Refine
Year of publication
Document Type
- Conference Proceeding (43)
- Article (reviewed) (13)
- Contribution to a Periodical (8)
- Patent (6)
Conference Type
- Konferenz-Abstract (34)
- Konferenzartikel (6)
- Konferenz-Poster (3)
Is part of the Bibliography
- yes (70)
Keywords
- Herzrhythmusmodell (6)
- CRT (5)
- CST (5)
- HF-Ablation (5)
- Herzkrankheit (5)
- Synchronisierung (4)
- heart rhythm model (4)
- Herzschrittmacher (3)
- Kardiale Resynchronisationstherapie (3)
- Vorhofflimmern (3)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (46)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (22)
- POIM - Peter Osypka Institute of Medical Engineering (11)
- CRT - Campus Research & Transfer (2)
- Zentrale Einrichtungen (2)
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (1)
Open Access
- Open Access (70) (remove)
In cardiac resynchronization therapy (CRT) for heart failure, individualization of the AV delay is essential to improve hemodynamics and to minimize non-responder rate. In patients in sinus rhythm having additional disposition to bradycardia, optimization is necessary for both situations, atrial sensing and pacing. Therefore, echo-optimization is the goldstandard but time consuming. Unfortunately, it depends on the particular CRT systems parameter set if the resulting individually optimal AV delays can be programmed or not. Some CRT systems provide a set of AV delays for DDD operation combined with a set of the pace-sense-compensation to optimize the AV delay in DDD and VDD operation. The pace-sense-compensation (PSC) can be defined by the difference of implant-related interatrial conduction intervals in DDD and VDD operation measured in the esophageal left atrial electrogram. In a cohort of 96 CRT patients we found mean PSC of 59-35ms ranging between 0-143ms. As a consequence, allowing 10ms tolerance, AVD optimization is completely impossible in one of the two modes, VDD or DDD operation, in 34 (35%) or 5 (5%) patients with implants restricting the PSC range to 60ms or 100ms, respectively. Thus, we propose companies to provide CRT systems with programmable pace-sense- compensation between 0ms and 150ms.
Die vorliegende Erfindung betrifft Vorrichtungen zum Überwachen und Optimieren einer zeitlichen Triggerstabilität einer extrakorporalen Kreislaufunterstützung sowie Steuer- und Regeleinheiten zur extrakorporalen Kreislaufunterstützung, umfassend eine solche Vorrichtung und entsprechende Verfahren. Entsprechend wird eine Vorrichtung (10) zum Überwachen einer zeitlichen Triggerstabilität einer extrakorporalen Kreislaufunterstützung vorgeschlagen, welche dazu eingerichtet ist, einen ersten Datensatz (14) einer Messung eines EKG-Signals eines unterstützten Patienten über einen vorgegebenen Zeitraum zu empfangen. Die Vorrichtung (10) umfasst eine Auswerteeinheit (16), welche dazu eingerichtet ist, mehrere R-Trigger (26) aus dem ersten Datensatz (14) zu bestimmen oder zu identifizieren, wobei die Auswerteeinheit (16) weiterhin dazu eingerichtet ist, einen zweiten Datensatz (20) mit ausgewerteten EKG-Signalen und mehreren R-Triggern (28) zu empfangen oder bereitzustellen und den zweiten Datensatz (20) selektiv auf dem ersten Datensatz (14) abzubilden. Die Vorrichtung ist weiterhin dazu eingerichtet, ein Signal (22) auszugeben, welches kennzeichnend für einen zeitlichen Abstand sukzessiver R-Trigger (26) aus dem ersten Datensatz (14) und darauf abgebildeten sukzessiven R-Trigger (28) aus dem zweiten Datensatz (20) ist.
