Refine
Year of publication
- 2016 (19) (remove)
Document Type
- Conference Proceeding (12)
- Article (reviewed) (5)
- Letter to Editor (2)
Conference Type
- Konferenzartikel (5)
- Konferenz-Abstract (4)
- Sonstiges (3)
Language
- English (19) (remove)
Has Fulltext
- no (19) (remove)
Is part of the Bibliography
- yes (19)
Keywords
- RoboCup (3)
- Bildverarbeitung (1)
- Durchblutung (1)
- Eingebettetes System (1)
- Energieversorgung (1)
- Gehirn (1)
- Grauguss (1)
- Haaranalyse (1)
- Herzfrequenz (1)
- Humanoider Roboter (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (19) (remove)
Open Access
- Open Access (19) (remove)
This paper describes the new Sweaty II humanoid adult size robot trying to qualify for the RoboCup 2016 adult size humanoid competition. Based on experiences during RoboCup 2014, the Sweaty robot has been completely redesigned to a new robot Sweaty II. A major change is the use of linear actuators for the legs. Another characteristic is its indirect actuation by means of rods. This allows a variable transmission ratio depending on the angle of a joint.
After having described many different aspects of our team software in previous years, in this paper we take the freedom to describe the magmaChallenge framework provided by the magmaOffenburg team. The framework is used as a benchmark tool to run different challenges like the running challenge in 2014 or the kick accuracy challenge in 2015. This description should serve as a documentation to simplify the maintenance by the community and to add new benchmarks in the future.
Cardiac resynchronization therapy is an established therapy for heart failure patients. The aim of the study was to evaluate electrical left cardiac atrioventricular delay and interventricular desynchronization in sinus rhythm cardiac resynchronization therapy responder and non-responder. Cardiac electrical desynchronization were measured by surface ECG and focused transesophageal bipolar left atrial and left ventricular ECG before implantation of cardiac resynchronization therapy defibrillators. Preoperative electrical cardiac desynchronization was 195.7 ± 46.7 ms left cardiac atrioventricular delay and 74.8 ± 24.5 ms interventricular delay in cardiac resynchronization therapy responder. Cardiac resynchronization therapy responder New York Heart Association class improved during long term biventricular pacing. Transesophageal left cardiac atrioventricular delay and interventricular delay may be additional useful parameters to improve patient selection for cardiac resynchronization therapy.
A new yield function for lamellar gray cast iron materials is proposed. The new model is able to describe the results of recently performed microstructure-based finite-element computations that resolve the three dimensional yield surface of three different gray cast irons. The yield function requires only the yield stress in tension and compression of the respective material as model parameters. Furthermore, the algorithmic formulation of the new model is assessed for numerical robustness and efficiency.
Kommentar zu "Intracortical microstimulation of human somatosensory cortex" von Sharlene N. Flesher et al., veröffentlicht in Science Translational Medicine, Vol. 8, No. 361, Seite 361ra141 (DOI: 10.1126/scitranslmed.aaf8083)
eLetter zum Artikel "How hair can reveal a history" von Hanae Armitage & Nala Rogers, veröffentlicht in Science, Vol. 351, Issue 6278, Seite 1134 (doi.org/10.1126/science.351.6278.1134)
Components of rocket engines as actively cooled combustion chambers must withstand high pressure as well as severe and complex thermal transients. While the thermal transients result in temperature gradients and, thus, in constraint thermal strains, the pressure load induces mean stresses. To assess the mechanical behaviour of such components during design via finite-element calculations, constitutive models are necessary that describe the time- and temperature-dependent plasticity of the material appropriately.
Advanced models account for viscoplastic deformations including isotropic and kinematic hardening, recovery and ratcheting. However, the models contain a relatively large number of temperature-dependent material properties that must be determined on the basis of data of material tests. The determination of the properties is a non-trivial task because it is not clear which loading history must be applied in the tests for a certain material to obtain stable and robust (i.e. objective) material properties. Consequently, the determined properties are depending on the underlying loading history in the tests as well as on the experience and valuation of the person that determined the properties. This results in uncertainties during the assessment of the components that must be faced with conservative designs leading to negative consequences in terms of mass and costs.
It is the aim of this work funded by the European Space Agency ESA to derive a procedure to determine stable and robust material properties of an advanced viscoplastic constitutive model for aerospace materials. To this end, a special loading history is applied in isothermal material tests conducted with copper at different temperatures in the temperature range from 300 to 700 K. To determine the material properties and to assess stability and robustness methods for numerical optimization as well as analytical and statistical methods are used. The determined material properties are validated on the basis of results of thermomechanical material tests also conducted in the temperature range from 300 to 700 K.
The humanoid Sweaty was the finalist in this year’s robocup soccer championship(adult size). For the optimization of the gait and the stability, data concerning forces and torques in the ankle joints would be helpful. In the following paper the development of a six-axis force and torque sensor for the humanoid robot Sweaty is described. Since commercial sensors do not meet the demands for the sensors in Sweatys ankle joints, a new sensor was developed. As a measuring devices we used strain gauges and custom electronics based on an acam PS09. The geometry was analyzed with the FEM program ANSYS to get optimal dimensions for the measuring beams. In addition ANSYS was used to optimize the position for the strain gauges on the beam.
Transthoracic impedance cardiography (ICG) is a non-invasive method for determination of hemodynamic parameters. The basic principle of transthoracic ICG is the measurement of electrical conductivity of the thorax over the time. The aim of the study was the analysis of hemodynamic parameters from healthy individuals and the evaluation of various hemodynamic monitoring devices. Fourteen men (mean age 25 ± 4.59 years) and twelve women (mean age 24 ± 3.5 years) were measured during the cardiovascular engineering laboratory at Offenburg University of Applied Sciences, Offenburg, Germany. The ICG recordings were measured with the devices CardioScreen 1000, CardioScreen 2000 and TensoScreen with the corresponding Software Cardiovascular Lab 2.5 (Medis Medizinische Messtechnik GmbH, Illmenau, Germany). In order to create identical frame conditions, all measurements were recorded in the same position and for the same duration. Various positions were simulated from horizontal lying position to vertical standing position. Altogether, more than 30 hemodynamic parameters were measured.
