With recent developments in the Ukrainian-Russian conflict, many are discussing about Germany’s dependency on fossil fuel imports in its energy system, and how can the country proceed with reducing that dependency. With its wide-ranging consumption sectors, the electricity sector comes as the perfect choice to start with. Recent reports showed that the German federal government is already intending to have a fully renewable electricity by 2035 while exploiting all possible clean power options. This was published in the federal government’s climate emergency program (Easter Package) in early 2022. The aim of this package is to initiate a rapid transition and decarbonization of the electricity sector. The Easter Package expects an enormous growth of renewable energies to a completely new level, with already at least 80% renewable gross energy consumption, with extensive and broad deployment of different generation technologies on various scales. This paper will discuss this ambitious plan and outline some insights into this huge and rapidly increasing step, and show how much will Germany need in order to achieve this huge milestone towards a fully green supply of the electricity sector. Different scenarios and shares of renewables will be investigated in order to elaborate on preponed climate-neutral goal of the electricity sector by 2035. The results pointed out some promising aspects in achieving a 100% renewable power, with massive investments in both generation and storage technologies.
In this paper, the J-integral is derived for temperature-dependent elastic–plastic materials described by incremental plasticity. It is implemented using the equivalent domain integral method for assessment of three-dimensional cracks based on results of finite-element calculations. The J-integral considers contributions from inhomogeneous temperature fields and temperature-dependent elastic and plastic material properties as well as from gradients in the plastic strains and the hardening variables. Different energy densities are considered, the Helmholtz free energy and the stress-working density, providing a physical meaning of the J-integral as a fracture criteria for crack growth. Results obtained for a plate with two different crack configurations each loaded by a cool-down thermal shock show domain-independence of the incremental J-integral for different energy densities even for high temperature gradients and significant temperature-dependence of the yield stress and the hardening exponent in the presence of large scale yielding. Hence, the derived J-integral is an appropriate parameter for the assessment of cracks in thermomechanically loaded components.
A balcony photovoltaic (PV) system, also known as a micro-PV system, is a small PV system consisting of one or two solar modules with an output of 100–600 Wp and a corresponding inverter that uses standard plugs to feed the renewable energy into the house grid. In the present study we demonstrate the integration of a commercial lithium-ion battery into a commercial micro-PV system. We firstly show simulations over one year with one second time resolution which we use to assess the influence of battery and PV size on self-consumption, self-sufficiency and the annual cost savings. We then develop and operate experimental setups using two different architectures for integrating the battery into the micro-PV system. In the passive hybrid architecture, the battery is in parallel electrical connection to the PV module. In the active hybrid architecture, an additional DC-DC converter is used. Both architectures include measures to avoid maximum power point tracking of the battery by the module inverter. Resulting PV/battery/inverter systems with 300 Wp PV and 555 Wh battery were tested in continuous operation over three days under real solar irradiance conditions. Both architectures were able to maintain stable operation and demonstrate the shift of PV energy from the day into the night. System efficiencies were observed comparable to a reference system without battery. This study therefore demonstrates the feasibility of both active and passive coupling architectures.
For the treatment of bone defects, biodegradable, compressive biomaterials are needed as replacements that degrade as the bone regenerates. The problem with existing materials has either been their insufficient mechanical strength or the excessive differences in their elastic modulus, leading to stress shielding and eventual failure. In this study, the compressive strength of CPC ceramics (with a layer thickness of more than 12 layers) was compared with sintered β-TCP ceramics. It was assumed that as the number of layers increased, the mechanical strength of 3D-printed scaffolds would increase toward the value of sintered ceramics. In addition, the influence of the needle inner diameter on the mechanical strength was investigated. Circular scaffolds with 20, 25, 30, and 45 layers were 3D printed using a 3D bioplotter, solidified in a water-saturated atmosphere for 3 days, and then tested for compressive strength together with a β-TCP sintered ceramic using a Zwick universal testing machine. The 3D-printed scaffolds had a compressive strength of 41.56 ± 7.12 MPa, which was significantly higher than that of the sintered ceramic (24.16 ± 4.44 MPa). The 3D-printed scaffolds with round geometry reached or exceeded the upper limit of the compressive strength of cancellous bone toward substantia compacta. In addition, CPC scaffolds exhibited more bone-like compressibility than the comparable β-TCP sintered ceramic, demonstrating that the mechanical properties of CPC scaffolds are more similar to bone than sintered β-TCP ceramics.
