Refine
Year of publication
- 2017 (76) (remove)
Document Type
- Conference Proceeding (36)
- Article (reviewed) (17)
- Letter to Editor (6)
- Article (unreviewed) (6)
- Contribution to a Periodical (4)
- Book (3)
- Part of a Book (2)
- Patent (1)
- Report (1)
Conference Type
- Konferenzartikel (21)
- Konferenz-Abstract (10)
- Sonstiges (3)
- Konferenz-Poster (2)
Has Fulltext
- no (76) (remove)
Is part of the Bibliography
- yes (76)
Keywords
- CST (7)
- HF-Ablation (7)
- CRT (5)
- Götz von Berlichingen (3)
- RoboCup (3)
- IVD (2)
- Aktivierung (1)
- Anti-Windup-Maßnahmen (1)
- Beamforming (1)
- Beobachter (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (76) (remove)
Open Access
- Closed Access (35)
- Open Access (29)
- Bronze (3)
- Closed (3)
Im Jahr 1504 verlor der deutsche Ritter Gottfried („Götz“) von Berlichingen seine
rechte Hand. Schon während seiner Genesung dachte er daran, die Hand zu ersetzen,
und beauftragte bald darauf die erste Handprothese, die sogenannte „Eiserne Hand“.
Jahre später wurde die aufwändigere zweite „Eiserne Hand“ gebaut. Wir haben die erste
Prothese auf der Basis früherer Literaturdaten von
Quasigroch (1982) mit Hilfe von 3-D
Computer-Aided Design (CAD) rekonstruiert. Dazu mussten einige Abmessungen angepasst
und ein paar Annahmen für das CAD-Modell gemacht werden. Die historische passive
Prothese des Götz von Berlichingen ist für die moderne Neuroprothetik interessant, da sie
eine Alternative zu komplexen invasiven Brain-Machine-Interface-Konzepten darstellen
könnte, wo diese Konzepte nicht notwendig, möglich oder vom Patienten gewünscht sind.
In this study, we tested the function of a replica of the over 500-year-old original of the
famous Franconian Imperial Knight Götz von Berlichingen’s first “iron hand”, which we
reconstructed by computer-aided design (CAD) and recently printed using a multi-material
3D printer. In different everyday tasks, the artificial hand prosthesis proved to be remarkably
helpful. Thus, the hand could hold a wine glass, some grapes, or a smartphone. With a
suitable pencil, even writing was possible without any problem. Although for all these
functions the healthy other hand was necessary to assist at the beginning, the artificial hand
is an astonishing mechanical aid with many possibilities. Therefore, in certain cases, the
non-invasive approach of a passive mechanical hand replacement, which is an individual,
quick and cheap solution due to modern 3D printing, may always be worth considering
also for today’s requirements.
A novel approach of a testbed for embedded networking nodes has been conceptualized and implemented. It is based on the use of virtual nodes in a PC environment, where each node executes the original embedded code. Different nodes are running in parallel and are connected via so-called virtual interfaces. The presented approach is very efficient and allows a simple description of test cases without the need of a network simulator. Furthermore, it speeds up the process of developing new features.
With increasing flexible AC transmission system (FACTS) devices in operation, like the most versatile unified power flow controller (UPFC), the AC/DC transmission flexibility and power system stability have been suffering unprecedented challenge. This paper introduces the user-defined modeling (UDM) method into the UPFC dynamic modeling process, to deal with the challenging requirements of power system operation. This has also been verified using a leading-edge stability analysis software named DSATools TM in the IEEE-39 bus benchmark system. The characteristics of steady-state and dynamic responses are compared and analyzed under different conditions. Furthermore, simulation results prove the feasibility and effectiveness of the proposed UPFC in terms of both the independent regulation of power flow and the improvement of transient stability.
Am Buffet des Lebens
(2017)
Cellular phone antennas are generally designed to have radiation patterns that are as omnidirectional as possible. Omnidirectional antennas allow a phone’s radio to work well for many orientations of the phone with respect to the cellular base station. Recent studies, however, are generating uncertainty about the health effects of prolonged exposure to electromagnetic (EM) radiation from cellular phones. In this paper, an antenna array is designed primarily to minimize users’ exposure to EM radiation. The antenna comprises a beamforming 4 by 3 array of microstrip patch antennas that is controlled by an accelerometer-only inertial navigation system. The proposed design reduces radiated power directed toward the user to below 10% of the total in the worst case.
