Refine
Year of publication
Document Type
- Conference Proceeding (934)
- Article (reviewed) (559)
- Article (unreviewed) (124)
- Master's Thesis (66)
- Part of a Book (65)
- Contribution to a Periodical (58)
- Book (30)
- Bachelor Thesis (29)
- Patent (29)
- Letter to Editor (28)
Conference Type
- Konferenzartikel (734)
- Konferenz-Abstract (134)
- Sonstiges (34)
- Konferenz-Poster (22)
- Konferenzband (12)
Language
- English (1981) (remove)
Keywords
- RoboCup (32)
- Dünnschichtchromatographie (27)
- COVID-19 (23)
- Export (23)
- Machine Learning (19)
- Gamification (17)
- Kommunikation (15)
- Finite-Elemente-Methode (13)
- Government Measures (13)
- TRIZ (13)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (590)
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (501)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (373)
- Fakultät Wirtschaft (W) (281)
- INES - Institut für nachhaltige Energiesysteme (167)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (157)
- ivESK - Institut für verlässliche Embedded Systems und Kommunikationselektronik (146)
- Fakultät Medien (M) (ab 22.04.2021) (82)
- IMLA - Institute for Machine Learning and Analytics (72)
- ACI - Affective and Cognitive Institute (58)
Open Access
- Open Access (832)
- Closed Access (666)
- Closed (293)
- Bronze (137)
- Gold (75)
- Diamond (67)
- Hybrid (45)
- Grün (12)
The embedding of microwave devices is treated by applying the finite-difference method to three-dimensional shielded structures. A program package was developed to evaluate electromagnetic fields inside arbitrary transmission-line connecting structures and to compute the scattering matrix. The air bridge, the transition through a wall, and the bond wire are examined as interconnecting structures. Detailed results are given and discussed regarding the fundamental behavior of embedding.
Structures for interconnecting active microwave semiconductor-devices, e.g. FET's and MIC's, with the electrical surrounding or with each other have to be designed more and more carefully when increasing the desired upper frequency limit. Therefore, several connecting structures for device embedding have been examined. Mainly, their applicability for the frequency range from 10 GHz to 100 GHz was considered. Additionally, different equivalent circuits were developed to approximately describe their behaviour for CAD-applications.
It is demonstrated that microwave structures incorporating dielectric resonators (DR) are accurately characterised by means of a 3-dimensional finite-difference CAD package. All major assumptions made so far have been dropped, offering the possibility of a rigorous analysis of the embedding of dielectric resonators into microwave structures. In particular, a finite thickness for the microstrip conductor has been taken into account. The coupling of the DR to a microstrip placed in a metallic housing has been theoretically and experimentally investigated. Theoretical and experimental results are in good agreement and give new insight into DR coupling to microstrip circuits.
The advantages of the coupling-of-modes (COM) formalism and the transmission-matrix approach are combined to create exact and computationally efficient analysis and synthesis CAD tools for the design of SAW-resonator filters. The models for the filter components, especially gratings, interdigital transducers (IDTs). and multistrip couplers (MSCs), are based on the COM approach, which delivers closed-form expressions. In order to determine the relevant COM parameters, the integrated COM differential equations are compared with analytically derived expressions from the transmission-matrix approach. The most important second-order effects such as energy storage, propagation loss and mechanical and electrical loading are fully taken into account. As an example, the authors investigate a two-pole, acoustically coupled resonator filter at 914.5 MHz on AT quartz. Excellent agreement between theory and measurement is found.
The advantages of the coupled-mode (COM) formalism and the transmission-matrix approach are combined in order to create exact and computationally efficient analysis and synthesis tools for the design of coupled surface acoustic wave resonator filters. The models for the filter components, in particular gratings, interdigital transducers (IDTs) and multistrip couplers (MSCs), are based on the COM approach that delivers closed-form expressions. To determine the pertinent COM parameters, the COM differential equations are solved and the solution is compared with analytically derived expressions from the transmission-matrix approach and the Green's function method. The most important second-order effects, such as energy storage, propagation loss, and mechanical and electrical loading, are fully taken into account. As an example, a two-pole, acoustically coupled resonator filter at 914.5 MHz on AT quartz is investigated. Excellent agreement between theory and measurement is found.
