Refine
Year of publication
Document Type
- Article (reviewed) (108)
- Conference Proceeding (59)
- Article (unreviewed) (21)
- Report (19)
- Part of a Book (11)
- Contribution to a Periodical (7)
- Book (6)
- Doctoral Thesis (4)
- Patent (4)
Conference Type
- Konferenzartikel (48)
- Konferenz-Abstract (10)
- Konferenz-Poster (1)
Is part of the Bibliography
- yes (239) (remove)
Keywords
- Lithiumbatterie (10)
- Energieversorgung (9)
- Haustechnik (9)
- Brennstoffzelle (7)
- Wärmepumpe (6)
- Batterie (5)
- Fotovoltaik (5)
- lithium-ion battery (5)
- Bauteil (4)
- Elektrochemie (4)
Institute
- INES - Institut für nachhaltige Energiesysteme (239) (remove)
Open Access
- Open Access (112)
- Closed Access (64)
- Closed (21)
- Bronze (15)
- Diamond (13)
- Gold (13)
- Grün (6)
- Hybrid (3)
This paper provides a comprehensive overview of approaches to the determination of isocontours and isosurfaces from given data sets. Different algorithms are reported in the literature for this purpose, which originate from various application areas, such as computer graphics or medical imaging procedures. In all these applications, the challenge is to extract surfaces with a specific isovalue from a given characteristic, so called isosurfaces. These different application areas have given rise to solution approaches that all solve the problem of isocontouring in their own way. Based on the literature, the following four dominant methods can be identified: the marching cubes algorithms, the tessellation-based algorithms, the surface nets algorithms and the ray tracing algorithms. With regard to their application, it can be seen that the methods are mainly used in the fields of medical imaging, computer graphics and the visualization of simulation results. In our work, we provide a broad and compact overview of the common methods that are currently used in terms of isocontouring with respect to certain criteria and their individual limitations. In this context, we discuss the individual methods and identify possible future research directions in the field of isocontouring.
With the increasing share of renewable energies and the nuclear phase-out, the energy transition is accelerating. From the perspective of building technology, there is great potential to support this transition given its large share in total energy consumption and the increasing number of flexible and controllable components and storages. However, a question often asked at the plant level is: "How do we use this flexibility to support the regional grid?". In this work, a grid-supportive controller of a real-world building energy plant was developed using mathematical optimisation methods and its technical feasibility was demonstrated. The results could convince actors from the energy industry and academia about the practicality of these methods and offer tools for their implementation.
Lithium-ion batteries exhibit slow voltage dynamics on the minute time scale that are usually associated with transport processes. We present a novel modelling approach toward these dynamics by combining physical and data-driven models into a Grey-box model. We use neural networks, in particular neural ordinary differential equations. The physical structure of the Grey-box model is borrowed from the Fickian diffusion law, where the transport domain is discretized using finite volumes. Within this physical structure, unknown parameters (diffusion coefficient, diffusion length, discretization) and dependencies (state of charge, lithium concentration) are replaced by neural networks and learnable parameters. We perform model-to-model comparisons, using as training data (a) a Fickian diffusion process, (b) a Warburg element, and (c) a resistor-capacitor circuit. Voltage dynamics during constant-current operation and pulse tests as well as electrochemical impedance spectra are simulated. The slow dynamics of all three physical models in the order of ten to 30 min are well captured by the Grey-box model, demonstrating the flexibility of the present approach.
Given the looming threats of climate change and the rapid worldwide urbanization, it is a necessity to prioritize the transition towards a carbon-free built environment. This research study provides a holistic digital methodology for parametric design of urban residential buildings with regard to the Mediterranean semi-arid climate zone of Morocco in the early design phase. The morphological parameters of the urban residential buildings, namely the buildings’ typology, the distance between buildings, the urban grid’s orientation, and the window-towall ratio, are evaluated in order to identify the key combinations of passive and active solar design strategies that determine the high energy performing configurations, based on the introduced Energy Performance Index (EPI), which is the ratio between solar BIPV production to maximum available installed BIPV capacity and the normalized thermal energy needs. Through an automated processing of 2187 iterations via Grasshopper, we simulate daylight autonomy, indoor thermal comfort and solar rooftop photovoltaic and building integrated photovoltaic (BIPV) energy potential. Then, we analyze the conflicting objectives of energy efficiency measures, active solar design strategies, and indoor visual comfort in the decision-making process that supports our goal of getting closer to net zero urban residential buildings. The digital workflow showed interesting trends in reaching a balanced equilibrium between performance metrics influenced by the contrasting impact of solar exposure on indoor daylight autonomy and thermal energy demand. Furthermore, the study’s findings indicate that it is possible to achieve an annual load match exceeding 66,56 % while simultaneously ensuring an acceptable visual indoor comfort (sDA higher than 0.4). The findings also highlight the important role of the BIPV system in shifting towards the net zero energy goal, by contributing up to 30 % of the overall solar energy output and covering up to 20 % of the yearly self-consumption. Moreover, the energy balance evaluation on an hourly basis indicates that BIPV system notably enhances the daily load cover factor by up to 5.5 %, particularly in the case of slab SN typology, throughout the different seasons. Graphical representations of the yearly, monthly and hourly load matches and the hourly energy balance of the best performing configurations provide a thorough understanding of the potential evolution of the urban energy system over time as a result of the gradual integration of active solar electricity production.
This paper presents the use of model predictive control (MPC) based approach for peak shaving application of a battery in a Photovoltaic (PV) battery system connected to a rural low voltage gird. The goals of the MPC are to shave the peaks in the PV feed-in and the grid power consumption and at the same time maximize the use of the battery. The benefit to the prosumer is from the maximum use of the self-produced electricity. The benefit to the grid is from the reduced peaks in the PV feed-in and the grid power consumption. This would allow an increase in the PV hosting and the load hosting capacity of the grid.
The paper presents the mathematical formulation of the optimal control problem
along with the cost benefit analysis. The MPC implementation scheme in the
laboratory and experiment results have also been presented. The results show
that the MPC is able to track the deviation in the weather forecast and operate
the battery by solving the optimal control problem to handle this deviation.
The durability of polymer electrolyte membrane fuel cells (PEMFC) is governed by a nonlinear coupling between system demand, component behavior, and physicochemical degradation mechanisms, occurring on timescales from the sub-second to the thousand-hour. We present a simulation methodology for assessing performance and durability of a PEMFC under automotive driving cycles. The simulation framework consists of (a) a fuel cell car model converting velocity to cell power demand, (b) a 2D multiphysics cell model, (c) a flexible degradation library template that can accommodate physically-based component-wise degradation mechanisms, and (d) a time-upscaling methodology for extrapolating degradation during a representative load cycle to multiple cycles. The computational framework describes three different time scales, (1) sub-second timescale of electrochemistry, (2) minute-timescale of driving cycles, and (3) thousand-hour-timescale of cell ageing. We demonstrate an exemplary PEMFC durability analysis due to membrane degradation under a highly transient loading of the New European Driving Cycle (NEDC).
Nowadays decarbonisation of the energy system is one of the main concerns for most governments. Renewable energy technologies, such as rooftop photovoltaic systems and home battery storage systems, are changing the energy system to be more decentralised. As a consequence, new ways of energy business models are emerging, e.g., peer-to-peer energy trading. This new concept provides an online marketplace where direct energy exchange can occur between its participants. The purpose of this study is to conduct a content analysis of the existing literature, ongoing research projects, and companies related to peer-to-peer energy trading. From this review, a summary of the most important aspects and journal papers is assessed, discussed, and classified. It was found that the different energy market types were named in various ways and a proposal for standard language for the several peer-to-peer market types and the different actors involved is suggested. Additionally, by grouping the most important attributes from peer-to-peer energy trading projects, an assessment of the entry barrier and scalability potential is performed by using a characterisation matrix.
The DMFC is a promising option for backup power systems and for the power supply of portable devices. However, from the modeling point of view liquid-feed DMFC are challenging systems due to the complex electrochemistry, the inherent two-phase transport and the effect of methanol crossover. In this paper we present a physical 1D cell model to describe the relevant processes for DMFC performance ranging from electrochemistry on the surface of the catalyst up to transport on the cell level. A two-phase flow model is implemented describing the transport in gas diffusion layer and catalyst layer at the anode side. Electrochemistry is described by elementary steps for the reactions occurring at anode and cathode, including adsorbed intermediate species on the platinum and ruthenium surfaces. Furthermore, a detailed membrane model including methanol crossover is employed. The model is validated using polarization curves, methanol crossover measurements and impedance spectra. It permits to analyze both steady-state and transient behavior with a high level of predictive capabilities. Steady-state simulations are used to investigate the open circuit voltage as well as the overpotentials of anode, cathode and electrolyte. Finally, the transient behavior after current interruption is studied in detail.
In dieser Arbeit werden die außentemperaturgeführte Vorlauftemperaturregelung (Standard-TABS-Strategie), ein Verfahren das auf einer multiplen linearen Regression basiert (AMLR-Strategie) und ein Verfahren, das unter dem Obergriff der modellprädiktiven Regelung (MPC-Strategie) zusammengefasst werden kann, untersucht. Anhand der Simulationsergebnisse und des Integrationsaufwandes in die Gebäudeautomation des Seminargebäudes wurde eine Fokussierung auf die AMLR-Strategie vorgenommen.
Most recently, the federal government in Germany published new climate goals in order reach climate neutrality by 2045. This paper demonstrates a path to a cost optimal energy supply system for the German power grid until the year 2050. With special regard to regionality, the system is based on yearly myopic optimization with the required energy system transformation measures and the associated system costs. The results point out, that energy storage systems (ESS) are fundamental for renewables integration in order to have a feasible energy transition. Moreover, the investment in storage technologies increased the usage of the solar and wind technologies. Solar energy investments were highly accompanied with the installation of short-term battery storage. Longer-term storage technologies, such as H2, were accompanied with high installations of wind technologies. The results pointed out that hydrogen investments are expected to overrule short-term batteries if their cost continues to decrease sharply. Moreover, with a strong presence of ESS in the energy system, biomass energy is expected to be completely ruled out from the energy mix. With the current emission reduction strategy and without a strong presence of large scale ESS into the system, it is unlikely that the Paris agreement 2° C target by 2050 will be achieved, let alone the 1.5° C.
