Nickel cobalt aluminum oxide (NCA) based lithium-ion battery electrodes exhibit a distinct asymmetry in discharge/charge behavior towards high bulk stoichiometry (low state of charge). We show that basic electrochemical relationships, that is, the Nernst equation and the Butler-Volmer equation, are able to reproduce this behavior when a two-step reaction mechanism is assumed. The two-step mechanism consists of (1) lithium-ion adsorption from the electrolyte onto the active material particle surface under electron transfer, and (2) intercalation of surface-adsorbed lithium atoms into the bulk material. The asymmetry of experimental half-cell data of an NCA electrode cycled at 0.1 C-rate can be quantitatively reproduced with this simple model. The model parameters show two alternative solutions, predicting either a saturated (highly-covered) or a depleted surface for high bulk lithiation.
The uncertain and time-variant nature of renewable energy results in the need to deal with peaks in the production of energy. One approach is to achieve a load shift and thereby help balancing the grid by using thermally Activated Building Systems (TABS). Control systems currently in place do not exploit the full potential of TABS. This paper reviews how Model Predictive Control can possibly reduce the fluctuations of the demand and supply of (renewable) energy as it enables the TABS to react to the dynamics of weather and its impact on the grid at any time.
Battery degradation is a complex physicochemical process that strongly depends on operating conditions and environment. We present a model-based analysis of lithium-ion battery degradation in smart microgrids, in particular, a single-family house and an office tract with photovoltaics generator. We use a multi-scale multi-physics model of a graphite/lithium iron phosphate (LiFePO4, LFP) cell including SEI formation as ageing mechanism. The cell-level model is dynamically coupled to a system-level model consisting of photovoltaics, inverter, power consumption profiles, grid interaction, and energy management system, fed with historic weather data. The behavior of the cell in terms of degradation propensity, performance, state of charge and other internal states is predicted over an annual operation cycle. As result, we have identified a peak in degradation rate during the battery charging process, caused by charging overpotentials. Ageing strongly depends on the load situation, where the predicted annual capacity fade is 1.9 % for the single-family house and only 1.3 % for the office tract.
There is a growing trend for the use of thermo-active building systems (TABS) for the heating and cooling of buildings, because these systems are known to be very economical and efficient. However, their control is complicated due to the large thermal inertia, and their parameterization is time-consuming. With conventional TABS-control strategies, the required thermal comfort in buildings can often not be maintained, particularly if the internal heat sources are suddenly changed. This paper shows measurement results and evaluations of the operation of a novel adaptive and predictive calculation method, based on a multiple linear regression (AMLR) for the control of TABS. The measurement results are compared with the standard TABS strategy. The results show that the electrical pump energy could be reduced by more than 86%. Including the weather adjustment, it could be demonstrated that thermal energy savings of over 41% could be reached. In addition, the thermal comfort could be improved due to the possibility to specify mean room set-point temperatures. With the AMLR, comfort category I of the comfort norms ISO 7730 and DIN EN 15251 are observed in about 95% of occasions. With the standard TABS strategy, only about 24% are within category I.
Adaptive predictive control of thermo-active building systems (TABS) based on a multiple regression algorithm: First practical test. Available from: https://www.researchgate.net/publication/305903009_Adaptive_predictive_control_of_thermo-active_building_systems_TABS_based_on_a_multiple_regression_algorithm_First_practical_test [accessed Jul 7, 2017].
The humanoid Sweaty was the finalist in this year’s robocup soccer championship(adult size). For the optimization of the gait and the stability, data concerning forces and torques in the ankle joints would be helpful. In the following paper the development of a six-axis force and torque sensor for the humanoid robot Sweaty is described. Since commercial sensors do not meet the demands for the sensors in Sweatys ankle joints, a new sensor was developed. As a measuring devices we used strain gauges and custom electronics based on an acam PS09. The geometry was analyzed with the FEM program ANSYS to get optimal dimensions for the measuring beams. In addition ANSYS was used to optimize the position for the strain gauges on the beam.
Proton Exchange Membrane Fuel Cells (PEMFC) are energy efficient and environmentally friendly alternatives to conventional energy conversion systems in many yet emerging applications. In order to enable prediction of their performance and durability, it is crucial to gain a deeper understanding of the relevant operation phenomena, e.g., electrochemistry, transport phenomena, thermodynamics as well as the mechanisms leading to the degradation of cell components. Achieving the goal of providing predictive tools to model PEMFC performance, durability and degradation is a challenging task requiring the development of detailed and realistic models reaching from the atomic/molecular scale over the meso scale of structures and materials up to components, stack and system level. In addition an appropriate way of coupling the different scales is required.
This review provides a comprehensive overview of the state of the art in modeling of PEMFC, covering all relevant scales from atomistic up to system level as well as the coupling between these scales. Furthermore, it focuses on the modeling of PEMFC degradation mechanisms and on the coupling between performance and degradation models.