Das normalhörende auditorische System ist in der Lage, interaurale Zeit- bzw. Phasendifferenzen zur verbesserten Signaldetektion im Störgeräusch zu nutzen. Dieses Phänomen wird häufig als binaurale Entmaskierung bezeichnet und ist sowohl bei einfachen Signalen wie Sinustönen, als auch bei Sprachsignalen im Störgeräusch wirksam. Vorangegangene Studien haben gezeigt, dass binaurale Entmaskierung eingeschränkt auch bei bilateralen CI-Trägern beobachtbar ist (Zirn et al., 2016).
Aktuelle Ergebnisse zeigen, dass die binaurale Entmaskierung sensitiv gegenüber der bilateralen CI-Anpassung ist. So lässt sich der Effekt durch tonotopen Abgleich und Herausstellen eines apikalen Feinstrukturkanals modulieren. Steigerungen der binauralen Entmaskierung um bis zu 1,5 dB sind auf diese Weise gegenüber der konventionellen CI-Anpassung möglich. Allerdings variiert der Einfluss der CI-Anpassung interindividuell erheblich.
Comparison of Time Warping Algorithms for Rail Vehicle Velocity Estimation in Low Speed Scenarios
(2017)
Objectives: Speech recognition on the telephone poses a challenge for patients with cochlear implants (CIs) due to a reduced bandwidth of transmission. This trial evaluates a home-based auditory training with telephone-specific filtered speech material to improve sentence recognition. Design: Randomised controlled parallel double-blind. Setting: One tertiary referral centre. Participants: A total of 20 postlingually deafened patients with CIs. Main outcome measures: Primary outcome measure was sentence recognition assessed by a modified version of the Oldenburg Sentence Test filtered to the telephone bandwidth of 0.3-3.4 kHz. Additionally, pure tone thresholds, recognition of monosyllables and subjective hearing benefit were acquired at two separate visits before and after a home-based training period of 10-14 weeks. For training, patients received a CD with speech material, either unmodified for the unfiltered training group or filtered to the telephone bandwidth in the filtered group. Results: Patients in the unfiltered training group achieved an average sentence recognition score of 70.0%±13.6% (mean±SD) before and 73.6%±16.5% after training. Patients in the filtered training group achieved 70.7%±13.8% and 78.9%±7.0%, a statistically significant difference (P=.034, t10 =2.292; two-way RM ANOVA/Bonferroni). An increase in the recognition of monosyllabic words was noted in both groups. The subjective benefit was positive for filtered and negative for unfiltered training. Conclusions: Auditory training with specifically filtered speech material provided an improvement in sentence recognition on the telephone compared to training with unfiltered material.
Die Entwicklung von neuartigen Elektrodentypen und die Weiterentwicklung bestehender Produkten machen einen großen Teil der entstehenden Kosten für ein Unternehmen aus. Mithilfe geeigneter Software können Änderungen der Konstruktionen erfasst und bestimmte Simulationen, bspw. das Auftreten von Wechselwirkungen im elektrischen Feld, vor der eigentlichen Prototypenerstellung durchgeführt werden. Das Ziel der Studie besteht in der Modellierung unterschiedlicher Schrittmacher- und Ablationselektroden und deren Integration in das Offenburger Herzrhythmusmodell (HRM) zur statischen und dynamischen Simulation der biventrikulären Stimulation und HF Ablation bei Vorhofflimmern (AF).
Electrolyte-Gated Field-Effect Transistors Based on Oxide Semiconductors: Fabrication and Modeling
(2017)
Hintergrund: Das elektrische interventrikuläre Delay (IVD) ist bei Patienten (P) mit Herzinsuffizienz (HF), reduzierter linksventrikulärer (LV) Funktion und verbreitertem QRS Komplex von Bedeutung für den Erfolg der kardialen Resynchronisationstherapie (CRT). Die transösophageale LV Elektrokardiographie (EKG) ermöglicht die Bestimmung des elektrischen IVD und linksventrikulären Delays (LVD). Das Ziel der Studie besteht in der Untersuchung des transösophagealen elektrischen IVD, LVD und deren Verhältnis zur QRS Dauer bei rechtsventrikulärer (RV) Stimulation vor Aufrüstung auf eine biventrikuläre (BV) Stimulation.