Active participation of industrial enterprises in electricity markets - a generic modeling approach
(2021)
Industrial enterprises represent a significant portion of electricity consumers with the potential of providing demand-side energy flexibility from their production processes and on-site energy assets. Methods are needed for the active and profitable participation of such enterprises in the electricity markets especially with variable prices, where the energy flexibility available in their manufacturing, utility and energy systems can be assessed and quantified. This paper presents a generic model library equipped with optimal control for energy flexibility purposes. The components in the model library represent the different technical units of an industrial enterprise on material, media, and energy flow levels with their process constraints. The paper also presents a case study simulation of a steel-powder manufacturing plant using the model library. Its energy flexibility was assessed when the plant procured its electrical energy at fixed and variable electricity prices. In the simulated case study, flexibility use at dynamic prices resulted in a 6% cost reduction compared to a fixed-price scenario, with battery storage and the manufacturing system making the largest contributions to flexibility.
There is a growing trend for the use of thermo-active building systems (TABS) for the heating and cooling of buildings, because these systems are known to be very economical and efficient. However, their control is complicated due to the large thermal inertia, and their parameterization is time-consuming. With conventional TABS-control strategies, the required thermal comfort in buildings can often not be maintained, particularly if the internal heat sources are suddenly changed. This paper shows measurement results and evaluations of the operation of a novel adaptive and predictive calculation method, based on a multiple linear regression (AMLR) for the control of TABS. The measurement results are compared with the standard TABS strategy. The results show that the electrical pump energy could be reduced by more than 86%. Including the weather adjustment, it could be demonstrated that thermal energy savings of over 41% could be reached. In addition, the thermal comfort could be improved due to the possibility to specify mean room set-point temperatures. With the AMLR, comfort category I of the comfort norms ISO 7730 and DIN EN 15251 are observed in about 95% of occasions. With the standard TABS strategy, only about 24% are within category I.
Adaptive predictive control of thermo-active building systems (TABS) based on a multiple regression algorithm: First practical test. Available from: https://www.researchgate.net/publication/305903009_Adaptive_predictive_control_of_thermo-active_building_systems_TABS_based_on_a_multiple_regression_algorithm_First_practical_test [accessed Jul 7, 2017].
The significant market growth of stationary electrical energy storage systems both for private and commercial applications has raised the question of battery lifetime under practical operation conditions. Here, we present a study of two 8 kWh lithium-ion battery (LIB) systems, each equipped with 14 lithium iron phosphate/graphite (LFP) single cells in different cell configurations. One system was based on a standard configuration with cells connected in series, including a cell-balancing system and a 48 V inverter. The other system featured a novel configuration of two stacks with a parallel connection of seven cells each, no cell-balancing system, and a 4 V inverter. The two systems were operated as part of a microgrid both in continuous cycling mode between 30% and 100% state of charge, and in solar-storage mode with day–night cycling. The aging characteristics in terms of capacity loss and internal resistance change in the cells were determined by disassembling the systems for regular checkups and characterizing the individual cells under well-defined laboratory conditions. As a main result, the two systems showed cell-averaged capacity losses of 18.6% and 21.4% for the serial and parallel configurations, respectively, after 2.5 years of operation with 810 (serial operation) and 881 (parallel operation) cumulated equivalent full cycles. This is significantly higher than the aging of a reference single cell cycled under laboratory conditions at 20 °C, which showed a capacity loss of only 10% after 1000 continuous full cycles.
Am 1. Juli 2022 trafen sich im Rahmen des Abschlusskolloquiums des Projekts ACA-Modes rund 60 Teilnehmende aus Forschung, Lehre und Industrie zu einer internationalen Konferenz an der Hochschule Offenburg. Hier wurden die Projektergebnisse rund um die erfolgreiche Implementierung modellprädiktiver Regelstrategien vorgestellt, aktuelle Fragestellungen diskutiert und Entwicklungspfade hin zu einem netzdienlichen Betrieb von Energieverbundsystemen skizziert.
n this work a mathematical model for describing the performance of lithium-ion battery electrodes consisting of porous active material particles is presented. The model represents an extension of the Newman-type model, accounting for the agglomerate structure of the active material particles, here Li(Ni1/3Co1/3Mn1/3)O2 (NCM) and Li(Ni1/3Co1/3Al1/3)O2 (NCA). To this goal, an additional pore space is introduced on the active material level. The space is filled with electrolyte and a charge-transfer reaction takes place at the liquid-solid interface within the porous active material particles. Volume-averaging techniques are used to derive the model equations. A local Thiele modulus is defined and provides an insight into the potentially limiting factors on the active material level. The introduction of a liquid-phase ion transport within the active material reduces the overall transport losses, while the additional active surface area within the agglomerate lowers the charge-transfer resistance. As a consequence, calculated discharge capacities are higher for particles modeled as agglomerates. This finding is more pronounced in the case of high C-rates
A coordinated operation of decentralised micro-scale hybrid energy systems within a locally managed network such as a district or neighbourhood will play a significant role in the sector-coupled energy grid of the future. A quantitative analysis of the effects of the primary energy factors, energy conversion efficiencies, load profiles, and control strategies on their energy-economic balance can aid in identifying important trends concerning their deployment within such a network. In this contribution, an analysis of the operational data from five energy laboratories in the trinational Upper-Rhine region is evaluated and a comparison to a conventional reference system is presented. Ten exemplary data-sets representing typical operation conditions for the laboratories in different seasons and the latest information on their national energy strategies are used to evaluate the primary energy consumption, CO2 emissions, and demand-related costs. Various conclusions on the ecologic and economic feasibility of hybrid building energy systems are drawn to provide a toe-hold to the engineering community in their planning and development.
Photovoltaic-heat pump (PV-HP) combinations with battery and energy management systems are becoming increasingly popular due to their ability to increase the autarchy and utilization of self-generated PV electricity. This trend is driven by the ongoing electrification of the heating sector and the growing disparity between growing electricity costs and reducing feed-in tariffs in Germany. Smart control strategies can be employed to control and optimize the heat pump operation to achieve higher self-consumption of PV electricity. This work presents the evaluation results of a smart-grid ready controlled PV-HP-battery system in a single-family household in Germany, using 1-minute-high-resolution field measurement data. Within 12 months evaluation period, a self-consumption of 43% was determined. The solar fraction of the HP amounts to 36%, enabled also due to higher set temperatures for space heating and domestic hot water production. Accordingly, the SPF decreases by 4.0% the space heating and by 5.7% in the domestic hot water mode. The combined seasonal performance factor for the heat pump system increases from 4.2 to 6.7, when only considering the electricity taken from the grid and disregarding the locally generated electricity supplied from photovoltaic and battery units.
Solar energy plays a central role in the energy transition. Clouds generate locally large fluctuations in the generation output of photovoltaic systems, which is a major problem for energy systems such as microgrids, among others. For an optimal design of a power system, this work analyzed the variability using a spatially distributed sensor network at Stuttgart Airport. It has been shown that the spatial distribution partially reduces the variability of solar radiation. A tool was also developed to estimate the output power of photovoltaic systems using irradiation time series and assumptions about the photovoltaic sites. For days with high fluctuations of the estimated photovoltaic power, different energy system scenarios were investigated. It was found the approach can be used to have a more realistic representation of aggregated PV power taking spatial smoothing into account and that the resulting PV power generation profiles provide a good basis for energy system design considerations like battery sizing.
In der Planungs- und Betriebspraxis herrscht im Bereich der Betriebsführung von thermisch aktivierten Bauteilsystemen und insbesondere der thermisch trägen Bauteilaktivierung noch große Unsicherheit. Trotz einer weiten Verbreitung dieser Systeme im Neubau von Nichtwohngebäuden hat sich bis heute keine einheitliche Betriebsführungsstrategie durchgesetzt. Vielmehr kritisieren Bauherren und Nutzer regelmäßig zu hohe bzw. niedrige Raumtemperaturen in den Übergangsjahreszeiten und bei Wetterwechsel sowie generell eine mangelhafte Regelbarkeit. Demgegenüber weisen Monitoringprojekte immer wieder einen hohen thermischen Komfort in diesen Gebäuden nach. Offensichtlich unterscheiden sich hier subjektiv empfundene Behaglichkeit und objektiv gemessener Komfort. Gleichzeitig sind Heiz- und Kühlkonzepte mit Flächentemperierung dann besonders energieeffizient, wenn das Regelkonzept auf deren thermische Trägheit angepasst ist. Eine gute Regelung gewährleistet also einen hohen thermischen Komfort und sorgt für einen möglichst niedrigen Energieeinsatz. Das Rechenverfahren mit Anlagenaufwandszahlen (in Anlehnung an DIN V 18599) bietet eine gute Möglichkeit, Anlagenkonzepte inklusive deren Betriebsführungsstrategie zu bewerten. Damit ist es möglich, eine auf das Gebäude angepasste Betriebsführungsstrategie für die Bauteilaktivierung zu finden und einheitlich zu bewerten.
Cooling towers or recoolers are one of the major consumers of electricity in a HVAC plant. The implementation and analysis of advanced control methods in a practical application and its comparison with conventional controllers is necessary to establish a framework for their feasibility especially in the field of decentralised energy systems. A standard industrial controller, a PID and a model based controller were developed and tested in an experimental set-up using market-ready components. The characteristics of these controllers such as settling time, control difference, and frequency of control actions are compared based on the monitoring data. Modern controllers demonstrated clear advantages in terms of energy savings and higher accuracy and a model based controller was easier to set-up than a PID.
