Refine
Year of publication
- 2021 (3) (remove)
Document Type
- Doctoral Thesis (3) (remove)
Has Fulltext
- no (3) (remove)
Is part of the Bibliography
- yes (3)
Keywords
- Ablationstherapie (1)
- Defibrillatortherapie (1)
- Didaktik (1)
- Elektrotherapie (1)
- Evaluation (1)
- Herzfehler (1)
- Herzschrittmachertherapie (1)
- Implantat (1)
- Lehrmittel (1)
- Okkluder (1)
Institute
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (3) (remove)
Open Access
- Open Access (3)
Herzfehler sind weltweit die häufigste Form von angeborenen Organdefekten. In unterschiedlichen Studien wird die Inzidenz zumeist zwischen vier und elf von 1.000 Lebendgeburten angegeben (1–5). Im Rahmen der multizentrischen PAN-Studie (PAN: Prävalenz angeborener Herzfehler bei Neugeborenen), welche die Häufigkeit angeborener Herzfehler bei Neugeborenen in Deutschland zwischen Juli 2006 und Juni 2007 untersuchte, ergab sich eine Gesamtprävalenz von 107,6 pro 10.000 Lebendgeburten. Gegenstand dieser Arbeit sind Untersuchungen an Implantaten zur Behandlung von Atriumseptumdefekten (ASD). Vorhofseptumdefekte machen mit 17,0%, nach den Ventrikelseptumdefekten (VSD) mit 48,9%die zweithäufigste Art von Herzfehlern aus (6, 7).Als Vorhofseptumdefekte werden Öffnungen in der Scheidewand zwischen den Herzvorhöfen bezeichnet. Bei der Therapie eines ASD ist der minimalinvasive Verschluss mittels sogenannter Okkluder heute das Mittel der Wahl. Diese werden über einen femoralen Zugang im Rahmen einer Herzkatheteruntersuchung unter Ultraschallkontrolle und Durchleuchtung an die Implantationsstelle vorgeschoben und dort platziert(8). Die Okkluder bestehen in der Regel aus einem Drahtgeflecht aus Nitinol und haben die typische Form eines sogenannten Doppelschirmchens. Dabei weichen die unterschiedlichen Okkluder der einzelnen Firmen hinsichtlich Form und Beschaffenheit oft erheblich voneinander ab. Derzeit gibt es keine Untersuchungsmethode, die die auf dem Markt befindlichen Okkluder hinsichtlich ihrer mechanischen Eigenschaften vergleichbar macht. Diese Arbeit solleinen Beitrag erbringen, um grundlegende, die Okkludermodelle charakterisierende Parameter zu schaffen, um so deren interindividuelle Vergleichbarkeit zu ermöglichen. Hierzu werden in-vitro Messungen durchgeführt, welche geeignet sind das Verhalten der untersuchten Modelle unter unterschiedlichen Bedingungen und bei variierenden Defektgrößen zu charakterisieren.
The manufacturing of conventional electronics has become a highly complicated process, which requires intensive investment. In this context, printed electronics keeps attracting attention from both academia and industry. The primary reason is the simplification of the manufacturing process via additive printing technology such as ink-jet printing. Consequently, advantages are realized such as on-demand fabrication, minimal material waste and versatile choice of substrate materials. Central to the development of printed electronic circuits are printed transistors. Recently, metal oxide semiconductors such as indium oxide have become promising materials for the fabrication of printed transistors due to their high charge mobility. Furthermore, electrolyte-gating also provides benefits such as the low-voltage operation in sub-1 V regime due to the large gate capacitance provided by electrical double layers. This opens new possibilities to fabricate printed devices and circuits for niche applications.
To facilitate the design and fabrication of printed circuits, the development of compact models is necessary. However, most of the current works have focused on the study of the static behavior of transistors, while the in-depth understanding of other characteristics such as the dynamic or noise behavior is missing. To this end, the purpose of this work is the comprehensive study on capacitance and noise properties of inkjet-printed electrolyte-gated thin-film transistors (EGT) based on indium oxide semiconductors. Proper modeling approaches are also proposed to capture accurately the electrical behaviour, which can be further utilized to enable advanced analysis of digital, analog and mixed-signal circuits.
In this work, the capacitance of EGTs is characterized using voltage-dependent impedance spectroscopy. Intrinsic and extrinsic effects are carefully separated by using de-embedding test structures. Also, a dedicated equivalent circuit model is established to offer accurate simulations of the measured frequency response of the gate impedance. Based on that, it is revealed that top-gated EGTs have the potential to reach operation frequency in the kHz regime with proper optimizations of materials and printing process. Furthermore, a Meyer-like model is proposed to accurately capture the capacitance-voltage characteristics of the lumped terminal capacitance. Both parasitic and nonquasi-static effects are considered. This further enables the AC and transient analysis of complex circuits in circuit simulators.
