Refine
Year of publication
- 2010 (38) (remove)
Document Type
- Other (11)
- Conference Proceeding (10)
- Contribution to a Periodical (7)
- Article (reviewed) (5)
- Book (2)
- Article (unreviewed) (2)
- Part of a Book (1)
Conference Type
- Konferenzartikel (7)
- Konferenz-Abstract (3)
Keywords
- Brennstoffzelle (2)
- Deutschland (2)
- Elektrode (2)
- Glucose (2)
- Leichtbau (2)
- Radnabenmotor (2)
- Stadtfahrzeug (2)
- Diabetes mellitus (1)
- Elektromotor (1)
- Kosten (1)
Institute
Open Access
- Closed Access (38) (remove)
This paper gives an overview of the implementation of an Active Noise Control system on the TMS320C6713 Digital Signal Processor from Texas Instruments in the Digital Signal Processing Lab at Hochschule Offenburg, Germany. This system is implemented considering some non-ideal environmental conditions on a real system instead of being limited to computer simulations. Changes over time on the physical acoustical path as well as reverberation and variation on the power of the reference signal can strongly degrade the performance of the system or even lead to instability. In order to try to minimize these effects, the Active Noise Control system was designed to support a fast and easy implementation and evaluation of different algorithms on the DSP in real-time. In Section 1 a brief introduction about active noise control system is given and in section 2 the basic algorithm is described. In section 3 the implementation of the system is described and in section 4 some final considerations are given.
AG Köln "Kuh-Fotos"
(2010)
BGH "marions-kochbuch.de"
(2010)
BGH "Partnerprogramm"
(2010)
BGH "Schubladenverfügung"
(2010)
Cost effectiveness of preventive screening programmes for type 2 diabetes mellitus in Germany
(2010)
As in several other industrialized countries, Germany’s statutory health insurance (SHI) is facing rising healthcare costs as well as the challenges caused by a double-aging society. The early detection and prevention of chronic diseases is considered a possible way to reduce the impact of these developments. However, controversy surrounds the costs and effects in terms of medical and financial outcomes of such programmes.
The engineering company Evomotiv GmbH and the University of Applied Sciences Offenburg have developed a drive concept for light city scooters since 2008. The electrical drive train's goal is the series production of the highly-integrated, non-transmission and non-ferrous wheel-hub motor. The German Federal Ministry of Economy and Technology (BMWi) supports this project. The concept of this wheel-hub motor was awarded with the Bosch-Innovation prize in 2006. In 2011 Evomotiv will test the first prototypes with its cooperation partners on the track.
Das Ingenieurbüro Evomotiv GmbH und die University of Applied Sciences Offenburg entwickeln seit Ende 2008 ein Antriebskonzept für leichte Stadtfahrzeuge. Ziel des Elektroantriebs ist die Serientauglichkeit der hochintegrierten, getriebelosen und eisenfreien Radnabenmotoren. Das Bundesministerium für Wirtschaft und Technologie (BMWi) unterstützt das Projekt. Das Konzept des Radnabenmotors erhielt 2006 den Bosch—Innovationspreis und gewann 2008 den Shell-Eco-Marathon. Im Jahr 2011 wird Evomotiv mit seinen Partnern erste Prototypen auf der Straße testen.
EuGH "Bananabay"
(2010)
EuGH "Millionen-Chance"
(2010)
EuGH "sunrise period"
(2010)
AV delay (AVD) optimization can improve hemodynamics and avoid nonresponding to cardiac resynchronization therapy (CRT). AVD can be approximated by the sum of the individual implant-related interatrial conduction interval and a mean electromechanical interval of about 50ms. We searched for methods to facilitate automatic, implant-based AV delay optimization. In 25 patients (19m, 6f, age: 65±8yrs.) with Medtronic Insync III Marquis CRT-D series systems and left ventricular electrode at lateral or posterolateral wall, we determined interatrial conduction intervals by telemetric left ventricular tip versus superior vena cava coil electrogram (LVCE). Compared with esophageal measurements, the duration of optimal AV delay by LVCE showed good correlation (k=0.98, p=0.01) with a difference of 1.5±4.9ms, only. Therefore, LVCE is feasible to determine interatrial conduction intervals in order to automate AV delay optimization in CRT-D pacing promising increased accuracy compared to other algorithms.
LG Mannheim "Abofallen"
(2010)
Längst kein Auslaufmodell
(2010)
In dem Aufsatz geht es um Arbeitszeugnisse. Im Titelthema der Ausgabe 06/2010 hat sich die Personalwirtschaft kritisch mit der Rechtslage und der Praxis rund um die Ausstellung von Arbeitszeugnissen auseinander gesetzt. „Das Papier nicht wert“ war damals die provokante Überschrift. Ein zu hartes Urteil, wie der Autor von der Hochschule Offenburg findet.