Energy consumption for cooling is growing dramatically. In the last years, electricity peak consumption grew significantly, switching from winter to summer in many EU countries. This is endangering the stability of electricity grids. This article outlines a comprehensive analysis of an office building performances in terms of energy consumption and thermal comfort (in accordance with static – ISO 7730:2005 – and adaptive thermal comfort criteria – EN 15251:2007 –) related to different cooling concepts in six different European climate zones. The work is based on a series of dynamic simulations carried out in the Trnsys 17 environment for a typical office building. The simulation study was accomplished for five cooling technologies: natural ventilation (NV), mechanical night ventilation (MV), fan-coils (FC), suspended ceiling panels (SCP), and concrete core conditioning (CCC) applied in Stockholm, Hamburg, Stuttgart, Milan, Rome, and Palermo. Under this premise, the authors propose a methodology for the evaluation of the cooling concepts taking into account both, thermal comfort and energy consumption.
To improve the building’s energy efficiency many parameters should be assessed considering the building envelope, energy loads, occupation, and HVAC systems. Fenestration is among the most important variables impacting residential building indoor temperatures. So, it is crucial to use the most optimal energy-efficient window glazing in buildings to reduce energy consumption and at the same time provide visual daylight comfort and thermal comfort. Many studies have focused on the improvement of building energy efficiency focusing on the building envelope or the heating, ventilation, and cooling systems. But just a few studies have focused on studying the effect of glazing on building energy consumption. Thus, this paper aims to study the influence of different glazing types on the building’s heating and cooling energy consumption. A real case study building located under a semi-arid climate was used. The building energy model has been conducted using the OpenStudio simulation engine. Building indoor temperature was calibrated using ASHRAE’s statistical indices. Then a comparative analysis was conducted using seven different types of windows including single, double, and triple glazing filled with air and argon. Tripleglazed and double-glazed windows with argon space offer 37% and 32% of annual energy savings. It should be stressed that the methodology developed in this paper could be useful for further studies to improve building energy efficiency using optimal window glazing.
Nickel cobalt aluminum oxide (NCA) based lithium-ion battery electrodes exhibit a distinct asymmetry in discharge/charge behavior towards high bulk stoichiometry (low state of charge). We show that basic electrochemical relationships, that is, the Nernst equation and the Butler-Volmer equation, are able to reproduce this behavior when a two-step reaction mechanism is assumed. The two-step mechanism consists of (1) lithium-ion adsorption from the electrolyte onto the active material particle surface under electron transfer, and (2) intercalation of surface-adsorbed lithium atoms into the bulk material. The asymmetry of experimental half-cell data of an NCA electrode cycled at 0.1 C-rate can be quantitatively reproduced with this simple model. The model parameters show two alternative solutions, predicting either a saturated (highly-covered) or a depleted surface for high bulk lithiation.
Auswirkung eines Importstopps russischer Energieträger auf die Klimaschutzziele in Deutschland
(2022)
Ein Importstopp russischer Energieträger nach Deutschland wird derzeit vermehrt diskutiert. Wir wollen die Diskussion unterstützen, indem wir einen Weg zeigen, wie das Elektrizitätssystem in Deutschland kurzfristig mit geringen Energieimporten auskommt und welche Maßnahmen notwendig sind, um die Klimaschutzziele trotzdem einzuhalten. Die Ergebnisse eines solchen Energiewendeszenarios mit reduzierter Importabhängigkeit werden mit dem Energiesystemmodell MyPyPSA-Ger berechnet. Die wichtigsten Erkenntnisse sind, dass ein zügiger Ausbau Erneuerbarer Energien und von Speichertechnologien • die Abhängigkeit des deutschen Elektrizitätssystems von Energieimporten deutlich reduziert. • auch langfristig keine wesentlichen Importe der Energieträger Erdgas, Steinkohle und Mineralöl nach sich zieht. • über die Klimaziele der Bundesregierung hinaus das 1,5-Grad-Ziel im Elektrizitätssystem erreicht wird.
Ziel des Pilotprojektes EnMa-HAW ist die Erarbeitung und Erprobung technisch und organisatorisch übertragbarer Konzepte für ein automationsgestütztes Energiemanagement an allen Hochschulen für angewandte Wissenschaften im Land Baden-Württemberg. Das Energiemanagement wird technisch mittels Messtechnik, Datenerfassung, Datenspeicherung und Visualisierung umgesetzt und organisatorisch mit einem Energiezirkel in den Hochschulen verankert.
Bauteilaktivierung
(2015)
Buildings that are cooled and, if applicable, heated by thermo-active building systems (TABS) in combination with environmental energy have been established in the market during the last years. Many successful and efficient examples prove, that these systems can achieve a good thermal room comfort with a high energy efficiency of the plant system using environmental energy (mainly surface-near geothermal energy). However, operating experience and a systematic evaluation of several building projects demonstrate that there is potential improvement in the design, implementation, and operation of TABS systems. The article presents operating experience and a detailed evaluation of the operation performance of several non-residential buildings with thermo-active building systems with respect to thermal comfort and energy efficiency.
The variable refrigerant flow system is one of the best heating, ventilation, and air conditioning systems (HVAC) thanks to its ability to provide thermal comfort inside buildings. But, at the same time, these systems are considered one of the most energy-consuming systems in the building sector. Thus, it is crucial to well size the system according to the building’s cooling and heating needs and the indoor temperature fluctuations. Although many researchers have studied the optimization of the building energy performance considering heating or cooling needs, using air handling units, radiant floor heating, and direct expansion valves, few studies have considered the use of multi-objective optimization using only the thermostat setpoints of VRF systems for both cooling and heating needs. Thus, the main aim of this study is to conduct a sensitivity analysis and a multi-objective optimization strategy for a residential building containing a variable refrigerant flow system, to evaluate the effect of the building performance on energy consumption and improve the building energy efficiency. The numerical model was based on the EnergyPlus, jEPlus, and jEPlus+EA simulation engines. The approach used in this paper has allowed us to reach significant quantitative energy saving by varying the cooling and heating setpoints and scheduling scenarios. It should be stressed that this approach could be applied to several HVAC systems to reduce energy-building consumption.
There is a strong interaction between the urban atmospheric canopy layer and the building energy balance. The urban atmospheric conditions affect the heat transfer through exterior walls, the long-wave heat transfer between the building surfaces and the surroundings, the short-wave solar heat gains, and the heat transport by ventilation. Considering also the internal heat gains and the heat capacity of the building structure, the energy demand for heating and cooling and the indoor thermal environment can be calculated based on the urban microclimatic conditions. According to the building energy concept, the energy demand results in an (anthropogenic) waste heat; this is directly transferred to the urban environment. Furthermore, the indoor temperature is re-coupled via the building envelope to the urban environment and affects indirectly the urban microclimate with a temporally lagged and damped temperature fluctuation. We developed a holistic building model for the combined calculation of indoor climate and energy demand based on an analytic solution of Fourier's equation and implemented this model into the PALM model.
Seven cell design concepts for aqueous (alkaline) lithium–oxygen batteries are investigated using a multi-physics continuum model for predicting cell behavior and performance in terms of the specific energy and specific power. Two different silver-based cathode designs (a gas diffusion electrode and a flooded cathode) and three different separator designs (a porous separator, a stirred separator chamber, and a redox-flow separator) are compared. Cathode and separator thicknesses are varied over a wide range (50 μm–20 mm) in order to identify optimum configurations. All designs show a considerable capacity-rate effect due to spatiotemporally inhomogeneous precipitation of solid discharge product LiOH·H2O. In addition, a cell design with flooded cathode and redox-flow separator including oxygen uptake within the external tank is suggested. For this design, the model predicts specific power up to 33 W/kg and specific energy up to 570 Wh/kg (gravimetric values of discharged cell including all cell components and catholyte except housing and piping).
Cell lifetime diagnostics and system be-havior of stationary LFP/graphite lithium-ion batteries
(2018)
In this article the high-temperature behavior of a cylindrical lithium iron phosphate/graphite lithium-ion cell is investigated numerically and experimentally by means of differential scanning calorimetry (DSC), accelerating rate calorimetry (ARC), and external short circuit test (ESC). For the simulations a multi-physics multi-scale (1D+1D+1D) model is used. Assuming a two-step electro-/thermochemical SEI formation mechanism, the model is able to qualitatively reproduce experimental data at temperatures up to approx. 200 °C. Model assumptions and parameters could be evaluated via comparison to experimental results, where the three types of experiments (DSC, ARC, ESC) show complementary sensitivities towards model parameters. The results underline that elevated-temperature experiments can be used to identify parameters of the multi-physics model, which then can be used to understand and interpret high-temperature behavior. The resulting model is able to describe nominal charge/discharge operation behavior, long-term calendaric aging behavior, and short-term high-temperature behavior during extreme events, demonstrating the descriptive and predictive capabilities of physicochemical models.
This paper shows the results of an in-depth techno-economic analysis of the public transport sector in a small to midsize city and its surrounding area. Public battery-electric and hydrogen fuel cell buses are comparatively evaluated by means of a total cost of ownership (TCO) model building on historical data and a projection of market prices. Additionally, a structural analysis of the public transport system of a specific city is performed, assessing best fitting bus lines for the use of electric or hydrogen busses, which is supported by a brief acceptance evaluation of the local citizens. The TCO results for electric buses show a strong cost decrease until the year 2030, reaching 23.5% lower TCOs compared to the conventional diesel bus. The optimal electric bus charging system will be the opportunity (pantograph) charging infrastructure. However, the opportunity charging method is applicable under the assumption that several buses share the same station and there is a “hotspot” where as many as possible bus lines converge. In the case of electric buses for the year 2020, the parameter which influenced the most on the TCO was the battery cost, opposite to the year 2030 in where the bus body cost and fuel cost parameters are the ones that dominate the TCO, due to the learning rate of the batteries. For H2 buses, finding a hotspot is not crucial because they have a similar range to the diesel ones as well as a similar refueling time. H2 buses until 2030 still have 15.4% higher TCO than the diesel bus system. Considering the benefits of a hypothetical scaling-up effect of hydrogen infrastructures in the region, the hydrogen cost could drop to 5 €/kg. In this case, the overall TCO of the hydrogen solution would drop to a slightly lower TCO than the diesel solution in 2030. Therefore, hydrogen buses can be competitive in small to midsize cities, even with limited routes. For hydrogen buses, the bus body and fuel cost make up a large part of the TCO. Reducing the fuel cost will be an important aspect to reduce the total TCO of the hydrogen bus.