Methoden: Bei 11 HF P (Alter 69,0 ± 7,9 Jahre; 10 Männer und 1 Frau) mit DDD Schrittmacher (n=10), DDD Defibrillator (n=1) und RV Stimulation, New York Heart Association (NYHA) Klasse 3,0 ± 0,2, LV Ejektionsfraktion 24,5 ± 4,9 % und QRS-Dauer 228,2 ± 44,8 ms wurden das elektrische IVD als Intervall zwischen Beginn des QRS-Komplexes im Oberflächen EKG und Beginn des LV Signals im transösophagealen LV EKG und das elektrische LVD als Intervall zwischen Beginn und Ende des LV Signals im transösophagealen LV EKG präoperativ vor Aufrüstung auf CRT Defibrillator (n=8) und CRT Schrittmacher (n=3) bestimmt. Der Anstieg des arteriellen Pulse Pressure (PP) wurde zwischen RV Stimulation und transösophagealer LV Stimulation mit unterschiedlichem AV-Delay (n=5) vor Aufrüstung von RV auf BV Stimulation getestet.
Ergebnisse: Bei RV Stimulation betrugen IVD 86,54 ± 32,80 ms, LVD 94,45 ± 23,80 ms, QRS-IVD-Verhältnis 2,63 ± 0,81 mit negativer Korrelation zwischen IVD und QRS-IVD-Verhältnis (r=-0,668 P=0,0248) (Fig.) und QRS-LVD-Verhältnis 2,33 ± 0,73. Vorhofsynchrone ventrikuläre Stimulation führte zu 63,6 ± 27,7 mmHg PP bei RV Stimulation und 80,6 ± 38,5 mmHg PP bei LV Stimulation und der PP erhöhte sich bei LV Stimulation mit optimalem AV Delay um 17 ± 11,2 mmHg gegenüber RV Stimulation (P<0,001). Nach Aufrüstung von RV Stimulation auf BV Stimulation verbesserten sich die NYHA Klasse von 3,1 ± 0,2 auf 2,2 ± 0,3 während 30,4 ± 29,6 Monaten CRT.
Schlussfolgerungen: Das transösophageale LV EKG ermöglicht die Bestimmung des elektrischen IVD und LVD bei RV Stimulation zur Evaluierung der interventrikulären und linksventrikulären elektrischen Desynchronisation. IVD, LVD und deren Verhältnis zur QRS Dauer können möglicherweise zur Vorhersage einer CRT Response vor Aufrüstung von RV auf BV Stimulation genutzt werden.
eLetter zum Artikel "How hair can reveal a history" von Hanae Armitage & Nala Rogers, veröffentlicht in Science, Vol. 351, Issue 6278, Seite 1134 (doi.org/10.1126/science.351.6278.1134)
Due to climate change and scarcity of water reservoirs, monitoring and control of irrigation systems is now becoming a major focal area for researchers in Cyber-Physical Systems (CPS). Wireless Sensor Networks (WSNs) are rapidly finding their way in the field of irrigation and play the key role as data gathering technology in the domain of IoT and CPS. They are efficient for reliable monitoring, giving farmers an edge to take precautionary measures. However, designing an energy-efficient WSN system requires a cross-layer effort and energy-aware routing protocols play a vital role in the overall energy optimization of a WSN. In this paper, we propose a new hierarchical routing protocol suitable for large area environmental monitoring such as large-scale irrigation network existing in the Punjab province of Pakistan. The proposed protocol resolves the issues faced by traditional multi-hop routing protocols such as LEACH, M-LEACH and I-LEACH, and enhances the lifespan of each WSN node that results in an increased lifespan of the whole network. We used the open-source NS3 simulator for simulation purposes and results indicate that our proposed modifications result in an average 27.8% increase in lifespan of the overall WSN when compared to the existing protocols.
