Refine
Year of publication
Document Type
- Conference Proceeding (344)
- Article (reviewed) (135)
- Article (unreviewed) (94)
- Book (33)
- Part of a Book (31)
- Patent (30)
- Letter to Editor (13)
- Contribution to a Periodical (8)
- Report (2)
- Doctoral Thesis (1)
Conference Type
- Konferenzartikel (235)
- Konferenz-Abstract (75)
- Sonstiges (22)
- Konferenz-Poster (9)
- Konferenzband (3)
Language
- English (460)
- German (227)
- Other language (2)
- Multiple languages (1)
- Russian (1)
- Spanish (1)
Has Fulltext
- no (692) (remove)
Is part of the Bibliography
- yes (692) (remove)
Keywords
- RoboCup (20)
- Kommunikation (15)
- Mathematik (12)
- Eingebettetes System (8)
- Intelligentes Stromnetz (8)
- Brennstoffzelle (7)
- CST (7)
- Energieversorgung (7)
- HF-Ablation (7)
- Herzkrankheit (7)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (692) (remove)
Open Access
- Closed Access (244)
- Open Access (221)
- Closed (73)
- Bronze (56)
- Diamond (1)
- Grün (1)
Learning to Walk With Toes
(2020)
This paper explains how a model-free (with respect to the robot model and the behavior to learn) approach can facilitate learning to walk from scratch. It is applied to a simulated Nao robot with toes. Results show an improvement of 30% in speed compared to a model without toes and also compared to our model-based approach, but with less stability.
Oesophageal Electrode Probe and Device for Cardiological Treatment and/or Diagnosis (EP3706626A1)
(2020)
The invention relates to an oesophageal electrode probe (10) for bioimpedance measurement and/or for neurostimulation; a device (100) for transoesophageal cardiological treatment and/or cardiological diagnosis; and a method for the open-loop or closed-loop control of a cardiac catheter ablation device and/or a cardiac, circulatory and/or respiratory support device. The oesophageal electrode probe comprises a bioimpedance measuring device for measuring the bioimpedance of at least one part of the tissue surrounding the oesophageal electrode probe. The bioimpedance device comprises at least one first and one second electrode, wherein the at least one first electrode (12A) is arranged on a side (14) of the oesophageal electrode probe facing towards the heart and the at least one second electrode (12B) is arranged on a side (16) of the oesophageal electrode probe facing away from the heart. The device (100) comprises the oesophageal electrode probe (10) and a control and/or evaluation device (30), which is configured for receiving a first bioimpedance measurement signal from the at least one first electrode (12A) and a second bioimpedance measurement signal from the at least one second electrode (12B), and comparing same, and generating a control signal on the basis of the comparison. The control signal can be a signal for the open-loop or closed-loop control of a cardiac catheter ablation device and/or a cardiac, circulatory and/or respiratory support device.
Verfahren zur Bestimmung von Eigenschaften einer Rohrleitung, insbesondere der Position eines Abzweigs einer Abwasserrohrleitung,(a) bei dem ein Schallwellensendesignal (S, S') an einem vorgegebenen Einspeisepunkt in die Rohrleitung (1) eingespeist wird und sich in axialer Richtung der Rohrleitung (1) ausbreitet,(b) wobei das Frequenzspektrum des Schallwellensendesignals (S, S') eine Frequenzkomponente oder einen Spektralbereich aufweist, dessen maximale Frequenz kleiner ist als die untere Grenzfrequenz (f) für die erste Obermode,(c) bei dem innerhalb der Rohrleitung (1) reflektierte Anteile (S, S, S, S', S', S') des Schallwellensendesignals (S, S') als Schallwellenempfangssignal (E, E') detektiert werden, und(d) bei dem die Rohrleitung (1) durch eine Auswertung des Schallwellenempfangssignal (E, E') in Bezug auf das Schallwellensendesignal (S, S') hinsichtlich des Vorhandenseins von Schallwellenreflexionen (S, S, S, S', S', S') verursachenden Reflexionsorten entlang der Rohrleitung (1) untersucht wird,(e) wobei mittels der Auswertung des Schallwellenempfangssignals (E, E') zumindest jeweils der Abstand (I) eines Reflexionsortes von dem Einspeisepunkt bestimmt wird, dadurch gekennzeichnet,(f) dass die Schallgeschwindigkeit (c) der Grundmode bei der aktuellen Temperatur innerhalb der Rohrleitung (1) unter Verwendung eines Schallwellenmesssignals ermittelt wird, welches eine Frequenz oder ein Frequenzspektrum aufweist, bei dem das Schallwellenmesssignal innerhalb der Rohrleitung (1) mit ausreichender Genauigkeit als ebene Schallwelle behandelt werden kann, wobei hierzu die Laufzeiten des Schallwellenmesssignals über eine vorbekannte Strecke (L) in beiden Richtungen gemessen wird,(g) dass die so ermittelte Schallgeschwindigkeit (c) einer ebenen Schallwelle gleich der tatsächlichen Schallgeschwindigkeit der Grundmode bei der aktuellen Temperatur innerhalb der Rohrleitung (1) gesetzt wird, und(h) dass die so bestimmte Schallgeschwindigkeit zur Bestimmung des Abstand (I) eines Reflexionsortes von dem Einspeisepunkt verwendet wird.
Die Erfindung betrifft eine Ösophaguselektrodensonde bzw. einen Ösophaguskatheter 10 zur Bioimpedanzmessung und/oder zur Neurostimulation, eine Vorrichtung 100 zur transösophagealen kardiologischen Behandlung und/oder kardiologischen Diagnose und ein Verfahren zum Steuern oder Regeln einer Ablationseinrichtung zum Durchführen einer Herzablation. Die Ösophaguselektrodensonde 10 umfasst eine Bioimpedanzmesseinrichtung zur Messung der Bioimpedanz von zumindest einem Teil des die Ösophaguselektrodensonde 10 umgebenden Gewebes. Die Bioimpedanzmesseinrichtung umfasst mindestens eine erste Elektrode 12A und mindestens eine zweite Elektrode 12B, wobei die mindestens eine erste Elektrode 12A auf einer dem Herzen zugewandten Seite 14 der Ösophaguselektrodensonde 10 angeordnet ist, und die mindestens eine zweite Elektrode 12B auf einer vom Herzen abgewandten Seite 16 der Ösophaguselektrodensonde 10 angeordnet ist.Die Vorrichtung 100 umfasst die Ösophaguselektrodensonde 10 und eine Steuer- und/oder Auswerteinrichtung 30. Die Steuer- und/oder Auswerteinrichtung 30 ist eingerichtet, ein erstes Bioimpedanzmesssignal von der mindestens einen ersten Elektrode 12A und ein zweites Bioimpedanzmesssignal von der mindestens einen zweiten Elektrode 12B zu empfangen und zu vergleichen, und ein Kontrollsignal auf Basis des Vergleichs zu generieren. Das Kontrollsignal kann ein Signal zum Steuern oder Regeln einer Ablationseinrichtung zum Durchführen einer Herzablation sein.
Auf Grundlage der Computer-Aided-Design (CAD)-rekonstruierten ersten „Eisernen Hand“ des Götz von Berlichingen wird ein umgebautes, controllergesteuertes sensomotorisches Fingersystem auf seine Funktionalität beim Greifen von unterschiedlichen Gegenständen beschrieben und geprüft. Die elektronischen Finger, die den „Pinzettengriff“ nachahmen und automatisch bei dem zuvor eingestellten Anpressdruck abschalten, bewiesen eine bemerkenswerte Alltagstauglichkeit. Das vorgestellte Grundkonzept könnte eine Alternative bei der Entwicklung einfacher und kostengünstiger, aber dennoch gut einsatzfähiger bionischer Hände sein und zeigt einmal mehr, wie historische Ideen in die Gegenwart transferiert werden können.
