Refine
Year of publication
Document Type
- Article (reviewed) (257)
- Conference Proceeding (196)
- Article (unreviewed) (35)
- Contribution to a Periodical (31)
- Part of a Book (22)
- Patent (10)
- Book (5)
- Doctoral Thesis (3)
- Working Paper (2)
- Periodical Part (1)
Conference Type
- Konferenzartikel (130)
- Konferenz-Abstract (43)
- Sonstiges (11)
- Konferenz-Poster (9)
- Konferenzband (5)
Language
- English (562) (remove)
Is part of the Bibliography
- yes (562) (remove)
Keywords
- Dünnschichtchromatographie (26)
- Plastizität (12)
- TRIZ (10)
- injury (10)
- Adsorption (9)
- Metallorganisches Netzwerk (9)
- running (9)
- Materialermüdung (8)
- RoboCup (8)
- biomechanics (8)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (562) (remove)
Open Access
- Open Access (268)
- Closed Access (167)
- Closed (63)
- Bronze (44)
- Gold (32)
- Hybrid (32)
- Diamond (19)
- Grün (5)
In a randomized controlled cross-over study ten male runners (26.7 ± 4.9 years; recent 5-km time: 18:37 ± 1:07 min:s) performed an incremental treadmill test (ITT) and a 3-km time trial (3-km TT) on a treadmill while wearing either carbon fiber insoles with downwards curvature or insoles made of butyl rubber (control condition) in light road racing shoes (Saucony Fastwitch 9). Oxygen uptake, respiratory exchange ratio, heart rate, blood lactate concentration, stride frequency, stride length and time to exhaustion were assessed during ITT. After ITT, all runners rated their perceived exertion, perceived shoe comfort and perceived shoe performance. Running time, heart rate, blood lactate levels, stride frequency and stride length were recorded during, and shoe comfort and shoe performance after, the 3-km TT. All parameters obtained during or after the ITT did not differ between the two conditions [range: p = 0.188 to 0.948 (alpha value: 0.05); Cohen's d = 0.021 to 0.479] despite the rating of shoe comfort showing better scores for the control insoles (p = 0.001; d = −1.646). All parameters during and after the 3-km TT showed no differences (p = 0.200 to 1.000; d = 0.000 to 0.501) between both conditions except for shoe comfort showing better scores for control insoles (p = 0.017; d = −0.919). Running with carbon fiber insoles with downwards curvature did not change running performance or any submaximal or maximal physiological or biomechanical parameter and perceived exertion compared to control condition. Shoe comfort is impaired while running with carbon fiber insoles. Wearing carbon fiber insoles with downwards curvature during treadmill running is not beneficial when compared to running with control insoles.
Batteries typically consist of multiple individual cells connected in series. Here we demonstrate single-cell state of charge (SOC) and state of health (SOH) diagnosis in a 24 V class lithium-ion battery. To this goal, we introduce and apply a novel, highly efficient algorithm based on a voltage-controlled model (VCM). The battery, consisting of eight single cells, is cycled over a duration of five months under a simple cycling protocol between 20 % and 100 % SOC. The cell-to-cell standard deviations obtained with the novel algorithm were 1.25 SOC-% and 1.07 SOH-% at beginning of cycling. A cell-averaged capacity loss of 9.9 % after five months cycling was observed. While the accuracy of single-cell SOC estimation was limited (probably owed to the flat voltage characteristics of the lithium iron phosphate, LFP, chemistry investigated here), single-cell SOH estimation showed a high accuracy (2.09 SOH-% mean absolute error compared to laboratory reference tests). Because the algorithm does not require observers, filters, or neural networks, it is computationally very efficient (three seconds analysis time for the complete data set consisting of eight cells with approx. 780.000 measurement points per cell).
