Refine
Year of publication
Document Type
- Article (reviewed) (73)
- Conference Proceeding (45)
- Article (unreviewed) (20)
- Report (15)
- Part of a Book (11)
- Book (6)
- Patent (4)
- Doctoral Thesis (3)
- Contribution to a Periodical (1)
Conference Type
- Konferenzartikel (34)
- Konferenz-Abstract (10)
- Konferenz-Poster (1)
Has Fulltext
- no (178) (remove)
Is part of the Bibliography
- yes (178)
Keywords
- Lithiumbatterie (10)
- Energieversorgung (9)
- Haustechnik (9)
- Brennstoffzelle (6)
- Wärmepumpe (6)
- Batterie (5)
- Bauteil (4)
- Elektrochemie (4)
- Energietechnik (4)
- Fotovoltaik (4)
Institute
- INES - Institut für nachhaltige Energiesysteme (178) (remove)
Open Access
- Closed Access (63)
- Open Access (52)
- Closed (21)
- Bronze (10)
- Diamond (4)
- Gold (2)
- Grün (1)
With the increasing share of renewable energies and the nuclear phase-out, the energy transition is accelerating. From the perspective of building technology, there is great potential to support this transition given its large share in total energy consumption and the increasing number of flexible and controllable components and storages. However, a question often asked at the plant level is: "How do we use this flexibility to support the regional grid?". In this work, a grid-supportive controller of a real-world building energy plant was developed using mathematical optimisation methods and its technical feasibility was demonstrated. The results could convince actors from the energy industry and academia about the practicality of these methods and offer tools for their implementation.
Given the looming threats of climate change and the rapid worldwide urbanization, it is a necessity to prioritize the transition towards a carbon-free built environment. This research study provides a holistic digital methodology for parametric design of urban residential buildings with regard to the Mediterranean semi-arid climate zone of Morocco in the early design phase. The morphological parameters of the urban residential buildings, namely the buildings’ typology, the distance between buildings, the urban grid’s orientation, and the window-towall ratio, are evaluated in order to identify the key combinations of passive and active solar design strategies that determine the high energy performing configurations, based on the introduced Energy Performance Index (EPI), which is the ratio between solar BIPV production to maximum available installed BIPV capacity and the normalized thermal energy needs. Through an automated processing of 2187 iterations via Grasshopper, we simulate daylight autonomy, indoor thermal comfort and solar rooftop photovoltaic and building integrated photovoltaic (BIPV) energy potential. Then, we analyze the conflicting objectives of energy efficiency measures, active solar design strategies, and indoor visual comfort in the decision-making process that supports our goal of getting closer to net zero urban residential buildings. The digital workflow showed interesting trends in reaching a balanced equilibrium between performance metrics influenced by the contrasting impact of solar exposure on indoor daylight autonomy and thermal energy demand. Furthermore, the study’s findings indicate that it is possible to achieve an annual load match exceeding 66,56 % while simultaneously ensuring an acceptable visual indoor comfort (sDA higher than 0.4). The findings also highlight the important role of the BIPV system in shifting towards the net zero energy goal, by contributing up to 30 % of the overall solar energy output and covering up to 20 % of the yearly self-consumption. Moreover, the energy balance evaluation on an hourly basis indicates that BIPV system notably enhances the daily load cover factor by up to 5.5 %, particularly in the case of slab SN typology, throughout the different seasons. Graphical representations of the yearly, monthly and hourly load matches and the hourly energy balance of the best performing configurations provide a thorough understanding of the potential evolution of the urban energy system over time as a result of the gradual integration of active solar electricity production.
This paper presents the use of model predictive control (MPC) based approach for peak shaving application of a battery in a Photovoltaic (PV) battery system connected to a rural low voltage gird. The goals of the MPC are to shave the peaks in the PV feed-in and the grid power consumption and at the same time maximize the use of the battery. The benefit to the prosumer is from the maximum use of the self-produced electricity. The benefit to the grid is from the reduced peaks in the PV feed-in and the grid power consumption. This would allow an increase in the PV hosting and the load hosting capacity of the grid.
The paper presents the mathematical formulation of the optimal control problem
along with the cost benefit analysis. The MPC implementation scheme in the
laboratory and experiment results have also been presented. The results show
that the MPC is able to track the deviation in the weather forecast and operate
the battery by solving the optimal control problem to handle this deviation.
