Refine
Document Type
Conference Type
- Konferenzartikel (2)
Has Fulltext
- no (10) (remove)
Is part of the Bibliography
- yes (10)
Keywords
- HPTLC (2)
- Aflatoxin (1)
- Dünnschichtchromatographie (1)
- Ergänzung (1)
- Faseroptik (1)
- Gasanalyse (1)
- Glucosamin (1)
- Melamin (1)
- Milch (1)
- Nahrung (1)
Institute
Open Access
- Open Access (10) (remove)
HPTLC on amino plates, with simple heating of the plates for derivatization, has been used for quantification of glucosamine in nutritional supplements. On heating the plate glucosamine reacts to form a compound which strongly absorbs light between 305 and 330 nm, with weak fluorescence. The reaction product can be detected sensitively either by absorption of light or by fluorescence detection. The detection limit in absorption mode is approximately 25 ng per spot. In fluorescence mode a detection limit of 15 ng is achievable. A calibration plot for absorption detection is linear in the range 25 to 4000 ng glucosamine. The derivative formed from glucosamine by heating is stable for months, and the relative standard deviation is 1.64% for 600 ng glucosamine. The amounts of glucosamine found in nutritional supplements were in agreement with the label declarations.
A Validated Quantification of Sudan Red Dyes in Spicery using TLC and a 16-bit Flatbed Scanner
(2018)
We present a video-densitometric quantification method for Sudan red dyes in spices and spice mixtures, separated by TLC. Application was done band-wise in small dots using a 5 μL glass pipette. For separation, the RP-18 plates (20 × 20 cm with fluorescent dye; Merck, Germany, 1.05559) were developed in a vertical developing chamber without vapor saturation from the starting point to a distance of 70 mm by using acetonitrile, methanol, and aqueous ammonia solution (25%; 8 + 1.8 + 0.2, v/v) as mobile phase. The quantification is based on direct measurements using an inexpensive 16-bit flatbed scanner for color measurements (in red, green, and blue). Evaluation of only the green channel makes the measurements very specific. For linearization, an extended Kubelka-Munk expression for data transformation was used. The range of linearity covers more than two magnitudes and lies between 20 and 500 ng. The extraction from a 2 g sample with acetonitrile, evaporation, and reconstitution to 200 μL with methanol and the band-wise application (7 mm) of a 10 μL sample allows a statistically defined LOD of less than 500 ppb of Sudan red dyes. To perform the analysis, a separation chamber, RP-18 plates, 5 μL glass pipettes, and a 16-bit flatbed scanner for 105 € are needed; therefore, the separation method is inexpensive, fast, and reliable.
Thin-layer chromatography is a rapid and reliable working method for quantification of mycotoxins which is suitable for checking EC legislation aflatoxin limits for dried figs without an RP-18 pre-column cleaning step. We describe normal-phase chromatography on silica gel plates with 2.4:0.05:0.1:0.05 ( v/v ) methyl t -butyl ether-water-methanol-cyclohexane as mobile phase and reversed-phase chromatography on RP-18 plates with methanol-4% aqueous ZnSO 4 solution-ethyl methyl ketone 15:15:3 ( v/v ) as mobile phase. Sample pretreatment was by modified QuEChERS (Quick, Easy, Cheap, Effective, Rugged, Safe) extraction with tetrahydrofuran or acetone. NaCl was used as QuEChERS salt. Response was a linear function of amount chromatographed in the ranges 3 to 100 pg per zone for aflatoxins B 2 and G 2 , 10 to 350 pg per zone for the aflatoxins B 1 and G 1 , and 0.25 to 2.5 ng per zone for ochratoxin A. Quantification limits for the aflatoxins were between 13 and 35 pg per zone (equivalent to 1.5 and 2.4 ppb, taking the pre-treatment procedure into account). Ochratoxin A was detectable with a limit of quantification of 970 pg per zone, corresponding to 56 ppb in the sample. Normal phase and RP-18 separations work rapidly, reliably, and at low cost. They are also suitable for checking the content of the mycotoxins patulin, penicillic acid, zearalenone, and deoxynivalenol.