The Baroque composer Johann Sebastian Bach (1685–1750) has left us with many puzzles. The well-known oil painting by Elias Gottlob Haußmann is the only painting for which Bach actually posed in person. According to this portrait, Bach must have been quite obese. The cheeks and nose are flushed – possibly as signs of hypertension – and the eye lids are narrow – a sign of myopia. Furthermore, there is a thinning of the lateral third of the right eyebrow, which is known as Hertoghe’s sign, and indicated periorbital edema. Both signs are compatible with hypothyroidism. Bach might have been suffering from type-2 diabetes as the origin of his final illness, and the obituary reports two cataract surgeries by oculist John Taylor in March/April 1750, and, four months later, “apoplexy” followed by a high fever, of which Bach died. It may be speculated, however, that Bach’s entire illness was the result of his presumed obesity, possibly in combination with hypothyroidism.
In this paper, we present a frame synchronization method which consists of the non-orthogonal superposition of a synchronization sequence and the data. We derive the optimum detection criterion and compare it to the classical sequential concatenation of synchronization and data sequences. Computer simulations confirm the benefits of the non-orthogonal allocation for the case of short frames, which makes this technique particularly suited for the increasingly important regime of low latency and ultra- reliable communication.
Hintergrund: Richtung und Stärke des elektrischen Feldes (E-Feld) der biventrikulären (BV) Stimulation und elektrische interventrikuläre Desynchronisation sind bei Patienten mit Herzinsuffizienz und verbreitertem QRS Komplex von Bedeutung für den Erfolg der kardialen Resynchronisationstherapie (CRT). Das 3D Herzrhythmusmodell (HRM) ermöglicht die
Simulation von CRT und Hochfrequenz (HF) Ablation. Das Ziel der Studie besteht in der Integration von Schrittmacher- und Ablationselektroden in das HRM zur E-Feld Simulation der BV Stimulation und thermischen Feld (T-Feld) Simulation der HF Ablation von Vorhofflimmern (AF).
Methoden: Es wurden fünf multipolare linksventrikuläre (LV) Elektroden, eine epikardiale LV Elektrode, vier bipolare rechtsatriale (RA) Elektroden, zwei rechtsventrikuläre (RV) Elektroden und ein HF Ablationskatheter mit CST (Computer Simulation Technology, Darmstadt) modelliert und das HRM (Schalk et al: Clin Res Cardiol 106, Suppl 1, April 2017, P1812) um den Koronarvenensinus (CS) erweitert (HRM-CS). E-Feld Simulationen bei vorhofsynchroner BV Stimulation und bei RA Stimulation mit RV und LV Ableitung erfolgten mit den Elektroden Select Secure 3830, Capsure VDD-2 5038 und Attain OTW 4194 im HRM+CS (Fig.). F-Feld Simulationen der HF Ablation von AF bei CRT wurden mit integriertem Ablationskatheter AlCath G FullCircle (Biotronik) simuliert.
Ergebnisse: HRM-CS ermöglichte 3D E-Feld Simulationen bei vorhofsynchroner bipolarer BV Stimulation und bei bipolarer RA Stimulation mit bipolarer RV und LV Ableitung. RV und LV Stimulation erfolgten zeitgleich bei einer Amplitude von 3 V an der LV Elektrode und 1 V an der RV Elektrode mit einer Impulsbreite von jeweils 0,5 ms. Die von der BV Stimulationen erzeugten Fernpotentiale konnten von der RA Elektrode wahrgenommen werden. Das Fernpotential an der RA Elektrodenspitze betrug 32,86 mV und in 1 mm Abstand von der RA Elektrodenspitze ergab sich ein Fernpotential von 185,97 mV. HRM-CS ermöglichte 3D T-Feld Simulationen der HF Ablation von AF bei CRT. Das T-Feld bei HF Ablation des AV-Knotens wurde mit einer anliegenden Leistung von 5 W bei 420 kHz an der distalen 8 mm Ablationselektrode simuliert. Die Temperatur an der Katheterspitze betrug nach 5 s Ablationsdauer 88,66 °C, in 1 mm Abstand von der Katheterspitze im Myokard 42,17 °C und in 2 mm Abstand 37,49 °C.
Schlussfolgerungen: HRM-CS und Elektrodenmodelle ermöglichen die 3D Simulationen von E-Feldern bei vorhofsynchroner BV Stimulation, RA Stimulation mit RV und LV Wahrnehmung und von T-Feldern bei HF Ablation. E-Feld Simulationen von RA, RV und LV Stimulation und Sensing können möglicherweise zur Vorhersage von CRT Respondern genutzt werden.
This paper deals with the detection and segmentation of clouds on high-dynamic-range (HDR) images of the sky as well as the calculation of the position of the sun at any time of the year. In order to predict the movement of clouds and the radiation of the sun for a short period of time, the clouds thickness and position have to be known as precisely as possible. Consequently, the segmentation algorithm has to provide satisfactory results regardless of different weather, illumination and climatic conditions. The principle of the segmentation is based on the classification of each pixel as a cloud or as a sky. This classification is usually based on threshold methods, since these are relatively fast to implement and show a low computational burden. In order to predict if and when the sun will be covered by clouds, the position of the sun on the images has to be determined. For this purpose, the zenith and azimuth angles of the sun are determined and converted into XY coordinates.
Solar irradiance prediction is vital for the power management and the cost reduction when integrating solar energy. The study is towards a ground image based solar irradiance prediction which is highly dependent on the cloud coverage. The sky images are collected by using ground based sky imager (fisheye lens). In this work, different algorithms for cloud detection being a preparation step for their segmentation are compared.
The fisheye camera has been widely studied in the field of ground based sky imagery and robot vision since it can capture a wide view of the scene at one time. However, serious image distortion is a major drawback hindering its wider use. To remedy this, this paperproposes a lens calibration and distortion correction method for detecting clouds and forecasting solar radiation. Finally, the radial distortion of the fisheye image can be corrected by incorporating the estimated calibration parameters. Experimental results validate the effectiveness of the proposed method.
Die Hersteller von Cochlea-Implantat (CI)-Systemen sehen für klinische Audiologen die Möglichkeit vor, die Mikrofonleistung der meisten aktuellen CI-Sprachprozessoren mittels anschließbarer Monitorkopfhörer zu prüfen. Nähere Angaben dazu, nach welchem Prozedere diese Prüfung stattfinden soll, z. B. welche Stimuli mit welchen Pegeln verwendet werden sollen, sind nach Wissen der Autoren seitens der CI-Hersteller nicht verfügbar. Auf der Basis dieser subjektiven Prüfung entscheidet dann der Audiologe, ob der betreffende Sprachprozessor an den Hersteller eingeschickt wird oder nicht. Wir haben eine Messbox entwickelt, mit der die Mikrofonleistung aller abhörbaren CI-Sprachprozessoren der Hersteller Advanced Bionics, Cochlear und MED-EL objektiv geprüft werden kann. Die Box wurde im 3-D-Druckverfahren hergestellt. Der zu prüfende Sprachprozessor wird in die Messbox eingehängt und über einen verbauten Lautsprecher mit definierten Prüfsignalen (Sinustönen unterschiedlicher Frequenz) beschallt. Das Signal des Mikronfons bzw. der Mikrofone wird über das in der Audio-/Abhörbuchse des Prozessors eingesteckte Kabel der Monitorkopfhörer herausgeführt und mit einer Shifting and Scaling-Schaltung in einen Spannungsbereich transformiert, der für die A/D-Wandlung mit einem Mikrokontroller (ATmega1280 verbaut auf einem Arduino Mega) geeignet ist. Derselbe Mikrokontroller übernimmt über einen eigens gebauten D/AWandler die Ausgabe der Prüfsignale über den Lautsprecher. Signalaufnahme und –wiedergabe erfolgt jeweils mit einer Samplingrate von 38,5 kHz. Der frequenzspezifische Effektivwert des abgegriffenen Mikrofonsignals wird mit einem Referenzwert verglichen. Die (frequenzspezifischen) Referenzwerte wurden mit einem neuwertigen Sprachprozessor gleichen Typs ermittelt und im Speicher des Mikrokontrollers abgelegt. Das Ergebnis wird nach Abschluss der Messung grafisch auf einem Touchscreen ausgegeben. Derzeit läuft eine erste Datenerhebung mit in der Klinik subjektiv auffällig gewordenen CI-Sprachprozessoren, die anschließend in der Messbox untersucht werden. Längerfristiges Ziel ist es, die hit und false alarm Raten der subjektiven Prüfung zu ermitteln.