Previous studies of the hyphenation of gas chromatographic separation and spectrophotometric detection in the ultraviolet wavelength range between 168 and 330 nm showed a high potential for applications where the analysis of complex samples is required. Within this paper the development of a state-of-the-art detection system for compounds in the vapour phase is described, offering an improved behaviour compared to previous systems: Dependent on the requirements of established detection systems hyphenated with gas chromatography, the main components of the system have to be designed for optimum performance and reliability of the spectrophotometric detector: A deuterium lamp as a broadband light source has been selected for improved stability in the measurements. A new-type absorption cell based on fiber-optics has been developed considering the dynamic necessary to compete with existing techniques. In addition, the influence of the volume of the cell on the chromatogram needs to be analyzed. Tests for determining the performance of the absorption cell in terms of chemical and thermal influences have been carried out. A new spectrophotometer with adequate spectral resolution in the wavelength range, offering improved stability and dynamic for an efficient use in this application was developed. Furthermore, the influence of each component on the performance, reliability and stability of the sensor system will be discussed. An overview and outlook over the potential applications in the environmental, scientific and medical field will be given.
In thin-layer chromatography, fiber-bundle arrays have been introduced for spectral absorption measurements in the UV-region. Using all-silica fiber bundles, the exciting light will be detected after re-emission on the plate with a fiberoptic spectrometer. In addition, fluorescence light can be detected which will be masked by the re-emitted light. Therefore, it is helpful to separate the absorption and fluorescence on the TLC-plate. A modified three-array assembly has been developed: using one array for detection, the two others are used for excitation with broadband band deuterium-light and with UV-LEDs adjusted to the substances under test. As an example, the quantification of glucosamine in nutritional supplements or spinach leaf extract will be described. Using simply heating of the amino-plate for derivation, the reaction product of Glucosamine can be detected sensitively either by light absorption or by fluorescence, using the new fiber-optic assembly. In addition, the properties of the new 3-row fiber-optic array and the commercially available UV-LEDs will be shown, in the interesting wavelength region for excitation of fluorescence, from 260 nm to 360 nm. The squint angle having an influence on coupling efficiency and spatial resolution will be measured with the inverse farfield method. Some properties of UV-LEDs for analytical applications will be described and discussed, too.
A wet-chemical treatment system for electrochemically coating flat substrates with coating material, has having a basin for receiving an electrolyte, a transporting means, by means of which the flat substrates can be transported through the electrolyte horizontally, and at least one contact element which comprises a shaft having an axis of rotation and a cylindrical circumferential surface suitable for rolling on the substrate, wherein the circumferential surface comprises at least one electrically insulated segment and at least one electrically conductive segment which can be connected to a current source in such a way that the polarity can be reversed, wherein the axis of rotation of the contact element is positioned above the surface of the electrolyte, and wherein the contact element is designed as a consumable electrode.
The invention relates to a device for metalising substrates. In particular, the invention relates to the field of contact elements used to electroplate solar cells within the context of a wet-chemical continuous treatment system. A wet-chemical treatment system according to the invention, for electrochemically coating flat substrates (1) with coating material, has a tank for accommodating an electrolyte, transporting means, by means of which the flat substrates (1) can be transported through the electrolyte horizontally, and at least one contact element (2), which comprises a shaft (4) having an axis of rotation (5) and a cylindrical circumferential surface suitable for rolling on the substrate (1), wherein the circumferential surface comprises at least one electrically insulating segment (3B) and at least one electrically conductive segment (3A), which can be connected to a current source (6) in such a way that the polarity can be reversed, wherein the axis of rotation (5) of the contact element (2) is positioned above the surface of the electrolyte, and wherein the contact element (2) is designed as a consumable electrode.