An investigation is underway regarding the usefulness of altazimuth-mounting telescopes' incorporation of laser gyros for pointing and fiber gyros with extremely small random-walk coefficient for telescope inertial stabilization during tracking. A star tracker is expected to help stabilize long-term gyro bias. Gyro and telescope specifications have been derived by means of computer simulations and systems analyses.
A polarization mode dispersion measurement set-up based on a Mach-Zehnder Interferometer was realized. Measurements were carried out on short high-birefringent fibers and on long standard telecommunication single-mode fibers. In order to ensure high accurate results, special emphasis was placed on the evaluation of the interference pattern. The procedure will be described in detail and practical measurement results will be presented.
The prototype of an optical gyro encoder (OGE) has been successfully tested on the NTT telescope in September '93. The OGE consists of a ring laser gyro and a fiber optic gyro with their input axis parallel. The gyro outptu signals are compensated for earth rotation and misalignment and are subsequently integrated to get the angles. An adaptive digital control loop locks the fiber optic gyro to the laser gyro data. Thus the combined output has the precision of the laser gyro and the low noise of the fiber optic gyro. Specifically, the bias stability is better than 2 X 10-3 deg/h, the scale factor accuracy better than 1 ppm, the random walk coefficient better than 5 X 10-4 deg/(root)h and the resolution better than 3 X 10-4 arcsec. The OGE has been mounted in the altitude and in the azimuthy axis of the telescope. The data were compared with the telescope disk encoder data. The test data show that the pointing accuracy is about 1 arcsec and the tracking accuracy 0.1 arcsec over a time of 30 seconds. This accuracy is sufficient for the very large telescope, for instance.
This paper treats the Brillouin backscattering in a single mode optical fiber and its implications on the Brillouin Ring Laser Gyroscope (BRLG). The BRLG consists of a fiber ring cavity in which stimulated Brillouin scattering is induced and provides two resonant counterpropagating backscattered waves. If this cavity is rotating around its axis, the backscattered waves get different resonant frequencies because of the Sagnac effect. The frequency difference is proportional to the rotation rate (Omega) by inducing a frequency offset between the counterpropagating waves. Some reported Brillouin spectra exhibit several peaks, which means that one pump wave provides at least two backscattered waves with distinguishable frequencies. In order to understand this multi-backscattering and to take advantage of it for the BRLG, we present results of a simulation of the Brillouin backscattering in a single mode optical fiber.
Vortex breakdown phenomena in rotating fluids are investigated both theoretically and experimentally. The fluid is contained in a cone between two spherical surfaces. The primary swirling motion is induced ba the rotating lower boundary. The upper surface can be fixed with non-slip condition or can be a stress-free surface. Depending on these boundary conditions and on the Reynolds number, novel structures of recirculation zones are realized. The axisymmetric flow patterns are simulated numerically by a finite difference method. Experiments are done to visualize the topological structure of the flow pattern and to observe the existence ranges of the different recirculating flows. The comparison between theory and experiment shows good agreement with respect to the topological structure of the flow.
This paper treats the interaction between acoustic modes and light (Brillouin scattering) in a single mode optical fibre. Different observed spectra of the Brillouin backscattering in several fibres have been already reported. In order to have a clear idea of the process, we made a simulation to be able to `draw' the theoretical Brillouin spectrum of an optical fibre and to identify the origin of the observed backscattered lines.
First, the model and the computation method used in our simulation are described. Second, the experimentally observed spectra of two real fibres are compared with their computed spectra. Real spectra and simulated spectra are in good agreement.
Our work provides an interesting tool to investigate the changes in the Brillouin spectrum when the input parameters (characteristics of an optical fibre) vary. This should give useful indications to people working on systems which use Brillouin backscattering.
Formal verification (FV) is considered by many to be complicated and to require considerable mathematical knowledge for successful application. We have developed a methodology in which we have added formal verification to the verification process without requiring any knowledge of formal verification languages. We use only finite-state machine notation, which is familiar and intuitive to designers. Another problem associated with formal verification is state-space explosion. If that occurs, no result is returned; our method switches to random simulation after one hour without results, and no effort is lost. We have compared FV against random simulation with respect to development time, and our results indicate that FV is at least as fast as random simulation. FV is superior in terms of verification quality, however, because it is exhaustive.
