Refine
Year of publication
Document Type
- Article (reviewed) (108)
- Conference Proceeding (59)
- Article (unreviewed) (21)
- Report (19)
- Part of a Book (11)
- Contribution to a Periodical (7)
- Book (6)
- Doctoral Thesis (4)
- Patent (4)
Conference Type
- Konferenzartikel (48)
- Konferenz-Abstract (10)
- Konferenz-Poster (1)
Is part of the Bibliography
- yes (239) (remove)
Keywords
- Lithiumbatterie (10)
- Energieversorgung (9)
- Haustechnik (9)
- Brennstoffzelle (7)
- Wärmepumpe (6)
- Batterie (5)
- Fotovoltaik (5)
- lithium-ion battery (5)
- Bauteil (4)
- Elektrochemie (4)
Institute
- INES - Institut für nachhaltige Energiesysteme (239) (remove)
Open Access
- Open Access (112)
- Closed Access (64)
- Closed (21)
- Bronze (15)
- Diamond (13)
- Gold (13)
- Grün (6)
- Hybrid (3)
Photovoltaic-heat pump (PV-HP) combinations with battery and energy management systems are becoming increasingly popular due to their ability to increase the autarchy and utilization of self-generated PV electricity. This trend is driven by the ongoing electrification of the heating sector and the growing disparity between growing electricity costs and reducing feed-in tariffs in Germany. Smart control strategies can be employed to control and optimize the heat pump operation to achieve higher self-consumption of PV electricity. This work presents the evaluation results of a smart-grid ready controlled PV-HP-battery system in a single-family household in Germany, using 1-minute-high-resolution field measurement data. Within 12 months evaluation period, a self-consumption of 43% was determined. The solar fraction of the HP amounts to 36%, enabled also due to higher set temperatures for space heating and domestic hot water production. Accordingly, the SPF decreases by 4.0% the space heating and by 5.7% in the domestic hot water mode. The combined seasonal performance factor for the heat pump system increases from 4.2 to 6.7, when only considering the electricity taken from the grid and disregarding the locally generated electricity supplied from photovoltaic and battery units.
This paper provides a comprehensive overview of approaches to the determination of isocontours and isosurfaces from given data sets. Different algorithms are reported in the literature for this purpose, which originate from various application areas, such as computer graphics or medical imaging procedures. In all these applications, the challenge is to extract surfaces with a specific isovalue from a given characteristic, so called isosurfaces. These different application areas have given rise to solution approaches that all solve the problem of isocontouring in their own way. Based on the literature, the following four dominant methods can be identified: the marching cubes algorithms, the tessellation-based algorithms, the surface nets algorithms and the ray tracing algorithms. With regard to their application, it can be seen that the methods are mainly used in the fields of medical imaging, computer graphics and the visualization of simulation results. In our work, we provide a broad and compact overview of the common methods that are currently used in terms of isocontouring with respect to certain criteria and their individual limitations. In this context, we discuss the individual methods and identify possible future research directions in the field of isocontouring.
Batteries typically consist of multiple individual cells connected in series. Here we demonstrate single-cell state of charge (SOC) and state of health (SOH) diagnosis in a 24 V class lithium-ion battery. To this goal, we introduce and apply a novel, highly efficient algorithm based on a voltage-controlled model (VCM). The battery, consisting of eight single cells, is cycled over a duration of five months under a simple cycling protocol between 20 % and 100 % SOC. The cell-to-cell standard deviations obtained with the novel algorithm were 1.25 SOC-% and 1.07 SOH-% at beginning of cycling. A cell-averaged capacity loss of 9.9 % after five months cycling was observed. While the accuracy of single-cell SOC estimation was limited (probably owed to the flat voltage characteristics of the lithium iron phosphate, LFP, chemistry investigated here), single-cell SOH estimation showed a high accuracy (2.09 SOH-% mean absolute error compared to laboratory reference tests). Because the algorithm does not require observers, filters, or neural networks, it is computationally very efficient (three seconds analysis time for the complete data set consisting of eight cells with approx. 780.000 measurement points per cell).
