Refine
Document Type
- Conference Proceeding (15)
- Article (reviewed) (7)
- Patent (3)
- Report (3)
- Article (unreviewed) (1)
Conference Type
- Konferenz-Abstract (14)
- Konferenzartikel (1)
Has Fulltext
- no (29) (remove)
Is part of the Bibliography
- yes (29)
Keywords
- Brennstoffzelle (2)
- Lithiumbatterie (2)
- Ageing (1)
- Akkumulator (1)
- Electrochemistry (1)
- Elektrischer Energiespeicher (1)
- Karbon (1)
- Lithium (1)
- Lithium-Ionen-Batterie (1)
- Lithium-ion battery (1)
Institute
Open Access
- Open Access (29) (remove)
Electrochemical impedance spectroscopy (EIS) is a widely-used diagnostic technique to characterize electrochemical processes. It is based on the dynamic analysis of two electrical observables, that is, current and voltage. Electrochemical cells with gaseous reactants or products (e.g., fuel cells, metal/air cells, electrolyzers) offer an additional observable, that is, the gas pressure. The dynamic coupling of current and/or voltage with gas pressure gives rise to a number of additional impedance definitions, for which we have introduced the term electrochemical pressure impedance spectroscopy (EPIS) [1,2]. EPIS shows a particular sensitivity towards transport processes of gas-phase or dissolved species, in particular, diffusion coefficients and transport pathway lengths. It is as such complementary to standard EIS, which is mainly sensitive towards electrochemical processes. This sensitivity can be exploited for model parameterization and validation. A general analysis of EPIS is presented, which shows the necessity of model-based interpretation of the complex EPIS shapes in the Nyquist plot (cf. Figure). We then present EPIS simulations for two different electrochemical cells: (1) a sodium/oxygen battery cell and (2) a hydrogen/air fuel cell. We use 1D or 2D electrochemical and transport models to simulate current excitation/pressure detection or pressure excitation/voltage detection. The results are compared to first EPIS experimental data available in literature [2,3].
Ziel der Investitionsmaßnahme Enerlab 4.0 war die Bereitstellung einer umfangreichen in-operando und post-mortem Diagnostik für dezentrale Energieerzeuger und -Speicher, z. B. Batteriezellen und Photovoltaikzellen. Diese sind wichtige Komponenten für verschiedene Bereiche der Industrie 4.0 – von autonomen Sensoren über energieautarke Produktion bis hin zur Qualitätskontrolle. Zu diesem Zweck wurde die apparative Ausstattung der Hochschule Offenburg erweitert, und zwar sowohl für in-operando Diagnostik (elektrische Zyklierer, Impedanzspektrometer, Temperaturprüfschränke) als auch für post-mortem Diagnostik (Glovebox, Probenpräparationen für vorhandene Werkstoffanalytik und chemische Analytik). Be-reits vorhandene Geräte aus anderen laufenden oder abgeschlossenen Projekten wurden in die neue Infrastruktur integriert. Im Ergebnis entstand ein modernes und leistungsfähiges Batterie- und Photovoltaiklabor, welches in zahlreichen laufenden und neuen Vorhaben genutzt wird.
Lithium-ion pouch cells with lithium titanate (Li4Ti5O12, LTO) anode and lithium nickel cobalt aluminum oxide (LiNi0.8Co0.15Al0.05O2, NCA) cathode were investigated experimentally with respect to their electrical (0.1C…4C), thermal (5 °C…50 °C) and long-time cycling behavior. The 16 Ah cell exhibits an asymmetric charge/discharge behavior which leads to a strong capacity-rate effect, as well as a significantly temperature-dependent capacity (0.37 Ah ∙ K−1) which expresses as additional high-temperature feature in the differential voltage plot. The cell was cycled for 10,000 cycles inbetween the nominal voltage limits (1.7–2.7 V) with a symmetric 4C constant-current charge/discharge protocol, corresponding to approx. 3400 equivalent full cycles. A small (0.192 mΩ/1000 cycles) but continuous increase of internal resistance was observed. Using electrochemical impedance spectroscopy (EIS), this could be identified to be caused by the NCA cathode, while the LTO anode showed only minor changes during cycling. The temperature-corrected capacity during 4C cycling exhibited a decrease of 1.28%/1000 cycles. The 1C discharge capacity faded by only 4.0% for CC discharge and 2.3% for CCCV discharge after 10,000 cycles. The cell thus exhibits very good internal-resistance stability and excellent capacity retention even under harsh (4C continuous) cycling, demonstrating the excellent stability of LTO as anode material.
Ziel des LiBaLu-Teilprojekts Modellierung und Simulation war die Unterstützung der Elektroden- und Zellentwicklung mit Hilfe umfangreicher Computersimulationen im Sinne des computergestützten Engineering (CAE). Zwei verschiedene Schwerpunkte standen im Mittelpunkt der Untersuchungen. Zum einen wurde das mechanistische Verständnis der komplexen Elektrochemie in Lithium-Luftbatterien durch mikrokinetische Modelle aufgeklärt. Auf Basis von postulierten Mehrschrittmechanismen wurden makroskopische Eigenschaften (Entlade-/Ladekennlinien, Zyklovoltammogramme) vorhergesagt und mit experimentellen Daten der Projektpartner verglichen. Zum anderen wurde das Design der Prototypzelle mit Hilfe numerischer Simulationen untersucht und optimiert. So konnten z. B. optimale Schichtdicken oder die Rolle von Gastransportlimitierungen identifiziert werden.
One of the bottlenecks hindering the usage of polymer electrolyte membrane fuel cell technology in automotive applications is the highly load-sensitive degradation of the cell components. The cell failure cases reported in the literature show localized cell component degradation, mainly caused by flow-field dependent non-uniform distribution of reactants. The existing methodologies for diagnostics of localized cell failure are either invasive or require sophisticated and expensive apparatus. In this study, with the help of a multiscale simulation framework, a single polymer electrolyte membrane fuel cell (PEMFC) model is exposed to a standardized drive cycle provided by a system model of a fuel cell car. A 2D multiphysics model of the PEMFC is used to investigate catalyst degradation due to spatio-temporal variations in the fuel cell state variables under the highly transient load cycles. A three-step (extraction, oxidation, and dissolution) model of platinum loss in the cathode catalyst layer is used to investigate the cell performance degradation due to the consequent reduction in the electro-chemical active surface area (ECSA). By using a time-upscaling methodology, we present a comparative prediction of cell end-of-life (EOL) under different driving behavior of New European Driving Cycle (NEDC) and Worldwide Harmonized Light Vehicles Test Cycle (WLTC).
The invention relates to a method and to a device for determining the state of charge (SOC) of a rechargeable battery (106) of a specified battery type or a parameter physically related thereto, in particular a remaining charge amount Q contained in the battery, the method operating by means of a voltage-controlled battery model (102), which is parameterized for the battery (106) in question or a corresponding battery type. It is merely necessary to measure the battery voltage Umess and to provide said battery voltage to the battery model (102) as an input variable. The invention further relates to a method and to a device for determining the state of health (SOH) of a battery (102), wherein the battery model (102) also used to determine the SOC provides a modeled battery current Imod. Modeled charge amounts during charging and discharging phases of the battery (106) can be determined from said modeled battery current and can be compared with measured charge amounts, which are determined from the measured battery current Imess. Because the battery model (102) does not age, the SOH of the battery can thereby be determined.