Die Erfindung betrifft eine Vorrichtung zur biologischen Methanisierung von CO und/oder CO2 mittels methanogener Mikroorganismen durch Umsetzung von H2 und CO und/oder CO2, die eine Begasungskolonne und eine Entgasungskolonne, jeweils mit einer Bodenseite und einer der Bodenseite gegenüberliegenden oberen Seite, ein in der Begasungskolonne und der Entgasungskolonne bereitgestelltes Medium mit methanogenen Mikroorganismen, eine Zuführeinrichtung zum Zuführen eines H2 enthaltenden Gases in das Medium der Begasungskolonne, eine Abführeinrichtung zum Abführen eines CH4 enthaltenden Gases aus der Entgasungskolonne, eine Verbindungsleitung zwischen Begasungskolonne und Entgasungskolonne im Bereich der Bodenseiten, eine Pumpe zum Überführen von Medium über die Verbindungsleitung von der Begasungskolonne in die Entgasungskolonne, und eine Rückführleitung zwischen der Begasungskolonne und der Entgasungskolonne im Bereich der oberen Seiten zum Rückführen von Medium aus der Entgasungskolonne in die Begasungskolonne aufweist. Die Erfindung betrifft auch ein Verfahren zur biologischen Methanisierung von CO und/oder CO2 in einer Vorrichtung mittels methanogener Mikroorganismen als Teil eines in der Vorrichtung bereitgestellten Mediums, wobei das Medium in einem Kreislauf über eine Begasungskolonne und eine Entgasungskolonne geführt wird, wobei die Kolonnen jeweils über eine Verbindungsleitung im Bereich ihrer Bodenseiten und über eine Rückführleitung im Bereich der den Bodenseiten gegenüberliegenden oberen Seiten miteinander verbunden sind, worin das Medium sich in der Begasungskolonne absteigend und in der Entgasungskolonne aufsteigend bewegt, worin dem Medium in der Begasungskolonne ein H2 enthaltendes Gas zugeführt wird.
The use of renewable energy sources for heating and cooling in buildings today offers the best opportunities to avoid the use of fossil fuels and the associated climate-damaging emissions. However, unlike fossil fuels, renewable energy sources such as solar radiation are not available at the push of a button, but occur uncontrollably depending on weather conditions, the location of the building and the time of year. Their use is free of charge. However, complex converters and systems usually have to be installed in order to use them. These must be carefully planned and operated in order to avoid unnecessary costs and to generate the maximum possible yield. The regenerative energy systems are usually integrated into existing conventional systems. When designing the control and regulation equipment, it is crucial to design the automation of the systems in such a way that primarily renewable energy sources are used and the share of fossil energy sources is minimized.
Automation devices or automation stations (AS) take on the task of controlling, regulating, monitoring and, if necessary, optimising building systems and their system components (e.g. pumps, compressors, fans) based on recorded process variables. For this purpose, a wide range of control and regulation methods are used, starting with simple on/off controllers, through classic PID controllers, to higher-order controllers such as adaptive, model-predictive, knowledge-based or adaptive controllers.
Starting with a brief introduction to automation technology (Sect. 7.1), the chapter goes into the structure and functionality of the usual compact controllers using the application examples of solar thermal systems and heat pump systems (Sect. 7.2). Finally, the integration of system automation into a higher-level building automation system and into the building management system is described using specific application examples (Sect. 7.3).