Cardiac resynchronization therapy (CRT) with hemodynamic optimized biventricular pacing is an established therapy for heart failure patients with sinus rhythm, reduced left ventricular ejection fraction and wide QRS complex. The aim of the study was to evaluate electrical right and left cardiac atrioventricular delay and left atrial delay in CRT responder and non-responder with sinus rhythm.
Methods: Heart failure patients with New York Heart Association class 3.0 ± 0.3, sinus rhythm and 27.7 ± 6.1% left ventricular ejection fraction were measured by surface ECG and transesophageal bipolar left atrial and left ventricular ECG before implantation of CRT devices. Electrical right cardiac atrioventricular delay was measured between onset of P wave and onset of QRS complex in the surface ECG, left cardiac atrioventricular delay between onset of left atrial signal and onset of left ventricular signal in the transesophageal ECG and left atrial delay between onset and offset of left atrial signal in the transesophageal ECG.
Results: Electrical atrioventricular and left atrial delay were 196.9 ± 38.7 ms right and 194.5 ± 44.9 ms left cardiac atrioventricular delay, and 47.7 ± 13.9 ms left atrial delay. There were positive correlation between right and left cardiac atrioventricular delay (r = 0.803 P < 0.001) and negative correlation between left atrial delay and left ventricular ejection fraction (r = −0.694 P = 0.026) with 67% CRT responder.
Conclusions: Transesophageal electrical left cardiac atrioventricular delay and left atrial delay may be useful preoperative atrial desynchronization parameters to improve CRT optimization.
Targeting complex fractionated atrial electrocardiograms by automated algorithms during ablation of persistent atrial fibrillation has produced conflicting outcomes in previous electrophysiological studies and catheter ablation of atrial fibrillation and ventricular tachycardia. The aim of the investigation was to evaluate atrial and ventricular high frequency fractionated electrical signals with signal averaging technique.
Methods: Signal averaging electrocardigraphy allows high resolution ECG technique to eliminate interference noise signals in the recorded ECG. The algorithm use automatic ECG trigger function for signal averaged transthoracic, transesophageal and intra-cardiac ECG signals with novel LabVIEW software.
Results: The analysis in the time domain evaluated fractionated atrial signals at the end of the signal averaged P-wave and fractionated ventricular signals at the end of the QRS complex. We evaluated atrial flutter in the time domain with two-to-one atrioventricular conduction, 212.0 ± 4.1 ms atrial cycle length, 426.0 ± 8.2 ms ventricular cycle length, 58.2 ± 1.8 ms P-wave duration, 119.6 ± 6.4 ms PQ duration, 103.0 ± 2.4 ms QRS duration and 296.4 ± 6.8 ms QT duration. The analysis in the frequency domain evaluated high frequency fractionated atrial signals during the P-wave and high frequency fractionated ventricular signals during QRS complex.
Conclusions: Spectral analysis of signal averaging electrocardiography with novel LabVIEW software can be utilized to evaluate atrial and ventricular conduction delays in patients with atrial fibrillation and ventricular tachycardia. Complex fractionated atrial and ventricular electrocardiograms may be useful parameters to evaluate electrical cardiac bradycardia and tachycardia signals in atrial fibrillation and ventricular tachycardia ablation.
In einer Vorlesung nicht abgehängt zu werden und die vielen Ergebnisse strukturiert zu sichern, ist für Studienanfänger eine große Herausforderung. Mitschriebe sind sehr oft unvollständig, unstrukturiert oder „zerfläddert“. Mitschreib-Marathon und Mitdenken schließen sich bei vielen aus. Auch aktivierende Lehrmethoden, Medienwechsel, Lehrvideos führen oft dazu, dass eine strukturierte Sicherung der Inhalte des Lehrgesprächs noch erschwert wird.
Es wird ein Best Practice Beispiel gezeigt, Mathematik-Vorlesungen über ein Tablet-basiertes Mitmach-Skript zu gestalten. Dieses dient als Schrittmacher zwischen Input- und Verarbeitungsphasen und unterstützt die strukturierte Verschriftlichung, indem es Vorteile von Tafel, PPT und klassischem Skript vereint. Traditionelle Methoden werden mit technologischen Möglichkeiten kombiniert, um die angesprochenen Herausforderungen bewusster im Lehrstil zu berücksichtigen. Verbindungen zu Virtual Classroom und Video-gestützter Lehre werden aufgezeigt.
This paper describes the use of the single-linkage hierarchical clustering method in outlier detection for manufactured metal work pieces. The main goal of the study is to group defects that occur 5 mm into a work piece from the edge, i.e., the border of the metal work piece. The goal is to remove defects outside the area of interest as outliers. According to the assumptions made for the performance criteria, the single-linkage method has achieved better results compared to other agglomeration methods.
In public transportation, the motor pool often consists of various different vehicles bought over a duration of many years. Sometimes, they even differ within one batch bought at the same time. This poses a considerable challenge in the storage and allocation of spare parts, especially in the event of damage to a vehicle. Correctly assigning these parts before the vehicle reaches the workshop could significantly reduce both the downtime and, therefore, the actual costs for companies. In order to achieve this, the current software uses a simple probability calculation. To improve the performance, the data of specific companies was analysed, preprocessed and used with several modelling techniques to classify and, therefore, predict the spare parts to be used in the event of a faulty vehicle. We summarize our experience running through the steps of the Cross Industry Standard Process for Data Mining and compare the performance to the previously used probability. Gradient Boosting Trees turned out to be the best modeling technique for this special case.
Data Science gilt als eine der wichtigsten Entwicklungen der letzten
Jahre und viele Unternehmen sehen in Data Science die Möglichkeit,
ihre Daten zusätzlich wertschöpfend zu nutzen. Dabei kann es sich um
die Optimierung von Maintenance-Prozessen handeln, um eine bessere
Steuerung der eigenen Preis- und Lagerhaltungsstrategie oder auch
um völlig neue Services und Produkte, die durch Data Science möglich
werden. Die im Unternehmen vorliegenden Daten, an die so hohe Erwartungen
geknüpft wurden, sollen dazu genutzt werden, um Services
und Prozesse effizienter und passgenauer gestalten zu können. Vielfach
gilt Data Science dabei als Allheilmittel: Daten, die über Jahre hinweg
gesammelt wurden und mit zunehmender Geschwindigkeit und Heterogenität
anfallen, sollen endlich nutzbar gemacht werden. Zwar sind die
eingesetzten Techniken und Algorithmen teilweise schon zehn Jahre und
mehr alt, doch erst jetzt entfalten sie im Zusammenspiel mit Big Data
ihr Potenzial im Unternehmensumfeld. Die Erwartungen sind hoch, doch
der Weg zu den neuen Erkenntnissen ist mit hohem Aufwand verbunden
und wird von einigen Unternehmen noch immer unterschätzt.
