittels DNS-Assay die Freisetzung von reduzierenden Zuckerenden und somit geeignete Eigenschaften kolloidales Chitin zu wasserlösliche ChitinOligomere umzuwandeln, nachgewiesen werden. Insbesondere Chit46-MT erreichte nach 24 h einen Hydrolysegrad bis zu 96 % und bewies, dass eine enzymatische Hydrolyse für die industrielle Chitin-Oligomerproduktion nutzbar ist.
One of the main problematics of the seals tests is the time and money consuming they are. Up to now, there are few tries to do a digitalisation of a test where the seals behaviour can be known.
This work aims to digitally reproduce a seal test to extract their behaviour when working under different operation conditions to see their impact on the pimp’s efficiency. In this thesis, due to the Lomaking effect, the leakage and the forces applied on the stator will be the base of analysis.
First of all, among all the literature available for very different kind of seals and inner patterns, it has been chosen the most appropriate and precise data. The data chosen is “Test results for liquid Damper Seals using a Round-Hole Roughness Pattern for the Stator” from Fayolle, P. and “Static and Rotordynamic Characteristics of Liquid Annular Seals with Circumferentially/Grooved Stator and Smooth Rotor using three levels of circumferential Inlet-Fluid” from Torres J.M.
From the literature, dimensions of the test rig and the seals will be extracted to model them into a 3D CAD software. With the 3D CAD digitalisation, the fluid volumes for a rotor-centred position, meaning without eccentricity, will be extracted, and used. The following components have been modelled:
- Smooth Annular Liquid Seal (Grooved Rotor)
- Grooved Annular Liquid Seal (Smooth Rotor)
- Round-Hole Pattern Annular Liquid Seal (𝐻𝑑=2 𝑚𝑚) (Smooth Rotor)
- Straight Honeycomb Annular Liquid Seal (Smooth Rotor)
- Convergent Honeycomb Annular Liquid Seal (Smooth Rotor)
- Smooth Rotor / Smooth Annular Liquid Seal (Smooth Rotor)
As there is just one test rig, all the components have been adapted to the different dimensions of the seals by referencing some measures. This allows to test any seal with the same test rig.
Afterwards a CFD simulation that will be used to obtain leakage and stator forces. The parameters that will be changed are the rotational velocity of the fluid (2000 rpm, 4000 rpm, and 6000 rpm) and the pressure drop (2,068 bar, 4,137 bar, 6,205 bar, and 8,274 bar).
Those results will be compared to the literature ones, and they will determine if digitalisation can be validated or not. Even though the relative error is higher than 5% but the tendency is the same and it is thought that by changing some parameters the test results can be even closer to the literature ones.
To date, many experiments have been performed to study how the internal geometrical shapes of the annular liquid seal can reduce internal leakage and increase pump efficiency. These can be time-consuming and expensive as all rotordynamic coefficients must be determined in each case.
Nowadays, accurate simulation methods to calculate rotordynamic coefficients of annular seals are still rare. Therefore, new numerical methods must be designed and validated for annular seals.
The present study aims to contribute to this labour by providing a summary of the available test rig and seals dimensions and experimental results obtained in the following experiments:
− Kaneko, S et al., Experimental Study on Static and Dynamic Characteristics of Liquid Annular Convergent-Tapered Seals with Honeycomb Roughness Pattern (2003) [1] − J. Alex Moreland, Influence of pre-swirl and eccentricity in smooth stator/grooved rotor liquid annular seals, static and rotordynamic characteristics (2016) [2]
A 3D CAD simulation with Siemens NX Software of the test rig used in J. Alex Moreland’s experiment has been made. The following annular liquid seals have also been 3D modelled, as well as their fluid volume:
− Smooth Annular Liquid Seal (SS/GR) (J. Alex Moreland experiment)
− Grooved Annular Liquid Seal (GS/SR)
− Round-Hole Pattern Annular Liquid Seal (𝐻𝑑=2 mm) (GS/SR)
− Straight Honeycomb Annular Liquid Seal (GS/SR)
− Convergent Honeycomb Annular Liquid Seal (No. 3) (GS/SR)
− Smooth Annular Liquid Seal (SS/SR) (S. Kaneko experiment)
In the case of the seals used in S. Kaneko’s experiments, the test rig has been adapted to each seal, defining interpart expressions which can be easily modified.