This central book chapter now details the implementation of automation of solar domestic hot water systems, solar assisted building heating, rooms, solar cooling systems, heat pump heating systems, geothermal systems and thermally activated building component systems. Hydraulic and automation diagrams are used to explain how the automation of these systems works. A detailed insight into the engineering and technical interrelationships involved in the use of these systems, as well as the use of simulation tools, enables effective control and regulation. System characteristic curves and systematic procedures support the automation engineer in his tasks.
Renewable energy sources such as solar radiation, geothermal heat and ambient heat are available for energy conversion. With the help of special converters, these resources can be put to use. These include solar collectors, geothermal probes and chillers. They collect the energy and convert it to a temperature level high enough to be suitable for heat purposes. In the case of refrigeration machines, a distinction is made between electrically and thermally driven machines.
Lithium-ion batteries exhibit slow voltage dynamics on the minute time scale that are usually associated with transport processes. We present a novel modelling approach toward these dynamics by combining physical and data-driven models into a Grey-box model. We use neural networks, in particular neural ordinary differential equations. The physical structure of the Grey-box model is borrowed from the Fickian diffusion law, where the transport domain is discretized using finite volumes. Within this physical structure, unknown parameters (diffusion coefficient, diffusion length, discretization) and dependencies (state of charge, lithium concentration) are replaced by neural networks and learnable parameters. We perform model-to-model comparisons, using as training data (a) a Fickian diffusion process, (b) a Warburg element, and (c) a resistor-capacitor circuit. Voltage dynamics during constant-current operation and pulse tests as well as electrochemical impedance spectra are simulated. The slow dynamics of all three physical models in the order of ten to 30 min are well captured by the Grey-box model, demonstrating the flexibility of the present approach.
This article presents the development, parameterization, and experimental validation of a pseudo-three-dimensional (P3D) multiphysics aging model of a 500 mAh high-energy lithium-ion pouch cell with graphite negative electrode and lithium nickel manganese cobalt oxide (NMC) positive electrode. This model includes electrochemical reactions for solid electrolyte interphase (SEI) formation at the graphite negative electrode, lithium plating, and SEI formation on plated lithium. The thermodynamics of the aging reactions are modeled depending on temperature and ion concentration and the reactions kinetics are described with an Arrhenius-type rate law. Good agreement of model predictions with galvanostatic charge/discharge measurements and electrochemical impedance spectroscopy is observed over a wide range of operating conditions. The model allows to quantify capacity loss due to cycling near beginning-of-life as function of operating conditions and the visualization of aging colormaps as function of both temperature and C-rate (0.05 to 2 C charge and discharge, −20 °C to 60 °C). The model predictions are also qualitatively verified through voltage relaxation, cell expansion and cell cycling measurements. Based on this full model, six different aging indicators for determination of the limits of fast charging are derived from post-processing simulations of a reduced, pseudo-two-dimensional isothermal model without aging mechanisms. The most successful aging indicator, compared to results from the full model, is based on combined lithium plating and SEI kinetics calculated from battery states available in the reduced model. This methodology is applicable to standard pseudo-two-dimensional models available today both commercially and as open source.
In this paper we report on further success of our work to develop a multi-method energy optimization which works with a digital twin concept. The twin concept serves to replicate production processes of different kinds of production companies, including complex energy systems and test market interactions to then use them for model predictive optimizing. The presented work finally reports about the performed flexibility assessment leading to a flexibility audit with a list of measures and the impact of energy optimizations made related to interactions with the local power grid i.e., the exchange node of the low voltage distribution grid. The analysis and continuous exploration of flexibilities as well as the exchange with energy markets require a “guide” leading to continuous optimization with a further tool like the Flexibility Survey and Control Panel helping decision-making processes on the day-ahead horizon for real production plants or the investment planning to improve machinery, staff schedules and production
infrastructure.
