Refine
Year of publication
Document Type
- Conference Proceeding (33) (remove)
Conference Type
- Konferenzartikel (31)
- Konferenz-Poster (1)
- Sonstiges (1)
Is part of the Bibliography
- yes (33)
Keywords
- Mikroelektronik (2)
- Thermologger (2)
- Biomedizin (1)
- Chip-Karte (1)
- Datenaufzeichnung (1)
- Datenspeicher (1)
- Hardmakros (1)
- LCA-Microcontroller (1)
- Lottozahlengenerators (1)
- Medizin (1)
- Microelectronics (1)
- Mikroprozessorkernels (1)
- Schaltkreis (1)
- Schlatungen (1)
- Systementwurf (1)
- Technik (1)
- Temperaturmessung (1)
- Temperaturverteilung (1)
- Zellbibliothek (1)
- elektronischer Würfel (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (33) (remove)
Open Access
- Bronze (21)
- Open Access (21)
- Closed (9)
- Closed Access (3)
Im ASIC Design Center der Hochschule Offenburg wird ein Design Kit für die UMC 0.18μm Faraday Technologie aufbereitet. Dabei werden alle benötigten Dateien, welche für einen zunächst rein digitalen Chipentwurf unter Verwendung der Synopsys, Cadence und Mentor Tools benötigt werden, für den UMC 0.18μm Prozess zusammengestellt.
In this paper an RFID/NFC (ISO 15693 standard) based inductively powered passive SoC (system on chip) for biomedical applications is presented. A brief overview of the system design, layout techniques and verification method is dis-cussed here. The SoC includes an integrated 32 bit microcontroller, sensor interface circuit, analog to digital converter, integrated RAM, ROM and some other peripherals required for the complete passive operation. The entire chip is realized in CMOS 0.18 μm technology with a chip area of 1.52mm x 3.24 mm.
A new RFID/NFC (ISO 15693 standard) based inductively powered passive SoC (System on chip) for biomedical applications is presented here. The proposed SOC consists of an integrated 32 bit microcontroller, RFID/NFC frontend, sensor interface circuit, analog to digital converter and some peripherals such as timer, SPI interface and memory devices. An energy harvesting unit supplies the power required for the entire system for complete passive operation. The complete chip is realized on CMOS 0.18 μm technology with a chip area of 1.5 mm × 3.0 mm.
In this paper, a complete passive transponder device has been discussed which is meant to monitor leakage in silicone breast implants. The passive tag operates in the HF frequency range of 13.56MHz using RFID ISO 15693 standard. The complete system consists of the transponder, reader and a PC. This paper focusses on the development of such a state of the art passive RFID transponder to monitor the wellness of the silicone breast implants periodically in order to detect leakage in the same. Keyword: RFID (Radio frequency identification device), EM (Electromagnetic) field, Passive Transponder, Silicone breast implants.
This paper presents an enhancement on QPSK modulation technique for near field communication (NFC). The enhanced modulation is based on continuous-phase QPSK with Gaussian filtering during switch from one phase to the other. Signal processing is done digitally with minimum external discrete components for air interface. The telemetry system can be used to assist a smart capsule (slave) that can be swallowed to establish data communication with external device (master). The system is designed, simulated, and emulated on FPGA showing 20 dB attenuation on side-lobes of the spectrum.
A new miniaturized capsule with 32bit processor and bidirectional communication system is being developed for multitask application. The capsule is designed to be a platform for medical assistant application inside the body. The processor core SIRIUS has been developed, simulated, synthesized to a netlist and verified. The designed telemetry unit is a synchronous bidirectional communication block using continuous phase DQPSK of 115 kHz low carrier frequency for inductive data transmission suited for human body energy transfer. The communication system can assist the electronic pill to trigger an actuator for drug delivery, to record temperature, or to measure pH of the body. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25 mm. The system is designed, simulated, emulated on FPGA, and routed in AMIS Technology.