Simulation based studies for operational energy system analysis play a significant role in evaluation of various new age technologies and concepts in the energy grid. Various modelling approaches already exist and in this original paper, four models representing these approaches are compared in two real-world hybrid energy system scenarios. The models, namely TransiEnt, µGRiDS, and OpSim (including pandaprosumer and mosaic) are classified into component-oriented or system-oriented approaches as deduced from the literature research. The methodology section describes their differences under standard conditions and the necessary parameterization for the purpose of creating a framework facilitating a closest possible comparison. A novel methodology for scenario generation is also explained. The results help to quantify primary differences in these approaches that are also identified in literature and qualify the influence of the accuracy of the models for application in a system-wide analysis. It is shown that a simplified model may be sufficient for the system-oriented approach especially when the objective is an optimization-based control or planning. However, from a field level operational point of view, the differences in the time series signify the importance of the component-oriented approaches.
The lifetime of a battery is affected by various aging processes happening at the electrode scale and causing capacity and power fade over time. Two of the most critical mechanisms are the deposition of metallic lithium (plating) and the loss of lithium inventory to the solid electrolyte interphase (SEI). These side reactions compete with reversible lithium intercalation at the graphite anode. Here we present a comprehensive physicochemical pseudo-3D aging model for a lithium-ion battery cell, which includes electrochemical reactions for SEI formation on graphite anode, lithium plating, and SEI formation on plated lithium. The thermodynamics of the aging reactions are modeled depending on temperature and ion concentration, and the reactions kinetics are described with an Arrhenius-type rate law. The model includes also the positive feedback of plating on SEI growth, with the presence of plated lithium leading to a higher SEI formation rate compared to the values obtained in its absence at the same operating conditions. The model is thus able to describe cell aging over a wide range of temperatures and C-rates. In particular, it allows to quantify capacity loss due to cycling (here in % per year) as function of operating conditions. This allows the visualization of aging colormaps as function of both temperature and C-rate and the identification of critical operation conditions, a fundamental step for a comprehensive understanding of batteries performance and behavior. For example, the model predicts that at the harshest conditions (< –5 °C, > 3 C), aging is reduced compared to most critical conditions (around 0–5 °C) because the cell cannot be fully charged.
The energy system is changing since some years in order to achieve the climate goals from the Paris Agreement which wants to prevent an increase of the global temperature above 2 °C [1]. Decarbonisation of the energy system has become for governments a big challenge and different strategies are being stablished. Germany has set greenhouse gas reduction limits for different years and keeps track of the improvement made yearly. The expansion of renewable energy systems (RES) together with decarbonisation technologies are a key factor to accomplish this objective.
This research is done to analyse the effect of introducing biochar, a decarbonisation technology, and study how it will affect the energy system. Pyrolysis is the process from which biochar is obtained and it is modelled in an open-source energy system model. A sensibility analysis is done in order to assess the effect of changing the biomass potential and the costs for pyrolysis.
The role of pyrolysis is analysed in the form of different future scenarios for the year 2045 to evaluate the impact when the CO2 emission limit is zero. All scenarios are compared to the reference scenario, where pyrolysis is not considered.
Results show that biochar can be used to compensate the emissions from other conventional power plant and achieve an energy transition with lower costs. Furthermore, it was also found that pyrolysis can also reduce the need of flexibility. This study also shows that the biomass potential and the pyrolysis costs can strongly affect the behaviour of pyrolysis in the energy system.
Power systems are increasingly built from distributed generation units and smart consumers that are able to react to grid conditions. Managing this large number of decentralized electricity sources and flexible loads represent a very huge optimization problem. Both from the regulatory and the computational perspective, no one central coordinator can optimize this overall system. Decentralized control mechanisms can, however, distribute the optimization task through price signals or market-based mechanisms. This chapter presents the concepts that enable a decentralized control of demand and supply while enhancing overall efficiency of the electricity system. It highlights both technological and business challenges that result from the realization of these concepts, and presents the state-of-the-art in the respective domains.
The increasing number of prosumers and the accompanying greater use of decentralised energy resources (DERs) bring new opportunities and challenges for the traditional electricity systems and the electricity markets. Microgrids, virtual power plants (VPPs), peer-to-peer (P2P) trading and federated power plants (FPPs) propose different schemes for prosumer coordination and have the potential of becoming the new paradigm of electricity market and power system operation. This paper proposes a P2P trading scheme for energy communities that negotiates power flows between participating prosumers with insufficient renewable power supply and prosumers with surplus supply in such a way that the community welfare is maximized while avoiding critical grid conditions. For this purpose, the proposed scheme is based on an Optimal Power Flow (OPF) problem with a Multi-Bilateral Economic Dispatch (MBED) formulation as an objective function. The solution is realized in a fully decentralized manner on the basis of the Relaxed Consensus + Innovations (RCI) algorithm. Network security is ensured by a tariff-based system organized by a network agent that makes use of product differentiation capabilities of the RCI algorithm. It is found that the proposed mechanism accurately finds and prevents hazardous network operations, such as over-voltage in grid buses, while successfully providing economic value to prosumers’ renewable generation within the scope of a P2P, free market.
Demand Side Management for Thermally Activated Building Systems based on Multiple Linear Regression
(2015)
It is considered necessary to implement advanced controllers such as model predictive control (MPC) to utilize the technical flexibility of a building polygeneration system to support the rapidly expanding renewable electricity grid. These can handle multiple inputs and outputs, uncertainties in forecast data, and plant constraints, amongst other features. One of the main issues identified in the literature regarding deploying these controllers is the lack of experimental demonstrations using standard components and communication protocols. In this original work, the economic-MPC-based optimal scheduling of a real-world heat pump-based building energy plant is demonstrated, and its performance is evaluated against two conventional controllers. The demonstration includes the steps to integrate an optimization-based supervisory controller into a typical building automation and control system with off-the-shelf HVAC components and usage of state-of-art algorithms to solve a mixed integer quadratic problem. Technological benefits in terms of fewer constraint violations and a hardware-friendly operation with MPC were identified. Additionally, a strong dependency of the economic benefits on the type of load profile, system design and controller parameters was also identified. Future work for the quantification of these benefits, the application of machine learning algorithms, and the study of forecast deviations is also proposed.
This article presents the development, parameterization, and experimental validation of a pseudo-three-dimensional (P3D) multiphysics aging model of a 500 mAh high-energy lithium-ion pouch cell with graphite negative electrode and lithium nickel manganese cobalt oxide (NMC) positive electrode. This model includes electrochemical reactions for solid electrolyte interphase (SEI) formation at the graphite negative electrode, lithium plating, and SEI formation on plated lithium. The thermodynamics of the aging reactions are modeled depending on temperature and ion concentration and the reactions kinetics are described with an Arrhenius-type rate law. Good agreement of model predictions with galvanostatic charge/discharge measurements and electrochemical impedance spectroscopy is observed over a wide range of operating conditions. The model allows to quantify capacity loss due to cycling near beginning-of-life as function of operating conditions and the visualization of aging colormaps as function of both temperature and C-rate (0.05 to 2 C charge and discharge, −20 °C to 60 °C). The model predictions are also qualitatively verified through voltage relaxation, cell expansion and cell cycling measurements. Based on this full model, six different aging indicators for determination of the limits of fast charging are derived from post-processing simulations of a reduced, pseudo-two-dimensional isothermal model without aging mechanisms. The most successful aging indicator, compared to results from the full model, is based on combined lithium plating and SEI kinetics calculated from battery states available in the reduced model. This methodology is applicable to standard pseudo-two-dimensional models available today both commercially and as open source.
Optimisation based economic despatch of real-world complex energy systems demands reduced order and continuously differentiable component models that can represent their part-load behaviour and dynamic responses. A literature study of existing modelling methods and the necessary characteristics the models should meet for their successful application in model predictive control of a polygeneration system are presented. Deriving from that, a rational modelling procedure using engineering principles and assumptions to develop simplified component models is applied. The models are quantitatively and qualitatively evaluated against experimental data and their efficacy for application in a building automation and control architecture is established.
In this article we outline the model development planned within the joint projectModel-based city planningand application in climate change (MOSAIK). The MOSAIK project is funded by the German FederalMinistry of Education and Research (BMBF) within the frameworkUrban Climate Under Change ([UC]2)since 2016. The aim of MOSAIK is to develop a highly-efficient, modern, and high-resolution urban climatemodel that allows to be applied for building-resolving simulations of large cities such as Berlin (Germany).The new urban climate model will be based on the well-established large-eddy simulation code PALM, whichalready has numerous features related to this goal, such as an option for prescribing Cartesian obstacles. Inthis article we will outline those components that will be added or modified in the framework of MOSAIK.Moreover, we will discuss the everlasting issue of acquisition of suitable geographical information as inputdata and the underlying requirements from the model's perspective.
The humanoid Sweaty was the finalist in this year’s robocup soccer championship(adult size). For the optimization of the gait and the stability, data concerning forces and torques in the ankle joints would be helpful. In the following paper the development of a six-axis force and torque sensor for the humanoid robot Sweaty is described. Since commercial sensors do not meet the demands for the sensors in Sweatys ankle joints, a new sensor was developed. As a measuring devices we used strain gauges and custom electronics based on an acam PS09. The geometry was analyzed with the FEM program ANSYS to get optimal dimensions for the measuring beams. In addition ANSYS was used to optimize the position for the strain gauges on the beam.