Für Unternehmen mit einem traditionellen BI-Ansatz stellt Data Science
ein ergänzendes Set von Methoden und Werkzeugen dar, mit deren Hilfe
die Informationsversorgung der Entscheider auf den verschiedenen
hierarchischen Ebenen noch besser gestaltet werden kann. So zum Beispiel,
wenn man mit Data Science feststellt, dass die Wahrscheinlichkeit
für einen Versicherungsabschluss steigt, wenn bei der Auswahl der
anzusprechenden Kunden zusätzliche Daten herangezogen werden, die
zwar bereits vorliegen, aber noch nicht berücksichtigt worden sind. Im
Extremfall werden auch Entscheidungen vollständig automatisiert, die
bisher von Mitarbeiterinnen und Mitarbeitern getroffen wurden. Ein Algorithmus
legt dann fest, wann Ware nachbestellt oder welcher Preis für
den Endkunden festgesetzt wird.
Im vorliegenden E-Book soll ein Überblick über das Gebiet Data Science
gegeben werden. Dabei wird ein besonderes Augenmerk auf das Zusammenspiel
sowie das Mit- und Nebeneinander von Data Science und vorhandenen
BI-Systemen gelegt.
Oxide semiconductors are highly promising candidates for the most awaited, next-generation electronics, namely, printed electronics. As a fabrication route for the solution-processed/printed oxide semiconductors, photonic curing is becoming increasingly popular, as compared to the conventional thermal curing method; the former offers numerous advantages over the latter, such as low process temperatures and short exposure time and thereby, high throughput compatibility. Here, using dissimilar photonic curing concepts (UV–visible light and UV-laser), we demonstrate facile fabrication of high performance In2O3 field-effect transistors (FETs). Beside the processing related issues (temperature, time etc.), the other known limitation of oxide electronics is the lack of high performance p-type semiconductors, which can be bypassed using unipolar logics from high mobility n-type semiconductors alone. Interestingly, here we have found that our chosen distinct photonic curing methods can offer a large variation in threshold voltage, when they are fabricated from the same precursor ink. Consequently, both depletion and enhancement-mode devices have been achieved which can be used as the pull-up and pull-down transistors in unipolar inverters. The present device fabrication recipe demonstrates fast processing of low operation voltage, high performance FETs with large threshold voltage tunability.
A printed electronics technology has the advantage of additive and extremely low-cost fabrication compared with the conventional silicon technology. Specifically, printed electrolyte-gated field-effect transistors (EGFETs) are attractive for low-cost applications in the Internet-of-Things domain as they can operate at low supply voltages. In this paper, we propose an empirical dc model for EGFETs, which can describe the behavior of the EGFETs smoothly and accurately over all regimes. The proposed model, built by extending the Enz-Krummenacher-Vittoz model, can also be used to model process variations, which was not possible previously due to fixed parameters for near threshold regime. It offers a single model for all the operating regions of the transistors with only one equation for the drain current. Additionally, it models the transistors with a less number of parameters but higher accuracy compared with existing techniques. Measurement results from several fabricated EGFETs confirm that the proposed model can predict the I-V more accurately compared with the state-of-the-art models in all operating regions. Additionally, the measurements on the frequency of a fabricated ring oscillator are only 4.7% different from the simulation results based on the proposed model using values for the switching capacitances extracted from measurement data, which shows more than 2× improvement compared with the state-of-the-art model.
Printed Electronics (PE) is a promising technology that provides mechanical flexibility and low-cost fabrication. These features make PE the key enabler for emerging applications, such as smart sensors, wearables, and Internet of Things (IoTs). Since these applications need secure communication and/or authentication, it is vital to utilize security primitives for cryptographic key and identification. Physical Unclonable Functions (PUF) have been adopted widely to provide the secure keys. In this work, we present a weak PUF based on Electrolyte-gated FETs using inorganic inkjet printed electronics. A comprehensive analysis framework including Monte Carlo simulations based on real device measurements is developed to evaluate the proposed PE-PUF. Moreover, a multi-bit PE-PUF design is proposed to optimize area usage. The analysis results show that the PE-PUF has ideal uniqueness, good reliability, and can operates at low voltage which is critical for low-power PE applications. In addition, the proposed multi-bit PE-PUF reduces the area usage around 30%.
This paper evaluates the implementation of Medium Access Control (MAC) protocols suitable for massive access connectivity in 5G multi-service networks. The access protocol extends multi-packet detection receivers based on Physical Layer Network Coding (PLNC) decoding and Coded Random Access protocols considering practical aspects to implement one-stage MAC protocols for short packet communications in mMTC services. Extensions to enhance data delivery phase in two- stage protocols are also proposed. The assessment of the access protocols is extended under system level simulations where a suitable link to system interface characterization has been taken into account.
In this paper, we establish a simple model for the exchange of messages in a vehicular network and we consider fundamental limits on the achievable data rate. For a vehicular network, the exchange of data with other nearby vehicles is particularly important for traffic safety, e.g. for collision avoidance, but also for cooperative applications like platooning. These use cases are currently addressed by standards building on IEEE 802.11p, namely ITS-G5 and DSRC (dedicated short range communication), which encounter saturation problems at high vehicle densities. For this reason, we take a step back and ask for the fundamental limits for the common data rate in a vehicular network. After defining a simple single-lane model and the corresponding capacity limits for some basic multiple- access schemes, we present results for a more realistic setting. For both scenarios, non-orthogonal multiple-access (NOMA) yields the best results.
Online comment on: "Printing ferromagnetic domains for untethered fast-transforming soft materials"
(2018)
A method for determining properties of a pipeline includes feeding a sound wave signal at a predetermined feed point into the pipeline so that the sound wave signal propagates in an axial direction of the pipeline. The frequency spectrum of the transmitted sound wave signal has a frequency component or a spectral range with a maximum frequency that is smaller than the lower limit frequency for the first upper mode. Reflected portions of the transmitted sound wave signal are detected as received sound wave signal and are evaluated with regard to the transmitted sound wave signal to determine at least the distance of each reflection site from the feed point.
Real-Time Ethernet has become the major communication technology for modern automation and industrial control systems. On the one hand, this trend increases the need for an automation-friendly security solution, as such networks can no longer be considered sufficiently isolated. On the other hand, it shows that, despite diverging requirements, the domain of Operational Technology (OT) can derive advantage from high-volume technology of the Information Technology (IT) domain. Based on these two sides of the same coin, we study the challenges and prospects of approaches to communication security in real-time Ethernet automation systems. In order to capitalize the expertise aggregated in decades of research and development, we put a special focus on the reuse of well-established security technology from the IT domain. We argue that enhancing such technology to become automation-friendly is likely to result in more robust and secure designs than greenfield designs. Because of its widespread deployment and the (to this date) nonexistence of a consistent security architecture, we use PROFINET as a showcase of our considerations. Security requirements for this technology are defined and different well-known solutions are examined according their suitability for PROFINET. Based on these findings, we elaborate the necessary adaptions for the deployment on PROFINET.
The Transport Layer Security (TLS) protocol is a cornerstone of secure network communication, not only for online banking, e-commerce, and social media, but also for industrial communication and cyber-physical systems. Unfortunately, implementing TLS correctly is very challenging, as becomes evident by considering the high frequency of bugfixes filed for many TLS implementations. Given the high significance of TLS, advancing the quality of implementations is a sustained pursuit. We strive to support these efforts by presenting a novel, response-distribution guided fuzzing algorithm for differential testing of black-box TLS implementations. Our algorithm generates highly diverse and mostly-valid TLS stimulation messages, which evoke more behavioral discrepancies in TLS server implementations than other algorithms. We evaluate our algorithm using 37 different TLS implementations and discuss―by means of a case study―how the resulting data allows to assess and improve not only implementations of TLS but also to identify underspecified corner cases. We introduce suspiciousness as a per-implementation metric of anomalous implementation behavior and find that more recent or bug-fixed implementations tend to have a lower suspiciousness score. Our contribution is complementary to existing tools and approaches in the area, and can help reveal implementation flaws and avoid regression. While being presented for TLS, we expect our algorithm's guidance scheme to be applicable and useful also in other contexts. Source code and data is made available for fellow researchers in order to stimulate discussions and invite others to benefit from and advance our work.