Die drei großen Hersteller von Cochlea-Implantat (CI)-Systemen ermöglichen es klinischen Audiologen, die Mikrofoneigenschaften der meisten CI-Sprachprozessoren zu prüfen. Dazu können bei diesen Sprachprozessoren Monitorkopfhörer angeschlossen und das/die Mikrofon(e) inklusive eines Teils der Signalvorverarbeitung abgehört werden. Präzise Angaben dazu, mit welchen Stimuli, bei welchem Pegel und nach welchem Kriterium diese Prüfung stattfinden soll, machen die CI-Hersteller nicht. Auf Basis dieser Prüfung soll der Audiologe dann über die Funktion der Mikrofone und damit darüber entscheiden, ob der betreffende Sprachprozessor an den Hersteller eingeschickt wird oder nicht.
Zur Objektivierung der CI-Sprachprozessor-Mikrofon-Prüfung haben wir eine Testbox entwickelt, mit der alle abhörbaren aktuellen CI-Sprachprozessoren der drei großen Hersteller geprüft werden können. Die Box wurde im 3D-Druck-Verfahren hergestellt. Der zu prüfende Sprachprozessor wird in die Messbox eingehängt und über einen darin verbauten Lautsprecher mit definierten Prüfsignalen (Sinustöne unterschiedlicher Frequenz) beschallt. Das Mikrofonsignal wird über das Kabel der Monitorkopfhörer herausgeführt und mit einer Shifting- and Scaling-Schaltung in einen Spannungsbereich transformiert, der für die AD-Wandlung mit einem Mikrokontroller (ATmega1280 verbaut auf einem Arduino Mega) geeignet ist. Derselbe Mikrokontroller übernimmt über einen eigens gebauten DA-Wandler die Ausgabe der Sinustöne über den Lautsprecher. Signalaufnahme und –wiedergabe erfolgen mit jeweils 38,5 kHz Samplingrate. Der für jede Frequenz über mehrere Perioden des Prüfsignals ermittelte Effektivwert wird mit dem Effektivwert, der mit einem neuwertigen Referenzprozessor für diese Frequenz gemessen wurde, verglichen. Die Messergebnisse werden graphisch auf einem Display ausgegeben.
Derzeit läuft eine erste Datenerhebung mit in der Klinik subjektiv auffällig gewordenen CI-Sprachprozessoren, die anschließend in der Messbox untersucht werden. So sollen realistische Schwellen für kritische Abweichungen von den Referenz-Effektivwerten ermittelt werden. Im weiteren Verlauf sollen dann Hit und False Alarm-Raten der subjektiven Prüfung bestimmt werden.
Für die genaue Positionsbestimmung in Innenräumen, beispielsweise in Bahnhöfen oder Einkaufszentren, soll in dem beschriebenen Projekt untersucht werden, inwiefern lokale Magnetfelder genutzt werden können, um Genauigkeit und Robustheit zu erhöhen. Hierzu wird untersucht, ob und wie kostengünstige Magnetfeldsensoren und mobile Roboterplattformen genutzt werden können, um Karten zu erstellen, die eine spätere Navigation, beispielsweise mit Smartphones oder mit anderen mobilen Geräten.
eTPL: An Enhanced Version of the TLS Presentation Language Suitable for Automated Parser Generation
(2017)
The specification of the Transport Layer Security (TLS) protocol defines its own presentation language used for the purpose of semi-formally describing the structure and on-the-wire format of TLS protocol messages. This TLS Presentation Language (TPL) is more expressive and concise than natural language or tabular descriptions, but as a result of its limited objective has a number of deficiencies. We present eTPL, an enhanced version of TPL that improves its expressiveness, flexibility, and applicability to non-TLS scenarios. We first define a generic model that describes the parsing of binary data. Based on this, we propose language constructs for TPL that capture important information which would otherwise have to be picked manually from informal protocol descriptions. Finally, we briefly introduce our software tool etpl-tool which reads eTPL definitions and automatically generates corresponding message parsers in C++. We see our work as a contribution supporting sniffing, debugging, and rapid-prototyping of wired and wireless communication systems.
