The Metering Bus, also known as M-Bus, is a European standard EN13757-3 for reading out metering devices, like electricity, water, gas, or heat meters. Although real-life M-Bus networks can reach a significant size and complexity, only very simple protocol analyzers are available to observe and maintain such networks. In order to provide developers and installers with the ability to analyze the real bus signals easily, a web-based monitoring tool for the M-Bus has been designed and implemented. Combined with a physical bus interface it allows for measuring and recording the bus signals. For this at first a circuit has been developed, which transforms the voltage and current-modulated M-Bus signals to a voltage signal that can be read by a standard ADC and processed by an MCU. The bus signals and packets are displayed using a web server, which analyzes and classifies the frame fragments. As an additional feature an oscilloscope functionality is included in order to visualize the physical signal on the bus. This paper describes the development of the read-out circuit for the Wired M-Bus and the data recovery.
Die immer weitreichenderen Anwendungen des Smart Metering und des Smart Grid stellen immer höhere Anforderungen an Kommunikationstechnologien, die die Zielkonflikte aus Echtzeitfähige, Stabilität, Kosten und Energieeffizienz möglichst anwendungsoptimiert und auf einem immer höheren Niveau lösen. Insbesondere im Bereich der so genannten Primärkommunikation zwischen einem Sensor- oder Aktorknoten und einem Datensammler mit Gatewayfunktionalität konnten in den vergangenen Jahren wesentliche Fortschritte erzielt werden. Zu nennen sind hierbei insbesondere die Aktivitäten der ZigBee Alliance rund um den offenen Spezifikationsprozess des ZigBee Smart Energy Profiles (SEP) und der OMS-Gruppe beim ZVEI, die auf dem Wireless M-Bus nach EN13757-4 aufbauen, der sich seinerseits lebhaft und zielgerichtet weiter entwickelt. Der Beitrag diskutiert die vorhandenen Einschränkungen und die verfügbaren Lösungsansätze. Er illustriert diese anhand einiger öffentlich geförderter Projekte, an denen das Team des Autors beteiligt ist.
Automated RF Emulator for a Highly Scalable IEEE802.11p Communication and Localization Subsystem
(2014)
The IEEE802.11p standard describes a protocol for car-to-X and mainly for car-to-car-communication. In the research project Ko-TAG, which is part of the research initiative Ko-FAS, cooperative sensor technology is developed for the support of highly autonomous driving. The Ko-TAG subsystem improves the real-time characteristics of IEEE802.11p needed for precise time of flight real-time localization while still fitting into the regulatory schemes. A secondary radar principle based on communication signals enables localization of objects with simultaneous data transmission. The Ko-TAG subsystem mainly concentrates on the support of traffic safety applications in intra-urban scenarios. This paper details on the development of a fully automated RF emulator used to test the Ko-TAG subsystem.
The RF emulator includes the physical networking nodes, but models the RF environment using RF-waveguides. The RF emulator allows the controlling of path loss and connectivity between any of the nodes with the help of RF attenuators and programmable RF switches, while it is shielded against its surrounding RF environment in the lab. Therefore it is an inexpensive alternative to an RF absorber chamber, which often is not available or exceeds the project’s budget.
Details about the system definition can be found in earlier papers. Test results are shown in the last part of the paper.
In dem Maße, in dem sich die industrielle Automatisierung verändert, verändern sich auch die Anforderungen an die Sicherheit. Neben der funktionalen Sicherheit rückt dabei immer mehr die Datensicherheit in den Mittelpunkt. Als „best practice“ bietet es sich an, bewährte Sicherungstechniken aus der IT auch in der industriellen Kommunikation einzusetzen.
This paper presents the elements and the results from the European research project inCASA (Integrated Network for Completely Assisted Senior Citizen’s Autonomy), which designed and implemented a seamless integration of heterogeneous systems and network protocols for regionally distributed telecare and telehealth applications. The integration includes a multitude of physical interface, the transcoding of data models using embedded middleware, and a backend system with open interfaces. The implementation was verified in field tests in five European countries.