Variable refrigerant flow (VRF) and variable air volume (VAV) systems are considered among the best heating, ventilation, and air conditioning systems (HVAC) thanks to their ability to provide cooling and heating in different thermal zones of the same building. As well as their ability to recover the heat rejected from spaces requiring cooling and reuse it to heat another space. Nevertheless, at the same time, these systems are considered one of the most energy-consuming systems in the building. So, it is crucial to well size the system according to the building’s cooling and heating needs and the indoor temperature fluctuations. This study aims to compare these two energy systems by conducting an energy model simulation of a real building under a semi-arid climate for cooling and heating periods. The developed building energy model (BEM) was validated and calibrated using measured and simulated indoor air temperature and energy consumption data. The study aims to evaluate the effect of these HVAC systems on energy consumption and the indoor thermal comfort of the building. The numerical model was based on the Energy Plus simulation engine. The approach used in this paper has allowed us to reach significant quantitative energy saving along with a high level of indoor thermal comfort by using the VRF system compared to the VAV system. The findings prove that the VRF system provides 46.18% of the annual total heating energy savings and 6.14% of the annual cooling and ventilation energy savings compared to the VAV system.
During pyrolysis, biomass is carbonised in the absence of oxygen to produce biochar with heat and/or electricity as co-products making pyrolysis one of the promising negative emission technologies to reach climate goals worldwide. This paper presents a simplified representation of pyrolysis and analyses the impact of this technology on the energy system. Results show that the use of pyrolysis can allow getting zero emissions with lower costs by making changes in the unit commitment of the power plants, e.g. conventional power plants are used differently, as the emissions will be compensated by biochar. Additionally, the process of pyrolysis can enhance the flexibility of energy systems, as it shows a correlation between the electricity generated by pyrolysis and the hydrogen installation capacity, being hydrogen used less when pyrolysis appears. The results indicate that pyrolysis, which is available on the market, integrates well into the energy system with a promising potential to sequester carbon.
Recent advances in spiked shoe design, characterized by increased longitudinal stiffness, thicker midsole foams, and reconfigured geometry are considered to improve sprint performance. However, so far there is no empirical data on the effects of advanced spikes technology on maximal sprinting speed (MSS) published yet. Consequently, we assessed MSS via ‘flying 30m’ sprints of 44 trained male (PR: 10.32 s - 12.08 s) and female (PR: 11.56 s - 14.18 s) athletes, wearing both traditional and advanced spikes in a randomized, repeated measures design. The results revealed a statistically significant increase in MSS by 1.21% on average when using advanced spikes technology. Notably, 87% of participants showed improved MSS with the use of advanced spikes. A cluster analysis unveiled that athletes with higher MSS may benefit to a greater extent. However, individual responses varied widely, suggesting the influence of multiple factors that need detailed exploration. Therefore, coaches and athletes are advised to interpret the promising performance enhancements cautiously and evaluate the appropriateness of the advanced spike technology for their athletes critically.
High-tech running shoes and spikes ("super-footwear") are currently being debated in sports. There is direct evidence that distance running super shoes improve running economy; however, it is not well established to which extent world-class performances are affected over the range of track and road running events.
This study examined publicly available performance datasets of annual best track and road performances for evidence of potential systematic performance effects following the introduction of super footwear. The analysis was based on the 100 best performances per year for men and women in outdoor events from 2010 to 2022, provided by the world governing body of athletics (World Athletics).
We found evidence of progressing improvements in track and road running performances after the introduction of super distance running shoes in 2016 and super spike technology in 2019. This evidence is more pronounced for distances longer than 1500 m in women and longer than 5000 m in men. Women seem to benefit more from super footwear in distance running events than men.
While the observational study design limits causal inference, this study provides a database on potential systematic performance effects following the introduction of super shoes/spikes in track and road running events in world-class athletes. Further research is needed to examine the underlying mechanisms and, in particular, potential sex differences in the performance effects of super footwear.
Polyarticulated active prostheses constitute a promising solution for upper limb amputees. The bottleneck for their adoption though, is the lack of intuitive control. In this context, machine learning algorithms based on pattern recognition from electromyographic (EMG) signals represent a great opportunity for naturally operating prosthetic devices, but their performance is strongly affected by the selection of input features. In this study, we investigated different combinations of 13 EMG-derived features obtained from EMG signals of healthy individuals performing upper limb movements and tested their performance for movement classification using an Artificial Neural Network. We found that input data (i.e., the set of input features) can be reduced by more than 50% without any loss in accuracy, while diminishing the computing time required to train the classifier. Our results indicate that input features must be properly selected in order to optimize prosthetic control.