Der sommerliche Wärmeschutz von Schulgebäuden im Oberrheingraben und die Bereitstellung von Kühlenergie wurden bereits untersucht und finden Aufnahme im Leitfaden „Natürliche Gebäudeklimatisierung in Klassenzimmern des südlichen Oberrheins“. Im Rahmen der Arbeiten zur Minderung der sommerlichen Überhitzung wurde durch den Einbau und die damit verbundene kontinuierliche Aufzeichnung der CO2‐Konzentrationen der Raumluft festgestellt, dass besonders im Winterhalbjahr eine Verbesserung der Luftqualität erreicht werden muss.
Peer-to-peer energy trading and local electricity markets have been widely discussed as new options for the transformation of the energy system from the traditional centralized scheme to the novel decentralized one. Moreover, it has also been proposed as a more favourable alternative for already expiring feed in tariff policies that promote investment in renewable energy sources. Peer-to-peer energy trading is usually defined as the integration of several innovative technologies, that enable both prosumers and consumers to trade electricity, without intermediaries, at a consented price. Furthermore, the techno-economic aspects go hand in hand with the socio-economic aspects, which represent at the end significant barriers that need to be tackled to reach a higher impact on current power systems. Applying a qualitative analysis, two scalable peer-to-peer concepts are presented in this study and the possible participant´s entry probability into such concepts. Results show that consumers with a preference for environmental aspects have in general a higher willingness to participate in peer-to-peer energy trading. Moreover, battery storage systems are a key technology that could elevate the entry probability of prosumers into a peer-to-peer market.
Lithium-oxygen cells with organic electrolyte suffer high overpotentials during charge, indicating asymmetric charge/discharge reaction mechanisms. We present a multi-physics dynamic modeling and simulation study of the Li/O2 cell cycling behavior. We present three different multi-step mechanisms of the 2 Li + O2 ⇄ Li2O2 cell reaction, (A) a reversible 5-step mechanism, (B) a partially irreversible 6-step mechanism, and (C) a partially irreversible 8-step mechanism that includes reactions of a redox mediator. Model predictions are compared to experimental galvanostatic cycling data of Swagelok cells without and with 2,2,6,6-tetramethylpiperidinyloxyl (TEMPO) as redox mediator. All mechanisms are able to predict the discharge behavior in good agreement to the experimental results. The experimentally observed high charge overpotentials as well as their reduction by using a redox mediator can be qualitatively reproduced with the irreversible reaction mechanisms. However, the particular shape of the experimental charge curve with continuously increasing charge overpotential cannot be reproduced with the present mechanisms.
Micronization of biochar (BC) may ease its application in agriculture. For example, fine biochar powders can be applied as suspensions via drip-irrigation systems or can be used to produce grnulated fertilizers. However, micronization may effect important physical biochar properties like the water holding capacity (WHC) or the porosity.
Since 2003, most European countries established heat health warning systems to alert the population to heat load. Heat health warning systems are based on predicted meteorological conditions outdoors. But the majority of the European population spends a substantial amount of time indoors, and indoor thermal conditions can differ substantially from outdoor conditions. The German Meteorological Service (Deutscher Wetterdienst, DWD) extended the existing heat health warning system (HHWS) with a thermal building simulation model to consider heat load indoors. In this study, the thermal building simulation model is used to simulate a standardized building representing a modern nursing home, because elderly and sick people are most sensitive to heat stress. Different types of natural ventilation were simulated. Based on current and future test reference years, changes in the future heat load indoors were analyzed. Results show differences between the various ventilation options and the possibility to minimize the thermal heat stress during summer by using an appropriate ventilation method. Nighttime ventilation for indoor thermal comfort is most important. A fully opened window at nighttime and the 2-h ventilation in the morning and evening are more sufficient to avoid heat stress than a tilted window at nighttime and the 1-h ventilation in the morning and the evening. Especially the ventilation in the morning seems to be effective to keep the heat load indoors low. Comparing the results for the current and the future test reference years, an increase of heat stress on all ventilation types can be recognized.
This article presents a comparative experimental study of the electrical, structural and chemical properties of large‐format, 180 Ah prismatic lithium iron phosphate (LFP)/graphite lithium‐ion battery cells from two different manufacturers. These cells are particularly used in the field of stationary energy storage such as home‐storage systems. The investigations include (1) cell‐to‐cell performance assessment, for which a total of 28 cells was tested from each manufacturer, (2) electrical charge/discharge characteristics at different currents and ambient temperatures, (3) internal cell geometries, components, and weight analysis after cell opening, (4) microstructural analysis of the electrodes via light microscopy and scanning electron microscopy, (5) chemical analysis of the electrode materials using energy‐dispersive X‐ray spectroscopy, and (6) mathematical analysis of the electrode balances. The combined results give a detailed and comparative insight into the cell characteristics, providing essential information needed for system integration. The study also provides complete and self‐consistent parameter sets for the use in cells models needed for performance prediction or state diagnosis.
Electrochemical impedance spectroscopy (EIS) is a widely-used diagnostic technique to characterize electrochemical processes. It is based on the dynamic analysis of two electrical observables, that is, current and voltage. Electrochemical cells with gaseous reactants or products (e.g., fuel cells, metal/air cells, electrolyzers) offer an additional observable, that is, the gas pressure. The dynamic coupling of current and/or voltage with gas pressure gives rise to a number of additional impedance definitions, for which we use the term electrochemical pressure impedance. It also gives rise to different experimental probing approaches. In this article we present a model-based study of electrochemical pressure impedance spectroscopy (EPIS). Possible quantifications and realizations of EPIS are discussed. The study of generic cell geometries consisting of gas reservoir, diffusion layer(s) and electrochemically active layer(s) reveals distinct spiral-shaped features in the Nyquist plot. Using the example of a sodium/oxygen (Na/O2) cell, the dynamic spatiotemporal behavior of the state variables is quantified and interpreted. Results are compared to first experimental EPIS measurements by Hartmann et al. [J. Phys. Chem. C118, 1461, 2014]. A sensitivity analysis highlights the properties of EPIS with respect to geometric, transport, and kinetic parameters. We demonstrate that EPIS is sensitive to transport parameters that are not well-accessible with standard EIS.
Mass transfer phenomena in membrane fuel cells are complex and diversified because of the presence of complex transport pathways including porous media of very different pore sizes and possible formation of liquid water. Electrochemical impedance spectroscopy, although allowing valuable information on ohmic phenomena, charge transfer and mass transfer phenomena, may nevertheless appear insufficient below 1 Hz. Use of another variable, that is, back pressure, as an excitation variable for electrochemical pressure impedance spectroscopy is shown here a promising tool for investigations and diagnosis of fuel cells.
Electrochemical pressure impedance spectroscopy (EPIS) has recently been developed as a potential diagnosis tool for polymer electrolyte membrane fuel cells (PEMFC). It is based on analyzing the frequency response of the cell voltage with respect to an excitation of the gas-phase pressure. We present here a combined modeling and experimental study of EPIS. A pseudo-twodimensional PEMFC model was parameterized to a 100 cm2 laboratory cell installed in its test bench, and used to reproduce steady-state cell polarization and electrochemical impedance spectra (EIS). Pressure impedance spectra were obtained both in experiment and simulation by applying a harmonic pressure excitation at the cathode outlet. The model shows good agreement with experimental data for current densities ⩽ 0.4 A cm−2. Here it allows a further simulative analysis of observed EPIS features, including the magnitude and shape of spectra. Key findings include a strong influence of the humidifier gas volume on EPIS and a substantial increase in oxygen partial pressure oscillations towards the channel outlet at the resonance frequency. At current densities ⩾ 0.8 A cm−2 the experimental EIS and EPIS data cannot be fully reproduced. This deviation might be associated with the formation and transport of liquid water, which is not included in the model.
Electrochemical pressure impedance spectroscopy (EPIS) is an emerging tool for the diagnosis of polymer electrolyte membrane fuel cells (PEMFC). It is based on analyzing the frequency response of the cell voltage with respect to an excitation of the gas-phase pressure. Several experimental studies in the past decade have shown the complexity of EPIS signals, and so far there is no agreement on the interpretation of EPIS features. The present study contributes to shed light into the physicochemical origin of EPIS features, by using a combination of pseudo-two-dimensional modeling and analytical interpretation. Using static simulations, the contributions of cathode equilibrium potential, cathode overpotential, and membrane resistance on the quasi-static EPIS response are quantified. Using model reduction, the EPIS responses of individual dynamic processes are predicted and compared to the response of the full model. We show that the EPIS signal of the PEMFC studied here is dominated by the humidifier. The signal is further analyzed by using transfer functions between various internal cell states and the outlet pressure excitation. We show that the EPIS response of the humidifier is caused by an oscillating oxygen molar fraction due to an oscillating mass flow rate.
Electrochemical pressure impedance spectroscopy (EPIS) has received the attention of researchers as a method to study mass transport processes in polymer electrolyte mem-brane fuel cells (PEMFC). It is based on analyzing the cell voltage response to a harmonic excitation of the gas phase pressure in the frequency domain. Several experiments with a single-cell fuel cell have shown that the spectra contain information in the frequency range typical for mass transport processes and are sensitive to specific operating condi-tions and structural fuel cell parameters. To further benefit from the observed features, it is essential to identify why they occur, which to date has not yet been accomplished. The aim of the present work, therefore, is to identify causal links between internal processes and the corresponding EPIS features.
To this end, the study follows a model-based approach, which allows the analysis of inter-nal states that are not experimentally accessible. The PEMFC model is a pseudo-2D model, which connects the mass transport along the gas channel with the mass transport through the membrane electrode assembly. A modeling novelty is the consideration of the gas vol-ume inside the humidifier upstream the fuel cell inlet, which proves to be crucial for the reproduction of EPIS. The PEMFC model is parametrized to a 100 cm² single cell of the French project partner, who provided the experimental EPIS results reproduced and in-terpreted in the present study.