The nonlinear behavior of inverters is largely impacted by the interlocking and switching times. A method for online identifying the switching times of semiconductors in inverters is presented in the following work. By being able to identify these times, it is possible to compensate for the nonlinear behavior, reduce interlocking time, and use the information for diagnostic purposes. The method is first theoretically derived by examining different inverter switching cases and determining potential identification possibilities. It is then modified to consider the entire module for more robust identification. The methodology, including limitations and boundary conditions, is investigated and a comparison of two methods of measurement acquisition is provided. Subsequently the developed hardware is described and the implementation in an FPGA is carried out. Finally, the results are presented, discussed, and potential challenges are encountered.
The present work describes an extension of current slope estimation for parameter estimation of permanent magnet synchronous machines operated at inverters. The area of operation for current slope estimation in the individual switching states of the inverter is limited due to measurement noise, bandwidth limitation of the current sensors and the commutation processes of the inverter's switching operations. Therefore, a minimum duration of each switching state is necessary, limiting the final area of operation of a robust current slope estimation. This paper presents an extension of existing current slope estimation algorithms resulting in a greater area of operation and a more robust estimation result.
Electrochemical pressure impedance spectroscopy (EPIS) has received the attention of researchers as a method to study mass transport processes in polymer electrolyte mem-brane fuel cells (PEMFC). It is based on analyzing the cell voltage response to a harmonic excitation of the gas phase pressure in the frequency domain. Several experiments with a single-cell fuel cell have shown that the spectra contain information in the frequency range typical for mass transport processes and are sensitive to specific operating condi-tions and structural fuel cell parameters. To further benefit from the observed features, it is essential to identify why they occur, which to date has not yet been accomplished. The aim of the present work, therefore, is to identify causal links between internal processes and the corresponding EPIS features.
To this end, the study follows a model-based approach, which allows the analysis of inter-nal states that are not experimentally accessible. The PEMFC model is a pseudo-2D model, which connects the mass transport along the gas channel with the mass transport through the membrane electrode assembly. A modeling novelty is the consideration of the gas vol-ume inside the humidifier upstream the fuel cell inlet, which proves to be crucial for the reproduction of EPIS. The PEMFC model is parametrized to a 100 cm² single cell of the French project partner, who provided the experimental EPIS results reproduced and in-terpreted in the present study.
The simulated EPIS results show a good agreement with the experiments at current den-sities ≤ 0.4 A cm–2, where they allow a further analysis of the observed features. At the lowest excitation frequency of 1 mHz, the dynamic cell voltage response approaches the static pressure-voltage response. In the simulated frequency range between 1 mHz – 100 Hz, the cell voltage oscillation is found to strongly correlate with the partial pressure oscillation of oxygen, whereas the influence of the water pressure is limited to the low frequency region.
The two prominent EPIS features, namely the strong increase of the cell voltage oscillation and the increase of phase shift with frequency, can be traced back via the oxygen pressure to the oscillation of the inlet flow rate. The phenomenon of the oscillating inlet flow rate is a consequence of the pressure change of the gas phase inside the humidifier and in-creases with frequency. This important finding enables the interpretation of experimen-tally observed EPIS trends for a variation of operational and structural fuel cell parame-ters by tracing them back to the influence of the oscillating inlet flow rate.
The separate simulation of the time-dependent processes of the PEMFC model through model reduction shows their individual influence on EPIS. The sluggish process of the wa-ter uptake by the membrane is visible below 0.1 Hz, while the charge and discharge of the double layer becomes visible above 1 Hz. The gas transport through the gas diffusion layer is only visible above 100 Hz. The simulation of the gas transport through the gas channel
without consideration of the humidifier becomes visible above 1 Hz. With consideration of the humidifier the gas transport through the gas channel is visible throughout the fre-quency range. The strong similarity of the spectra considering the humidifier with the spectra of the full model setup shows the dominant influence of the humidifier on EPIS.
A promising observation is the change in the amplitude relationship between the cell volt-age and the oxygen partial pressure oscillation as a function of the oxygen concentration in the catalyst layer. At a frequency where the influence of oxygen pressure on the cell voltage is dominant, for example at 1 Hz, the amplitude of the cell voltage oscillation could be used to indirectly measure the oxygen concentration in the catalyst layer.