The flow field-flow fractionation (FIFFF) technique is a promising method for separating and analysing particles and large size macromolecules from a few nanometers to approximately 50 μm. A new fractionation channel is described featuring well defined flow conditions even for low channel heights with convenient assembling and operations features. The application of the new flow field-flow fractionation channel is proved by the analysis of pigments and other small particles of technical interest in the submicrometer range. The experimental results including multimodal size distributions are presented and discussed.
An algorithm is presented that has successfully been utilized in practice for several years. It improves data analysis in chromatography. The program runs in an extremely reliable way and evaluates chromatographic raw data with an acceptable error. The algorithm requires a minimum of preliminaries and integrates even unsmoothed noisy data correctly.
We generalize the fluid flow problem of an oscillating flat plate (II. Stokes problem) in two directions. We discuss first the oscillating porous flat plate with superimposed blowing or suction. The second generalization is concerned with an increasing or decreasing velocity amplitude of the oscillating flat plate. Finally we show that a combination of both effects is possible as well.
Shapes and structures of vortex breakdown phenomena in rotating fluids are visualized. We investigate the flow in a cylindrical container and in a cone between two spherical surfaces. The primary swirling flow is induced by the rotating upper disk in the cylindrical case and by the lower boundary in the spherical case. The upper surface can be fixed with a no slip condition or can be a stress-free surface. Depending on these boundary conditions and on the Reynolds number novel structures of recirculation zones are realized. Experiments are done to visualize the topological structure of the flow and to determine their existence range as function of the geometry and rotation rate. A comparison between the experimental and theoretical approach shows a good agreement in respect to the topological structures of the flows.
Rotating flow systems are often used to study stability phenomena and structure developments. The closed spherical gap problem is generalized into an open flow system by superimposing a mass flux in meridional direction. The basic solutions at low Reynolds numbers are described by analytical methods. The nonlinear supercritical solutions are simulated numerically and realized in experiments. Novel steady and time-dependent modes of flows are obtained. The extensive results concern the stability behaviour, non-uniqueness of supercritical solutions, symmetry behaviour and transitions between steady and time-dependent solutions. The experimental investigations concern the visualization of the various instabilities and the quatitative description of the flow structures including the laminar-turbulent transition. A comparison between theoretical and experimental results shows good agreement within the limit of rotational symmetric solutions from the theory.
In this paper a high-performance thin-layer chromatography (HPTLC) scanner is presented in which a special fibre arrangement is used as HPTLC plate scanning interface. Measurements are taken with a set of 50 fibres at a distance of 400 to 500 μm above the HPTLC plate. Spatial resolutions on the HPTLC plate of better than 160 μm are possible. It takes less than 2 min to scan 450 spectra simultaneously in a range of 198 to 610 nm. The basic improvement of the item is the use of highly transparent glass fibres which provide excellent transmission at 200 nm and the use of a special fibre arrangement for plate illumination and detection.
A system for the on-line/in-line measurement of soot particle sizes and concentrations in the undiluted exhaust gas of diesel engines was developed and successfully tested. The unit uses the individual attenuations of three different laser wavelengths and is combined with an optical cell (white principle) with adjustable path lengths from 2.5 to 15 meters.
The title expresses goals the Kansas Geological Survey (KGS) has been working toward for some time. This report extends concepts and objectives developed while working on an earlier effort for effective interactive digital maps on the Internet. That work was reported to the 1998 DMT Workshop in Champaign, Illinois (Ross, 1998). The current project goes beyond previous efforts that focused on methods for serving the contents of a geographic information system (GIS); the points, lines, and polygons representing features of the digital geologic map and the data in the attribute tables of the GIS describing those features.
The importance of obtaining simultaneous particle size and concentration values has grown up with continuing discussion of the health effects, of internal combustion engine generated particulate emissions and in particular of Diesel soot emissions. In the present work an aerosol measurement system is described that delivers information about particle size and concentration directly from the undiluted exhaust gas.
