Refine
Year of publication
Document Type
- Conference Proceeding (31) (remove)
Conference Type
- Konferenz-Poster (31) (remove)
Has Fulltext
- no (31) (remove)
Is part of the Bibliography
- yes (31)
Keywords
- 3D User Interface (1)
- 3D-Modelling (1)
- Android (1)
- Banana residues (1)
- Biogas (1)
- Biogas Potential (1)
- Biogasanlage (1)
- CST (1)
- Cardiac Resynchronization Therapy (1)
- Design Based Research (1)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (15)
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (9)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (3)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (2)
- ACI - Affective and Cognitive Institute (1)
- CRT - Campus Research & Transfer (1)
- Fakultät Wirtschaft (W) (1)
- INES - Institut für nachhaltige Energiesysteme (1)
Open Access
- Open Access (17)
- Closed Access (8)
- Bronze (6)
- Closed (5)
- Diamond (1)
Flashcards are a well known and proven method to learn and memorise. Such a way of learning is perfectly suited for “learning on the way,” but carrying all the flashcards could be awkward. In this scenario, a mobile device (mobile phone) is an adequate solution. The new mobile device operating system Android from Google allows for writing multimedia-enriched applications.
Der vorliegene Beitrag beschreibt erste Untersuchungsergebnisse mit der Finite-Elemente-Methode (FEM) zur Ermittlung der Kennwerte des bezogenen Spannungsgefälles beim linear-elastischen Werkstoffverhalten für die nach DIN 5480 genormten Zahnwellen mit freiem Auslauf bei Torsion, Biegung und Zug/Druck. Für die Bestimmung von Zwischen-werten werden analytische Näherungsgleichungen aufgestellt.
Plant oils may be used as a sustainable, nearly CO2neutral fuel for diesel engines. This work investigates experimentally the particulate and gaseous emissions of diesel engines fuelled with different non-esterified, pure plant oils. The data are collected from three engines: a) Common rail 1.7 liter passenger car engine from Opel AG b) 12.8 liter truck engine from VOLVO c) Truck engine from MAN AG.
The emissions of the MAN engine have been used to perform AMES tests to analyze possible health impacts of plant oil operation. Finally, all emission results with plant oils have been compared to traditional gas oils.
The idea of this game is to use a flashcard system to create a short story in a foreign language. The story is developed by a group of people by exchanging sentences via a flashcard system. This way, people can learn from each other without fear of making mistakes because the group members are anonymous.
Physik durch Informatik
(2022)
Selbsttests in Lernmanagementsystemen (LMS) ermöglichen es Studierenden, den eigenen Lernfortschritt einzuschätzen. Das didaktische Konzept Physik durch Informatik (PDI) ist charakterisiert durch die Nutzung einer Programmiersprache zur Lösungseingabe bei Mathematik und Physik-Aufgaben. Im Gegensatz zur Lösungseingabe durch Zahlenwerte oder im Antwort-Auswahl-Verfahren erfordert die Implementierung einer Lösung in einer Programmiersprache eine höhere Kompetenzstufe.
Micronization of biochar (BC) may ease its application in agriculture. For example, fine biochar powders can be applied as suspensions via drip-irrigation systems or can be used to produce grnulated fertilizers. However, micronization may effect important physical biochar properties like the water holding capacity (WHC) or the porosity.
A platform of an electronic capsule is being developed for multi-task medical assistant application. It includes a near field telemetry unit for bidirectional communication system of 115 KHz low carrier frequency for inductive data transmission suited for human body energy transfer. The system triggers an actuator for drug delivery in various time and release forms via wireless external control, it has the ability to record temperature, measure pH of the body (additional sensors), and retrieve data to the outside. It consists of a 32bit processor, memory, external peripheries, and detection facility. The complete system is designed to fit small-size mass medical application with low power consumption, size of 7x25mm. The system is designed, simulated and emulated on FPGA. A final layout of the complete chip design is still under progress.
