Refine
Year of publication
- 2018 (32) (remove)
Document Type
- Conference Proceeding (32) (remove)
Conference Type
- Konferenzartikel (24)
- Konferenz-Abstract (5)
- Sonstiges (3)
Language
- English (32) (remove)
Is part of the Bibliography
- yes (32)
Keywords
- RoboCup (3)
- 5G mobile communication (2)
- Access protocols (2)
- Decoding (2)
- Multiuser detection (2)
- Payloads (2)
- Physical layer (2)
- access protocols (2)
- decoding (2)
- network coding (2)
- Atrial fibrillation (1)
- Atrioventricular delay (1)
- Biventricular pacing (1)
- Cardiac resynchronization therapy (1)
- Fractionated atrial signals (1)
- Fractionated ventricular signals (1)
- Left atrial ECG (1)
- Left atrial delay (1)
- Left cardiac ECG (1)
- MEMS (1)
- Signal averaging ECG (1)
- Spectral-temporal mapping (1)
- Transesophageal electrocardiography (1)
- Ventricular tachycardia (1)
- accelerometer (1)
- cluster (1)
- gyroscope (1)
- inertial measurement unit (1)
- machine learning (1)
- temperature dependency (1)
Institute
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (32) (remove)
Open Access
- Closed Access (20)
- Open Access (11)
- Bronze (3)
- Closed (1)
In this paper, we present a frame synchronization method which consists of the non-orthogonal superposition of a synchronization sequence and the data. We derive the optimum detection criterion and compare it to the classical sequential concatenation of synchronization and data sequences. Computer simulations confirm the benefits of the non-orthogonal allocation for the case of short frames, which makes this technique particularly suited for the increasingly important regime of low latency and ultra- reliable communication.
This paper deals with the detection and segmentation of clouds on high-dynamic-range (HDR) images of the sky as well as the calculation of the position of the sun at any time of the year. In order to predict the movement of clouds and the radiation of the sun for a short period of time, the clouds thickness and position have to be known as precisely as possible. Consequently, the segmentation algorithm has to provide satisfactory results regardless of different weather, illumination and climatic conditions. The principle of the segmentation is based on the classification of each pixel as a cloud or as a sky. This classification is usually based on threshold methods, since these are relatively fast to implement and show a low computational burden. In order to predict if and when the sun will be covered by clouds, the position of the sun on the images has to be determined. For this purpose, the zenith and azimuth angles of the sun are determined and converted into XY coordinates.
Solar irradiance prediction is vital for the power management and the cost reduction when integrating solar energy. The study is towards a ground image based solar irradiance prediction which is highly dependent on the cloud coverage. The sky images are collected by using ground based sky imager (fisheye lens). In this work, different algorithms for cloud detection being a preparation step for their segmentation are compared.
The fisheye camera has been widely studied in the field of ground based sky imagery and robot vision since it can capture a wide view of the scene at one time. However, serious image distortion is a major drawback hindering its wider use. To remedy this, this paperproposes a lens calibration and distortion correction method for detecting clouds and forecasting solar radiation. Finally, the radial distortion of the fisheye image can be corrected by incorporating the estimated calibration parameters. Experimental results validate the effectiveness of the proposed method.
Cardiac resynchronization therapy (CRT) with hemodynamic optimized biventricular pacing is an established therapy for heart failure patients with sinus rhythm, reduced left ventricular ejection fraction and wide QRS complex. The aim of the study was to evaluate electrical right and left cardiac atrioventricular delay and left atrial delay in CRT responder and non-responder with sinus rhythm.
Methods: Heart failure patients with New York Heart Association class 3.0 ± 0.3, sinus rhythm and 27.7 ± 6.1% left ventricular ejection fraction were measured by surface ECG and transesophageal bipolar left atrial and left ventricular ECG before implantation of CRT devices. Electrical right cardiac atrioventricular delay was measured between onset of P wave and onset of QRS complex in the surface ECG, left cardiac atrioventricular delay between onset of left atrial signal and onset of left ventricular signal in the transesophageal ECG and left atrial delay between onset and offset of left atrial signal in the transesophageal ECG.
Results: Electrical atrioventricular and left atrial delay were 196.9 ± 38.7 ms right and 194.5 ± 44.9 ms left cardiac atrioventricular delay, and 47.7 ± 13.9 ms left atrial delay. There were positive correlation between right and left cardiac atrioventricular delay (r = 0.803 P < 0.001) and negative correlation between left atrial delay and left ventricular ejection fraction (r = −0.694 P = 0.026) with 67% CRT responder.
Conclusions: Transesophageal electrical left cardiac atrioventricular delay and left atrial delay may be useful preoperative atrial desynchronization parameters to improve CRT optimization.