Polyarticulated active prostheses constitute a promising solution for upper limb amputees. The bottleneck for their adoption though, is the lack of intuitive control. In this context, machine learning algorithms based on pattern recognition from electromyographic (EMG) signals represent a great opportunity for naturally operating prosthetic devices, but their performance is strongly affected by the selection of input features. In this study, we investigated different combinations of 13 EMG-derived features obtained from EMG signals of healthy individuals performing upper limb movements and tested their performance for movement classification using an Artificial Neural Network. We found that input data (i.e., the set of input features) can be reduced by more than 50% without any loss in accuracy, while diminishing the computing time required to train the classifier. Our results indicate that input features must be properly selected in order to optimize prosthetic control.
During pyrolysis, biomass is carbonised in the absence of oxygen to produce biochar with heat and/or electricity as co-products making pyrolysis one of the promising negative emission technologies to reach climate goals worldwide. This paper presents a simplified representation of pyrolysis and analyses the impact of this technology on the energy system. Results show that the use of pyrolysis can allow getting zero emissions with lower costs by making changes in the unit commitment of the power plants, e.g. conventional power plants are used differently, as the emissions will be compensated by biochar. Additionally, the process of pyrolysis can enhance the flexibility of energy systems, as it shows a correlation between the electricity generated by pyrolysis and the hydrogen installation capacity, being hydrogen used less when pyrolysis appears. The results indicate that pyrolysis, which is available on the market, integrates well into the energy system with a promising potential to sequester carbon.
Energy efficiency and hygrothermal performance of hemp clay walls for Moroccan residential buildings
(2023)
Hemp-based building envelopes have gained significant popularity in developed countries, and now the trend of constructing houses with hemp-clay blocks is spreading to developing countries like Morocco. Investigating the hygrothermal behavior of such structures under actual climate conditions is essential for advancing and promoting this sustainable practice. This paper presents an in-depth experimental characterization of a commercial hemp-clay brick that has been exposed to the outdoor environment for four years, in addition to field measurements on a building scale demonstration prototype. Additionally, the study simulates 17 representative cities to assess the hygrothermal performance and energy-saving potential in each of Morocco's six existing climate zones, using the EnergyPlus engine. The experimental campaign's findings demonstrate excellent indoor air temperature and relative humidity regulation within the hemp-clay wall building, leading to satisfactory levels of thermal comfort within hemp-clay wall buildings. This is attributed to the material's good thermal conductivity and excellent moisture buffering capacity (found to be 0.31 W/mK and 2.25 g/m2%RH), respectively). The energy simulation findings also point to significant energy savings, with cooling and heating energy reductions ranging from 27.7% to 47.5% and 33.7% to 79.8%, respectively, as compared to traditional Moroccan buildings.
This paper presents a framework for numerical building validation enhancement based on detailed building specifications from in-situ measurements and evidence-based validation assessment undertaken on a detached sustainable lightweight building in a semi-arid climate. The validation process has been undergone in a set of controlled experiments – a free-float period, and steady-state internal temperatures. The validation was conducted for a complete year with a 1-min time step for the hourly indoor temperature and the variable refrigerant flow (VRF) energy consumption. The initial baseline model was improved by three series of validation steps per three different field measurements including thermal transmittance, glazing thermal and optical properties, and airtightness. Then, the accurate and validated model was used for building energy efficiency assessment in 12 regions of Morocco. This study aims to assess the effect of accurate building characteristics values on the numerical model enhancement. The initial CV(RMSE) and NMBE have improved respectively from 14.58 % and −11.23 %–7.85 % and 1.86 % for the indoor temperature. Besides, from 31.17 % to 14.37 %–20.57 % and 9.77 % for energy consumption. The findings demonstrate that the lightweight construction with the use of a variable refrigerant flow system could be energy efficient in the southern regions of Morocco.