Die Weltwirtschaftskrise 2008 hat mit ihrer zeitweisen Verknappung von Acetonitril eindringlich gezeigt, dass man nicht nur auf eine einzige chromatographische Methode setzten sollte. Genau dies wird aber im Augenblick getan, denn Industrie und Forschung setzen mehrheitlich auf die High Performance Liquid Chromatography (HPLC) als die Trennmethode ihrer Wahl. Für viele Anwendungen in der Pharmazie, in der Umweltanalytik, der Lebensmittelanalytik, aber auch in der Inprozesskontrolle gibt es mit der Dünnschichtchromatografie eine Alternative.
The identification and quantification of compounds in the gas phase becomes of increasing interest in the context of environmental protection, as well as in the analytical field. In this respect, the high extinction coefficients of vapours and gases in the ultraviolet wavelength region allow a very sensitive measurement system. In addition, the increased performance of the components necessary for setting up a measurement system, such as fibres, light sources and detectors has been improved. In particular the light sources and detectors offer improved stability, and the deep UV performance and solarisation resistance of fused silica fibres allow have been significantly optimized in the past years. Therefore a compact and reliable detection system with high measuring accuracy is developed. Within this paper possible applications of the system under development and recent results will be discussed.
Two solvent mixtures for high-performance thin-layer chromatographic (HPTLC) separation of some compounds showing estrogenic activity in the yeast estrogen screen (YES) assay are presented. The new method, planar yeast estrogen screen (pYES) combines the YES assay and a chromatographic separation on silica gel HPTLC plates with the performance of the YES assay. For separation, the analytes were applied bandwise to HPTLC plates (10 × 20 cm) with fluorescent dye (Merck, Germany). The plates were developed in a vertical developing chamber after 30 min of chamber saturation over a separation distance of 70 mm, using cyclohexane‒methyl-ethyl ketone (2:1, V/V) or cyclohexane‒CPME (3:2, V/V) as solvents. Both solvents allow separation of estriol, daidzein, genistein, 17β-estradiol, 17α-ethinyl estradiol, estrone, 4-nonylphenol and bis(2-ethylhexyl) phthalate.
High-performance thin-layer chromatography (HPTLC), as the modern form of TLC (thin-layer chromatography), is suitable for detecting pharmaceutically active compounds over a wide polarity range using the gradient multiple development (GMD) technique. Diode-array detection (DAD) in conjunction with HPTLC can simultaneously acquire ultraviolet‒visible (UV‒VIS) and fluorescence spectra directly from the plate. Visualization as a contour plot helps to identify separated zones. An orange peel extract is used as an example to show how GMD‒DAD‒HPTLC in seven different developments with seven different solvents can provide an overview of the entire sample. More than 50 compounds in the extract can be separated on a 6-cm HPTLC plate. Such separations take place in the biologically inert stationary phase of HPTLC, making it a suitable method for effect-directed analysis (EDA). HPTLC‒EDA can even be performed with living organism, as confirmed by the use of Aliivibrio fischeri bacteria to detect bioluminescence as a measure of toxicity. The combining of gradient multiple development planar chromatography with diode-array detection and effect-directed analysis (GMD‒DAD‒HPTLC‒EDA) in conjunction with specific staining methods and time-of-flight mass spectrometry (TOF‒MS) will be the method of choice to find new chemical structures from plant extracts that can serve as the basic structure for new pharmaceutically active compounds.
Alle Materie strebt nach maximaler Unordnung. Diese Erkenntnis wird durch die thermodynamische Funktion der Entropie beschrieben. Auch bei jeglicher Art menschlichen Handelns wird die Entropie immer erhöht. Wird in der Technik Materie in geordnete Formen gebracht (z. B. beim Herstellen von Pfandflaschen), findet in diesem Produkt eine Entropieerniedrigung statt. Gleichzeitig wird aber an anderer Stelle die Unordnung beträchtlich vergrößert. Diese Entropieerhöhung nennen wir Abfall. Jede Entropieerhöhung ist mit dem Verbrauch wertvoller Ressourcen verbunden. Durch eine optimale Recyclingtechnik kann einer Entropieerhöhung von Materie entgegengearbeitet werden. Aber nur Recyclingraten von über 90 % erlauben eine wirksame Streckung der Ressourcen.