Refine
Year of publication
Document Type
- Article (reviewed) (30) (remove)
Has Fulltext
- no (30) (remove)
Is part of the Bibliography
- yes (30) (remove)
Keywords
- Gehirn (2)
- Kommunikation (2)
- Nuklearmedizin (2)
- Synchronisierung (2)
- cardiac resynchronization therapy (2)
- 3D modeling (1)
- 3d Heart Simulation (1)
- Bildgebung (1)
- CRT (1)
- CST (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (30) (remove)
Open Access
- Open Access (30) (remove)
Seit den ersten Projekten der 90er Jahre arbeiten Hochschulen daran, geeignete Servicestrukturen für E-Learning zu etablieren, die die erforderliche technische, didaktische und organisatorische Unterstützung hochschulweit zur Verfügung stellen. Ging es zunächst darum, Services überhaupt dauerhaft zu sichern, steht heute die Frage des „wie“ im Vordergrund. Dabei wird am Bereich E-Learning ein eigentlich viel allgemeineres Problem deutlich: Die bisher überwiegende Organisation der Hochschule nach funktionellen Einheiten stößt an ihre Grenzen. Wir schlagen eine stärker prozessorientierte Sichtweise vor, analog zu Entwicklungen bei der Organisation von Unternehmen.
A new yield function for lamellar gray cast iron materials is proposed. The new model is able to describe the results of recently performed microstructure-based finite-element computations that resolve the three dimensional yield surface of three different gray cast irons. The yield function requires only the yield stress in tension and compression of the respective material as model parameters. Furthermore, the algorithmic formulation of the new model is assessed for numerical robustness and efficiency.
The automatic classification of the modulation format of a detected signal is the intermediate step between signal detection and demodulation. If neither the transmitted data nor other signal parameters such as the frequency offset, phase offset and timing information are known, then automatic modulation classification (AMC) is a challenging task in radio monitoring systems. The approach of clustering algorithms is a new trend in AMC for digital modulations. A novel algorithm called `highest constellation pattern matching' is introduced to identify quadrature amplitude modulation and phase shift keying signals. The obtained simulation and measurement results outperform the existing algorithms for AMC based on clustering. Finally, it is shown that the proposed algorithm works in a real monitoring environment.
The study from Mehrazin et al. in HJNM 2011; 14(3): 243-50 on the neuropsychology, morphological computerized tomography (CT) and functional neuroimaging with 99mTc-labelled ethylene cystein-ate dimer single-photon emission tomography (SPET) in mild trau-matic brain injury (MTBI) is an interesting new approach to a disease condition which is often neglected or denied. Related to the above, we may note that the French composer Maurice Ravel (1875-1937), who suffered from Pick ́s disease with primary progressive apha-sia, had a taxi accident in 1932, with a mild concussion, perhaps an MTBI. Apart from the dysphasia and beginning apraxia, which Rav-el had already 5 years prior to the taxi accident, these symptoms exacerbated-the dysphasia became a progressive aphasia-and he developed additional severe deficits in concentration and atten-tion after the accident. It has also been suspected that this accident may have triggered Ravel ́s agraphia the unability to write down any new composition beyond the date of the taxi accident, a condi-tion that Ravel himself described as unacceptable and which made him feel very sad as his mind was full of ideas. Due to the deterio-ration of his health, which can also be seen in his appearance on late photographs, Ravel consulted the famous neurosurgeon Prof. Clovis Vincent. Vincent, who suspected a hydrocephalus, opened Ravel ́s skull on December 19, 1937, showing a normal brain. Soon after surgery Ravel died. In conclusion, a SPET/CT approach com-bined with a brain perfusion analysis using statistical parametric mapping might be the recommendable approach today for mild traumatic brain injury.
The suffix-free-prefix-free hash function construction and its indifferentiability security analysis
(2012)
In this paper, we observe that in the seminal work on indifferentiability analysis of iterated hash functions by Coron et al. and in subsequent works, the initial value (IV) of hash functions is fixed. In addition, these indifferentiability results do not depend on the Merkle–Damgård (MD) strengthening in the padding functionality of the hash functions. We propose a generic n-bit-iterated hash function framework based on an n-bit compression function called suffix-free-prefix-free (SFPF) that works for arbitrary IVs and does not possess MD strengthening. We formally prove that SFPF is indifferentiable from a random oracle (RO) when the compression function is viewed as a fixed input-length random oracle (FIL-RO). We show that some hash function constructions proposed in the literature fit in the SFPF framework while others that do not fit in this framework are not indifferentiable from a RO. We also show that the SFPF hash function framework with the provision of MD strengthening generalizes any n-bit-iterated hash function based on an n-bit compression function and with an n-bit chaining value that is proven indifferentiable from a RO.