Afterwards, it has been done a CFD simulation of the Smooth Annular Liquid Seal using Ansys CFX Software. To do so, the fluid volume geometry has been simplified to do a first approximation. Results have been compared for an eccentricity 𝜀0=0.00 for the following ranges of rotor speeds and differential of pressure:
− Δ𝑃= 2.07, 4.14, 6.21, and 8.27 bar,
− 𝜔= 2, 4, 6 and 8 krpm.
Even results obtained have the same trend as the one proportionated by the literature, they cannot be validated as the error is above 5%. It is also observed that as the pressure drop increases, the relative error decreases considerably.
In dieser Bachelorarbeit wurde eine Studie zum Dehnungsverhalten von Schuhen mit elastischem Obermaterial beim Gehen und Laufen bei verschiedenen Geschwindigkeiten durchgeführt. Aktuell gibt es auf diesem Gebiet keine belastbaren Daten. Hierfür wurde von 33 Probandinnen und Probanden mit vier verschiedenen Schuhgrößen die Dehnung des Schuhobermaterials durch markerbasiertes Motion Capturing aufgenommen. Hierzu wurde eine Markerkette von insgesamt 6 Markern über dem Mittelfußbereich angebracht. Auf einem Laufband wurden im Gehen drei Geschwindigkeiten zwischen 1,0 m/s und 1,5 m/s und im Laufen sieben Geschwindigkeiten zwischen 1,5 m/s und 4,5 m/s aufgenommen. Die Datenauswertung erfolgte zum Großteil mittels von Matlab. Die Ergebnisse zeigen für die maximale Dehnung des Obermaterials im Gehen signifikante Unterschiede von p < 0,001. Auch das Laufen zeigt diese Signifikanz jedoch ausschließlich in den Vergleichen der niedrigen Laufgeschwindigkeiten. Die Dehnungsgeschwindigkeit zeigt im Gehen und in den meisten Bereichen des Laufens eine Signifikanz von p < 0,001. Die Ergebnisse der Dehnungsbeschleunigung weisen ebenfalls eine Signifikanz von p < 0,001 auf. Die Betrachtung der Teilbereiche der Markerkette zeigt in der Dehnung und der Dehnungsgeschwindigkeit Signifikanzen von p < 0,001. Die größte Dehnung entstand im mittleren Markerbereich, wohingegen die Randbereiche signifikant weniger gedehnt wurden. Die Dehnungsgeschwindigkeit zeigt jedoch eine signifikant höhere Geschwindigkeit in den Randbereichen im Vergleich zu dem mittleren Bereich. Im direkten Vergleich zwischen Gehen und Laufen zeigt sich keine Signifikanz. Nicht signifikant sind außerdem die verschiedenen Schuhgrößen im Vergleich zueinander. Die Ergebnisse zeigen, dass die Laufgeschwindigkeit einen Einfluss auf das Dehnungsverhalten bezüglich Dehnung, Dehnungsgeschwindigkeit und Dehnungsbeschleunigung hat.
Zur ergonomischen Unterstützung von Industriearbeitern werden zunehmend Exoskelette eingesetzt. Studien über die Wirkung und den Einfluss von Exoskeletten auf den Körper sind jedoch rar. Diese Arbeit beschäftigt sich daher mit der Wirkung des Rückenexoskeletts BionicBack des deutschen Exoskelett Herstellers hTRIUS auf die Wirbelsäulenkrümmung bei industriellen Hebearbeiten. Im Speziellen wird die Wirbelsäulenkrümmung beim Umpalettieren aus drei verschiedenen Hebehöhen (91 cm, 59 cm, 15 cm) mit Hilfe eines markerbasierten 3D Motion Capture Systems untersucht. Um den Versuchsaufbau alltagsnah und realistisch zu gestalten, wurde diese Pilotstudie in Kooperation mit der Firma Zehnder am Standort Lahr durchgeführt, die sowohl die Probanden als auch den Versuchsaufbau zur Verfügung stellte. Vier gesunde männliche Probanden mit einem durchschnittlichen Alter von 39,5 Jahren (SD = 6,5), einem durchschnittlichen Körpergewicht von 72,75 kg (SD = 7,1) und einer durchschnittlichen Körpergröße von 175 cm (SD = 2,6) wurden in zwei Schichten eingeteilt. Mit den Probanden wurden vor und nach der Schicht sowie an zwei aufeinander folgenden Tagen Messungen durchgeführt, wobei an einem Tag das BionicBack während der Arbeit und der Messung getragen wurde und am an-deren Tag nicht. Während einer Messung nahmen die Testpersonen ein Paket mit einem Gewicht von 21,1 kg dreimal von jeder