This work describes a camera-based method for the calibration of optical See-Through Glasses (STGs). A new calibration technique is introduced for calibrating every single display pixel of the STGs in order to overcome the disadvantages of a parametric model. A non-parametric model compared to the parametric one has the advantage that it can also map arbitrary distortions. The new generation of STGs using waveguide-based displays [5] will have higher arbitrary distortions due to the characteristics of their optics. First tests show better accuracies than in previous works. By using cameras which are placed behind the displays of the STGs, no error prone user interaction is necessary. It is shown that a high accuracy tracking device is not necessary for a good calibration. A camera mounted rigidly on the STGs is used to find the relations between the system components. Furthermore, this work elaborates on the necessity of a second subsequent calibration step which adapts the STGs to a specific user. First tests prove the theory that this subsequent step is necessary.
Background: A disturbed synchronization of the ventricular contraction can cause a highly developed systolic heart failure in affected patients, which can often be explained by a diseased left bundle branch block (LBBB). If medication remains unresponsive, the concerned patients will be treated with a cardiac resynchronization therapy (CRT) system. The aim of this study was to integrate His bundle pacing into the Offenburg heart rhythm model in order to visualize the electrical pacing field generated by His bundle pacing.
Methods: Modelling and electrical field simulation activities were performed with the software CST (Computer Simulation Technology) from Dessault Systèms. CRT with biventricular pacing is to be achieved by an apical right ventricular electrode and an additional left ventricular electrode, which is floated into the coronary vein sinus. This conventional type of biventricular pacing leads to a reduction of the left ventricular ejection fraction. Furthermore, the non-responder rate of the CRT therapy is about one third of the CRT patients.
Results: His bundle pacing represents a physiological alternative to conventional cardiac pacing and cardiac resynchronization. An electrode implanted in the His bundle emits a stronger electrical pacing field than the electrical pacing field of conventional cardiac pacemakers. The pacing of the His bundle was performed by the Medtronic Select Secure 3830 electrode with pacing voltage amplitudes of 3 V, 2 V and 1.5 V in combination with a pacing pulse duration of 1 ms.
Conclusions: Compared to conventional cardiac pacemaker pacing, His bundle pacing is capable of bridging LBBB conduction disorders in the left ventricle. The His bundle pacing electrical field is able to spread via the physiological pathway in the right and left ventricles for CRT with a narrow QRS-complex in the surface ECG.
Heart rhythm model and simulation of electrophysiological studies and high-frequency ablations
(2017)
Background: Target of the study was to create an accurate anatomic CAD heart rhythm model, and to show its usefulness for cardiac electrophysiological studies and high-frequency ablations. The method is more careful for the patients’ health and has the potential to replace clinical studies due to its high efficiency regarding time and costs.
Methods: All natural heart components of the new HRM were based on MRI records, which guaranteed electronic functionality. The software CST was used for the construction, while CST’s material library assured genuine tissue properties. It should be applicable to simulate different heart rhythm diseases as well as various diffusions of electromagnetic fields, caused by electrophysiological conduction, inside the heart tissue.
Results: It was achievable to simulate sinus rhythm and fourteen different heart rhythm disturbance with different atrial and ventricular conduction delays. The simulated biological excitation of healthy and sick HRM were plotted by simulated electrodes of four polar right atrial catheter, six polar His bundle catheter, ten polar coronary sinus catheter, four polar ablation catheter and eight polar transesophageal left cardiac catheter. Accordingly, six variables were rebuilt and inserted into the anatomic HRM in order to establish heart catheters for ECG monitoring and HF ablation. The HF ablation catheters made it possible to simulate various types of heart rhythm disturbance ablations with different HF ablation catheters and also showed a functional visualisation of tissue heating. The use of tetrahedral meshing HRM made it attainable to store the results faster accompanied by a higher degree of space saving. The smart meshing function reduced unnecessary high resolutions for coarse structures.
Conclusions: The new HRM for EPS simulation may be additional useful for simulation of heart rhythm disturbance, cardiac pacing, HF ablation and for locating and identification of complex fractioned signals within the atrium during atrial fibrillation HF ablation.