In the last decade, IPv6 over Low power Wireless Personal Area Networks, also known as 6LoWPAN, has well evolved as a primary contender for short range wireless communication and holds the promise of an Internet of Things, which is completely based on the Internet Protocol. In the meantime, various 6LoWPAN implementations are available, be it open source or commercial. One of these implementations, which was developed by the authors' team, was tested on an Automated Physical Testbed for Wireless Systems at the Laboratory Embedded Systems and Communication Electronics of Offenburg University of Applied Sciences, which allows the flexible setup and full control of arbitrary topologies. It also supports time-varying topologies and thus helps to measure performance of the RPL implementation. The results of the measurements show a very good stability and short-term and long-term performance also under dynamic conditions. In addition, it can be proven that the performance predictions from other papers are consistent with real-life implementations.
Temperature regulation is an important component for modern high performance single -core and multi-core processors. Especially high operating frequencies and architectures with an increasing number of monolithically integrated transistors result in a high power dissipation and - since processor chips convert the consumed electrical energy into thermal energy - in high operating temperatures. High operating temperatures of processors can have drastic consequences regarding chip reliability, processor performance, and leakage currents. External components like fans or heat spreaders can help to reduce the processor temperature - with the disadvantage of additional costs and reduced reliability. Therefore, software based algorithms for dynamic temperature management are an attractive alternative and well known as Dynamic Thermal Management (DTM). However, the existing approaches for DTM are not taking into account the requirements of real-time embedded computing, which is the objective in the given project. The first steps are the profiling and the thermal modeling of the system, which is reported in this paper for a Freescale i. MX6Q quad-core microprocessor. An analytical model is developed and verified by an extensive set of measurement runs.
WirelessHART protocol was specifically designed for real-time communication in the wireless sensor networks domain for industrial process automation requirements. Whereas the major purpose of WirelessHART is the read-out of sensors with moderate real-time requirements, an increasing demand for integration of actuator applications can be observed. Therefore, it must be verified that the WirelessHART protocol gives sufficient support to real-time industry requirements. As a result, the delay of especially burst and command messages from actuator and sensor nodes to the gateway and vice versa must be analyzed. In this paper, we implemented a WirelessHART network scenario in WirelessHART simulator in NS-2 [8], simulated and analyzed its time characteristics under ideal and noisy conditions. We evaluated the performance of the implementation in order to verify whether the requirements of industrial process and control can be met. This implementation offers an early alternative to expensive test beds for WirelessHART in real-time actuator applications.
Efficient, secure and reliable communication is a major precondition for powerful applications in smart metering and smart grid. This especially holds true for the so called primary communication in the Local Metrological Network (LMN) between meter and data collector, as the LMN comes with the most stringent requirements with regard to cost, range, as well as bandwidth and energy efficiency. Until today, LMN field tests are operated all over the world. In these installations, however, energy autarkic systems play a marginal role. This contribution describes the results of the framework 7 (FP 7) WiMBex project (“Remote wireless water meter reading solution based on the EN 13757 standard, providing high autonomy, interoperability and range”). In this project an energy autarkic water meter was developed and tested, which follows the specification of the Wireless M-Bus protocol (EN 13757). The complete system development covers the PCB with the RF transceiver and the microcontroller, the energy converter and storage, and the software with the protocol. This contribution especially concentrates on the design, the development and the verification of the routing protocol. The routing protocol is based on the Q mode of EN13757-5 (Wireless M-Bus) and was extended by an additional energy state related parameter. This extension is orthogonal to the existing protocol and considers both the charge level and the charge characteristics (rate of occurrences, intensity). The software was implemented in NesC under the operating system TinyOS. The system was verified in an automated test bed and in field tests in UK and Ireland.