This article presents the development, parameterization, and experimental validation of a pseudo-three-dimensional (P3D) multiphysics aging model of a 500 mAh high-energy lithium-ion pouch cell with graphite negative electrode and lithium nickel manganese cobalt oxide (NMC) positive electrode. This model includes electrochemical reactions for solid electrolyte interphase (SEI) formation at the graphite negative electrode, lithium plating, and SEI formation on plated lithium. The thermodynamics of the aging reactions are modeled depending on temperature and ion concentration and the reactions kinetics are described with an Arrhenius-type rate law. Good agreement of model predictions with galvanostatic charge/discharge measurements and electrochemical impedance spectroscopy is observed over a wide range of operating conditions. The model allows to quantify capacity loss due to cycling near beginning-of-life as function of operating conditions and the visualization of aging colormaps as function of both temperature and C-rate (0.05 to 2 C charge and discharge, −20 °C to 60 °C). The model predictions are also qualitatively verified through voltage relaxation, cell expansion and cell cycling measurements. Based on this full model, six different aging indicators for determination of the limits of fast charging are derived from post-processing simulations of a reduced, pseudo-two-dimensional isothermal model without aging mechanisms. The most successful aging indicator, compared to results from the full model, is based on combined lithium plating and SEI kinetics calculated from battery states available in the reduced model. This methodology is applicable to standard pseudo-two-dimensional models available today both commercially and as open source.
Variable refrigerant flow (VRF) and variable air volume (VAV) systems are considered among the best heating, ventilation, and air conditioning systems (HVAC) thanks to their ability to provide cooling and heating in different thermal zones of the same building. As well as their ability to recover the heat rejected from spaces requiring cooling and reuse it to heat another space. Nevertheless, at the same time, these systems are considered one of the most energy-consuming systems in the building. So, it is crucial to well size the system according to the building’s cooling and heating needs and the indoor temperature fluctuations. This study aims to compare these two energy systems by conducting an energy model simulation of a real building under a semi-arid climate for cooling and heating periods. The developed building energy model (BEM) was validated and calibrated using measured and simulated indoor air temperature and energy consumption data. The study aims to evaluate the effect of these HVAC systems on energy consumption and the indoor thermal comfort of the building. The numerical model was based on the Energy Plus simulation engine. The approach used in this paper has allowed us to reach significant quantitative energy saving along with a high level of indoor thermal comfort by using the VRF system compared to the VAV system. The findings prove that the VRF system provides 46.18% of the annual total heating energy savings and 6.14% of the annual cooling and ventilation energy savings compared to the VAV system.
During pyrolysis, biomass is carbonised in the absence of oxygen to produce biochar with heat and/or electricity as co-products making pyrolysis one of the promising negative emission technologies to reach climate goals worldwide. This paper presents a simplified representation of pyrolysis and analyses the impact of this technology on the energy system. Results show that the use of pyrolysis can allow getting zero emissions with lower costs by making changes in the unit commitment of the power plants, e.g. conventional power plants are used differently, as the emissions will be compensated by biochar. Additionally, the process of pyrolysis can enhance the flexibility of energy systems, as it shows a correlation between the electricity generated by pyrolysis and the hydrogen installation capacity, being hydrogen used less when pyrolysis appears. The results indicate that pyrolysis, which is available on the market, integrates well into the energy system with a promising potential to sequester carbon.
Lithium-ion battery cells exhibit a complex and nonlinear coupling of thermal, electrochemical,and mechanical behavior. In order to increase insight into these processes, we report the development of a pseudo-three-dimensional (P3D) thermo-electro-mechanical model of a commercial lithium-ion pouch cell with graphite negative electrode and lithium nickel cobalt aluminum oxide/lithium cobalt oxide blend positive electrode. Nonlinear molar volumes of the active materials as function of lithium stoichiometry are taken from literature and implemented into the open-source software Cantera for convenient coupling to battery simulation codes. The model is parameterized and validated using electrical, thermal and thickness measurements over a wide range of C-rates from 0.05 C to 10 C. The combined experimental and simulated analyses show that thickness change during cycling is dominated by intercalation-induced swelling of graphite, while swelling of the two blend components partially cancel each other. At C-rates above 2 C, electrochemistry-induced temperature increase significantly contributes to cell swelling due to thermal expansion. The thickness changes are nonlinearly distributed over the thickness of the electrode pair due to gradients in the local lithiation, which may accelerate local degradation. Remaining discrepancies between simulation and experiment at high C-rates might be attributed to lithium plating, which is not considered in the model at present.