Die Heterogenität der Studienanfänger/innen erleben viele Lehrende unmittelbar in den Anfängerveranstaltungen, Heterogenität nicht nur in Bezug auf fachliche Vorbildung, sondern auch bezüglich verfügbaren Lernstrategien, Fertigkeiten, Motivation und
Selbstdisziplin. Schon allein einer 90-minütigen Vorlesung konzentriert zu folgen und die
Ergebnisse strukturiert zu sichern, ist für viele eine sehr große Herausforderung. In diesem Erfahrungsbericht wird das seit dem WS 2015/16
an der Hochschule Offenburg erprobte Potenzial moderner Tablets untersucht, Vorteile
von klassischem handschriftlichen An- und Mitschreiben mit einer Vorstruktur, wie sie
z.B. PPT-Slides ermöglichen, zu vereinen.
Recently, the demand for scalable, efficient and accurate Indoor Positioning Systems (IPS) has seen a rising trend due to their utility in providing Location Based Services (LBS). Visible Light Communication (VLC) based IPS designs, VLC-IPS, leverage Light Emitting Diodes (LEDs) in indoor environments for localization. Among VLC-based designs, Time Difference of Arrival (TDOA) based techniques are shown to provide very low errors in the relative position of receivers. Our considered system consists of five LEDs that act as transmitters and a single receiver (photodiode or image sensor in smart phone) whose position coordinates in an indoor environment are to be determined. As a performance criterion, Cramer Rao Lower Bound (CRLB) is derived for range estimations and the impact of various factors, such as, LED transmission frequency, position of reference LED light, and the number of LED lights, on localization accuracy has been studied. Simulation results show that depending on the optimal values of these factors, location estimation on the order of few centimeters can be realistically achieved.
The Datagram Transport Layer Security (DTLS) protocol has been designed to provide end-to-end security over unreliable communication links. Where its connection establishment is concerned, DTLS copes with potential loss of protocol messages by implementing its own loss detection and retransmission scheme. However, the default scheme turns out to be suboptimal for links with high transmission error rates and low data rates, such as wireless links in electromagnetically harsh industrial environments. Therefore, in this paper, as a first step we provide an analysis of the standard DTLS handshake's performance under such adverse transmission conditions. Our studies are based on simulations that model message loss as the result of bit transmission errors. We consider several handshake variants, including endpoint authentication via pre-shared keys or certificates. As a second step, we propose and evaluate modifications to the way message loss is dealt with during the handshake, making DTLS deployable in situations which are prohibitive for default DTLS.
The excessive control signaling in Long Term Evolution networks required for dynamic scheduling impedes the deployment of ultra-reliable low latency applications. Semi-persistent scheduling was originally designed for constant bit-rate voice applications, however, very low control overhead makes it a potential latency reduction technique in Long Term Evolution. In this paper, we investigate resource scheduling in narrowband fourth generation Long Term Evolution networks through Network Simulator (NS3) simulations. The current release of NS3 does not include a semi-persistent scheduler for Long Term Evolution module. Therefore, we developed the semi-persistent scheduling feature in NS3 to evaluate and compare the performance in terms of uplink latency. We evaluate dynamic scheduling and semi-persistent scheduling in order to analyze the impact of resource scheduling methods on up-link latency.
The paper describes the methodology and experimental results for revealing similarities in thermal dependencies of biases of accelerometers and gyroscopes from 250 inertial MEMS chips (MPU-9250). Temperature profiles were measured on an experimental setup with a Peltier element for temperature control. Classification of temperature curves was carried out with machine learning approach.
A perfect sensor should not have thermal dependency at all. Thus, only sensors inside the clusters with smaller dependency (smaller total temperature slopes) might be pre-selected for production of high accuracy inertial navigation modules. It was found that no unified thermal profile (“family” curve) exists for all sensors in a production batch. However, obviously, sensors might be grouped according to their parameters. Therefore, the temperature compensation profiles might be regressed for each group. 12 slope coefficients on 5 degrees temperature intervals from 0°C to +60°C were used as the features for the k-means++ clustering algorithm.
The minimum number of clusters for all sensors to be well separated from each other by bias thermal profiles in our case is 6. It was found by applying the elbow method. For each cluster a regression curve can be obtained.
The next generation cellular networks are expected to improve reliability, energy efficiency, data rate, capacity and latency. Originally, Machine Type Communication (MTC) was designed for low-bandwidth high-latency applications such as, environmental sensing, smart dustbin, etc., but there is additional demand around applications with low latency requirements, like industrial automation, driver-less cars, and so on. Improvements are required in 4G Long Term Evolution (LTE) networks towards the development of next generation cellular networks for providing very low latency and high reliability. To this end, we present an in-depth analysis of parameters that contribute to the latency in 4G networks along with a description of latency reduction techniques. We implement and validate these latency reduction techniques in the open-source network simulator (NS3) for narrowband user equipment category Cat-Ml (LTE-M) to analyze the improvements. The results presented are a step towards enabling narrowband Ultra Reliable Low Latency Communication (URLLC) networks.
Vehicle-to-Everything (V2X) communication promises improvements in road safety and efficiency by enabling low-latency and reliable communication services for vehicles. Besides using Mobile Broadband (MBB), there is a need to develop Ultra Reliable Low Latency Communications (URLLC) applications with cellular networks especially when safety-related driving applications are concerned. Future cellular networks are expected to support novel latencysensitive use cases. Many applications of V2X communication, like collaborative autonomous driving requires very low latency and high reliability in order to support real-time communication between vehicles and other network elements. In this paper, we classify V2X use-cases and their requirements in order to identify cellular network technologies able to support them. The bottleneck problem of the medium access in 4G Long Term Evolution(LTE) networks is random access procedure. It is evaluated through simulations to further detail the future limitations and requirements. Limitations and improvement possibilities for next generation of cellular networks are finally detailed. Moreover, the results presented in this paper provide the limits of different parameter sets with regard to the requirements of V2X-based applications. In doing this, a starting point to migrate to Narrowband IoT (NB-IoT) or 5G - solutions is given.
Uncontrollable manufacturing variations in electrical hardware circuits can be exploited as Physical Unclonable Functions (PUFs). Herein, we present a Printed Electronics (PE)-based PUF system architecture. Our proposed Differential Circuit PUF (DiffC-PUF) is a hybrid system, combining silicon-based and PE-based electronic circuits. The novel approach of the DiffC-PUF architecture is to provide a specially designed real hardware system architecture, that enables the automatic readout of interchangeable printed DiffC-PUF core circuits. The silicon-based addressing and evaluation circuit supplies and controls the printed PUF core and ensures seamless integration into silicon-based smart systems. Major objectives of our work are interconnected applications for the Internet of Things (IoT).
Printed electronics offers certain technological advantages over its silicon based counterparts, such as mechanical flexibility, low process temperatures, maskless and additive manufacturing process, leading to extremely low cost manufacturing. However, to be exploited in applications such as smart sensors, Internet of Things and wearables, it is essential that the printed devices operate at low supply voltages. Electrolyte gated field effect transistors (EGFETs) using solution-processed inorganic materials which are fully printed using inkjet printers at low temperatures are very promising candidates to provide such solutions. In this paper, we discuss the technology, process, modeling, fabrication, and design aspect of circuits based on EGFETs. We show how the measurements performed in the lab can accurately be modeled in order to be integrated in the design automation tool flow in the form of a Process Design Kit (PDK). We also review some of the remaining challenges in this technology and discuss our future directions to address them.