Using three laser diodes of different wavelengths which form one parallel light beam, each spectral attenuation is analysed by a single detector and the particle diameter and concentration is evaluated by the use of the Mie theory and shown on-line at a frequency of 1 Hz. The system includes an optical long-path-cell (White principle) with an adjustable path length from 2.5 to 15 m, which allows the analysis within a broad concentration range.
On-line measurements of the particulate emissions in the hot, undiluted exhaust of Diesel engines are presented under stationary and transient engine’s load conditions. Mean particle diameters well below 100 nm are detected for modern Diesel engines. The measured particle concentration corresponds excellently with the traditional gravimetrical measurements of the diluted exhaust. Additionally, measurements of particle emissions (mostly condensed hydricarbons) from a two-stroke engine are presented and discussed.
A prototype multiwavelength sensor able to characterise soot emissions in Diesel exhaust in terms of size and concentration has been tested against other methods for diesel particle measurements like electrical mobility sizing (SMPS) and raw exhaust gravimetric sampling (RES). Measurements carried out with the prototype sensor were correlated with the SMPS by assuming spherical and/or fractal aggregate morphology of the particles. Correlation of RES gravimetric data against the sensor and the SMPS led to the calculation of the solid density for soot particles to be 2.3 gr/cm3.
HPTLC (High Performance Thin Layer Chromatography) is a well known and versatile separation method which shows many advantages when compared to other separation techniques. The method is fast and inexpensive and does not need time-consuming pretreatments. For visualisation of the sample distribution on a HPTLC-plate we developed a new and sturdy HPTLC-scanner. The scanner allows simultaneous registrations of spectra in a range from 198 nm to 612 nm with a spectral resolution of better than 0.8 nm. The on-plate spatial resolution is better than 160 μm. The measurement of 450 spectra in one separation track does not need more than two minutes. The new diode-array scanner offers a fast survey over a TLC-separation and makes various chemometric applications possible. For compound identification a cross-correlation function is described to compare UV sample spectra with appropriate library data. The cross-correlation function herein described can also be used for purity testing. Unresolved peaks can be virtually separated by use of a least squares fit algorithm. In summary, the diode arry system delivers much more information than the commonly used TLC-scanner.
High performance thin layer chromatography (HPTLC) is a frequently used separation technique which works well for quantification of caffeine and quinine in beverages. Competing separation techniques, e.g. high-performance liquid chromatography (HPLC) or gas chromatography (GC), are not suitable for sugar-containing samples, because these methods need special pretreatment by the analyst. In HPTLC, however, it is possible to separate ‘dirty’ samples without time-consuming pretreatment, because disposable HPTLC plates are used. A convenient method for quantification of caffeine and quinine in beverages, without sample pretreatment, is presented below. The basic theory of in-situ quantification in HPTLC by use of remitted light is introduced and discussed. Several linearization models are discussed.
A home-made diode-array scanner has been used for quantification; this, for the first time, enables simultaneous measurements at different wavelengths. The new scanner also enables fluorescence evaluation without further equipment. Simultaneous recording at different wavelengths improves the accuracy and reliability of HPTLC analysis. These aspects result in substantial improvement of in-situ quantitative densitometric analysis and enable quantification of compounds in beverages.
A new diode-array scanner in combination with a computer-controlled application system meets all the demands of modern HPTLC measurement. Automatic application, simultaneous measurements at different wavelengths, and different linearization models enable appropriate evaluation of all analytical questions. The theory of error propagation recommends quantification at reflectance values smaller than 0.8; this can be verified only by use of diode-array scanning. The same theory also recommends quantification by use of peak height data, because the theory predicts best precision only for peak height evaluation. Diode-array scanning with reflectance monitoring enables appropriate validation in TLC and HPTLC analysis. All these aspects result in substantial improvement of in-situ quantitative densitometric analysis, and simultaneous recording at different wavelengths opens the way for chemometric evaluation, e.g. peak purity monitoring, which improves the accuracy and reliability of HPTLC analysis.