Vergleich der hämodynamischen Reaktion auf VV-Delay Änderungen bei Sinusrhythmus und Vorhofflimmern
(2010)
Das Ausmaß der elektrischen ventrikulären Desynchronisation bei reduzierter linksventrikulärer Funktion ist von Bedeutung für den Erfolg der Resynchronisationstherapie der Herzinsuffizienz mit biventrikulärer Stimulation. Das Ziel der Untersuchung besteht in der nichtinvasiven Messung der elektrischen inter-ventrikulären Desynchronisation mit und ohne ischämische Herzerkrankung bei kardialen Resynchronisationstherapie Respondern. Bei Patienten mit 25,3 ± 7,3 % reduzierter linksventrikulärer Ejektionsfraktion und 166,9 ± 38,5 ms QRS-Dauer wurde das transösophageale linksventrikuläre EKG abgeleitet. Die QRS-Dauer korrelierte mit dem interventrikulären und links-ventrikulären Delay bei Resynchronisationstherapie Respondern mit nicht-ischämischer Herzerkrankung.
Cardiac resynchronization therapy is an established therapy for heart failure patients with sinus rhythm, reduced left ventricular ejection fraction and prolongation of QRS duration. The aim of the study was to evaluate ventricular desynchronization with electrical interventricular delay (IVD) to left ventricular delay (LVD) ratio in atrial fibrillation heart failure patients. IVD and LVD were measured by transesophageal posterior left ventricular ECG recording. In atrial fibrillation heart failure patients with prolonged QRS duration, the mean IVD-to-LVD-ratio was 0.84 +/- 0.42 with a range from 0.17 to 2.2 IVD-to-LVD-ratio. IVD-to-LVD-ratio correlated with QRS duration. IVD-to-LVD-ratio may be a useful parameter to evaluate electrical ventricular desynchronization in atrial fibrillation heart failure patients.
Transösophageales interventrikuläres Delay bei Vorhofflimmern und kardialer Resynchronisation
(2013)
Die transösophageale linksventrikuläre Elektrokardiographie ermöglicht die Evaluierung der elektrischen ventrikulären Desynchronisation im Rahmen der kardialen Resynchronisationstherapie der Herzinsuffizienz. Das Ziel der Untersuchung besteht in der präoperativen Abschätzung des transösophagealen interventrikulären Delays bei Vorhofflimmern und kardialer Resynchronisationstherapie. Bei Patienten mit Vorhofflimmern, Herzinsuffizienz New York Heart Association Klasse 3,0 ± 0,2 und QRS-Dauer 159,6 ± 23,9 ms wurde das fokusierte transösophageale linksventrikuläre EKG abgeleitet. Die kardiale Resynchronisationstherapie Responder QRS-Dauer korrelierte mit dem transösophagealen interventrikulären Delay bei Vorhofflimmern.
Transthoracic impedance cardiography (ICG) is a non-invasive method for determination of hemodynamic parameters. The basic principle of transthoracic ICG is the measurement of electrical conductivity of the thorax over the time. The aim of the study was the analysis of hemodynamic parameters from healthy individuals and the evaluation of various hemodynamic monitoring devices. Fourteen men (mean age 25 ± 4.59 years) and twelve women (mean age 24 ± 3.5 years) were measured during the cardiovascular engineering laboratory at Offenburg University of Applied Sciences, Offenburg, Germany. The ICG recordings were measured with the devices CardioScreen 1000, CardioScreen 2000 and TensoScreen with the corresponding Software Cardiovascular Lab 2.5 (Medis Medizinische Messtechnik GmbH, Illmenau, Germany). In order to create identical frame conditions, all measurements were recorded in the same position and for the same duration. Various positions were simulated from horizontal lying position to vertical standing position. Altogether, more than 30 hemodynamic parameters were measured.
Die vorliegende Erfindung betrifft Steuer- und Regeleinheiten für eine extrakorporale Kreislaufunterstützung sowie Systeme, umfassend eine solche Steuer- und Regeleinheit und entsprechende Verfahren. Entsprechend wird eine Steuer- und Regeleinheit Steuer- und Regeleinheit (10) für eine extrakorporale Kreislaufunterstützung vorgeschlagen, welche dazu eingerichtet ist eine Messung eines EKG-Signals (12) eines unterstützten Patienten über einen vorgegebenen Zeitraum zu empfangen, wobei das EKG-Signal (12) für jeden Zeitpunkt innerhalb eines Herzzyklus mehrere Datenpunkte umfasst. Die Steuer- und Regeleinheit (10) umfasst eine Auswerteeinheit (100), welche dazu eingerichtet ist, die Datenpunkte für mindestens einen Zeitpunkt räumlich und/oder zeitlich auszuwerten und aus den ausgewerteten Datenpunkten mindestens eine Amplitudenänderung (14) innerhalb des Herzzyklus zu bestimmen. Die Steuer- und Regeleinheit (10) ist weiterhin dazu eingerichtet, ein Steuer- und/oder Regelsignal (16) für die extrakorporale Kreislaufunterstützung an einem vorgegebenen Zeitpunkt nach der mindestens einen Amplitudenänderung (14) auszugeben.