Following, the study of noise properties in the field of printed electronics is conducted. Low-frequency noise of EGTs is characterized using a reliable experimental setup. By examining measured noise spectra of the drain current at various gate voltages, the number fluctuation with correlated mobility fluctuation has been determined as the primary noise mechanism. Based on that, normalized flat-band voltage noise can be determined as the key performance metrics, which is only 1.08 × 10−7 V^2 µm^2, significantly lower in comparison with other thin-film technologies, which are based on dielectric gating and semiconductors such as IZO and IGZO. A plausible reason could be the large gate capacitance offered by the electrical double layers. This renders EGT technology useful for low-noise and sensitive applications such as sensor periphery circuits.
Last but not least, various circuit designs based on EGT technology are proposed, including basic digital circuits such as inverters and ring oscillators. Their performance metrics such as the propagation delay and power consumption are extensively characterized. Also, the first design of a printed full-wave rectifier is presented by using diode-connected EGTs, which features near-zero threshold voltage. As a consequence, the presented rectifier can effectively process input voltage with a small amplitude of 100 mV and a cut-off frequency of 300 Hz, which is particularly attractive for the application domain of energy harvesting. Additionally, the previously established capacitance models are verified on those circuits, which provide a satisfactory agreement between the simulation and measurement data.
Im Jahre 2010 bot die Hochschule Offenburg ein Medizintechnikstudium mit dem Schwerpunkt ’Kardiologie, Elektrophysiologie und elektronische kardiologische Implantate’ als Bachelor- und später auch Masterstudiengang an. Ziel des auf diesen Schwerpunkt ausgelegten didaktischen Lehrkonzeptes ist die Vermittlung sofort anwendungsbereiten theoretischen Wissens und praktischen Könnens, welches die Absolventinnen und Absolventen in ihrer künftigen Berufsausübung in der Industrie oder als technische Partner der behandelnden Ärztinnen und Ärzte in hochspezialisierten klinischen Einrichtungen benötigen.
Aufgrund fehlender kommerzieller Angebote ist zur Umsetzung dieses Lehrkonzeptes die ingenieurtechnische Realisierung geeigneter Lehrmittel zwingend erforderlich. Dies betrifft die hard- und softwareseitige Erstellung visueller Demonstrationsmöglichkeiten für pathologische und implantatinduzierte Herzrhythmen, sowie die synthetische Bereitstellung originalgetreuer elektrokardiographischer Ableitsignale aus der klinischen Routine. Des Weiteren den Aufbau von in-vitro Trainingssystemen zu Therapien mit elektronischen kardiologischen Implantaten sowie zur Hochfrequenz-Katheterablation.
Insbesondere die Wahlfächer ’Programmierung von Herzschrittmachern’ und ‚Programmierung von Defibrillatoren’, deren Besuch den Teilnehmenden einen besonders raschen Berufseinstieg ermöglichen sollte, wurden in didaktischer Hinsicht in engem Bezug zum 4-Komponenten-Instruktionsdesign-Modell der Lehre gestaltet.
Durch den kontinuierlichen Einsatz der Instrumente der formativen Evaluation gelangen sowohl deutliche Verbesserungen am Gesamtkonzept der Lehrveranstaltungen als auch an den dort eingesetzten, selbst realisierten Lösungen des benannten speziellen Lehr- und Trainingsequipments.
Eine summative Evaluation des Lehrkonzeptes ist aufgrund seines Alleinstellungsmerkmals schwierig. Aus diesem Grund erschien die quantitative Prüfung des Einflusses eines Besuchs des praktisch orientierten Wahlfachs ’Programmierung von Herzschrittmachern’ auf die Note der kombinierten Abschlussklausur in den Fächern ’Elektrokardiographie’ und ’Elektrostimulation’ sinnvoll. In diese Evaluation eingeschlossen wurde eine Kohorte von 221 Studierenden, 76 Frauen und 145 Männer, von denen 93 am Wahlfach nicht teilnahmen und 128 die es besucht hatten.
Über 7 zusammengefasste Studienjahre zeigte sich, dass die praktische Ausbildung im Wahlfach ’Programmierung von Herzschrittmachern’ das Leistungsniveau der Studierenden der Medizintechnik in der kombinierten Abschlussprüfung ’Elektrokardiographie und Elektrostimulation’ deutlich beeinflusste.
Das im Rahmen dieser Arbeit mitgestaltete Lehrkonzept, die realisierten Lehrmaterialien und Lehrumgebungen wurden im Bachelor- und Masterstudiengang der Medizintechnik an der Hochschule Offenburg in den Praktika, Seminaren und Vorlesungen des Schwerpunktes ’Kardiologie, Elektrophysiologie und elektronische kardiologische Implantate’ vielfältig genutzt. Sie ermöglichten die Gestaltung interaktiver praktischer Weiterbildungsveranstaltungen für ärztliches und mittleres medizinisches Personal und für auf diesen Gebieten tätige medizintechnische Firmen.