The CAN bus still is an important fieldbus in various domains, e.g. for in-car communication or automation applications. To counter security threats and concerns in such scenarios we design, implement, and evaluate the use of an end-to-end security concept based on the Transport Layer Security protocol. It is used to establish authenticated, integrity-checked, and confidential communication channels between field devices connected via CAN. Our performance measurements show that it is possible to use TLS at least for non time-critical applications, as well as for generic embedded networks.
Nowadays, robotic systems are an integral part of many orthopedic interventions. Stationary robots improve the accuracy but also require adapted surgical workflows. Handheld robotic devices (HHRDs), however, are easily integrated into existing workflows and represent a more economical solution. Their limited range of motion is compensated by the dexterity of the surgeon. This work presents control algorithms for HHRDs with multiple degrees of freedom (DOF). These algorithms protect pre- or intraoperatively defined regions from being penetrated by the end effector (e.g., a burr) by controlling the joints as well as the device’s power. Accuracy tests on a stationary prototype with three DOF show that the presented control algorithms produce results similar to those of stationary robots and much better results than conventional techniques. This work presents novel and innovative algorithms, which work robustly, accurately, and open up new opportunities for orthopedic interventions.
Optische Navigationssysteme weisen bisher eine eindeutige Trennung zwischen nachverfolgendem Gerät (Tool Tracker) und nachverfolgten Geräten (Tracked Tools) auf. In dieser Arbeit wird ein neues Konzept vorgestellt, dass diese Trennung aufhebt: Jedes Tracked Tool ist gleichzeitig auch Tool Tracker und besteht aus Marker-LEDs sowie mindestens einer Kamera, mit deren Hilfe andere Tracker in Lage und Orientierung nachverfolgt werden können. Bei Verwendung von nur einer Kamera geschieht dies mittels Pose Estimation, ab zwei Kameras werden die Marker-LEDs trianguliert. Diese Arbeit beinhaltet die Vorstellung des neuen Peer-To-Peer-Tracking-Konzepts, einen sehr schnellen Pose-Estimation-Algorithmus für beliebig viele Marker sowie die Klärung der Frage, ob die mit Pose Estimation erreichbare Genauigkeit vergleichbar mit der eines Stereo-Kamera-Systems ist und den Anforderungen an die chirurgische Navigation gerecht wird.
This paper is discussing the development of a wireless Indoor Smart Gardening System with the focus on energy autonomous working. The Smart Gardening System, which is presented in this paper consists of a network of energy autonomous wireless sensor nodes which are used for monitoring important plant parameters like air temperature, soil moisture, pressure or humidity and in future to control an actuator for the plant irrigation and to measure further parameter as light and fertilizer level. Solar energy harvesting is used for powering the wireless nodes without the usage of a battery. Comparable Smart Gardening Systems are usually battery-powered. Furthermore, the overall Smart Gardening System consists of a battery powered gateway based on a Raspberry Pi 3 system, which controls the wireless nodes and collects their sensor data. The gateway is able to send the information to an internet server application and via Wi-Fi to mobile devices. Particularly the architecture of the energy autonomous wireless nodes will be considered because fully energy autonomous wireless networks could not be implemented without special concepts for the energy supply and architecture of the wireless nodes.
The high frequency (HF) catheter ablation is the gold standard for the therapy of many cardiac tachyarrhythmias, such as atrioventricular node re-entry tachycardia (AVNRT), atrioventricular re-entry tachycardia (AVRT) or atrial flutter (AFL). The aim of the study was to simulate the HF ablation of AVNRT, AVRT, AFL and its heat propagation in reference to the supplied power with different electrode material and electrode size. The modeling and simulation were performed with the thermal and electromagnetic simulation software CST® (Computer Simulation Technology, Darmstadt). The modeling and simulation were carried out using ablation catheters with 4 mm tip electrode and 8 mm tip electrode with different electrode materials. Both electrode types were made of platinum and gold respectively. For the measurement of the heat propagation in the heart tissue, the catheters were integrated in the Offenburg heart rhythm model. The HF ablation procedures were performed with the 4 mm platinum tip electrode, with an application duration of 45 seconds and a power output of 40 watts. The HF ablation of the atrioventricular node slow pathway produced a maximum temperature of 66.33 °C. The Kent bundle HF ablation in the left atrium achieved a maximum temperature of 67.14 °C. The HF ablation of the right atrial isthmus resulted 65.96 °C. The 8 mm distal platinum tip electrode and a power output of 60 watts reached 72.85 °C. The 8 mm distal gold tip electrode and a power output of 60 watt reached 64.66 °C, due to the improved thermal conductivity of gold. Virtual heart and ablation electrode models allow the static and dynamic simulation of HF ablation with different electrode material and electrode size. The 3D simulation of the temperature profile may be used to optimize the AVNRT, AVRT and AFL HF ablation.
Pulmonary vein isolation (PVI) is a common therapy in atrial fibrillation (AF). The cryoballoon was invented to isolate the pulmonary vein in one step and in a shorter time than a point-by-point radiofrequency (RF) ablation. The aim of the study was to model two cryoballoon catheters, one RF catheter and to integrate them into a heart rhythm model for the static and dynamic simulation of PVI by cryoablation and RF ablation in AF. The modeling and simulation were carried out using the electromagnetic and thermal simulation software CST (CST, Darmstadt). Two cryoballons and one RF ablation catheter were modeled based on the technical manuals of the manufacturers Medtronic and Osypka. The PVI especially the isolation of the left inferior pulmonary vein using a cryoballoon catheter was performed with a -50 °C heatsource and an exponential signal. The temperature at the balloon surface was -50 °C after 20 s ablation time, -24 °C from the balloon 0,5 mm in the myocardium, at a distance of 1 mm -3 °C, at 2 mm 18 °C and at a distance of 3mm 29 °C. PVI with RF energy was simulated with an applied power of 5 W at 420 kHz at the distal 8 mm ablation electrode. The temperature at the tip electrode was 110 °C after 15 s ablation time, 75 °C from the balloon at 0,5 mm in the myocardium, at a distance of 1 mm 58 °C, at 2 mm 45 °C and at a distance of 3 mm 38 °C. Virtual heart rhythm and catheter models as well as the simulation of the temperature allow the simulation of PVI in AF by cryo ablation and RF ablation. The 3D simulation of the temperature profile may be used to optimize RF and cryo ablation.
Cardiac contractility modulation (CCM) is a device-based therapy for the treatment of systolic left ventricular chronic heart failure. Unlike other device-based therapies for heart failure, CCM delivers non-excitatory pacing signals to the myocardium. This leads to an extension of the action potential and to an improved contractility of the heart. The modeling and simulation was done with the electromagnetic simulation software CST. Three CCM electrodes were inserted into the Offenburg heart rhythm model and subsequently simulated the electric field propagation in CCM therapy.
In addition, simulations of CCM have been performed with electrodes from other device-based therapies, such as cardiac resynchronization therapy (CRT) and implantable cardioverter / defibrillator (ICD) therapy. At the same distance to the simulation electrode, the electric field is slightly stronger in CCM therapy than in CCM therapy with additionally implanted CRT or ICD electrodes. In addition, there is a change in the electric field propagation at the electrodes of the CRT and the shock electrode of the ICD.
By simulating several different therapy procedures on the heart, it is possible to check how they affect their behavior during normal operation. CCM heart rhythm model simulation allows the evaluation the individual electrical pacing and sensing field during CCM.