The simulated EPIS results show a good agreement with the experiments at current den-sities ≤ 0.4 A cm–2, where they allow a further analysis of the observed features. At the lowest excitation frequency of 1 mHz, the dynamic cell voltage response approaches the static pressure-voltage response. In the simulated frequency range between 1 mHz – 100 Hz, the cell voltage oscillation is found to strongly correlate with the partial pressure oscillation of oxygen, whereas the influence of the water pressure is limited to the low frequency region.
The two prominent EPIS features, namely the strong increase of the cell voltage oscillation and the increase of phase shift with frequency, can be traced back via the oxygen pressure to the oscillation of the inlet flow rate. The phenomenon of the oscillating inlet flow rate is a consequence of the pressure change of the gas phase inside the humidifier and in-creases with frequency. This important finding enables the interpretation of experimen-tally observed EPIS trends for a variation of operational and structural fuel cell parame-ters by tracing them back to the influence of the oscillating inlet flow rate.
The separate simulation of the time-dependent processes of the PEMFC model through model reduction shows their individual influence on EPIS. The sluggish process of the wa-ter uptake by the membrane is visible below 0.1 Hz, while the charge and discharge of the double layer becomes visible above 1 Hz. The gas transport through the gas diffusion layer is only visible above 100 Hz. The simulation of the gas transport through the gas channel
without consideration of the humidifier becomes visible above 1 Hz. With consideration of the humidifier the gas transport through the gas channel is visible throughout the fre-quency range. The strong similarity of the spectra considering the humidifier with the spectra of the full model setup shows the dominant influence of the humidifier on EPIS.
A promising observation is the change in the amplitude relationship between the cell volt-age and the oxygen partial pressure oscillation as a function of the oxygen concentration in the catalyst layer. At a frequency where the influence of oxygen pressure on the cell voltage is dominant, for example at 1 Hz, the amplitude of the cell voltage oscillation could be used to indirectly measure the oxygen concentration in the catalyst layer.
The lifetime and performance of solid-oxide fuel cells (SOFC) and electrolyzer cells (SOEC) can be significantly degraded by oxidation of nickel within the electrode and support structures. This paper documents a detailed computational model describing nickel oxide (NiO) formation as a growing film layer on top of the nickel phase in Ni/YSZ composite electrodes. The model assumes that the oxidation rate is controlled by transport of ions across the film (Wagner's theory). The computational model, which is implemented in a two-dimensional continuum framework, facilitates the investigation of alternative chemical reaction and transport mechanisms. Model predictions agree well with a literature experimental measurement of oxidation-layer growth. In addition to providing insight in interpreting experimental observations, the model provides a quantitative predictive capability for improving electrode design and controlling operating conditions.
Der vorliegende Beitrag beschreibt die Motivation hinter den Forschungsarbeiten im Electric Mobility Competence Center (EMC^2) rund um elektrische Antriebskomponenten für die Elektromobilität sowie die Notwendigkeit, diese Forschungsarbeiten an Prüfständen zu testen und zu validieren. Zunächst wird näher auf die Charakteristik von elektrischen Maschinen eingegangen, um anschließend die verwendete Prüfstandtechnik vorzustellen.
Encapsulant-free N.I.C.E. modules have strong ecological advantages compared to conventional laminated modules but suffer generally from lower electrical performance. Via long-term outdoor monitoring of fullsize industrial modules of both types with identical solar cells, we investigated if the performance difference remains constant over time and which parameters influence its value. After assessing about a full year’s data, two obvious levers for N.I.C.E. optimization are identified: The usage of textured glass and transparent adhesives on the module rear side. Also, the performance loss could be alleviated using tracking systems due to lower AOI values. Our measurements show additionally that N.I.C.E. module surfaces are in average about 2.5°C cooler compared to laminated modules. With these findings, we lay out a roadmap to reduce today’s LIV gap of about 5%rel by different optimizations.
We present an electrochemical model of a lithium iron phosphate/graphite (LFP/C6) cell that includes combined aging mechanisms: (i) Electrochemical formation of the solid electrolyte interphase (SEI) at the anode, leading to loss of lithium inventory, (ii) breaking of the SEI due to volume changes of the graphite particles, causing accelerated SEI growth, and (iii) loss of active material due to of loss percolation of the liquid electrolyte resulting from electrode dry-out. The latter requires the introduction of an activity-saturation relationship. A time-upscaling methodology is developed that allows to simulate large time spans (thousands of operating hours). The combined modeling and simulation framework is able to predict calendaric and cyclic aging up to the end of life of the battery cells. The aging parameters are adjusted to match literature calendaric and cyclic aging experiments, resulting in quantitative agreement of simulated nonlinear capacity loss with experimental data. The model predicts and provides an interpretation for the dependence of capacity loss on temperature, cycling depth, and average SOC. The introduction of a percolation threshold in the activity-saturation relationship allows to capture the strong nonlinearity of aging toward end of life (“sudden death”).
A smart energy concept was designed and implemented for a cluster of 5 existing multi-family houses, which combines heat pumps, photovoltaic (PV) modules and combined heat and power units (CHP) to achieve energy- and cost-efficient operation. Measurement results of the first year of operation show that the local power generation by PV modules and CHP unit has a positive effect on the electrical self-sufficiency by reducing electricity import from the grid. In winter, when the CHP unit operates continuously for long periods, the entire electricity for the heat pump and 91 % of the total electricity demand of the neighborhood are supplied locally. In summer, only 53 % is generated within the neighborhood. The use of a specifically developed energy management system EMS is intended to further increase this share. CO2 emissions for heating and electricity of the neighborhood are evaluated and amount to 18.4 kg/(m2a). Compared to the previous energy system consisting of gas boilers (29.1 kg/(m2a)), savings of 37 % are achieved with electricity consumption from the grid being reduced by 65 %. In the second construction stage, an additional heat pump, CHP unit and PV modules will be added. The measurement results indicate that the final district energy system is likely to achieve the ambitious CO2 reduction goal of -50% and further increase the self-sufficiency of the district.
Im Rahmen des EU-Forschungsprojektes ACA-Modes (Advanced Control Algorithms for Management of Decentralised Energy Systems) werden reale Labore der Projektpartner primärenergetisch, ökonomisch und die Emissionen betreffend bewertet. Vier Projektpartner liefern Datensätze aus Messreihen typischer Bereitstellungsszenarien. Die verschiedenen Systeme bestehen unter anderem aus einer KWK-Anlage mit Erdgas-Verbrennungsmotor, einer KWKK-Anlage mit Adsorptionskältemaschine, einer Photovoltaik-Anlage mit Batteriespeicher und Wärmepumpe und einer Solarthermieanlage mit Adsorptionskältemaschine.
In 35 deutschen und 7 europäischen Büro- und Verwaltungsgebäuden wurden auf Basis von Monitoringkampagnen über mehrere Betriebsjahre Raum- und Außentemperaturwerte in zeitlich hoher Auflösung erfasst und der thermische Raumkomfort im Sommer standardisiert nach der Komfortnorm DIN EN 15251:2007-08 detailliert ausgewertet. Ergänzt wird die Auswertung um Kurzzeitmesskampagnen über zwei sehr warme Wochen im Sommer in unsanierten bzw. teilsanierten Bürogebäuden, errichtet im Zeitraum von 1960 bis 1975. Die untersuchten Gebäude mit ihrem jeweiligen Kühlkonzept lassen sich in sechs Kategorien einteilen: ohne Kühlung, passive, luftgeführte und wassergeführte Kühlung sowie Mixed-mode-Kühlung und Vollklimatisierung. Im Quervergleich aller Gebäude werden die Kühlkonzepte gleichermaßen nach dem thermischen Raumkomfort und thermischen Kühlenergiebezug bewertet. Detaillierte Komfortuntersuchungen nach der Europäischen Komfortnorm DIN EN 15251:2007-08 geben Hinweise auf die Wirksamkeit der eingesetzten Kühltechnologien in den jeweiligen Klimazonen. Daraus lassen sich Handlungsempfehlungen für die Planungspraxis und den Gebäudebetrieb ableiten.
Unter dem europäischen Programm Intelligent Energy for Europe (IEE) fanden sich acht europäische Partner zusammen, um im Rahmen des Projektes ThermCo Lüftungs‐ und Kühlenergiekonzepte für Nichtwohngebäude mit niedrigem Energieeinsatz im Hinblick auf die Energieeffizienz und den thermischen Raumkomfort zu bewerten (siehe Teil 1 dieser Veröffentlichung in Bauphysik 34 (2012), Heft 6. Mit Hilfe einer Simulationsstudie für ein typisches Bürogebäude wird das Potenzial unterschiedlicher Lüftungs‐ und Kühlstrategien unter Berücksichtigung von Energieeffizienz und Raumkomfort für verschiedene europäische Klimazonen bewertet. Die Ergebnisse weisen eine hohe Wirksamkeit von Nachtlüftungskonzepten im nord‐europäischen Sommerklima mit verhältnismäßig niedrigen Außentemperaturen nach. Im mitteleuropäischen Sommerklima bietet das Erdreich ein ausreichend niedriges Temperaturniveau für den effizienten Einsatz von wassergeführten Flächentemperiersystemen. Im südeuropäischen Sommerklima kann eine aktive Kühlung über Luft die hohen und schnell fluktuierenden Kühllasten effizient abführen.
