Im Projekt MOBCOM wird ein neues Verfahren zur Zustandsüberwachung von elektrischen Betriebsmitteln in Niederspannungsnetzen und Anlagen entwickelt. Mittels PLC (power line communication) Technologie werden hochfrequente transiente Vorgänge auf dem Stromkanal und dessen Übertragungseigenschaften erfasst und bewertet. Durch Ableiten bestimmter Parameter soll zustandsbedingte Wartung vorhergesagt und so der Ausfall von Betriebsmittel vermieden werden.
In this paper we report on further success of our work to develop a multi-method energy optimization which works with a digital twin concept. The twin concept serves to replicate production processes of different kinds of production companies, including complex energy systems and test market interactions to then use them for model predictive optimizing. The presented work finally reports about the performed flexibility assessment leading to a flexibility audit with a list of measures and the impact of energy optimizations made related to interactions with the local power grid i.e., the exchange node of the low voltage distribution grid. The analysis and continuous exploration of flexibilities as well as the exchange with energy markets require a “guide” leading to continuous optimization with a further tool like the Flexibility Survey and Control Panel helping decision-making processes on the day-ahead horizon for real production plants or the investment planning to improve machinery, staff schedules and production
infrastructure.
We describe a prototype for power line communi- cation for grid monitoring. The PLC receiver is used to gain information about the PLC channel and the current state of the power grid. The PLC receiver uses the communication signal to obtain an accurate estimate of the current channel and provides information which can be used as a basis for further processing with the aim to detect partial discharges and other anomalies in the grid. This monitoring of the power grid takes advantage of existing PLC infrastructure and uses the data signals, which are transmitted anyway to obtain a real-time measurement of the channel transfer function and the received noise signal. Since this signal is sampled at a high sampling rate compared to simpler measurement sensors, it contains valuable information about possible degradations in the grid which need to be addressed. While channel measurements are based on a received PLC signal, information about partial discharges or other sources of interference can be gathered by a PLC receiver in the absence of a transmit signal. A prototype based on Software Defined Radio has been developed, which implements the simultaneous communication and sensing for a power grid.