Exploiting Dissent: Towards Fuzzing-based Differential Black Box Testing of TLS Implementations
(2017)
The Transport Layer Security (TLS) protocol is one of the most widely used security protocols on the internet. Yet do implementations of TLS keep on suffering from bugs and security vulnerabilities. In large part is this due to the protocol's complexity which makes implementing and testing TLS notoriously difficult. In this paper, we present our work on using differential testing as effective means to detect issues in black-box implementations of the TLS handshake protocol. We introduce a novel fuzzing algorithm for generating large and diverse corpuses of mostly-valid TLS handshake messages. Stimulating TLS servers when expecting a ClientHello message, we find messages generated with our algorithm to induce more response discrepancies and to achieve a higher code coverage than those generated with American Fuzzy Lop, TLS-Attacker, or NEZHA. In particular, we apply our approach to OpenssL, BoringSSL, WolfSSL, mbedTLS, and MatrixSSL, and find several real implementation bugs; among them a serious vulnerability in MatrixSSL 3.8.4. Besides do our findings point to imprecision in the TLS specification. We see our approach as present in this paper as the first step towards fully interactive differential testing of black-box TLS protocol implementations. Our software tools are publicly available as open source projects.
The paper describes the hardware and software architecture of the developed multi MEMS sensor prototype module, consisting of ARM Cortex M4 STM32F446 microcontroller unit, five 9-axis inertial measurement units MPU9255 (3D accelerometer, 3D gyroscope, 3D magnetometer and temperature sensor) and a BMP280 barometer. The module is also equipped with WiFi wireless interface (Espressif ESP8266 chip). The module is constructed in the form of a truncated pyramid. Inertial sensors are mounted on a special basement at different angles to each other to eliminate hardware sensors drifts and to provide the capability for self-calibration. The module fuses information obtained from all types of inertial sensors (acceleration, rotation rate, magnetic field and air pressure) in order to calculate orientation and trajectory. It might be used as an Inertial Measurement Unit, Vertical Reference Unit or Attitude and Heading Reference System.
Heart rhythm model and simulation of electrophysiological studies and high-frequency ablations
(2017)
Background: Target of the study was to create an accurate anatomic CAD heart rhythm model, and to show its usefulness for cardiac electrophysiological studies and high-frequency ablations. The method is more careful for the patients’ health and has the potential to replace clinical studies due to its high efficiency regarding time and costs.
Methods: All natural heart components of the new HRM were based on MRI records, which guaranteed electronic functionality. The software CST was used for the construction, while CST’s material library assured genuine tissue properties. It should be applicable to simulate different heart rhythm diseases as well as various diffusions of electromagnetic fields, caused by electrophysiological conduction, inside the heart tissue.
Results: It was achievable to simulate sinus rhythm and fourteen different heart rhythm disturbance with different atrial and ventricular conduction delays. The simulated biological excitation of healthy and sick HRM were plotted by simulated electrodes of four polar right atrial catheter, six polar His bundle catheter, ten polar coronary sinus catheter, four polar ablation catheter and eight polar transesophageal left cardiac catheter. Accordingly, six variables were rebuilt and inserted into the anatomic HRM in order to establish heart catheters for ECG monitoring and HF ablation. The HF ablation catheters made it possible to simulate various types of heart rhythm disturbance ablations with different HF ablation catheters and also showed a functional visualisation of tissue heating. The use of tetrahedral meshing HRM made it attainable to store the results faster accompanied by a higher degree of space saving. The smart meshing function reduced unnecessary high resolutions for coarse structures.
Conclusions: The new HRM for EPS simulation may be additional useful for simulation of heart rhythm disturbance, cardiac pacing, HF ablation and for locating and identification of complex fractioned signals within the atrium during atrial fibrillation HF ablation.
Heart rhythm model and simulation of electrophysiological studies and high-frequency ablations
(2017)
Background: The simulation of complex cardiologic structures has the potential to replace clinical studies due to its high efficiency regarding time and costs. Furthermore, the method is more careful for the patients’ health than the conventional ways. The aim of the study was to create an anatomic CAD heart rhythm model (HRM) as accurate as possible, and to show its usefulness for cardiac electrophysiological studies (EPS) and high-frequency (HF) ablations.
Methods: All natural heart components of the new HRM were based on MRI records, which guaranteed electronic functionality. The software CST (Computer Simulation Technology, Darmstadt) was used for the construction, while CST’s material library assured genuine tissue properties. It should be applicable to simulate different heart rhythm diseases as well as various diffusions of electromagnetic fields, caused by electrophysiological conduction, inside the heart tissue.