Electrochemical impedance spectroscopy (EIS) is a widely-used diagnostic technique to characterize electrochemical processes. It is based on the dynamic analysis of two electrical observables, that is, current and voltage. Electrochemical cells with gaseous reactants or products (e.g., fuel cells, metal/air cells, electrolyzers) offer an additional observable, that is, the gas pressure. The dynamic coupling of current and/or voltage with gas pressure gives rise to a number of additional impedance definitions, for which we use the term electrochemical pressure impedance. It also gives rise to different experimental probing approaches. In this article we present a model-based study of electrochemical pressure impedance spectroscopy (EPIS). Possible quantifications and realizations of EPIS are discussed. The study of generic cell geometries consisting of gas reservoir, diffusion layer(s) and electrochemically active layer(s) reveals distinct spiral-shaped features in the Nyquist plot. Using the example of a sodium/oxygen (Na/O2) cell, the dynamic spatiotemporal behavior of the state variables is quantified and interpreted. Results are compared to first experimental EPIS measurements by Hartmann et al. [J. Phys. Chem. C118, 1461, 2014]. A sensitivity analysis highlights the properties of EPIS with respect to geometric, transport, and kinetic parameters. We demonstrate that EPIS is sensitive to transport parameters that are not well-accessible with standard EIS.
Lithium–oxygen cells with nonaqueous electrolyte show high overpotentials during charge, indicating asymmetric charge/discharge reaction mechanisms. We present a kinetic modeling and simulation study of the lithium–oxygen cell cycling behavior. The model includes a multistep reaction mechanism of the cell reaction (2Li + O2 ⇄ Li2O2) forming lithium peroxide by precipitation, coupled to a 1D porous-electrode transport model. We apply the model to study the asymmetric discharge/charge characteristics and analyze the influence of a redox mediator dissolved homogeneously in the liquid electrolyte. Model predictions are compared to experimental galvanostatic cycling data of cells without and with 2,2,6,6-tetramethylpiperidinyloxyl (TEMPO) as redox mediator. The predicted discharge behavior shows good agreement with the experimental results. A spatiotemporal analysis of species concentrations reveals inhomogeneous distributions of dissolved oxygen and reaction products within the cathode during discharge. The experimentally observed charge overpotentials as well as their reduction by using a redox mediator can be qualitatively reproduced with a partially irreversible reaction mechanism. However, the proposed models fail to reproduce the particular shape of the experimental charge curve with continuously increasing charge overpotential, which implies that part of the reaction mechanism is still open for investigation in future work.
n this work a mathematical model for describing the performance of lithium-ion battery electrodes consisting of porous active material particles is presented. The model represents an extension of the Newman-type model, accounting for the agglomerate structure of the active material particles, here Li(Ni1/3Co1/3Mn1/3)O2 (NCM) and Li(Ni1/3Co1/3Al1/3)O2 (NCA). To this goal, an additional pore space is introduced on the active material level. The space is filled with electrolyte and a charge-transfer reaction takes place at the liquid-solid interface within the porous active material particles. Volume-averaging techniques are used to derive the model equations. A local Thiele modulus is defined and provides an insight into the potentially limiting factors on the active material level. The introduction of a liquid-phase ion transport within the active material reduces the overall transport losses, while the additional active surface area within the agglomerate lowers the charge-transfer resistance. As a consequence, calculated discharge capacities are higher for particles modeled as agglomerates. This finding is more pronounced in the case of high C-rates
Optimal microgrid scheduling with peak load reduction involving an electrolyzer and flexible loads
(2016)
This work consists of a multi-objective mixed-integer linear programming model for defining optimized schedules of components in a grid-connected microgrid. The microgrid includes a hydrogen energy system consisting of an alkaline electrolyzer, hydrogen cylinder bundles and a fuel cell for energy storage. Local generation is provided from photovoltaic panels, and the load is given by a fixed load profile combined with a flexible electrical load, which is a battery electric vehicle. The electrolyzer has ramp-up constraints which are modeled explicitly. The objective function includes, besides operational costs and an environmental indicator, a representation of peak power costs, thus leading to an overall peak load reduction under optimized operation. The model is used both for controlling a microgrid in a field trial set-up deployed in South-West Germany and for simulating the microgrid operation for defined period, thus allowing for economic system evaluation. Results from defined sample runs show that the energy storage is primarily used for trimming the peak of electricity drawn from the public grid and is not solely operated with excess power. The flexible demand operation also helps keeping the peak at its possible minimum.
Passive solar elements for both direct and indirect gains, are systems used to maintain a comfortable living environment while saving energy, especially in the building energy retrofit and adaptation process. Sunspaces, thermal mass and glazing area and orientation have been often used in the past to guarantee adequate indoor conditions when mechanical devices were not available. After a period of neglect, nowadays they are again considered as appropriate systems to help face environmental issues in the building sector, and both international and national legislation takes into consideration the possibility of including them in the building planning tools, also providing economic incentives. Their proper design needs dynamic simulation, often difficult to perform and time consuming. Moreover, results generally suffer from several uncertainties, so quasi steady-state procedures are often used in everyday practice with good results, but some corrections are still needed. In this paper, a comparative analysis of different solutions for the construction of verandas in an existing building is presented, following the procedure provided by the slightly modified and improved Standard EN ISO 13790:2008. Advantages and disadvantages of different configurations considering thermal insulation, windows typology and mechanical ventilation systems are discussed and a general intervention strategy is proposed. The aim is to highlight the possibility of using sunspaces in order to increase the efficiency of the existing building stock, considering ease of construction and economic viability.
Energy Performance of Verandas in the Building Retrofit Process (PDF Download Available). Available from: https://www.researchgate.net/publication/303093420_Energy_Performance_of_Verandas_in_the_Building_Retrofit_Process [accessed Jul 5, 2017].