A systematic toxicological analysis procedure using high-performance thin layer chromatography in combination with fibre optical scanning densitometry for identification of drugs in biological samples is presented. Two examples illustrate the practicability of the technique. First, the identification of a multiple intake of analgesics: codeine, propyphenazone, tramadol, flupirtine and lidocaine, and second, the detection of the sedative diphenhydramine. In both cases, authentic urine specimens were used. The identifications were carried out by an automatic measurement and computer-based comparison of in situ UV spectra with data from a compiled library of reference spectra using the cross-correlation function. The technique allowed a parallel recording of chromatograms and in situ UV spectra in the range of 197–612 nm. Unlike the conventional densitometry, a dependency of UV spectra by concentration of substance in a range of 250–1000 ng/spot was not observed.
The aim of this study was to develop a biomechanically validated finite element model to predict the biomechanical behaviour of the human lumbar spine in compression.
For validation of the finite element model, an in vitro study was performed: Twelve human lumbar cadaveric spinal segments (six segments L2/3 and six segments L4/5) were loaded in axial compression using 600 N in the intact state and following surgical treatment using two different internal stabilisation devices. Range of motion was measured and used to calculate stiffness.
A finite element model of a human spinal segment L3/4 was loaded with the same force in intact and surgically altered state, corresponding to the situation of biomechanical in vitro study.
The results of the cadaver biomechanical and finite element analysis were compared. As they were close together, the finite element model was used to predict: (1) load-sharing within human lumbar spine in compression, (2) load-sharing within osteoporotic human lumbar spine in compression and (3) the stabilising potential of the different spinal implants with respect to bone mineral density.
A finite element model as described here may be used to predict the biomechanical behaviour of the spine. Moreover, the influence of different spinal stabilisation systems may be predicted.
HPTLC (High Performance Thin Layer Chromatography) is a well known and versatile separation method which shows a lot of advantages and options in comparison to other separation techniques. The method is fast and inexpensive and does not need time-consuming pretreatments. Using fiber-optic elements for controlled light-guiding, the TLC-method was significantly improved: the new HPTLC-system is able to measure simultaneously at different wavelengths without destroying the plate surface or the analytes on the surface. For registration of the sample distribution on a HPTLC-plate we developed a new and sturdy diode-array HPTLC- scanner which allows registration of spectra on the TLC- plates in the range of 198 nm to 610 nm with a spectral resolution better than 1.2 nm. The spatial resolution on plate is better than 160 micrometers . In the spectral mode, the new HPTLC-scanner delivers much more information than the commonly used TLC-scanner. The measurement of 450 spectra of one separation track does not need more than three minutes. However, in the fixed wavelength mode the contour plot can be measured within 15 seconds. In this case, the signal will be summarized and averaged over a spectral range having FWHM from 10 nm to 25 nm depending on the substance under test. The new diode-array HPTLC-scanner makes various chemometric applications possible. The new method can be used easily in clinical diagnostic systems easily, e.g. for blood and uring investigations. In addition, new applications are possible. For example, the rich structured PAHs were studied. Although the separation is incomplete the 16 compounds can be quantified using suitable wavelengths.
The use of a TLC scanner can be regarded as a key step in high performance thin layer chromatography (HPTLC). Densitometric measurements transform the substance distribution on a TLC plate into digital computer data. Systems that allow quantitative measurements have been available for many years for either fluorescence or ultraviolet absorption measurements, while lately the reflection analysis mode for both types is the most common application. New scanning approaches are designed to aid the analyst who has common demands for TLC-densitometry without using special data, such as scanned images. Two examples that have been developed lately in the laboratories of the authors are described in this paper. These approaches were developed on the basis of current needs for analysts who employ TLC as a tool in research, as well as in routine analysis. One approach is aimed to support analysts in economically disadvantaged areas, where cost intensive apparatus is unsuitable but trace analysis by simple means is required. The other system, allows the spectral determination of chromatographic spots on TLC plates covering the ultraviolet and visible range, thus, revealing highly desired information for the analyst.