Results: It was achievable to simulate normal sinus rhythm and fourteen different heart rhythm disturbance with different atrial and ventricular conduction delays. The simulated biological excitation of healthy and sick HRM were plotted by simulated electrodes of four polar right atrial catheter, six polar His bundle catheter, ten polar coronary sinus catheter, four polar ablation catheter and eight polar transesophageal left cardiac catheter (Fig.). Accordingly, six variables were rebuilt and inserted into the anatomic HRM in order to establish heart catheters for ECG monitoring and HF ablation. The HF ablation catheters made it possible to simulate various types of heart rhythm disturbance ablations with different HF ablation catheters and also showed a functional visualisation of tissue heating. The use of tetrahedral meshing HRM made it attainable to store the results faster accompanied by a higher degree of space saving. The smart meshing function reduced unnecessary high resolutions for coarse structures.
Conclusions: The new HRM for EPS simulation may be additional useful for simulation of heart rhythm disturbance, cardiac pacing, HF ablation and for locating and identification of complex fractioned signals within the atrium during atrial fibrillation HF ablation.
Heart rhythm model and simulation of electrophysiological studies and high-frequency ablations
(2017)
Background: The simulation of complex cardiologic structures has the potential to replace clinical studies due to its high efficiency regarding time and costs. Furthermore, the method is more careful for the patients’ health than the conventional ways. The aim of the study was to create an anatomic CAD heart rhythm model (HRM) as accurate as possible, and to show its usefulness for cardiac electrophysiological studies (EPS) and high-frequency (HF) ablations.
Methods: All natural heart components of the new HRM were based on MRI records, which guaranteed electronic functionality. The software CST (Computer Simulation Technology, Darmstadt) was used for the construction, while CST’s material library assured genuine tissue properties. It should be applicable to simulate different heart rhythm diseases as well as various diffusions of electromagnetic fields, caused by electrophysiological conduction, inside the heart tissue.
Results: It was achievable to simulate normal sinus rhythm and fourteen different heart rhythm disturbance with different atrial and ventricular conduction delays. The simulated biological excitation of healthy and sick HRM were plotted by simulated electrodes of four polar right atrial catheter, six polar His bundle catheter, ten polar coronary sinus catheter, four polar ablation catheter and eight polar transesophageal left cardiac catheter (Fig.). Accordingly, six variables were rebuilt and inserted into the anatomic HRM in order to establish heart catheters for ECG monitoring and HF ablation. The HF ablation catheters made it possible to simulate various types of heart rhythm disturbance ablations with different HF ablation catheters and also showed a functional visualisation of tissue heating. The use of tetrahedral meshing HRM made it attainable to store the results faster accompanied by a higher degree of space saving. The smart meshing function reduced unnecessary high resolutions for coarse structures.
Conclusions: The new HRM for EPS simulation may be additional useful for simulation of heart rhythm disturbance, cardiac pacing, HF ablation and for locating and identification of complex fractioned signals within the atrium during atrial fibrillation HF ablation.
Die Simulation komplexer kardialer Strukturen und kardialer Elektroden ist von Bedeutung für die Optimierung langatmiger und kostspieliger klinischer Studien. Das Risiko der Patientengefährdung wird durch diese Methode auf ein Minimum reduziert. Das Ziel der Studie besteht im Entwurf eines anatomisch korrekten 3D CAD Herzrhythmusmodells (HRM) zur Simulation von elektrophysiologischen Untersuchungen (EPU) und Hochfrequenz-(HF-)Ablationen.
In this study, a high-performance controller is proposed for single-phase grid-tied energy storage systems (ESSs). To control power factor and current harmonics and manage time-shifting of energy, the ESS is required to have low steady-state error and fast transient response. It is well known that fast controllers often lack the required steady-state accuracy and trade-off is inevitable. A hybrid control system is therefore presented that combines a simple yet fast proportional derivative controller with a repetitive controller which is a type of learning controller with small steady-state error, suitable for applications with periodic grid current harmonic waveforms. This results in an improved system with distortion-free, high power factor grid current. The proposed controller model is developed and design parameters are presented. The stability analysis for the proposed system is provided and the theoretical analysis is verified through stability, transient and steady-state simulations.