Electronic pills, smart capsules or miniaturized microsystems swallowed by human beings or animals for various biomedical and diagnostic applications are growing rapidly in the last years. This paper searched out the important existing electronic pills in the market and prototypes in research centers. Further objective of this research is to develop a technology platform with enhanced feature to cover the drawback of most
capsules. The designed telemetry unit is a synchronous bidirectional communication block using continuous phase DQPSK of 115 kHz low carrier frequency for inductive data transmission suited for human body energy transfer. The communication system can assist the electronic pill to trigger an actuator for drug delivery, to record temperature, or to measure pH of the body. It consists additionally to a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA.
A new electronic capsule with bidirectional communication system is being developed for multi-task application. The capsule is designed to be a platform for medical assistant application inside the body. The designed telemetry unit is a synchronous bidirectional communication block using continuous phase DQPSK of 115 kHz low carrier frequency for inductive data transmission suited for human body energy transfer. The communication system can assist the electronic pill to trigger an actuator for drug delivery, to record temperature, or to measure pH of the body. It consists additionally to a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA. A final layout of the complete chip design is still under progress.
A new approach of continuous phase QPSK Band-Pass modulation technique is being developed as enhancement to the QPSK modulation scheme for inductive data transmission (NFC). The modulation is based on Gaussian filtering of the phase transition from one state to the other rather than discontinuity in phase shift. The carrier is based on low frequency 115 KHz suitable for human body energy penetration due to its large skin-depth and lower inductive power attenuation. The complete signal processing is done digitally, external coil and capacitor is used for transceiver interface. The telemetry assists a smart pill swallowed by human being to trigger an actuator for drug delivery, record temperature, or perform diagnostic task inside the body. The smart pill includes 32bit processor, 16 Kbyte memory, temperature sensor, telemetry unit, and additional external peripheries. The complete system is designed, embedded in one SoC, and realized on ASIC with chip-area less than 14 mm<sup>2</sup>.
An der Fachhochschule Offenburg wurde im Sept. 93 das Projekt eines implantierbaren 16 Bit Mikroprozessor-Kernels FHOP ins Leben gerufen. Ausgehend von dem in einem Testchip erfolgreich erprobten umstrukturierten Entwurf wurde durch gezielten Einsatz von strukturiertem Routen unter Nutzung der Fähigkeiten zum hierarchischen Arbeiten in der MENTOR-IC-Station eine erheblich verkleinerte und flächenmäßig optimierte Struktur abgeleitet, die sich mit 4 Quadratmilimetern Fläche durchaus mit kommerziellen Mikroprozessor-Kerneln vergleichen läßt.
FHOP-Mikroprozessor-Kernel
(1995)
A platform of an electronic capsule is being developed for multi-task medical assistant application. It includes a near field telemetry unit for bidirectional communication system of 115 KHz low carrier frequency for inductive data transmission suited for human body energy transfer. The system triggers an actuator for drug delivery in various time and release forms via wireless external control, it has the ability to record temperature, measure pH of the body (additional sensors), and retrieve data to the outside. It consists of a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA. A final layout of the complete chip design is still under progress.
A new, small, and optimized for low power processor core named SIRIUS has been developed, simulated, synthesized to a netlist and verified. From this netlist, containing only primitives like gates and flip-flops, a mapping to an ASIC - or FPGA technology can easily be done with existing synthesizer tools, allowing very complex SOC designs with several blocks. Emulation via FPGA can be done on already simple setups and cheap hardware because of the small core size. The performance is estimated 50 MIPS on Cyclone II FPGA and about 100 MIPS on a 0.35 CMOS 5M2P technology with 4197 primitives used for the core, including a 16 x 16 multiplier. An example design of the ASIC for an electronic ePille device currently in development is shown.
Im Institut für angewandte Forschung (IAF) der FH Offenburg wird derzeit eine Chipkarte entwickelt, mit der Temperaturzeitreihen über längere Zeiträume aufgezeichnet werden können. Die zur Datenerfassung erforderlichen Systemkomponenten sind auf nur einem Halbleiterchip zusammengefaßt, wodurch sich bei großen Produktionsstückzahlen ein sehr niedriger Herstellpreis erzielen läßt. Die 'Thermologger' genannte Chipkarte kann zudem mit Standard-Chipkartenlesern und einer dedizierten Software auf jedem PC konfiguriert, gelesen und ausgewertet werden.