Unter dem europäischen Programm Intelligent Energy for Europe (IEE) fanden sich acht europäische Partner zusammen, um im Rahmen des Projektes ThermCo Lüftungs‐ und Kühlenergiekonzepte für Nichtwohngebäude mit niedrigem Energieeinsatz im Hinblick auf die Energieeffizienz und den thermischen Raumkomfort zu bewerten. Die Analyse erfolgte auf Basis von detaillierten Langzeitmessungen über ein Betriebsjahr in acht Demonstrationsgebäuden in unterschiedlichen klimatischen Zonen Europas und einer standardisierten Datenauswertung. Im Quervergleich aller acht Gebäude werden die Kühlkonzepte gleichermaßen nach dem thermischen Kühlenergiebezug, dem thermischen Raumkomfort und dem Primärenergieeinsatz für die technische Gebäudeausrüstung und die Beleuchtung bewertet. Ein Energiekonzept ist erst dann zufriedenstellend, wenn mit möglichst geringem Energieeinsatz und bei hoher Anlageneffizienz ein guter thermischer Raumkomfort zur Verfügung gestellt werden kann. Mit entsprechenden Gebäudesignaturen werden diese Parameter in einen Zusammenhang gebracht und die Zielstellung überprüft. Detaillierte Komfortuntersuchungen nach der europäischen Komfortnorm DIN EN 15251:2007‐08 geben Hinweise auf die Wirksamkeit der eingesetzten Kühltechnologien in den jeweiligen Klimazonen. Daraus lassen sich Handlungsempfehlungen ableiten.
Das Projektvorhaben "Energienetzmanagement dezentraler KWK‐Anlagen mit diversen Verbraucherstrukturen", das vom Innovationsfonds der badenova AG & Co KG von Mai 2012 bis Juli 2016 unter der Fördernummer 2012‐09 gefördert wurde kann aus Sicht des Projektnehmers Hochschule Offenburg und seiner Partner Stadt Offenburg und G. und M. Zapf Energie GbR mbH als sehr erfolgreich umgesetztes Fördervorhaben bezeichnet werden. Während der ca. vier Jahre Projektlaufzeit konnten mehrere Reallabore geschaffen werden, die an die Eigenschaften eines Subnetzes in einem Smart Grid sehr nah herangeführt wurden. Alle Objekte bzw. Netzstrukturen verfügen über typische Komponenten eines Microgrids mit Energiequellen, Speichern und Senken. Auch wurde die Trigeneration als Netzvariante mit Strom‐ Wärme und Kältebereitstellung aufgegriffen und für Verteilnetzmodelle der Niederspannungsebene beschrieben. Ausgehend von einem Mikronetzmodell für jede Energieart kann hinter jeder Trafostation eine beliebig komplexe Energieversorgungsstruktur aufgespannt werden.
Energietechnik
(2013)
Dieses Lehrbuch vermittelt dem Leser ein grundlegendes, dennoch kurz gefasstes Verständnis für die Zusammenhänge der Energieumwandlungsprozesse. Es umfasst die gesamte Bandbreite der Energietechnik. Die Schwerpunkte reichen von der kompletten Beschreibung der nachhaltigen, erneuerbaren Energietechniken, über Gas- und Dampfturbinen-Kraftwerke sowie Kraft-Wärme-Kälte-Kopplungsanlagen bis hin zur Energieverteilung und zum Kyoto-Protokoll. In der vorliegenden sechsten Auflage wurden im Kapitel Kerntechnik die Erfahrungen aus dem Fukushima-Unglück dokumentiert und die Kapitel Energieverteilung und Energiespeicherung neu gefasst, um den Tendenzen der politisch festgelegten deutschen Energiewende Rechnung zu tragen.
Energy efficiency and hygrothermal performance of hemp clay walls for Moroccan residential buildings
(2023)
Hemp-based building envelopes have gained significant popularity in developed countries, and now the trend of constructing houses with hemp-clay blocks is spreading to developing countries like Morocco. Investigating the hygrothermal behavior of such structures under actual climate conditions is essential for advancing and promoting this sustainable practice. This paper presents an in-depth experimental characterization of a commercial hemp-clay brick that has been exposed to the outdoor environment for four years, in addition to field measurements on a building scale demonstration prototype. Additionally, the study simulates 17 representative cities to assess the hygrothermal performance and energy-saving potential in each of Morocco's six existing climate zones, using the EnergyPlus engine. The experimental campaign's findings demonstrate excellent indoor air temperature and relative humidity regulation within the hemp-clay wall building, leading to satisfactory levels of thermal comfort within hemp-clay wall buildings. This is attributed to the material's good thermal conductivity and excellent moisture buffering capacity (found to be 0.31 W/mK and 2.25 g/m2%RH), respectively). The energy simulation findings also point to significant energy savings, with cooling and heating energy reductions ranging from 27.7% to 47.5% and 33.7% to 79.8%, respectively, as compared to traditional Moroccan buildings.
In this paper we report on further success of our work to develop a multi-method energy optimization which works with a digital twin concept. The twin concept serves to replicate production processes of different kinds of production companies, including complex energy systems and test market interactions to then use them for model predictive optimizing. The presented work finally reports about the performed flexibility assessment leading to a flexibility audit with a list of measures and the impact of energy optimizations made related to interactions with the local power grid i.e., the exchange node of the low voltage distribution grid. The analysis and continuous exploration of flexibilities as well as the exchange with energy markets require a “guide” leading to continuous optimization with a further tool like the Flexibility Survey and Control Panel helping decision-making processes on the day-ahead horizon for real production plants or the investment planning to improve machinery, staff schedules and production
infrastructure.
The current methods used to assess the energy performance of ventilation devices do not consider all the aspects necessary for a comprehensive evaluation of decentralised ventilation concepts and can only be partially adapted to their needs. In order to improve the energy evaluation and to ensure the comparability of different systems, a calorimetric method was developed and implemented in test facilities for the evaluation of two decentralised devices: one equipped with a recuperative counter flow heat exchanger and one with a regenerative heat exchanger. This method, based on direct measurements of the heating load in an insulated test room, includes the effect of the electrical consumption of the fans on the energy performance of the ventilation devices. The calorimetric evaluation method was extended to a seasonal evaluation on the basis of a heating-degree-day method implemented for a warm, a cool and a moderate location in Europe: Athens, Strasbourg and Copenhagen. All the results are above 50% efficiency for both devices, even in Athens where the use of heat recovery ventilation is not usual.
Passive solar elements for both direct and indirect gains, are systems used to maintain a comfortable living environment while saving energy, especially in the building energy retrofit and adaptation process. Sunspaces, thermal mass and glazing area and orientation have been often used in the past to guarantee adequate indoor conditions when mechanical devices were not available. After a period of neglect, nowadays they are again considered as appropriate systems to help face environmental issues in the building sector, and both international and national legislation takes into consideration the possibility of including them in the building planning tools, also providing economic incentives. Their proper design needs dynamic simulation, often difficult to perform and time consuming. Moreover, results generally suffer from several uncertainties, so quasi steady-state procedures are often used in everyday practice with good results, but some corrections are still needed. In this paper, a comparative analysis of different solutions for the construction of verandas in an existing building is presented, following the procedure provided by the slightly modified and improved Standard EN ISO 13790:2008. Advantages and disadvantages of different configurations considering thermal insulation, windows typology and mechanical ventilation systems are discussed and a general intervention strategy is proposed. The aim is to highlight the possibility of using sunspaces in order to increase the efficiency of the existing building stock, considering ease of construction and economic viability.
Energy Performance of Verandas in the Building Retrofit Process (PDF Download Available). Available from: https://www.researchgate.net/publication/303093420_Energy_Performance_of_Verandas_in_the_Building_Retrofit_Process [accessed Jul 5, 2017].
Ziel der Investitionsmaßnahme Enerlab 4.0 war die Bereitstellung einer umfangreichen in-operando und post-mortem Diagnostik für dezentrale Energieerzeuger und -Speicher, z. B. Batteriezellen und Photovoltaikzellen. Diese sind wichtige Komponenten für verschiedene Bereiche der Industrie 4.0 – von autonomen Sensoren über energieautarke Produktion bis hin zur Qualitätskontrolle. Zu diesem Zweck wurde die apparative Ausstattung der Hochschule Offenburg erweitert, und zwar sowohl für in-operando Diagnostik (elektrische Zyklierer, Impedanzspektrometer, Temperaturprüfschränke) als auch für post-mortem Diagnostik (Glovebox, Probenpräparationen für vorhandene Werkstoffanalytik und chemische Analytik). Be-reits vorhandene Geräte aus anderen laufenden oder abgeschlossenen Projekten wurden in die neue Infrastruktur integriert. Im Ergebnis entstand ein modernes und leistungsfähiges Batterie- und Photovoltaiklabor, welches in zahlreichen laufenden und neuen Vorhaben genutzt wird.
Soiling is an important issue in the renewable energy sector since it can result in significant yield losses, especially in regions with higher pollution or dust levels. To mitigate the impact of soiling on photovoltaic (PV) plants, it is essential to regularly monitor and clean the panels, as well as develop accurate soiling predictions that can affect cleaning strategies and enhance the overall performance of PV power plants. This research focuses on the problem of soiling loss in photovoltaic power plants and the potential to improve the accuracy of soiling predictions. The study examines how soiling can affect the efficiency and productivity of the modules and how to measure and predict soiling using machine learning (ML) algorithms. The research includes analyzing real data from large-scale ground-mounted PV sites and comparing different soiling measurement methods. It was observed that there were some deviations in the real soiling loss values compared to the expected values for some projects in southern Spain, thus, the main goal of this work is to develop machine learning models that could predict the soiling more accurately. The developed models have a low mean square error (MSE), indicating the accuracy and suitability of the models to predict the soiling rates. The study also investigates the impact of different cleaning strategies on the performance of PV power plants and provides a powerful application to predict both the soiling and the number of cleaning cycles.
Autonomous humanoid robots need high torque actuators to be able to walk and run. One problem in this context is the heat generated. In this paper we propose to use water evaporation to improve cooling of the motors. Simulations based on thermodynamic calculations as well as measurements on real actuators show that, under the assumption of the load of a soccer game, cooling can be considerably improved with relatively small amounts of water.