Time Resolved Measurements of Soot Concentrations and Mean Particle Sizes during EUDC and ECE Cycles
(2002)
The bandwidth behavior of graded-index multimode fibers (GI-MMFs) for different launching conditions is investigated to understand and characterize the effect of differential mode delay. In order to reduce the launch-power distribution the near field of a single-mode fiber is used to produce a controlled restricted launch. The baseband response is measured by observing the broadening of a narrow input pulse (time-domain measurement). The paper verifies the degradation in bandwidth due to profile distortion by scanning the spot of the single-mode fiber with a transversal offset from the center of the test sample. In addition, the impact of the launch-power distribution tuned by different spot-size diameters is demonstrated. Measurements were taken on ‘older’ 50-μm and 62.5-μm GI-MMFs as well as on laser-performance-optimized fibers more recently developed.
The central purpose of this paper is to present a novel framework supporting the specification, the implementation and retrieval of media streaming services. It provides an integrated service development environment comprising of a streaming service model, a service specification language and several implementation and retrieval tools. Our approach is based on a clear separation of a streaming service specification, and its implementation by a distributed application and can be used for different streaming paradigms, e.g. push and pull services.
A Simple and Reliable HPTLC Method for the Quantification of the Intense Sweetener Sucralose®
(2003)
This paper describes a simple and fast thin layer chromatography (TLC) method for the monitoring of the relatively new intense sweetener Sucralose® in various food matrices. The method requires little or no sample preparation to isolate or concentrate the analyte. The Sucralose® extract is separated on amino‐TLC‐plates, and the analyte is derivatized “reagent‐free” by heating the developed plate for 20 min at 190°C. Spots can be measured either in the absorption or fluorescence mode. The method allows the determination of Sucralose® at the levels of interest regarding foreseen European legislation (>50 mg/kg) with excellent repeatability (RSD = 3.4%) and recovery data (95%).
Fluorescence Enhancement of Pyrene Measured by Thin-Layer Chromatography with Diode-Array Detection
(2003)
In-situ densitometry for qualitative or quantitative purposes is a key step in thin-layer chromatography. It offers a simple way of quantifying by measuring the optical density of the separated spots directly on the plate. A new TLC scanner has been developed which is able to measure TLC plates or HPTLC plates, at different wavelengths simultaneously, without destroying the plate surface. The system enables absorbance and fluorescence measurements in one run. Fluorescence measurements are possible without filters or other adjustments.
The measurement of fluorescence from a TLC plate is a versatile means of making TLC analysis more sensitive. Fluorescence measurements with the new scanner are possible without filters or special lamps. Improvement of the signal-to-noise ratio is achieved by wavelength bundling. During plate scanning the scattered light and the fluorescence are both emitted from the surface of the TLC plate and this emitted light provides the desired spectral information from substances on the TLC plate. The measurement of fluorescence spectra and absorbance spectra directly from a TLC plate is based on differential measurement of light emerging from sample-free and sample-containing zones.
The literature recommends dipping TLC plates in viscous liquids to enhance fluorescence. Measurement of the fluorescence and absorbance spectra of pyrene spots reveals the mechanism of enhancement of plate dipping in viscous liquids—blocked contact of the fluorescent molecules with the stationary phase or other sample molecules is responsible for the enhanced fluorescence at lower concentrations.
In conclusion, dipping in TLC analysis is no miracle. It is based on similar mechanisms observable in liquids. The measured TLC spectra are also very similar to liquid spectra and this makes TLC spec-troscopy an important tool in separation analysis.
Details design tools and techniques for high performance ASIC-design. Shows the best practices for creating reusable designs in an SoC design methodology.
The free convection in a vertical gap is generalized to realize new analytical solutions of the Boussinesq-equations. The steady and time-dependent solutions for the temperature and velocity distribution are discussed in detail depending on the mass flux in vertical direction. The range of existence for flows with and without back flow is obtained. The transient behaviour of the solutions during the time-dependent development displays interesting physical behaviour.
