A Validated Quantification of Sudan Red Dyes in Spicery using TLC and a 16-bit Flatbed Scanner
(2018)
We present a video-densitometric quantification method for Sudan red dyes in spices and spice mixtures, separated by TLC. Application was done band-wise in small dots using a 5 μL glass pipette. For separation, the RP-18 plates (20 × 20 cm with fluorescent dye; Merck, Germany, 1.05559) were developed in a vertical developing chamber without vapor saturation from the starting point to a distance of 70 mm by using acetonitrile, methanol, and aqueous ammonia solution (25%; 8 + 1.8 + 0.2, v/v) as mobile phase. The quantification is based on direct measurements using an inexpensive 16-bit flatbed scanner for color measurements (in red, green, and blue). Evaluation of only the green channel makes the measurements very specific. For linearization, an extended Kubelka-Munk expression for data transformation was used. The range of linearity covers more than two magnitudes and lies between 20 and 500 ng. The extraction from a 2 g sample with acetonitrile, evaporation, and reconstitution to 200 μL with methanol and the band-wise application (7 mm) of a 10 μL sample allows a statistically defined LOD of less than 500 ppb of Sudan red dyes. To perform the analysis, a separation chamber, RP-18 plates, 5 μL glass pipettes, and a 16-bit flatbed scanner for 105 € are needed; therefore, the separation method is inexpensive, fast, and reliable.
Phenolic compounds, such as flavonoids and phenolic acids, are very important substances that occur in various medicinal plants. They show different pharmacological activities which might be useful in the therapy of many diseases. Phenolic compounds have achieved an increasing interest over the last years because these compounds are easily oxidized and, thus, act as strong antioxidants. We present the chemiluminescence of different phenolic compounds measured directly on high-performance thin-layer chromatography LiChrospher® plates using the oxalic acid derivative bis(2,4,6-trichlorophenyl) oxalate (TCPO) in conjunction with H2O2. Our results indicate that chemiluminescence intensity increases with an ascending number of phenolic groups in the molecule. The method can be used to detect phenolic compounds in beverages like coffee, tea, and wine.
Limits of quantification of some neonicotinoid insecticides measured by thin-layer chromatography
(2012)
A simple method to quantify the neonicotinoid insecticides nitenpyram, thiamethoxam, acetamiprid, imidacloprid, thiacloprid and clothianidin directly on an HPTLC-plate is presented. As stationary phase silica gel 60 RP-18WF254 s plates were used and a mixture of methyl-t-butyl ether, 2-butanone, NH3 (25%) (5 + 2+0.1, v/v) was used as solvent. All neonicotinoid insecticides show light absorptions below 300 nm. The calculated limits of quantification (LOQ) by UV-detection are in the range from 12 ng to 26 ng on plate depending on the different insecticides.Nitenpyram can be stained using fast blue salt B, forming red zones. The observed LOQ is 25 ng on plate. Acetamiprid can be specifically stained using phenylglyoxylic acid forming a yellow/green fluorescent compound. The LOQ is 52 ng per spot.The compounds thiamethoxam, acetamiprid, thiacloprid and clothianidin can be transformed into blue fluorescing zones, using a relatively new staining solution. This consists of tetraphenylborate and HCl. This is the first publication mentioning that neonicotinoids undergo this reaction. The calculated limits of quantification are in the range from 10 ng to 27 ng on plate.A simple pre-treatment procedure using an acetonitrile extraction and a Chromabond SiOH clean up procedure leads to overall LOQs for bee samples of 48 to 108 µg/Kg. The method can be used to measure neonicotinoid contaminations of bees.