Refine
Document Type
Conference Type
- Konferenz-Poster (9) (remove)
Has Fulltext
- no (9)
Is part of the Bibliography
- yes (9)
Keywords
- 3D User Interface (1)
- Android (1)
- CST (1)
- Epilepsie (1)
- Erweitere Realität (1)
- Flashcards (1)
- HF-Ablation (1)
- Kalibrieren (1)
- Language learning (1)
- Optik (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (9) (remove)
Open Access
- Open Access (7)
- Bronze (3)
- Closed (1)
- Closed Access (1)
This work describes a camera-based method for the calibration of optical See-Through Glasses (STGs). A new calibration technique is introduced for calibrating every single display pixel of the STGs in order to overcome the disadvantages of a parametric model. A non-parametric model compared to the parametric one has the advantage that it can also map arbitrary distortions. The new generation of STGs using waveguide-based displays [5] will have higher arbitrary distortions due to the characteristics of their optics. First tests show better accuracies than in previous works. By using cameras which are placed behind the displays of the STGs, no error prone user interaction is necessary. It is shown that a high accuracy tracking device is not necessary for a good calibration. A camera mounted rigidly on the STGs is used to find the relations between the system components. Furthermore, this work elaborates on the necessity of a second subsequent calibration step which adapts the STGs to a specific user. First tests prove the theory that this subsequent step is necessary.
The ability to detect a target signal masked by noise is improved in normal-hearing listeners when interaural phase differences (IPDs) between the ear signals exist either in the masker or in the signal. To improve binaural hearing in bilaterally implanted cochlear implant (BiCI) users, a coding strategy providing the best possible access to IPDs is highly desirable. Outcomes of a previous study (Zirn, Arndt et al. 2016) revealed that a subset of BiCI users showed improved IPD detection thresholds with the fine structure processing strategy FS4 compared to the constant rate strategy HDCIS using narrowband stimuli. In contrast, little differences between the coding strategies were found for broadband stimuli with regard to binaural speech intelligibility level differences (BILD) as an estimate of binaural unmasking. Compared to normalhearing listeners (7.5 ± 1.2 dB) BILD were small in BiCI users (around 0.5 dB with both coding strategies).
In the present work, we investigated the influence of binaural fitting parameters on BILD. In our cohort of BiCI users many were implanted with electrode arrays differing in length left versus right. Because this length difference typically corresponded to the distance of two electrode contacts the first modification of bilateral fitting was a tonotopic adjustment by deactivation of the most apical electrode contact on the side with the deeper inserted array (tonotopic approach).
The second modification was the isolation of the residual, most apical electrode contacts by deactivation of the basally adjacent electrode contact on each side (tonotopic sparse approach). Applying these modifications, BILD improved by up to 1.5 dB.
Heart rhythm model and simulation of electrophysiological studies and high-frequency ablations
(2017)
Background: Target of the study was to create an accurate anatomic CAD heart rhythm model, and to show its usefulness for cardiac electrophysiological studies and high-frequency ablations. The method is more careful for the patients’ health and has the potential to replace clinical studies due to its high efficiency regarding time and costs.
Methods: All natural heart components of the new HRM were based on MRI records, which guaranteed electronic functionality. The software CST was used for the construction, while CST’s material library assured genuine tissue properties. It should be applicable to simulate different heart rhythm diseases as well as various diffusions of electromagnetic fields, caused by electrophysiological conduction, inside the heart tissue.
Results: It was achievable to simulate sinus rhythm and fourteen different heart rhythm disturbance with different atrial and ventricular conduction delays. The simulated biological excitation of healthy and sick HRM were plotted by simulated electrodes of four polar right atrial catheter, six polar His bundle catheter, ten polar coronary sinus catheter, four polar ablation catheter and eight polar transesophageal left cardiac catheter. Accordingly, six variables were rebuilt and inserted into the anatomic HRM in order to establish heart catheters for ECG monitoring and HF ablation. The HF ablation catheters made it possible to simulate various types of heart rhythm disturbance ablations with different HF ablation catheters and also showed a functional visualisation of tissue heating. The use of tetrahedral meshing HRM made it attainable to store the results faster accompanied by a higher degree of space saving. The smart meshing function reduced unnecessary high resolutions for coarse structures.
Conclusions: The new HRM for EPS simulation may be additional useful for simulation of heart rhythm disturbance, cardiac pacing, HF ablation and for locating and identification of complex fractioned signals within the atrium during atrial fibrillation HF ablation.
Flashcards are a well known and proven method to learn and memorise. Such a way of learning is perfectly suited for “learning on the way,” but carrying all the flashcards could be awkward. In this scenario, a mobile device (mobile phone) is an adequate solution. The new mobile device operating system Android from Google allows for writing multimedia-enriched applications.
Transcatheter aortiv valve implantation is a new safe strategy treatment for patients with symptomatic severe aortic stenosis and high operative risk. The aim of the study was to compare the pre-and post- muiscatheter aortiv valve implantation procedures to determine the atrioventricuktr conduction time as a potential predictor of permanent pacemaker therapy requirement after transcatheter aortiv valve implantation. The transcatheter aortiv valve implantation patients were divided into groups without pacemaker and with dual or single chamber pacemEtker with diffent atrioventrieular conduction time disturbance before and after transcatheter aortiv valve implantation. In heart failure, patients without permanent pacemaker therapy after transcatheter aortiv valve implantation, atrioventricular conduction time was prolonged after transcatheter aortiv valve implantation. In patients with permanent dual chamber pacemaker therapy after transcatheter aortiv valve implantation, atrioventricular conduction time was normalised with dual chaniber atrioventrieuku pacing mode. Atrioventricular conduction time may be a useful parameter to evaluate the risk of post-procedural atrioventricular conduction block and permanent pacemaker therapy in transcatheter north, valve implantation patients.
A platform of an electronic capsule is being developed for multi-task medical assistant application. It includes a near field telemetry unit for bidirectional communication system of 115 KHz low carrier frequency for inductive data transmission suited for human body energy transfer. The system triggers an actuator for drug delivery in various time and release forms via wireless external control, it has the ability to record temperature, measure pH of the body (additional sensors), and retrieve data to the outside. It consists of a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA. A final layout of the complete chip design is still under progress.
The idea of this game is to use a flashcard system to create a short story in a foreign language. The story is developed by a group of people by exchanging sentences via a flashcard system. This way, people can learn from each other without fear of making mistakes because the group members are anonymous.