In their famous work on prospect theory Kahneman and Tversky have presented a couple of examples where human decision making deviates from rational decision making as defined by decision theory. This paper describes the use of extended behavior networks to model human decision making in the sense of prospect theory. We show that the experimental findings of non-rational decision making described by Kahneman and Tversky can be reproduced using a slight variation of extended behavior networks.
OLG Hamm "Abmahnfalle WAP"
(2010)
Phishing im Emissionshandel
(2010)
AV delay (AVD) optimization is mandatory in cardiac resynchronization (CRT) for heart failure. Several time consuming methods exist. We initialized development of left-atrial electrogram (LAE) feature for Biotronik ICS3000 programmer. It can be utilized to approximate optimal AV delay in CRT patients with pacing systems irrespective of make and model. Using this feature, we studied the share of interatrial conduction intervals (IACT) on individual echo AVD in 45 CRT patients (34m, 11f, mean age 69±6yrs.). The percentage of IACT on optimal echo AVD resulted in44.5±22.1% for VDD and 70.7±10.9% for DDD operation. In all patients, optimal echo AVDs exceeded the individual IACT by a duration of 52.5±33.3ms (p<0.001), at mean. Therefore, if AV delay optimization is not possible or not practicable in CRT patients, AVD should be approximated by individually measuring IACT and adding about 50ms.
We present a novel fabrication route yielding Raney-platinum film electrodes intended as glucose oxidation anodes for potentially implantable fuel cells. Fabrication roots on thermal alloying of an extractable metal with bulk platinum at 200 °C for 48 h. In contrast to earlier works using carcinogenic nickel, we employ zinc as potentially biocompatible alloying partner. Microstructure analysis indicates that after removal of extractable zinc the porous Raney-platinum film (roughness factor ∼2700) consists predominantly of the Pt3Zn phase. Release of zinc during electrode operation can be expected to have no significant effect on physiological normal levels in blood and serum, which promises good biocompatibility. In contrast to previous anodes based on hydrogel-bound catalyst particles the novel anodes exhibit excellent resistance against hydrolytic and oxidative attack. Furthermore, they exhibit significantly lower polarization with up to approximately 100 mV more negative electrode potentials in the current density range relevant for fuel cell operation. The anodes’ amenability to surface modification with protective polymers is demonstrated by the exemplary application of an approximately 300 nm thin Nafion coating. This had only a marginal effect on the anode long-term stability and amino acid tolerance. While in physiological glucose solution after approximately 100 h of operation gradually increasing performance degradation occurs, rapid electrode polarization within 24 h is observed in artificial tissue fluid. Optimization approaches may include catalyst enhancement by adatom surface modification and the application of specifically designed protective polymers with controlled charge and mesh size.
We report the fabrication and characterization of glucose-tolerant Raney-platinum cathodes for oxygen reduction in potentially implantable glucose fuel. Fabricated by extraction of aluminum from 1 μm thin platinum–aluminum bi-layers annealed at 300 °C, the novel cathodes show excellent resistance against hydrolytic and oxidative attack. This renders them superior over previous cathodes fabricated from hydrogel-bound catalyst particles. Annealing times of 60, 120, and 240 min result in approximately 400–550 nm thin porous films (roughness factors ∼100–150), which contain platinum and aluminum in a ratio of ∼9:1. Aluminum release during electrode operation can be expected to have no significant effect on physiological normal levels, which promises good biocompatibility. Annealing time has a distinct influence on the density of trenches formed in the cathode. Higher trench densities lead to lower electrode potentials in the presence of glucose. This suggests that glucose sensitivity is governed by mixed potential formation resulting from oxygen depletion within the trenches. During performance characterization the diffusion resistance to be expected from tissue capsule formation upon electrode implantation was taken into account by placing a membrane in front of the cathode. Despite the resulting limited oxygen supply, cathodes prepared by annealing for 60 min show more positive electrode potentials than previous cathodes fabricated from hydrogel-bound activated carbon. Compared to operation in phosphate buffered saline containing 3.0 mM glucose, a potential loss of approximately 120 mV occurs in artificial tissue fluid. This can be reduced to approximately 90 mV with a protective Nafion layer that is easily electro-coated onto the Raney-platinum film.
Using guideline parameters for indication of cardiac resynchronization therapy (CRT), only about two thirds of the patients improve clinically. Unfortunately both, surface ECG and echo are uncertain to predict CRT response. To better characterize cardiac desynchronization in heart failure, interventricular (IVCD) and intra-leftventricular conduction delays (ILVCD) were measured by esophageal left ventricular electrogram (LVE). Recordings in 43 CRT patients (34m, 9f, age: 64.7 ± 9.5yrs) evidenced only weak correlation between IVCD and QRS of 0.53 and between ILVCD and QRS of 0.33. This demonstrated that QRS duration is not a reliable indicator of desynchronization. Therefore, the study resulted into development of LVE feature for a programmer with implant support device. It can be used interoperatively to guide the left ventricular electrode location in order to increase responder rate in CRT.