Dieses Buch beschreibt die regelungstechnische Modellbildung und die darauf basierende Regelung der gebräuchlichsten, in industriellen Anwendungen eingesetzten elektrischen Maschinen.
Hinsichtlich des Reglerentwurfs wird eine sehr leistungsfähige Methodik angewendet, mit der alle analysierten Beispiele einheitlich behandelt werden können. Sie basiert auf der zeitdiskreten Zustandsraumbeschreibung stromrichtergespeister elektrischer Antriebe. Durch die leicht verständliche einführende Beschreibung der Methodik wird es auch Lesern, denen die Zustandsraummethodik nicht geläufig ist, möglich, dynamisch sehr hochwertige Regelungen zu implementieren.
Eine weitere Besonderheit ist die Einbeziehung von rückspeisefähigen Netzstromrichtern in die Betrachtungen.
Neben einigen Umgestaltungen und Erweiterungen wurden für die Neuauflage auch zahlreiche interessante Ergänzungen vorgenommen, etwa hinsichtlich Rückschlussmöglichkeiten aus Typenschildangaben einer Drehstrommaschine auf die in den zugehörigen Differentialgleichungen verwendeten Maschinenparameter sowie auf Möglichkeiten zu deren Identifikation im Betrieb.
The ability to detect a target signal masked by noise is improved in normal-hearing listeners when interaural phase differences (IPDs) between the ear signals exist either in the masker or in the signal. To improve binaural hearing in bilaterally implanted cochlear implant (BiCI) users, a coding strategy providing the best possible access to IPDs is highly desirable. Outcomes of a previous study (Zirn, Arndt et al. 2016) revealed that a subset of BiCI users showed improved IPD detection thresholds with the fine structure processing strategy FS4 compared to the constant rate strategy HDCIS using narrowband stimuli. In contrast, little differences between the coding strategies were found for broadband stimuli with regard to binaural speech intelligibility level differences (BILD) as an estimate of binaural unmasking. Compared to normalhearing listeners (7.5 ± 1.2 dB) BILD were small in BiCI users (around 0.5 dB with both coding strategies).
In the present work, we investigated the influence of binaural fitting parameters on BILD. In our cohort of BiCI users many were implanted with electrode arrays differing in length left versus right. Because this length difference typically corresponded to the distance of two electrode contacts the first modification of bilateral fitting was a tonotopic adjustment by deactivation of the most apical electrode contact on the side with the deeper inserted array (tonotopic approach).
The second modification was the isolation of the residual, most apical electrode contacts by deactivation of the basally adjacent electrode contact on each side (tonotopic sparse approach). Applying these modifications, BILD improved by up to 1.5 dB.
Background: Cardiac resynchronization therapy (CRT) with biventricular (BV) pacing is an established therapy for heart failure (HF) patients (P) with sinus rhythm, reduced left ventricular (LV) ejection fraction (EF) and electrical ventricular desynchronization. The aim of the study was to evaluate electrical interventricular delay (IVD) and left ventricular delay (LVD) in right ventricular (RV) pacemaker pacing before upgrading to CRT BV pacing.
Methods: HF P (n=11, age 69.0 ± 7.9 years, 1 female, 10 males) with DDD pacemaker (n=10), DDD defibrillator (n=1), RV pacing, New York Heart Association (NYHA) class 3.0 ± 0.2 and 24.5 ± 4.9 % LVEF were measured by surface ECG and transesophageal bipolar LV ECG before upgrading to CRT defibrillator (n=8) and CRT pacemaker (n=3). IVD was measured between onset of QRS in the surface ECG and onset of LV signal in the transesophageal ECG. LVD was measured between onset and offset of LV signal in the transesophageal ECG. CRT atrioventricular (AV) and BV pacing delay were optimized by impedance cardiography.