The durability of polymer electrolyte membrane fuel cells (PEMFC) is governed by a nonlinear coupling between system demand, component behavior, and physicochemical degradation mechanisms, occurring on timescales from the sub-second to the thousand-hour. We present a simulation methodology for assessing performance and durability of a PEMFC under automotive driving cycles. The simulation framework consists of (a) a fuel cell car model converting velocity to cell power demand, (b) a 2D multiphysics cell model, (c) a flexible degradation library template that can accommodate physically-based component-wise degradation mechanisms, and (d) a time-upscaling methodology for extrapolating degradation during a representative load cycle to multiple cycles. The computational framework describes three different time scales, (1) sub-second timescale of electrochemistry, (2) minute-timescale of driving cycles, and (3) thousand-hour-timescale of cell ageing. We demonstrate an exemplary PEMFC durability analysis due to membrane degradation under a highly transient loading of the New European Driving Cycle (NEDC).
The DMFC is a promising option for backup power systems and for the power supply of portable devices. However, from the modeling point of view liquid-feed DMFC are challenging systems due to the complex electrochemistry, the inherent two-phase transport and the effect of methanol crossover. In this paper we present a physical 1D cell model to describe the relevant processes for DMFC performance ranging from electrochemistry on the surface of the catalyst up to transport on the cell level. A two-phase flow model is implemented describing the transport in gas diffusion layer and catalyst layer at the anode side. Electrochemistry is described by elementary steps for the reactions occurring at anode and cathode, including adsorbed intermediate species on the platinum and ruthenium surfaces. Furthermore, a detailed membrane model including methanol crossover is employed. The model is validated using polarization curves, methanol crossover measurements and impedance spectra. It permits to analyze both steady-state and transient behavior with a high level of predictive capabilities. Steady-state simulations are used to investigate the open circuit voltage as well as the overpotentials of anode, cathode and electrolyte. Finally, the transient behavior after current interruption is studied in detail.
In dieser Arbeit werden die außentemperaturgeführte Vorlauftemperaturregelung (Standard-TABS-Strategie), ein Verfahren das auf einer multiplen linearen Regression basiert (AMLR-Strategie) und ein Verfahren, das unter dem Obergriff der modellprädiktiven Regelung (MPC-Strategie) zusammengefasst werden kann, untersucht. Anhand der Simulationsergebnisse und des Integrationsaufwandes in die Gebäudeautomation des Seminargebäudes wurde eine Fokussierung auf die AMLR-Strategie vorgenommen.
There is a growing trend for the use of thermo-active building systems (TABS) for the heating and cooling of buildings, because these systems are known to be very economical and efficient. However, their control is complicated due to the large thermal inertia, and their parameterization is time-consuming. With conventional TABS-control strategies, the required thermal comfort in buildings can often not be maintained, particularly if the internal heat sources are suddenly changed. This paper shows measurement results and evaluations of the operation of a novel adaptive and predictive calculation method, based on a multiple linear regression (AMLR) for the control of TABS. The measurement results are compared with the standard TABS strategy. The results show that the electrical pump energy could be reduced by more than 86%. Including the weather adjustment, it could be demonstrated that thermal energy savings of over 41% could be reached. In addition, the thermal comfort could be improved due to the possibility to specify mean room set-point temperatures. With the AMLR, comfort category I of the comfort norms ISO 7730 and DIN EN 15251 are observed in about 95% of occasions. With the standard TABS strategy, only about 24% are within category I.
Adaptive predictive control of thermo-active building systems (TABS) based on a multiple regression algorithm: First practical test. Available from: https://www.researchgate.net/publication/305903009_Adaptive_predictive_control_of_thermo-active_building_systems_TABS_based_on_a_multiple_regression_algorithm_First_practical_test [accessed Jul 7, 2017].
Am 1. Juli 2022 trafen sich im Rahmen des Abschlusskolloquiums des Projekts ACA-Modes rund 60 Teilnehmende aus Forschung, Lehre und Industrie zu einer internationalen Konferenz an der Hochschule Offenburg. Hier wurden die Projektergebnisse rund um die erfolgreiche Implementierung modellprädiktiver Regelstrategien vorgestellt, aktuelle Fragestellungen diskutiert und Entwicklungspfade hin zu einem netzdienlichen Betrieb von Energieverbundsystemen skizziert.