This paper presents a framework for numerical building validation enhancement based on detailed building specifications from in-situ measurements and evidence-based validation assessment undertaken on a detached sustainable lightweight building in a semi-arid climate. The validation process has been undergone in a set of controlled experiments – a free-float period, and steady-state internal temperatures. The validation was conducted for a complete year with a 1-min time step for the hourly indoor temperature and the variable refrigerant flow (VRF) energy consumption. The initial baseline model was improved by three series of validation steps per three different field measurements including thermal transmittance, glazing thermal and optical properties, and airtightness. Then, the accurate and validated model was used for building energy efficiency assessment in 12 regions of Morocco. This study aims to assess the effect of accurate building characteristics values on the numerical model enhancement. The initial CV(RMSE) and NMBE have improved respectively from 14.58 % and −11.23 %–7.85 % and 1.86 % for the indoor temperature. Besides, from 31.17 % to 14.37 %–20.57 % and 9.77 % for energy consumption. The findings demonstrate that the lightweight construction with the use of a variable refrigerant flow system could be energy efficient in the southern regions of Morocco.
The transformation of the building energy sector to a highly efficient, clean, decentralised and intelligent system requires innovative technologies like microscale trigeneration and thermally activated building structures (TABS) to pave the way ahead. The combination of such technologies however presents a scientific and engineering challenge. Scientific challenge in terms of developing optimal thermo-electric load management strategies based on overall energy system analysis and an engineering challenge in terms of implementing these strategies through process planning and control. Initial literature research has pointed out the need for a multiperspective analysis in a real life laboratory environment. To this effect an investigation is proposed wherein an analytical model of a microscale trigeneration system integrated with TABS will be developed and compared with a real life test-rig corresponding to building management systems. Data from the experimental analysis will be used to develop control algorithms using model predictive control for achieving the thermal comfort of occupants in the most energy efficient and grid reactive manner. The scope of this work encompasses adsorption cooling based microscale trigeneration systems and their deployment in residential and light commercial buildings.
Drawing off the technical flexibility of building polygeneration systems to support a rapidly expanding renewable electricity grid requires the application of advanced controllers like model predictive control (MPC) that can handle multiple inputs and outputs, uncertainties in forecast data, and plant constraints amongst other features. In this original work, an economic-MPC-based optimal scheduling of a real-world building energy system is demonstrated and its performance is evaluated against a conventional controller. The demonstration includes the steps to integrate an optimisation-based supervisory controller into a standard building automation and control system with off-the-shelf HVAC components and usage of state-of-art algorithms for solving complex nonlinear mixed integer optimal control problems. With the MPC, quantitative benefits in terms of 6–12% demand-cost savings and qualitative benefits in terms of better controller adaptability and hardware-friendly operation are identified. Further research potential for improving the MPC framework in terms of field-level stability, minimising constraint violations, and inter-system communication for its deployment in a prosumer-network is also identified.
Experimental Investigation of the Air Exchange Effectiveness of Push-Pull Ventilation Devices
(2020)
The increasing installation numbers of ventilation units in residential buildings are driven by legal objectives to improve their energy efficiency. The dimensioning of a ventilation system for nearly zero energy buildings is usually based on the air flow rate desired by the clients or requested by technical regulations. However, this does not necessarily lead to a system actually able to renew the air volume of the living space effectively. In recent years decentralised systems with an alternating operation mode and fairly good energy efficiencies entered the market and following question was raised: “Does this operation mode allow an efficient air renewal?” This question can be answered experimentally by performing a tracer gas analysis. In the presented study, a total of 15 preliminary tests are carried out in a climatic chamber representing a single room equipped with two push-pull devices. The tests include summer, winter and isothermal supply air conditions since this parameter variation is missing till now for push-pull devices. Further investigations are dedicated to the effect of thermal convection due to human heat dissipation on the room air flow. In dependence on these boundary conditions, the determined air exchange efficiency varies, lagging behind the expected range 0.5 < εa < 1 in almost all cases, indicating insufficient air exchange including short-circuiting. Local air exchange values suggest inhomogeneous air renewal depending on the distance to the indoor apertures as well as the temperature gradients between in- and outdoor. The tested measurement set-up is applicable for field measurements.
Lithium-ion pouch cells with lithium titanate (Li4Ti5O12, LTO) anode and lithium nickel cobalt aluminum oxide (LiNi0.8Co0.15Al0.05O2, NCA) cathode were investigated experimentally with respect to their electrical (0.1C…4C), thermal (5 °C…50 °C) and long-time cycling behavior. The 16 Ah cell exhibits an asymmetric charge/discharge behavior which leads to a strong capacity-rate effect, as well as a significantly temperature-dependent capacity (0.37 Ah ∙ K−1) which expresses as additional high-temperature feature in the differential voltage plot. The cell was cycled for 10,000 cycles inbetween the nominal voltage limits (1.7–2.7 V) with a symmetric 4C constant-current charge/discharge protocol, corresponding to approx. 3400 equivalent full cycles. A small (0.192 mΩ/1000 cycles) but continuous increase of internal resistance was observed. Using electrochemical impedance spectroscopy (EIS), this could be identified to be caused by the NCA cathode, while the LTO anode showed only minor changes during cycling. The temperature-corrected capacity during 4C cycling exhibited a decrease of 1.28%/1000 cycles. The 1C discharge capacity faded by only 4.0% for CC discharge and 2.3% for CCCV discharge after 10,000 cycles. The cell thus exhibits very good internal-resistance stability and excellent capacity retention even under harsh (4C continuous) cycling, demonstrating the excellent stability of LTO as anode material.
This work presents the results of experimental operation of a solar-driven climate system using mixed-integer nonlinear model predictive control (MPC). The system is installed in a university building and consists of two solar thermal collector fields, an adsorption cooling machine with different operation modes, a stratified hot water storage with multiple inlets and outlets as well as a cold water storage. The system and the applied modeling approach is described and a parallelized algorithm for mixed-integer nonlinear MPC and a corresponding implementation for the system are presented. Finally, we show and discuss the results of experimental operation of the system and highlight the advantages of the mixed-integer nonlinear MPC application.
The present work describes an extension of current slope estimation for parameter estimation of permanent magnet synchronous machines operated at inverters. The area of operation for current slope estimation in the individual switching states of the inverter is limited due to measurement noise, bandwidth limitation of the current sensors and the commutation processes of the inverter's switching operations. Therefore, a minimum duration of each switching state is necessary, limiting the final area of operation of a robust current slope estimation. This paper presents an extension of existing current slope estimation algorithms resulting in a greater area of operation and a more robust estimation result.
Meeting the requirements of smart grids local, decentralized subnets will offer additional potentials to stabilize and compensate the utility grid mainly on the low voltage level. In a quite complex configuration these decentralized energy systems are combined power, heat and cooling power distributions. According to the regional and local availability of renewable energy sources advanced energy management concepts should consider climatic conditions as well as the state of the interacting utility grid and consumption profiles. The approach uses demonstrational setups to develop a forecast based energy management for trigeneration subnets by taking into account the running conditions of local electrical and thermal energy conversion units. This should lead to the best coverage of the demand and supporting/stabilizing the utility grid at the same time. For the first of three demonstrational projects the priorities of the subnet are given with the maximization of the CHP operation to substitute a major part of the heating and cooling power delivered by electric heaters or compression chillers.
Ziel und Tempo der Energiewende sind gesetzt. Der Ausstieg aus der Stromproduktion in Kernkraftwerken soll bis 2022 geschafft sein. Eine Elektrizitätserzeugung, die auf erneuerbaren Energien beruht, soll die bisherige Erzeugung auf der Grundlage von Kohle, Kernbrennstoffen und Erdgas bis 2050 stufenweise weitgehend ablösen und damit maßgeblich zu den Klimaschutzzielen der Bundesregierung beitragen. Der Weg zu diesen Zielen ist für die Beteiligten hingegen noch nicht deutlich einsehbar. Viele offene Fragestellungen technischer, ökonomischer, legislativer und gesellschaftlicher Natur verstellen den Blick auf eine klare Strategie zur Erreichung der energiepolitischen Ziele. Vielschichtige Aufgaben und immense Herausforderungen kommen mit der Mammutaufgabe „Energiewende“ auf Politik, Wirtschaft, Wissenschaft und Bevölkerung zu. Ein wichtiger Enabler für die erfolgreiche Integration von Wind- und Sonnenenergie sowie für neue Prozesse, Marktrollen und Technologien ist die Informations- und Kommunikationstechnologie (IKT). An diesem Punkt setzt die hier vorliegende Studie an.
To achieve Germany's climate targets, the industrial sector, among others, must be transformed. The decarbonization of industry through the electrification of heating processes is a promising option. In order to investigate this transformation in energy system models, high-resolution temporal demand profiles of the heat and electricity applications for different industries are required. This paper presents a method for generating synthetic electricity and heat load profiles for 14 industry types. Using this methodology, annual profiles with a 15-minute resolution can be generated for both energy demands. First, daily profiles for the electricity demand were generated for 4 different production days. These daily profiles are additionally subdivided into eight end-use application categories. Finally, white noise is applied to the profile of the mechanical drives. The heat profile is similar to the electrical but is subdivided into four temperature ranges and the two applications hot water and space heating. The space heating application is additionally adjusted to the average monthly outdoor temperature. Both time series were generated for the analysis of an electrification of industrial heat application in energy system modelling.
Der Einbau von Smart Metern und deren intelligente Vernetzung in Richtung eines Smart Grid wird Stromverbrauchsmuster bis in die Haushalte hinein verändern. Über die technisch geprägte Diskussion um die Komponenten dafür darf deshalb keinesfalls die Einbeziehung der Gesellschaft in den anstehenden Wandel vergessen werden. Transparenz bei den Kosten, die Förderung von Vertrauen insbesondere in die Datenschutzstandards und eine verständliche Aufklärungsarbeit sind Schlüssel für den notwendigen Dialog zwischen Energieversorgern, Politik und Bürgern.