A survey in 2000 revealed that only about 30% of the prescriptions in the European pediatric population were on the basis of evidence-based medicine (EbM). Less for radiopharmaceuticals and principally for diagnostics, radiologists throughout Europe are referred to the pediatric guidelines of the European Association of Nuclear Medicine (EANM), as none of the frequently used tracers have been evaluated in clinical trials in the different pediatric subgroups. Following a resolution to address the lack of EbM in children, the European Commission published the Pediatric Regulation EC 1901/2006 and its amendment EC 1902/2006, effective from 2007. This regulation foresees the development of evidence-based medicine in the pediatric population. This is effected through a set of principles like the mandatory pediatric investigation plan (PIP) to be included with the market authorization application (MAA), and the pediatric use market authorization (PUMA) for off-patent pharmaceuticals, and to a very small part radiopharmaceuticals with funding possibilities for pediatric-specific research through the 7th Framework Programme (7FP) of the European Union.
Routine nuclear cardiology examinations indicate heart rate, cardiac rhythm, the height of cardiac pulse and respiration rhythm. It would be of interest to study whether these data, especially if the same tests are repeated, can indicate patients’ well being in the future and perhaps patients’ life span, other factors being equal. Related old theories and suggestions are mentioned. Furthermore, some drugs like I-f channel antagonists and stress tests testing cardiac reserves could support such a study.
The Humboldt digital library (HDL) represents an innovative system to access the works and legacy of Alexander von Humboldt in a digital form on the Internet (www.avhumboldt.net). It contributes to the key question about how to present interconnected data in an appropriate form using information technologies. The HDL has been created as a dynamic digital library with the capability of connecting multilingual and multimedia data from diverse online archives. Humboldt’s volumes have become available, but beyond that any relevant information related to the observations of Humboldt, even outside the works can become immediately accessible. This makes it possible to recognize natural changes and compare Humboldt’s descriptions with recent situations. The technology we have developed addresses the issues of sustainability and makes it possible to detect changes in the environment since the time of Humboldt’s observations.
There are some existing Java benchmarks, application benchmarks as well as micro benchmarks or mixture both of them,such as: Java Grande, Spec98, CaffeMark, HBech, etc. But none of them deal with behaviors of multi tasks operating systems. As a result, the achieved outputs are not satisfied for performance evaluation engineers. Behaviors of multi tasks operating systems are based on a schedule management which is employed in these systems. Different processes can have different priority to share the same resources. The time is measured by estimating from applications started to it is finished does not reflect the real time value which the system need for running those programs. New approach to this problem should be done. Having said that, in this paper we present a new Java benchmark, named FHOJ benchmark, which directly deals with multi tasks behaviors of a system. Our study shows that in some cases, results from FHOJ benchmark are far more reliable in comparison with some existing Java benchmarks.
Lattice vibrations and electronic transitions in the rare-earth metals: Praseodymium under pressure
(2004)
Praseodymium was investigated by Raman spectroscopy under pressure. A negative pressure shift of the E2g mode is observed in the dhcp phase, which indicates that the initial structural sequence hcp→Sm−type→dhcp→fcc as a whole in the regular lanthanides is associated with a softening of this mode. The pressure response of the phonon modes, observed in the monoclinic and α-uranium phases, where 4f bonding becomes important, is characteristic for anisotropic bonding properties.
Formal verification (FV) is considered by many to be complicated and to require considerable mathematical knowledge for successful application. We have developed a methodology in which we have added formal verification to the verification process without requiring any knowledge of formal verification languages. We use only finite-state machine notation, which is familiar and intuitive to designers. Another problem associated with formal verification is state-space explosion. If that occurs, no result is returned; our method switches to random simulation after one hour without results, and no effort is lost. We have compared FV against random simulation with respect to development time, and our results indicate that FV is at least as fast as random simulation. FV is superior in terms of verification quality, however, because it is exhaustive.
A laser-operated, angle-tunable transducer was employed to excite selectively elastic waves guided along the apex of a solid wedge. The propagation of wedge waves at anisotropic monocrystalline silicon edges with different symmetry properties was studied by optical detection. The reduced symmetry in crystals, as compared to isotropic media, causes a number of new features, such as the existence of supersonic leaky wedge waves, tilted spatial pulse profiles, and other peculiarities of their localization. Experimental and theoretical results are presented for three different types of symmetry configurations: the wedge symmetric about its midplane, the wedge symmetric about the plane normal to its apex line, and the wedge symmetric about one of its faces. The experiments include accurate measurements of the phase velocity and the wave field distribution, providing information on localization and coupling of wedge waves with other waves. Theoretically, the wedge waves were treated by the Laguerre function method, extended to modes that are not localized at the tip of the wedge. This approach allowed an accurate description of the observed localized and leaky wedge waves in anisotropic wedges.