To improve the building’s energy efficiency many parameters should be assessed considering the building envelope, energy loads, occupation, and HVAC systems. Fenestration is among the most important variables impacting residential building indoor temperatures. So, it is crucial to use the most optimal energy-efficient window glazing in buildings to reduce energy consumption and at the same time provide visual daylight comfort and thermal comfort. Many studies have focused on the improvement of building energy efficiency focusing on the building envelope or the heating, ventilation, and cooling systems. But just a few studies have focused on studying the effect of glazing on building energy consumption. Thus, this paper aims to study the influence of different glazing types on the building’s heating and cooling energy consumption. A real case study building located under a semi-arid climate was used. The building energy model has been conducted using the OpenStudio simulation engine. Building indoor temperature was calibrated using ASHRAE’s statistical indices. Then a comparative analysis was conducted using seven different types of windows including single, double, and triple glazing filled with air and argon. Tripleglazed and double-glazed windows with argon space offer 37% and 32% of annual energy savings. It should be stressed that the methodology developed in this paper could be useful for further studies to improve building energy efficiency using optimal window glazing.
The variable refrigerant flow system is one of the best heating, ventilation, and air conditioning systems (HVAC) thanks to its ability to provide thermal comfort inside buildings. But, at the same time, these systems are considered one of the most energy-consuming systems in the building sector. Thus, it is crucial to well size the system according to the building’s cooling and heating needs and the indoor temperature fluctuations. Although many researchers have studied the optimization of the building energy performance considering heating or cooling needs, using air handling units, radiant floor heating, and direct expansion valves, few studies have considered the use of multi-objective optimization using only the thermostat setpoints of VRF systems for both cooling and heating needs. Thus, the main aim of this study is to conduct a sensitivity analysis and a multi-objective optimization strategy for a residential building containing a variable refrigerant flow system, to evaluate the effect of the building performance on energy consumption and improve the building energy efficiency. The numerical model was based on the EnergyPlus, jEPlus, and jEPlus+EA simulation engines. The approach used in this paper has allowed us to reach significant quantitative energy saving by varying the cooling and heating setpoints and scheduling scenarios. It should be stressed that this approach could be applied to several HVAC systems to reduce energy-building consumption.
Variable refrigerant flow (VRF) and variable air volume (VAV) systems are considered among the best heating, ventilation, and air conditioning systems (HVAC) thanks to their ability to provide cooling and heating in different thermal zones of the same building. As well as their ability to recover the heat rejected from spaces requiring cooling and reuse it to heat another space. Nevertheless, at the same time, these systems are considered one of the most energy-consuming systems in the building. So, it is crucial to well size the system according to the building’s cooling and heating needs and the indoor temperature fluctuations. This study aims to compare these two energy systems by conducting an energy model simulation of a real building under a semi-arid climate for cooling and heating periods. The developed building energy model (BEM) was validated and calibrated using measured and simulated indoor air temperature and energy consumption data. The study aims to evaluate the effect of these HVAC systems on energy consumption and the indoor thermal comfort of the building. The numerical model was based on the Energy Plus simulation engine. The approach used in this paper has allowed us to reach significant quantitative energy saving along with a high level of indoor thermal comfort by using the VRF system compared to the VAV system. The findings prove that the VRF system provides 46.18% of the annual total heating energy savings and 6.14% of the annual cooling and ventilation energy savings compared to the VAV system.
In this paper, the time- and temperature-dependent cyclic ratchetting plasticity of the nickel-based alloy IN100 is experimentally investigated in strain-controlled experiments in the temperature range from 300 °C to 1050 °C. To this end, uniaxial material tests are performed with complex loading histories designed to activate phenomena as strain rate dependency, stress relaxation as well as the Bauschinger effect, cyclic hardening and softening, ratchetting and recovery from hardening. Plasticity models with different levels of complexity are presented that consider these phenomena, and a strategy is derived to determine the multitude of temperature-dependent material properties of the models in a step-by-step procedure based on sub-sets of experimental data of isothermal experiments. The models and the material properties are validated based on the results of non-isothermal experiments. A good description of the time- and temperature-dependent cyclic ratchetting plasticity of IN100 is obtained for isothermal as well as non-isothermal loading with models including ratchetting terms in the kinematic hardening law and the material properties obtained with the proposed strategy.