The main focus of this chapter is the theoretical and instrumental processes that underpin densitometric methods widely used in thin-layer chromatography (TLC). Densitometric methods include UV–vis, luminescence and fluorescence optical measurements as well as infrared and Raman spectroscopic measurements. The chapter is divided in two general parts: a theoretical part and a practical part. The systems for direct radioactivity measurements and the combination of TLC with mass spectrometry are also discussed. All these systems allow measuring an intensity distribution directly on a TLC plate. We call this “in situ detection” because no analyte is removed from the plate.
The main focus of this chapter is the theoretical and instrumental processes that underpin densitometric methods widely used in thin-layer chromatography (TLC). Densitometric methods include UV–vis, luminescence, and fluorescence optical measurements as well as infrared and Raman spectroscopic measurements. The chapter is divided in two general parts: a theoretical part and a practical part. The systems for direct radioactivity measurements and the combination of TLC with mass spectrometry are also discussed. All these systems allow measuring an intensity distribution directly on a TLC plate. We call this “in situ detection” because no analyte is removed from the plate.
Recently, photovoltaic (PV) with energy storage systems (ESS) have been widely adopted in buildings to overcome growing power demands and earn financial benefits. The overall energy cost can be optimized by combining a well-sized hybrid PV/ESS system with an efficient energy management system (EMS). Generally, EMS is implemented within the overall functions of the Building Automation System (BAS). However, due to its limited computing resources, BAS cannot handle complex algorithms that aim to optimize energy use in real-time under different operating conditions. Furthermore, islanding the building's local network to maximize the PV energy share represents a challenging task due to the potential technical risks. In this context, this article addresses an improved approach based on upgrading the BAS data analytics capability by means of an edge computing technology. The edge communicates with the BAS low-level controller using a serial communication protocol. Taking advantage of the high computing ability of the edge device, an optimization-based EMS of the PV/ESS hybrid system is implemented. Different testing scenarios have been carried out on a real prototype with different weather conditions, and the results show the implementation feasibility and technical performance of such advanced EMS for the management of building energy resources. It has also been proven to be feasible and advantageous to operate the local energy network in island mode while ensuring system safety. Additionally, an estimated energy saving improvement of 6.23 % has been achieved using optimization-based EMS compared to the classical rule-based EMS, with better ESS constraints fulfillment.
For the treatment of bone defects, biodegradable, compressive biomaterials are needed as replacements that degrade as the bone regenerates. The problem with existing materials has either been their insufficient mechanical strength or the excessive differences in their elastic modulus, leading to stress shielding and eventual failure. In this study, the compressive strength of CPC ceramics (with a layer thickness of more than 12 layers) was compared with sintered β-TCP ceramics. It was assumed that as the number of layers increased, the mechanical strength of 3D-printed scaffolds would increase toward the value of sintered ceramics. In addition, the influence of the needle inner diameter on the mechanical strength was investigated. Circular scaffolds with 20, 25, 30, and 45 layers were 3D printed using a 3D bioplotter, solidified in a water-saturated atmosphere for 3 days, and then tested for compressive strength together with a β-TCP sintered ceramic using a Zwick universal testing machine. The 3D-printed scaffolds had a compressive strength of 41.56 ± 7.12 MPa, which was significantly higher than that of the sintered ceramic (24.16 ± 4.44 MPa). The 3D-printed scaffolds with round geometry reached or exceeded the upper limit of the compressive strength of cancellous bone toward substantia compacta. In addition, CPC scaffolds exhibited more bone-like compressibility than the comparable β-TCP sintered ceramic, demonstrating that the mechanical properties of CPC scaffolds are more similar to bone than sintered β-TCP ceramics.