Electrochemical pressure impedance spectroscopy (EPIS) is an emerging tool for the diagnosis of polymer electrolyte membrane fuel cells (PEMFC). It is based on analyzing the frequency response of the cell voltage with respect to an excitation of the gas-phase pressure. Several experimental studies in the past decade have shown the complexity of EPIS signals, and so far there is no agreement on the interpretation of EPIS features. The present study contributes to shed light into the physicochemical origin of EPIS features, by using a combination of pseudo-two-dimensional modeling and analytical interpretation. Using static simulations, the contributions of cathode equilibrium potential, cathode overpotential, and membrane resistance on the quasi-static EPIS response are quantified. Using model reduction, the EPIS responses of individual dynamic processes are predicted and compared to the response of the full model. We show that the EPIS signal of the PEMFC studied here is dominated by the humidifier. The signal is further analyzed by using transfer functions between various internal cell states and the outlet pressure excitation. We show that the EPIS response of the humidifier is caused by an oscillating oxygen molar fraction due to an oscillating mass flow rate.
A balcony photovoltaic (PV) system, also known as a micro-PV system, is a small PV system consisting of one or two solar modules with an output of 100–600 Wp and a corresponding inverter that uses standard plugs to feed the renewable energy into the house grid. In the present study we demonstrate the integration of a commercial lithium-ion battery into a commercial micro-PV system. We firstly show simulations over one year with one second time resolution which we use to assess the influence of battery and PV size on self-consumption, self-sufficiency and the annual cost savings. We then develop and operate experimental setups using two different architectures for integrating the battery into the micro-PV system. In the passive hybrid architecture, the battery is in parallel electrical connection to the PV module. In the active hybrid architecture, an additional DC-DC converter is used. Both architectures include measures to avoid maximum power point tracking of the battery by the module inverter. Resulting PV/battery/inverter systems with 300 Wp PV and 555 Wh battery were tested in continuous operation over three days under real solar irradiance conditions. Both architectures were able to maintain stable operation and demonstrate the shift of PV energy from the day into the night. System efficiencies were observed comparable to a reference system without battery. This study therefore demonstrates the feasibility of both active and passive coupling architectures.
Given the looming threats of climate change and the rapid worldwide urbanization, it is a necessity to prioritize the transition towards a carbon-free built environment. This research study provides a holistic digital methodology for parametric design of urban residential buildings with regard to the Mediterranean semi-arid climate zone of Morocco in the early design phase. The morphological parameters of the urban residential buildings, namely the buildings’ typology, the distance between buildings, the urban grid’s orientation, and the window-towall ratio, are evaluated in order to identify the key combinations of passive and active solar design strategies that determine the high energy performing configurations, based on the introduced Energy Performance Index (EPI), which is the ratio between solar BIPV production to maximum available installed BIPV capacity and the normalized thermal energy needs. Through an automated processing of 2187 iterations via Grasshopper, we simulate daylight autonomy, indoor thermal comfort and solar rooftop photovoltaic and building integrated photovoltaic (BIPV) energy potential. Then, we analyze the conflicting objectives of energy efficiency measures, active solar design strategies, and indoor visual comfort in the decision-making process that supports our goal of getting closer to net zero urban residential buildings. The digital workflow showed interesting trends in reaching a balanced equilibrium between performance metrics influenced by the contrasting impact of solar exposure on indoor daylight autonomy and thermal energy demand. Furthermore, the study’s findings indicate that it is possible to achieve an annual load match exceeding 66,56 % while simultaneously ensuring an acceptable visual indoor comfort (sDA higher than 0.4). The findings also highlight the important role of the BIPV system in shifting towards the net zero energy goal, by contributing up to 30 % of the overall solar energy output and covering up to 20 % of the yearly self-consumption. Moreover, the energy balance evaluation on an hourly basis indicates that BIPV system notably enhances the daily load cover factor by up to 5.5 %, particularly in the case of slab SN typology, throughout the different seasons. Graphical representations of the yearly, monthly and hourly load matches and the hourly energy balance of the best performing configurations provide a thorough understanding of the potential evolution of the urban energy system over time as a result of the gradual integration of active solar electricity production.