Institute of Reliable Embedded Systems and Communication Electronics, Offenburg University of Applied Sciences, Germany has developed an automated testing environment, Automated Physical TestBeds (APTB), for analyzing the performance of wireless systems and its supporting protocols. Wireless physical networking nodes can connect to this APTB and the antenna output of this attaches with the RF waveguides. To model the RF environment this RF waveguides then establish wired connection among RF elements like splitters, attenuators and switches. In such kind of set up it’s well possible to vary the path characteristics by altering the attenuators and switches. The major advantage of using APTB is the possibility of isolated, well controlled, repeatable test environment in various conditions to run statistical analysis and even to execute regression tests. This paper provides an overview of the design and implementation of APTB, demonstrates its ability to automate test cases, and its efficiency.
Energy and environment continue to be major issues of human mankind. This holds true on the regional, the national, and the global level. And it is one of the problems, where engineers and scientists in conjunction with political will and people's awareness, can find new approaches and solutions to save the natural resources and to make their use more efficient.
In contrast to conventional aortic valve replacement, the Transcatheter Aortic Valve Implantation (TAVI) is a new highly specialist alternative to surgical valve replacement for patients with symptomatic severe aortic stenosis and high operative risk. The procedure was performed in a minimally invasive way and was introduced at the university heart centre, Freiburg – Bad Krozingen in 2008. The results have been getting better and better over the years. The aim of the investigation is the analysis of electrocardiogram conduction time and the electrocardiography changes recorded hours and days after the procedure depending on artificial heart valve models, which may lead to pacemaker implantation, even the analysis of the effectiveness of treatment.
Wireless communication systems more and more become part of our daily live. Especially with the Internet of Things (IoT) the overall connectivity increases rapidly since everyday objects become part of the global network. For this purpose several new wireless protocols have arisen, whereas 6LoWPAN (IPv6 over Low power Wireless Personal Area Networks) can be seen as one of the most important protocols within this sector. Originally designed on top of the IEEE802.15.4 standard it is a subject to various adaptions that will allow to use 6LoWPAN over different technologies; e.g. DECT Ultra Low Energy (ULE). Although this high connectivity offers a lot of new possibilities, there are several requirements and pitfalls coming along with such new systems. With an increasing number of connected devices the interoperability between different providers is one of the biggest challenges, which makes it necessary to verify the functionality and stability of the devices and the network. Therefore testing becomes one of the key components that decides on success or failure of such a system. Although there are several protocol implementations commonly available; e.g., for IoT based systems, there is still a lack of according tools and environments as well as for functional and conformance testing. This article describes the architecture and functioning of the proposed test framework based on Testing and Test Control Notation Version 3 (TTCN-3) for 6LoWPAN over ULE networks.
The ability to detect a target signal masked by noise is improved in normal-hearing listeners when interaural phase differences (IPDs) between the ear signals exist either in the masker or in the signal. To improve binaural hearing in bilaterally implanted cochlear implant (BiCI) users, a coding strategy providing the best possible access to IPD is highly desirable. In this study, we compared two coding strategies in BiCI users provided with CI systems from MED-EL (Innsbruck, Austria). The CI systems were bilaterally programmed either with the fine structure processing strategy FS4 or with the constant rate strategy high definition continuous interleaved sampling (HDCIS). Familiarization periods between 6 and 12 weeks were considered. The effect of IPD was measured in two types of experiments: (a) IPD detection thresholds with tonal signals addressing mainly one apical interaural electrode pair and (b) with speech in noise in terms of binaural speech intelligibility level differences (BILD) addressing multiple electrodes bilaterally. The results in (a) showed improved IPD detection thresholds with FS4 compared with HDCIS in four out of the seven BiCI users. In contrast, 12 BiCI users in (b) showed similar BILD with FS4 (0.6 ± 1.9 dB) and HDCIS (0.5 ± 2.0 dB). However, no correlation between results in (a) and (b) both obtained with FS4 was found. In conclusion, the degree of IPD sensitivity determined on an apical interaural electrode pair was not an indicator for BILD based on bilateral multielectrode stimulation.
BiCI users’ sensitivity to interaural phase differences for single- and multi-channel stimulation
(2016)
The ability to detect a signal masked by noise is improved in normal-hearing (NH) listeners when interaural phase differences (IPD) between the ear signals exist either in the masker or the signal. We determined the impact of different coding strategies in bilaterally implanted cochlear implant (BiCI) users with and without fine-structure coding (FSC) on masking level differences. First, binaural intelligibility level differences (BILD) were determined in NH listeners and BiCI users using their clinical speech processors. NH subjects (n=8) showed a significant mean BILD of 7.5 dB. In contrast, BiCI users (n=9) without FSC as well as with FSC revealed a barely significant mean BILD (0.4 dB respectively 0.6 dB). Second, IPD thresholds were measured in BiCI users using either their speech processors with FS4 or direct stimulation with FSC. With the latter approach, synchronized stimulation providing an interaural accuracy of stimulation timing of 1.67 µs was realized on pitch matched electrode pairs. The resulting individual IPD threshold was lower in most of the subjects with direct stimulation than with their speech processors. These outcomes indicate that some BiCI users can benefit from increased temporal precision of interaural FSC and adjusted interaural frequency-place mapping presumably resulting in improved BILD.