Abstract: Electric field of biventricular (BV) pacing, left ventricular (LV) electrode position and electrical interventricular desynchronization are important parameters for successful cardiac resynchronization therapy (CRT) in patients with heart failure, sinus rhythm and reduced LV ejection fraction. The aim of the study was to evaluate electric pacing field of transesophageal left atrial (LA) pacing and BV pacing with 3D heart rhythm simulation. Bipolar right atrial (RA), right ventricular (RV), LV electrodes and multipolar hemispherical esophageal LA electrodes were modeled with CST (Computer Simulation Technology, Darmstadt). Electric pacing field were simulated with bipolar RA and RV pacing with Solid S (Biotronik) electrode, bipolar LV pacing with Attain 4194 (Medtronic) electrode and bipolar LA pacing with TO8 (Osypka) esophageal electrode. 3D heart rhythm model with esophagus allowed electric pacing field simulation of 4-chamber pacing with bipolar intracardiac RA, RV, LV pacing and bipolar transesophageal LA pacing. The pacing amplitudes were 3V RA pacing amplitude, 50V LA pacing amplitude, 1.5V RV pacing amplitude and 3V LV pacing amplitude with 0.5ms pacing pulse duration. The atrioventricular delay between RA pacing and BV pacing was 140ms atrioventricular pacing delay and simultaneous RV and LV pacing. Electric pacing fields were simulated during the different pacing modes AAI, VVI, DDD and DDD0V. The intracardiac far-field pacing potentials were evaluated with intracardiac electrodes and a distance of 1mm from the electrodes with RA electrode 1.104V, RV electrode 0.703V and LV electrode 1.32V. The transesophageal far-field pacing potential was evaluated with transesophageal electrode and a distance of 10mm from the elelctrode with LA electrode 6.076V. Heart rhythm model simulation with esophagus allows evaluation of electric pacing fields in AAI, VVI, DDD, DDD0V and DDD0D pacing modes. Electric pacing field of RA, RV and LV pacing in combination with LA pacing may additional useful pacing mode in CRT non-responders.
eLetter zu "Illusory movement perception improves motor control for prosthetic hands" von Paul D. Marasco et al., veröffentlicht in Science Translational Medicine, Vol. 10, No. 432 (DOI: 10.1126/scitranslmed.aao6990)
This paper describes the Sweaty II humanoid adult size robot trying to qualify for the RoboCup 2018 adult size humanoid competition. Sweaty came 2nd in RoboCup 2017 adult size league. The main characteristics of Sweaty are described in the Team Description Paper 2017. The improvements that have been made or are planned to be implemented for RoboCup 2018 are described in this paper.
In this TDP we describe a new tool created for testing the strategy layer of our soccer playing agents. It is a complete 2D simulator that simulates the games based on the decisions of 22 agents. With this tool, debugging the decision and strategy layer of our agents is much more efficient than before due to various interaction methods and complete control over the simulation.
In the future, the tool could also serve as a measure to run simulations of game series much faster than with the 3D simulator. This way, the impact of different play strategies could be evaluated much faster than before.
Am Buffet des Lebens
(2017)
Objectives: Speech recognition on the telephone poses a challenge for patients with cochlear implants (CIs) due to a reduced bandwidth of transmission. This trial evaluates a home-based auditory training with telephone-specific filtered speech material to improve sentence recognition. Design: Randomised controlled parallel double-blind. Setting: One tertiary referral centre. Participants: A total of 20 postlingually deafened patients with CIs. Main outcome measures: Primary outcome measure was sentence recognition assessed by a modified version of the Oldenburg Sentence Test filtered to the telephone bandwidth of 0.3-3.4 kHz. Additionally, pure tone thresholds, recognition of monosyllables and subjective hearing benefit were acquired at two separate visits before and after a home-based training period of 10-14 weeks. For training, patients received a CD with speech material, either unmodified for the unfiltered training group or filtered to the telephone bandwidth in the filtered group. Results: Patients in the unfiltered training group achieved an average sentence recognition score of 70.0%±13.6% (mean±SD) before and 73.6%±16.5% after training. Patients in the filtered training group achieved 70.7%±13.8% and 78.9%±7.0%, a statistically significant difference (P=.034, t10 =2.292; two-way RM ANOVA/Bonferroni). An increase in the recognition of monosyllabic words was noted in both groups. The subjective benefit was positive for filtered and negative for unfiltered training. Conclusions: Auditory training with specifically filtered speech material provided an improvement in sentence recognition on the telephone compared to training with unfiltered material.
The electrical field (E-field) of the biventricular (BV) stimulation is important for the success of cardiac resynchronization therapy (CRT) in patients with cardiac insufficiency and widened QRS complex.
The aim of the study was to model different pacing and ablation electrodes and to integrate them into a heart model for the static and dynamic simulation of BV stimulation and HF ablation in atrial fibrillation (AF).
The modeling and simulation was carried out using the electromagnetic simulation software CST. Five multipolar left ventricular (LV) electrodes, four bipolar right atrial (RA) electrodes, two right ventricular (RV) electrodes and one HF ablation catheter were modelled. A selection were integrated into the heart rhythm model (Schalk, Offenburg) for the electrical field simulation. The simulation of an AV node ablation at CRT was performed with RA, RV and LV electrodes and integrated ablation catheter with an 8 mm gold tip.
The BV stimulation were performed simultaneously at amplitude of 3 V at the LV electrode and 1 V at the RV electrode with a pulse width of 0.5 ms each. The far-field potential at the RA electrode tip was 32.86 mV and 185.97 mV at a distance of 1 mm from the RA electrode tip. AV node ablation was simulated with an applied power of 5 W at 420 kHz at the distal ablation electrode. The temperature at the catheter tip was 103.87 °C after 5 s ablation time and 37.61 °C at a distance of 2 mm inside the myocardium. After 15 s, the temperature was 118.42 °C and 42.13 °C.
Virtual heart and electrode models as well as the simulations of electrical fields and temperature profiles allow the static and dynamic simulation of atrial synchronous BV stimulation and HF ablation at AF and could be used to optimize the CRT and AF ablation.
Nachweise für die Stabilität von Regelkreisen, deren Stellgrößen an ihre Begrenzungen gelangen können und bei denen die Regler Integratoren oder andere dynamische Glieder sowie Anti-Windup-Maßnahmen enthalten, sind gewöhnlich sehr aufwändig zu führen. Bei PI-Zustandsreglern, die mittels der in [1] vorgestellten Methode in einem mehrstufigen Verfahren für Regelstrecken entworfen wurden, die bis auf die Stellgrößenbegrenzungen linear sind, lassen sich jedoch äußerst hilfreiche allgemeine Stabilitätsaussagen treffen, die den konkreten Stabilitätsnachweis für das Gesamtsystem– selbst unter Einbeziehung von Beobachtern – erheblich vereinfachen. Im vorliegenden Beitrag werden die diesbezüglichen, auf Steuerbarkeitsbetrachtungen beruhenden, Zusammenhänge für zeitdiskrete Regelkreise aufgezeigt sowie daraus exemplarisch mittels Ljapunow-Funktionen eine einfache Reglerformel für Zustandsregler abgeleitet, die auch im Begrenzungsfall stabil arbeiten. Ein Beispielaus der elektrischen Antriebstechnik illustriert die Anwendbarkeit der vorgestellten Methode.
