Experimental Investigation of the Air Exchange Effectiveness of Push-Pull Ventilation Devices
(2020)
The increasing installation numbers of ventilation units in residential buildings are driven by legal objectives to improve their energy efficiency. The dimensioning of a ventilation system for nearly zero energy buildings is usually based on the air flow rate desired by the clients or requested by technical regulations. However, this does not necessarily lead to a system actually able to renew the air volume of the living space effectively. In recent years decentralised systems with an alternating operation mode and fairly good energy efficiencies entered the market and following question was raised: “Does this operation mode allow an efficient air renewal?” This question can be answered experimentally by performing a tracer gas analysis. In the presented study, a total of 15 preliminary tests are carried out in a climatic chamber representing a single room equipped with two push-pull devices. The tests include summer, winter and isothermal supply air conditions since this parameter variation is missing till now for push-pull devices. Further investigations are dedicated to the effect of thermal convection due to human heat dissipation on the room air flow. In dependence on these boundary conditions, the determined air exchange efficiency varies, lagging behind the expected range 0.5 < εa < 1 in almost all cases, indicating insufficient air exchange including short-circuiting. Local air exchange values suggest inhomogeneous air renewal depending on the distance to the indoor apertures as well as the temperature gradients between in- and outdoor. The tested measurement set-up is applicable for field measurements.
In this paper, we describe the PALM model system 6.0. PALM (formerly an abbreviation for Parallelized Large-eddy Simulation Model and now an independent name) is a Fortran-based code and has been applied for studying a variety of atmospheric and oceanic boundary layers for about 20 years. The model is optimized for use on massively parallel computer architectures. This is a follow-up paper to the PALM 4.0 model description in Maronga et al. (2015). During the last years, PALM has been significantly improved and now offers a variety of new components. In particular, much effort was made to enhance the model with components needed for applications in urban environments, like fully interactive land surface and radiation schemes, chemistry, and an indoor model. This paper serves as an overview paper of the PALM 6.0 model system and we describe its current model core. The individual components for urban applications, case studies, validation runs, and issues with suitable input data are presented and discussed in a series of companion papers in this special issue.
Cooling towers or recoolers are one of the major consumers of electricity in a HVAC plant. The implementation and analysis of advanced control methods in a practical application and its comparison with conventional controllers is necessary to establish a framework for their feasibility especially in the field of decentralised energy systems. A standard industrial controller, a PID and a model based controller were developed and tested in an experimental set-up using market-ready components. The characteristics of these controllers such as settling time, control difference, and frequency of control actions are compared based on the monitoring data. Modern controllers demonstrated clear advantages in terms of energy savings and higher accuracy and a model based controller was easier to set-up than a PID.
In this article we outline the model development planned within the joint projectModel-based city planningand application in climate change (MOSAIK). The MOSAIK project is funded by the German FederalMinistry of Education and Research (BMBF) within the frameworkUrban Climate Under Change ([UC]2)since 2016. The aim of MOSAIK is to develop a highly-efficient, modern, and high-resolution urban climatemodel that allows to be applied for building-resolving simulations of large cities such as Berlin (Germany).The new urban climate model will be based on the well-established large-eddy simulation code PALM, whichalready has numerous features related to this goal, such as an option for prescribing Cartesian obstacles. Inthis article we will outline those components that will be added or modified in the framework of MOSAIK.Moreover, we will discuss the everlasting issue of acquisition of suitable geographical information as inputdata and the underlying requirements from the model's perspective.
The transformation of the building energy sector to a highly efficient, clean, decentralised and intelligent system requires innovative technologies like microscale trigeneration and thermally activated building structures (TABS) to pave the way ahead. The combination of such technologies however presents a scientific and engineering challenge. Scientific challenge in terms of developing optimal thermo-electric load management strategies based on overall energy system analysis and an engineering challenge in terms of implementing these strategies through process planning and control. Initial literature research has pointed out the need for a multiperspective analysis in a real life laboratory environment. To this effect an investigation is proposed wherein an analytical model of a microscale trigeneration system integrated with TABS will be developed and compared with a real life test-rig corresponding to building management systems. Data from the experimental analysis will be used to develop control algorithms using model predictive control for achieving the thermal comfort of occupants in the most energy efficient and grid reactive manner. The scope of this work encompasses adsorption cooling based microscale trigeneration systems and their deployment in residential and light commercial buildings.
Microscale trigeneration systems are highly flexible in their operation and thus offer the technical possibility for peak load shifting in building demand side management. However to harness their potential modern control methods such as model predictive control must be implemented for their optimal scheduling. In literature the need for experimental investigation of microscale trigeneration systems to identify typical characteristics of the components and their interactions has been identified. On a real-life setup control specific information of the components is collected and lessons learnt during commissioning of the equipment is shared. The data is analysed to draw the vital characteristics of the system and it will be used for creating models of the components that can be utilised for optimal control.
This study presents some results from a monitoring project with night ventilation and earthto-air heat exchanger. Both techniques refer to air-based low-energy cooling. As these technologies are limited to specific boundary conditions (e.g. moderate summer climate, low temperatures during night, or low ground temperatures, respectively), water-based low-energy cooling may be preferred in many projects. A comparison of the night-ventilated building with a ground-cooled building shows major differences in both concepts.
The German Weather Service (DWD) releases a heat warning, when the weather forecast provides a warm, humid, sunny, and windless weather condition during the next days. The heat stress is calculated by the so called Klima-Michel model. If the apparent air temperature exceeds ca. 32°C / 38°C, there is a strong / extreme heat stress. The smallest forecast area is each administrative district. As people (and especially the vulnerable population) stay most of the time indoors, the heat health warning system was extended by the prediction of heat stress in typical rooms. Therewith it is feasible to forecast the heat stress using a combination of the outdoor and indoor heat stress. The prediction for the indoor heat stress is based on the same weather forecast like the Heat Health Warning Systems (HHWS).and calculates the heat stress by the PMV-model (predicted mean vote). Based on a sophisticated data analysis and simulation study, realistic but summer-critical living situations were defined and implemented in the building simulation program ESP-r. As the simulation runs especially for extreme weather conditions, a simplified building model cannot be used. Standardized input/output routines and an adaptive handover of start values provide for short run times for each forecast area. Good building designs and urban planning provide effective measures to reduce heat stress in cities. However, we have to also pay attention to the present building stock under climate change and a higher heat-wave risk. The extended German HHWS provide information for the emergency services to support the social assistants during heat waves.