Hebehöhe von einer Palette auf und legten es auf einer anderen ab. Anschließend wurde die Krümmung der Wirbelsäule am tiefsten Punkt der Hebebewegung untersucht, wobei die Gesamtkrümmung in dieser Position durch die Addition von drei repräsentativen Segmentwinkeln dargestellt wird. Die Abweichung dieser Gesamtkrümmungen in der tiefsten Beugeposition von der individuellen neutralen Wirbelsäulenstellung der Probanden im Stehen ergeben die Werte, die zwischen den einzelnen Versuchsbedingungen verglichen werden. Die Ergebnisse zeigen, dass das BionicBack den Abstand zur Neutralstellung bzw. die Gesamtkrümmung des Rückens im Vergleich zu ohne BionicBack bis zu -11,5° (Median: -11,5° (SD = 5,2); Mittelwert: -8,4° (SD = 6,4)) entsprechend -30% vor der Schicht und bis zu -5,6° (Median: -5,6° (SD = 3,5); Mittelwert: -4,1° (SD = 5,4)) ent-sprechend -17% nach der Schicht reduzieren kann. Die Betrachtung der einzelnen Segmentwinkel zeigt, dass die Reduzierung des Abstandes von der Neutralstellung hauptsächlich im Lendenwirbelbereich stattfindet. Der Vergleich der Wirbelsäulen-krümmung vor und nach der Schicht ohne BionicBack zeigt, dass die Wirbelsäulen-krümmung nach der Schicht, mit Ausnahme der tiefsten Hebehöhe, eine größere Abweichung von der Neutralstellung aufweist als vor der Schicht. Der Vergleich mit BionicBack zeigt, dass die Wirbelsäulenkrümmung nach der Schicht mit Ausnahme der niedrigsten Hubhöhe nicht bzw. weniger von der Neutralstellung abweicht als vor der Schicht. Aufgrund der Ergebnisse wird vermutet, dass das BionicBack durch die Unterstützung einer neutraleren Rückenhaltung das Verletzungsrisiko reduzieren kann. Des Weiteren wird vermutet, dass die Muskelermüdung während einer Arbeitsschicht einen Einfluss auf die Wirbelsäulenkrümmung beim Heben hat. Es wird angenommen, dass dieser Einfluss durch das BionicBack reduziert werden kann. Allerdings dürfen die Grenzen dieser Pilotstudie nicht außer Acht gelassen werden. Sei es die Anzahl der Versuchspersonen, die keine Aussage über die Allgemeingültigkeit zu-lässt und keine effektive statistische Analyse erlaubt, oder systematische Fehler, die aufgrund der Modellvereinfachung und der Methodik auftreten können. Weitere Untersuchungen sind erforderlich, um die Ergebnisse zu validieren. Diese Arbeit soll die Grundlage für weitere Studien mit einer weiterentwickelten Methodik und einer größeren Anzahl von Probanden bilden.
In dieser Arbeit wird die Entwicklung einer Methode zur Messung von Bodenreaktionskräften bei menschlicher Lokomotion auf variablen Untergründen behandelt. Das Ziel dieser Arbeit ist es, unter realistischen Bedingungen eine Ganganalyse in einem Biomechaniklabor durchführen zu können.
Bisher ist es nicht möglich in einem Biomechaniklabor verschiedene Untergründe nach einer bestimmten Methode auszutauschen, womit Szenarien im Alltag besser simuliert werden können.
Um dieses Ziel zu erreichen wurde ein geeignetes Konzept für die Fertigung der benötigten Bodenplatten und Bodenbeläge erstellt. Darauffolgend wurden die Komponenten angefertigt oder schon vorhandene modelliert. Die Anwendung der entwickelten Methode wurde unter realen Bedingungen einer Ganganalyse erfolgreich untersucht. Hierbei konnten exemplarisch die durchschnittlichen Bodenreaktionskräfte in z-Richtung für die Untergründe Kunstrasen, Kunststoffbahn (Tartanboden) und Steinboden untersucht werden. Das größte Optimierungspotential bei diesem Funktionstest zeigte sich bei der Anpassung der geeigneten An- und Ablaufstrecken mit den jeweiligen Untergründen.
Mit dieser entwickelten Methode können in einem Biomechaniklabor besser die Bedingungen die alltäglich benötigten Ganganpassungen an verschiedene Untergründe simuliert werden. In Kombination mit weiteren Messmethoden, wie die Messung der Muskelaktivität (EMG) und der Gangkinematik, kann so ein tieferes Verständnis des menschlichen Gangbildes gewonnen werden.