The ability to detect a target signal masked by noise is improved in normal-hearing listeners when interaural phase differences (IPDs) between the ear signals exist either in the masker or in the signal. To improve binaural hearing in bilaterally implanted cochlear implant (BiCI) users, a coding strategy providing the best possible access to IPDs is highly desirable. Outcomes of a previous study (Zirn, Arndt et al. 2016) revealed that a subset of BiCI users showed improved IPD detection thresholds with the fine structure processing strategy FS4 compared to the constant rate strategy HDCIS using narrowband stimuli. In contrast, little differences between the coding strategies were found for broadband stimuli with regard to binaural speech intelligibility level differences (BILD) as an estimate of binaural unmasking. Compared to normalhearing listeners (7.5 ± 1.2 dB) BILD were small in BiCI users (around 0.5 dB with both coding strategies).
In the present work, we investigated the influence of binaural fitting parameters on BILD. In our cohort of BiCI users many were implanted with electrode arrays differing in length left versus right. Because this length difference typically corresponded to the distance of two electrode contacts the first modification of bilateral fitting was a tonotopic adjustment by deactivation of the most apical electrode contact on the side with the deeper inserted array (tonotopic approach).
The second modification was the isolation of the residual, most apical electrode contacts by deactivation of the basally adjacent electrode contact on each side (tonotopic sparse approach). Applying these modifications, BILD improved by up to 1.5 dB.
Das normalhörende auditorische System ist in der Lage, interaurale Zeit- bzw. Phasendifferenzen zur verbesserten Signaldetektion im Störgeräusch zu nutzen. Dieses Phänomen wird häufig als binaurale Entmaskierung bezeichnet und ist sowohl bei einfachen Signalen wie Sinustönen, als auch bei Sprachsignalen im Störgeräusch wirksam. Vorangegangene Studien haben gezeigt, dass binaurale Entmaskierung eingeschränkt auch bei bilateralen CI-Trägern beobachtbar ist (Zirn et al., 2016).
Aktuelle Ergebnisse zeigen, dass die binaurale Entmaskierung sensitiv gegenüber der bilateralen CI-Anpassung ist. So lässt sich der Effekt durch tonotopen Abgleich und Herausstellen eines apikalen Feinstrukturkanals modulieren. Steigerungen der binauralen Entmaskierung um bis zu 1,5 dB sind auf diese Weise gegenüber der konventionellen CI-Anpassung möglich. Allerdings variiert der Einfluss der CI-Anpassung interindividuell erheblich.
Die drei großen Hersteller von Cochlea-Implantat (CI)-Systemen ermöglichen es klinischen Audiologen, die Mikrofoneigenschaften der meisten CI-Sprachprozessoren zu prüfen. Dazu können bei diesen Sprachprozessoren Monitorkopfhörer angeschlossen und das/die Mikrofon(e) inklusive eines Teils der Signalvorverarbeitung abgehört werden. Präzise Angaben dazu, mit welchen Stimuli, bei welchem Pegel und nach welchem Kriterium diese Prüfung stattfinden soll, machen die CI-Hersteller nicht. Auf Basis dieser Prüfung soll der Audiologe dann über die Funktion der Mikrofone und damit darüber entscheiden, ob der betreffende Sprachprozessor an den Hersteller eingeschickt wird oder nicht.
Zur Objektivierung der CI-Sprachprozessor-Mikrofon-Prüfung haben wir eine Testbox entwickelt, mit der alle abhörbaren aktuellen CI-Sprachprozessoren der drei großen Hersteller geprüft werden können. Die Box wurde im 3D-Druck-Verfahren hergestellt. Der zu prüfende Sprachprozessor wird in die Messbox eingehängt und über einen darin verbauten Lautsprecher mit definierten Prüfsignalen (Sinustöne unterschiedlicher Frequenz) beschallt. Das Mikrofonsignal wird über das Kabel der Monitorkopfhörer herausgeführt und mit einer Shifting- and Scaling-Schaltung in einen Spannungsbereich transformiert, der für die AD-Wandlung mit einem Mikrokontroller (ATmega1280 verbaut auf einem Arduino Mega) geeignet ist. Derselbe Mikrokontroller übernimmt über einen eigens gebauten DA-Wandler die Ausgabe der Sinustöne über den Lautsprecher. Signalaufnahme und –wiedergabe erfolgen mit jeweils 38,5 kHz Samplingrate. Der für jede Frequenz über mehrere Perioden des Prüfsignals ermittelte Effektivwert wird mit dem Effektivwert, der mit einem neuwertigen Referenzprozessor für diese Frequenz gemessen wurde, verglichen. Die Messergebnisse werden graphisch auf einem Display ausgegeben.
Derzeit läuft eine erste Datenerhebung mit in der Klinik subjektiv auffällig gewordenen CI-Sprachprozessoren, die anschließend in der Messbox untersucht werden. So sollen realistische Schwellen für kritische Abweichungen von den Referenz-Effektivwerten ermittelt werden. Im weiteren Verlauf sollen dann Hit und False Alarm-Raten der subjektiven Prüfung bestimmt werden.
Since their dawning, space communications have been among the strongest driving applications for the development of error correcting codes. Indeed, space-to-Earth telemetry (TM) links have extensively exploited advanced coding schemes, from convolutional codes to Reed-Solomon codes (also in concatenated form) and, more recently, from turbo codes to low-density parity-check (LDPC) codes. The efficiency of these schemes has been extensively proved in several papers and reports. The situation is a bit different for Earth-to-space telecommand (TC) links. Space TCs must reliably convey control information as well as software patches from Earth control centers to scientific payload instruments and engineering equipment onboard (O/B) spacecraft. The success of a mission may be compromised because of an error corrupting a TC message: a detected error causing no execution or, even worse, an undetected error causing a wrong execution. This imposes strict constraints on the maximum acceptable detected and undetected error rates.
Finding clusters in high dimensional data is a challenging research problem. Subspace clustering algorithms aim to find clusters in all possible subspaces of the dataset where, a subspace is the subset of dimensions of the data. But exponential increase in the number of subspaces with the dimensionality of data renders most of the algorithms inefficient as well as ineffective. Moreover, these algorithms have ingrained data dependency in the clustering process, thus, parallelization becomes difficult and inefficient. SUBSCALE is a recent subspace clustering algorithm which is scalable with the dimensions and contains independent processing steps which can be exploited through parallelism. In this paper, we aim to leverage, firstly, the computational power of widely available multi-core processors to improve the runtime performance of the SUBSCALE algorithm. The experimental evaluation has shown linear speedup. Secondly, we are developing an approach using graphics processing units (GPUs) for fine-grained data parallelism to accelerate the computation further. First tests of the GPU implementation show very promising results.
eLetter zum Artikel "How hair can reveal a history" von Hanae Armitage & Nala Rogers, veröffentlicht in Science, Vol. 351, Issue 6278, Seite 1134 (doi.org/10.1126/science.351.6278.1134)
Musik und Neurophysiologie
(2017)
eLetter zum Artikel "Hybrid EEG/EOG-based brain/neural hand exoskeleton restores fully independent daily living activities after quadriplegia" von Surjo R. Soekadar et al., veröffentlicht in Science Robotics, Vol. 1, No. 1 (DOI: 10.1126/scirobotics.aag3296)
Nicht-invasives, nicht-ionisierendes funktionelles Neuroimaging mit räumlich und zeitlich hochauflösender Elektroenzephalographie oder Echtzeit-Naheinfrarotspektroskopie in Kombination mit modernen Robotorsystemen ist ein entscheidender Entwicklungsschritt auf dem Gebiet der Neuroprothetik und Brain-Machine-Interfaces. In der Medizintechnik an der Hochschule Offenburg wird hierzu geforscht.
The need to measure basic aerosol parameters has increased dramatically in the last decade. This is due mainly to their harmful effect on the environment and on public health. Legislation requires that particle emissions and ambient levels, workplace particle concentrations and exposure to them are measured to confirm that the defined limits are met and the public is not exposed to harmful concentrations of aerosols.