Die vorliegende Erfindung betrifft Steuer- und Regeleinheiten für eine extrakorporale Kreislaufunterstützung sowie Systeme, umfassend eine solche Steuer- und Regeleinheit und entsprechende Verfahren. Entsprechend wird eine Steuer- und Regeleinheit (10) für eine extrakorporale Kreislaufunterstützung vorgeschlagen, welche dazu eingerichtet ist eine Messung eines EKG-Signals (12) eines unterstützten Patienten über einen vorgegebenen Zeitraum zu empfangen und für die extrakorporale Kreislaufunterstützung bereitzustellen, wobei das EKG-Signal (12) für jeden Zeitpunkt innerhalb eines Herzzyklus eine Signalhöhe aus mindestens einer EKG-Ableitung (14A, 14B) umfasst. Die Steuer- und Regeleinheit (10) umfasst eine Auswerteeinheit (16), welche dazu eingerichtet ist, eine Signaldifferenz (18) einer Signalhöhe eines aktuellen Zeitpunkts (12A) und einer Signalhöhe des vorhergehenden Zeitpunkts (12B) zu bestimmen und die Signaldifferenz (18) mit einem vorgegebenen Schwellenwert (20) zu vergleichen. Die Steuer- und Regeleinheit (10) ist weiterhin dazu eingerichtet, das EKG-Signal (22) beim Überschreiten des Schwellenwerts (20) für den aktuellen Zeitpunkt und eine vorgegebene Anzahl von nachfolgenden Zeitpunkten (28) mit einer vorgegebenen Signalhöhe (30) bereitzustellen.
Spectral analysis of signal averaging electrocardiography in atrial and ventricular tachyarrhythmias
(2017)
Background: Targeting complex fractionated atrial electrograms detected by automated algorithms during ablation of persistent atrial fibrillation has produced conflicting outcomes in previous electrophysiological studies. The aim of the investigation was to evaluate atrial and ventricular high frequency fractionated electrical signals with signal averaging technique.
Methods: Signal averaging electrocardiography (ECG) allows high resolution ECG technique to eliminate interference noise signals in the recorded ECG. The algorithm uses automatic ECG trigger function for signal averaged transthoracic, transesophageal and intracardiac ECG signals with novel LabVIEW software (National Instruments, Austin, Texas, USA). For spectral analysis we used fast fourier transformation in combination with spectro-temporal mapping and wavelet transformation for evaluation of detailed information about the frequency and intensity of high frequency atrial and ventricular signals.
Results: Spectral-temporal mapping and wavelet transformation of the signal averaged ECG allowed the evaluation of high frequency fractionated atrial signals in patients with atrial fibrillation and high frequency ventricular signals in patients with ventricular tachycardia. The analysis in the time domain evaluated fractionated atrial signals at the end of the signal averaged P-wave and fractionated ventricular signals at the end of the QRS complex. The analysis in the frequency domain evaluated high frequency fractionated atrial signals during the P-wave and high frequency fractionated ventricular signals during QRS complex. The combination of analysis in the time and frequency domain allowed the evaluation of fractionated signals during atrial and ventricular conduction.
Conclusions: Spectral analysis of signal averaging electrocardiography with novel LabVIEW software can utilized to evaluate atrial and ventricular conduction delays in patients with atrial fibrillation and ventricular tachycardia. Complex fractionated atrial electrograms may be useful parameters to evaluate electrical cardiac arrhythmogenic signals in atrial fibrillation ablation.