The structure of the separation bubble that appears in the secondary meridional flow between two coaxially rotating spheres at low and finite Reynolds number (Re) is considered. The low Re analytical study was motivated by recognizing some errors in the analytical work on this problem by Arunachalam and Majhi (1987, Q. Jl Mech. Appl. Math., 40, 47) whilst the finite Re experimental study was motivated by the desire to observe the separation bubble in the laboratory. Though the finite Re experiments were performed in a confined apparatus, they exhibit the qualitative features of the low Re theoretical predictions for the axisymmetric separation bubble that encloses two toroidal vortices symmetrically disposed above and below the mid‐plane of sphere separation, but strong effects of confinement are apparent. The flows observed include (i) a wall‐attached bubble symmetric about the mid‐plane at low Re, (ii) symmetric free‐standing bubbles at moderate Re, and (iii) an asymmetric bubble with flow separating from one sphere and attaching to the support shaft between the spheres at sufficiently high Re.
Bluetooth personal area networks (PANs) share the 2.4 GHz ISM spectrum with the IEEE 802.11b wireless local area networks (WLANs). With the popularity of wireless devices, this ISM spectrum is becoming more and more crowded. As a result of this interference between WLANs and PANs, the performance of each network is decreased. Current research has not significantly covered the degrading impact of an 802.11b interferer on Bluetooth voice transmission. Within this project, simulations were carried out to precisely study the impact of an 802.11b interferer on the performance of Bluetooth voice transmission at different ratio levels of Bluetooth power to WLAN power at the receiver side. Furthermore, the impact of SNR on the Bluetooth voice performance and the benefit of using the SCORT packet type was analysed as well. Based on the results presented, network performance can be evaluated at the desired activity level.
The central purpose of this paper is to present a novel framework supporting the specification and the implementation of media streaming services using XML and Java Media Framework (JMF). It provides an integrated service development environment comprising of a streaming service model, a service specification language and several implementation and retrieval tools. Our approach is based on a clear separation of a streaming service specification, and its implementation by a distributed JMF application and can be used for different streaming paradigms, e.g. push and pull services.
The need of suitable system of records in gaining ground as companies seek to maximize performance by harnessing the knowledge of their businesses, is discussed. Focused systems of record deliver a clear and consistent view even as they address a range of functions. Enterprise resource planning (ERP), as the financial system of record, embodies that view of manufacturing, inventory management, accounting and order processing. Customer relationship management (CRM), as a system of record, taps not only into the marketing and sales and service, but also into product development.
A new formula is presented for transforming fluorescence measurements in accordance with Kubelka-Munk theory. The fluorescence signals, the absorption signals, and data from a selected reference are combined in one expression. Only diode-array techniques can measure all the required data simultaneously to linearize fluorescence data correctly. To prove the new theory HPTLC quantification of the analgesic flupirtine was performed over the mass range 300 to 5000 ng per spot. The fluorescence calibration curve was linear over the whole range. The transformation of fluorescence measurements into linear mass-dependent data extends the technique of in-situ fluorescence analysis to the high concentration range. It also extends Kubelka-Munk theory from absorption to fluorescence analysis. The results presented also emphasize the importance of Kubelka-Munk theory for in-situ measurements in scattering media, especially in planar chromatography.
In this paper, we propose a new streaming media service development environment comprising of a streaming media service model, a XML based service specification language and several implementation and configuration management tools. Our approach is based on a high level streaming service specification language, which allows specifying a service in terms of media objects, QoS, and distribution policies. Driven by such a streaming service specification and a streaming component library implemented with Java Media Framework, the required distributed application infrastructure is generated automatically by a service manager. To support flexible instantiation and termination of services as well as change management during runtime, e.g. migration or substitution of streaming components, we introduce instantiation and termination rules, and reconfiguration rules.
In contrast to their traditional, non-interactive counterparts, interactive dynamic visualisations allow users to adapt their form and content to their individual cognitive skills and needs. Provided that the interactive features allow for intuitive use without increasing cognitive load, interactive videos should therefore lead to more efficient forms of learning. This notion was tested in an experimental study, where participants learned to tie four nautical knots of different complexity by watching either non-interactive or interactive videos. The results show that in the interactive condition, participants used the interactive features like stopping, replaying, reversing or changing speed to adapt the pace of the video demonstration. This led to an uneven distribution of their attention and cognitive resources across the videos, which was more pronounced for the difficult knots. Consequently users of non-interactive video presentations, needed substantially more time than users of the interactive videos to acquire the necessary skills for tying the knots.