Energy efficiency and hygrothermal performance of hemp clay walls for Moroccan residential buildings
(2023)
Hemp-based building envelopes have gained significant popularity in developed countries, and now the trend of constructing houses with hemp-clay blocks is spreading to developing countries like Morocco. Investigating the hygrothermal behavior of such structures under actual climate conditions is essential for advancing and promoting this sustainable practice. This paper presents an in-depth experimental characterization of a commercial hemp-clay brick that has been exposed to the outdoor environment for four years, in addition to field measurements on a building scale demonstration prototype. Additionally, the study simulates 17 representative cities to assess the hygrothermal performance and energy-saving potential in each of Morocco's six existing climate zones, using the EnergyPlus engine. The experimental campaign's findings demonstrate excellent indoor air temperature and relative humidity regulation within the hemp-clay wall building, leading to satisfactory levels of thermal comfort within hemp-clay wall buildings. This is attributed to the material's good thermal conductivity and excellent moisture buffering capacity (found to be 0.31 W/mK and 2.25 g/m2%RH), respectively). The energy simulation findings also point to significant energy savings, with cooling and heating energy reductions ranging from 27.7% to 47.5% and 33.7% to 79.8%, respectively, as compared to traditional Moroccan buildings.
Lithium-ion batteries exhibit slow voltage dynamics on the minute time scale that are usually associated with transport processes. We present a novel modelling approach toward these dynamics by combining physical and data-driven models into a Grey-box model. We use neural networks, in particular neural ordinary differential equations. The physical structure of the Grey-box model is borrowed from the Fickian diffusion law, where the transport domain is discretized using finite volumes. Within this physical structure, unknown parameters (diffusion coefficient, diffusion length, discretization) and dependencies (state of charge, lithium concentration) are replaced by neural networks and learnable parameters. We perform model-to-model comparisons, using as training data (a) a Fickian diffusion process, (b) a Warburg element, and (c) a resistor-capacitor circuit. Voltage dynamics during constant-current operation and pulse tests as well as electrochemical impedance spectra are simulated. The slow dynamics of all three physical models in the order of ten to 30 min are well captured by the Grey-box model, demonstrating the flexibility of the present approach.
This paper presents a framework for numerical building validation enhancement based on detailed building specifications from in-situ measurements and evidence-based validation assessment undertaken on a detached sustainable lightweight building in a semi-arid climate. The validation process has been undergone in a set of controlled experiments – a free-float period, and steady-state internal temperatures. The validation was conducted for a complete year with a 1-min time step for the hourly indoor temperature and the variable refrigerant flow (VRF) energy consumption. The initial baseline model was improved by three series of validation steps per three different field measurements including thermal transmittance, glazing thermal and optical properties, and airtightness. Then, the accurate and validated model was used for building energy efficiency assessment in 12 regions of Morocco. This study aims to assess the effect of accurate building characteristics values on the numerical model enhancement. The initial CV(RMSE) and NMBE have improved respectively from 14.58 % and −11.23 %–7.85 % and 1.86 % for the indoor temperature. Besides, from 31.17 % to 14.37 %–20.57 % and 9.77 % for energy consumption. The findings demonstrate that the lightweight construction with the use of a variable refrigerant flow system could be energy efficient in the southern regions of Morocco.
Predictive control has great potential in the home energy management domain. However, such controls need reliable predictions of the system dynamics as well as energy consumption and generation, and the actual implementation in the real system is associated with many challenges. This paper presents the implementation of predictive controls for a heat pump with thermal storage in a real single-family house with a photovoltaic rooftop system. The predictive controls make use of a novel cloud camera-based short-term solar energy prediction and an intraday prediction system that includes additional data sources. In addition, machine learning methods were used to model the dynamics of the heating system and predict loads using extensive measured data. The results of the real and simulated operation will be presented.