Die Hersteller von Cochlea-Implantat (CI)-Systemen sehen für klinische Audiologen die Möglichkeit vor, die Mikrofonleistung der meisten aktuellen CI-Sprachprozessoren mittels anschließbarer Monitorkopfhörer zu prüfen. Nähere Angaben dazu, nach welchem Prozedere diese Prüfung stattfinden soll, z. B. welche Stimuli mit welchen Pegeln verwendet werden sollen, sind nach Wissen der Autoren seitens der CI-Hersteller nicht verfügbar. Auf der Basis dieser subjektiven Prüfung entscheidet dann der Audiologe, ob der betreffende Sprachprozessor an den Hersteller eingeschickt wird oder nicht. Wir haben eine Messbox entwickelt, mit der die Mikrofonleistung aller abhörbaren CI-Sprachprozessoren der Hersteller Advanced Bionics, Cochlear und MED-EL objektiv geprüft werden kann. Die Box wurde im 3-D-Druckverfahren hergestellt. Der zu prüfende Sprachprozessor wird in die Messbox eingehängt und über einen verbauten Lautsprecher mit definierten Prüfsignalen (Sinustönen unterschiedlicher Frequenz) beschallt. Das Signal des Mikronfons bzw. der Mikrofone wird über das in der Audio-/Abhörbuchse des Prozessors eingesteckte Kabel der Monitorkopfhörer herausgeführt und mit einer Shifting and Scaling-Schaltung in einen Spannungsbereich transformiert, der für die A/D-Wandlung mit einem Mikrokontroller (ATmega1280 verbaut auf einem Arduino Mega) geeignet ist. Derselbe Mikrokontroller übernimmt über einen eigens gebauten D/AWandler die Ausgabe der Prüfsignale über den Lautsprecher. Signalaufnahme und –wiedergabe erfolgt jeweils mit einer Samplingrate von 38,5 kHz. Der frequenzspezifische Effektivwert des abgegriffenen Mikrofonsignals wird mit einem Referenzwert verglichen. Die (frequenzspezifischen) Referenzwerte wurden mit einem neuwertigen Sprachprozessor gleichen Typs ermittelt und im Speicher des Mikrokontrollers abgelegt. Das Ergebnis wird nach Abschluss der Messung grafisch auf einem Touchscreen ausgegeben. Derzeit läuft eine erste Datenerhebung mit in der Klinik subjektiv auffällig gewordenen CI-Sprachprozessoren, die anschließend in der Messbox untersucht werden. Längerfristiges Ziel ist es, die hit und false alarm Raten der subjektiven Prüfung zu ermitteln.
Cardiac contractility modulation (CCM) is a device-based therapy for the treatment of systolic left ventricular chronic heart failure. Unlike other device-based therapies for heart failure, CCM delivers non-excitatory pacing signals to the myocardium. This leads to an extension of the action potential and to an improved contractility of the heart. The modeling and simulation was done with the electromagnetic simulation software CST. Three CCM electrodes were inserted into the Offenburg heart rhythm model and subsequently simulated the electric field propagation in CCM therapy.
In addition, simulations of CCM have been performed with electrodes from other device-based therapies, such as cardiac resynchronization therapy (CRT) and implantable cardioverter / defibrillator (ICD) therapy. At the same distance to the simulation electrode, the electric field is slightly stronger in CCM therapy than in CCM therapy with additionally implanted CRT or ICD electrodes. In addition, there is a change in the electric field propagation at the electrodes of the CRT and the shock electrode of the ICD.
By simulating several different therapy procedures on the heart, it is possible to check how they affect their behavior during normal operation. CCM heart rhythm model simulation allows the evaluation the individual electrical pacing and sensing field during CCM.