Results: Interventricular and intraventricular desynchronization in RV pacemaker pacing were 228.2 ± 44.8 ms QRS duration, 86.5 ± 32.8ms IVD, 94.4 ± 23.8ms LVD, 2.6 ± 0.8 QRS-IVD-ratio with correlation between IVD and QRS-IVD-ratio (r=-0.668 P=0.0248) and 2.3 ± 0.7 QRS-LVD-ratio. The LVEF-IVD-ratio was 0.3 ± 0.1 with correlation between IVD and LVEF-IVD-ratio (r=-0.8063 P=0.00272) and with correlation between QRS duration and LVEF-IVD-ratio (r=-0.7251 P=0.01157). Optimal sensing and pacing AV delay were 128.3 ± 24.8 ms AV delay after atrial sensing (n=6) and 173.3 ± 40.4 ms AV delay after atrial pacing (n=3). Optimal BV pacing delay was -4.3 ± 11.3 ms between LV and RV pacing (n=7). During 30.4 ± 29.6 month CRT follow-up, the NYHA class improved from 3.1 ± 0.2 to 2.2 ± 0.3.
Conclusions: Transesophageal electrical IVD and LVD in RV pacemaker pacing may be additional useful ventricular desynchronization parameters to improve P selection for upgrading RV pacemaker pacing to CRT BV pacing.
The Bluetooth community is in the process to develop mesh technology. This is highly promising as Bluetooth is widely available in Smart Phones and Tablet PCs, allowing an easy access to the Internet of Things. In this paper work, we investigate the performance of Bluetooth enabled mesh networking that we performed to identify the strengths and weaknesses. A demonstrator for this protocol has been implemented by using the Fruity Mesh protocol implementation. Extensive test cases have been executed to measure the performance, the reliability, the power consumption and the delay. For this, an Automated Physical Testbed (APTB), which emulates the physical channels has been used. The results of these measurements are considered useful for the real implementation of Bluetooth; not only for home and building automation, but also for industrial automation.
In this paper we show that a model-free approach to learn behaviors in joint space can be successfully used to utilize toes of a humanoid robot. Keeping the approach model-free makes it applicable to any kind of humanoid robot, or robot in general. Here we focus on the benefit on robots with toes which is otherwise more difficult to exploit. The task has been to learn different kick behaviors on simulated Nao robots with toes in the RoboCup 3D soccer simulator. As a result, the robot learned to step on its toe for a kick that performs 30% better than learning the same kick without toes.
The low cost and small size of MEMS inertial sensors allows their combination into a multi sensor module in order to improve performance. However the different linear accelerations measured on different places on a rotating rigid body have to be considered for the proper fusion of the measurements. The errors in measurement of MEMS inertial sensors include deterministic imperfection, but also random noise. The gain in accuracy of using multiple sensors depends strongly on the correlation between these errors from the different sensors. Although for sensor fusion it usually assumed that the measurement errors of different sensors are uncorrelated, estimation theory shows that for the combination of the same type of sensors actually a negative correlation will be more beneficial. Therefore we describe some important and often neglected considerations for the combination of several sensors and also present some preliminary results with regard to the correlation of measurements from a simple multi sensor setup.
Message co chairmen
(2017)
Musik und Neurophysiologie
(2017)
Nicht-invasives, nicht-ionisierendes funktionelles Neuroimaging mit räumlich und zeitlich hochauflösender Elektroenzephalographie oder Echtzeit-Naheinfrarotspektroskopie in Kombination mit modernen Robotorsystemen ist ein entscheidender Entwicklungsschritt auf dem Gebiet der Neuroprothetik und Brain-Machine-Interfaces. In der Medizintechnik an der Hochschule Offenburg wird hierzu geforscht.
eLetter zum Artikel "Hybrid EEG/EOG-based brain/neural hand exoskeleton restores fully independent daily living activities after quadriplegia" von Surjo R. Soekadar et al., veröffentlicht in Science Robotics, Vol. 1, No. 1 (DOI: 10.1126/scirobotics.aag3296)
In this paper we present the implementation of a model-predictive controller (MPC) for real-time control of a cable-robot-based motion simulator. The controller computes control inputs such that a desired acceleration and angular velocity at a defined point in simulator’s cabin are tracked while satisfying constraints imposed by working space and allowed cable forces of the robot. In order to fully use the simulator capabilities, we propose an approach that includes the motion platform actuation in the MPC model. The tracking performance and computation time of the algorithm are investigated in computer simulations. Furthermore, for motion simulation scenarios where the reference trajectories are not known beforehand, we derive an estimate on how much motion simulation fidelity can maximally be improved by any reference prediction scheme compared to the case when no prediction scheme is applied.