Abstract: Electric field of biventricular (BV) pacing, left ventricular (LV) electrode position and electrical interventricular desynchronization are important parameters for successful cardiac resynchronization therapy (CRT) in patients with heart failure, sinus rhythm and reduced LV ejection fraction. The aim of the study was to evaluate electric pacing field of transesophageal left atrial (LA) pacing and BV pacing with 3D heart rhythm simulation. Bipolar right atrial (RA), right ventricular (RV), LV electrodes and multipolar hemispherical esophageal LA electrodes were modeled with CST (Computer Simulation Technology, Darmstadt). Electric pacing field were simulated with bipolar RA and RV pacing with Solid S (Biotronik) electrode, bipolar LV pacing with Attain 4194 (Medtronic) electrode and bipolar LA pacing with TO8 (Osypka) esophageal electrode. 3D heart rhythm model with esophagus allowed electric pacing field simulation of 4-chamber pacing with bipolar intracardiac RA, RV, LV pacing and bipolar transesophageal LA pacing. The pacing amplitudes were 3V RA pacing amplitude, 50V LA pacing amplitude, 1.5V RV pacing amplitude and 3V LV pacing amplitude with 0.5ms pacing pulse duration. The atrioventricular delay between RA pacing and BV pacing was 140ms atrioventricular pacing delay and simultaneous RV and LV pacing. Electric pacing fields were simulated during the different pacing modes AAI, VVI, DDD and DDD0V. The intracardiac far-field pacing potentials were evaluated with intracardiac electrodes and a distance of 1mm from the electrodes with RA electrode 1.104V, RV electrode 0.703V and LV electrode 1.32V. The transesophageal far-field pacing potential was evaluated with transesophageal electrode and a distance of 10mm from the elelctrode with LA electrode 6.076V. Heart rhythm model simulation with esophagus allows evaluation of electric pacing fields in AAI, VVI, DDD, DDD0V and DDD0D pacing modes. Electric pacing field of RA, RV and LV pacing in combination with LA pacing may additional useful pacing mode in CRT non-responders.
Pulmonary vein isolation (PVI) is a common therapy in atrial fibrillation (AF). The cryoballoon was invented to isolate the pulmonary vein in one step and in a shorter time than a point-by-point radiofrequency (RF) ablation. The aim of the study was to model two cryoballoon catheters, one RF catheter and to integrate them into a heart rhythm model for the static and dynamic simulation of PVI by cryoablation and RF ablation in AF. The modeling and simulation were carried out using the electromagnetic and thermal simulation software CST (CST, Darmstadt). Two cryoballons and one RF ablation catheter were modeled based on the technical manuals of the manufacturers Medtronic and Osypka. The PVI especially the isolation of the left inferior pulmonary vein using a cryoballoon catheter was performed with a -50 °C heatsource and an exponential signal. The temperature at the balloon surface was -50 °C after 20 s ablation time, -24 °C from the balloon 0,5 mm in the myocardium, at a distance of 1 mm -3 °C, at 2 mm 18 °C and at a distance of 3mm 29 °C. PVI with RF energy was simulated with an applied power of 5 W at 420 kHz at the distal 8 mm ablation electrode. The temperature at the tip electrode was 110 °C after 15 s ablation time, 75 °C from the balloon at 0,5 mm in the myocardium, at a distance of 1 mm 58 °C, at 2 mm 45 °C and at a distance of 3 mm 38 °C. Virtual heart rhythm and catheter models as well as the simulation of the temperature allow the simulation of PVI in AF by cryo ablation and RF ablation. The 3D simulation of the temperature profile may be used to optimize RF and cryo ablation.
The high frequency (HF) catheter ablation is the gold standard for the therapy of many cardiac tachyarrhythmias, such as atrioventricular node re-entry tachycardia (AVNRT), atrioventricular re-entry tachycardia (AVRT) or atrial flutter (AFL). The aim of the study was to simulate the HF ablation of AVNRT, AVRT, AFL and its heat propagation in reference to the supplied power with different electrode material and electrode size. The modeling and simulation were performed with the thermal and electromagnetic simulation software CST® (Computer Simulation Technology, Darmstadt). The modeling and simulation were carried out using ablation catheters with 4 mm tip electrode and 8 mm tip electrode with different electrode materials. Both electrode types were made of platinum and gold respectively. For the measurement of the heat propagation in the heart tissue, the catheters were integrated in the Offenburg heart rhythm model. The HF ablation procedures were performed with the 4 mm platinum tip electrode, with an application duration of 45 seconds and a power output of 40 watts. The HF ablation of the atrioventricular node slow pathway produced a maximum temperature of 66.33 °C. The Kent bundle HF ablation in the left atrium achieved a maximum temperature of 67.14 °C. The HF ablation of the right atrial isthmus resulted 65.96 °C. The 8 mm distal platinum tip electrode and a power output of 60 watts reached 72.85 °C. The 8 mm distal gold tip electrode and a power output of 60 watt reached 64.66 °C, due to the improved thermal conductivity of gold. Virtual heart and ablation electrode models allow the static and dynamic simulation of HF ablation with different electrode material and electrode size. The 3D simulation of the temperature profile may be used to optimize the AVNRT, AVRT and AFL HF ablation.
The increasing number of transistors being clocked at high frequencies of modern microprocessors lead to an increasing power consumption, which calls for an active dynamic thermal management. In a research project a system environment has been developed, which includes thermal modeling of the microprocessor in the board system, a software environment to control the characteristics of the system’s timing behavior, and a modified Linux scheduler, which is enhanced with a prediction controller. Measurement results are shown for this development for a Freescale i.MX6Q quad-core microprocessor.