Refine
Year of publication
Document Type
- Conference Proceeding (24)
- Contribution to a Periodical (22)
- Part of a Book (19)
- Article (unreviewed) (15)
- Article (reviewed) (12)
- Report (11)
- Book (9)
- Study Thesis (1)
Conference Type
- Konferenzartikel (21)
- Sonstiges (2)
- Konferenz-Abstract (1)
Is part of the Bibliography
- yes (113)
Keywords
- Energieversorgung (6)
- Haustechnik (5)
- Regelungstechnik (5)
- Gebäudeklimatisierung (4)
- TABS (4)
- Energiemanagement (3)
- Energietechnik (3)
- Fotovoltaik (3)
- MPC (3)
- Monitoring (3)
Institute
- Fakultät Maschinenbau und Verfahrenstechnik (M+V) (96)
- INES - Institut für nachhaltige Energiesysteme (32)
- Zentrale Einrichtungen (8)
- CRT - Campus Research & Transfer (5)
- Fakultät Elektrotechnik und Informationstechnik (E+I) (bis 03/2019) (3)
- Fakultät Elektrotechnik, Medizintechnik und Informatik (EMI) (ab 04/2019) (1)
- Fakultät Medien und Informationswesen (M+I) (bis 21.04.2021) (1)
Open Access
- Open Access (40)
- Closed Access (38)
- Bronze (10)
- Closed (5)
- Gold (2)
There is a growing trend for the use of thermo-active building systems (TABS) for the heating and cooling of buildings, because these systems are known to be very economical and efficient. However, their control is complicated due to the large thermal inertia, and their parameterization is time-consuming. With conventional TABS-control strategies, the required thermal comfort in buildings can often not be maintained, particularly if the internal heat sources are suddenly changed. This paper shows measurement results and evaluations of the operation of a novel adaptive and predictive calculation method, based on a multiple linear regression (AMLR) for the control of TABS. The measurement results are compared with the standard TABS strategy. The results show that the electrical pump energy could be reduced by more than 86%. Including the weather adjustment, it could be demonstrated that thermal energy savings of over 41% could be reached. In addition, the thermal comfort could be improved due to the possibility to specify mean room set-point temperatures. With the AMLR, comfort category I of the comfort norms ISO 7730 and DIN EN 15251 are observed in about 95% of occasions. With the standard TABS strategy, only about 24% are within category I.
Adaptive predictive control of thermo-active building systems (TABS) based on a multiple regression algorithm: First practical test. Available from: https://www.researchgate.net/publication/305903009_Adaptive_predictive_control_of_thermo-active_building_systems_TABS_based_on_a_multiple_regression_algorithm_First_practical_test [accessed Jul 7, 2017].
The uncertain and time-variant nature of renewable energy results in the need to deal with peaks in the production of energy. One approach is to achieve a load shift and thereby help balancing the grid by using thermally Activated Building Systems (TABS). Control systems currently in place do not exploit the full potential of TABS. This paper reviews how Model Predictive Control can possibly reduce the fluctuations of the demand and supply of (renewable) energy as it enables the TABS to react to the dynamics of weather and its impact on the grid at any time.
Solartechnik
(2022)
Die Erde ist ein Empfänger für kosmische Strahlungen. Sie empfängt nur einen winzigen Bruchteil der von der Sonne ausgesendeten elektromagnetischen Strahlung. Dieser Bruchteil ist im Wesentlichen bestimmt durch den Abstand zwischen Sonne und Erde und durch das Verhältnis der Durchmesser von Erde und Sonne. Außerhalb der Erdatmosphäre, also extraterrestrisch, werden vom World Radiation Center WRC je Quadratmeter horizontaler Empfängerfläche 1,367 kW/m2 ± 1 % konstant über das gesamte Jahr gemessen.
An energy oriented design concept was developed within the research project PHOTOPUR which has the development of a PV powered water cleaning system as main focus. During a wine season Plant Protection Products (PPP) are several times sprayed on plants to protect them of undesired insects and herbs or avoid hazardous fungus
types. A work package of the project partner INES in Offenburg led to a design introducing energy profiling already in the early beginning of a product design. The concept is based on three pillars respecting first the
requirements of the core process making up filtering and cleaning and secondary aspects which run, support, maintain and monitor the system to secure availability and product reliability.
The presented paper shows that the results of the design tools guided the developers to assemble a functional model of the water decontamination unit which was manually tested with its concatenated steps of the water cleaning process.
Sustainable Aspects force a building manager to continuous observation of actual states and developments concerning building use, energy and media flows.In the presented approach a communication structure was built up to use different software applications and tools in order to optimize the operation of the building.
In this study, a high-performance controller is proposed for single-phase grid-tied energy storage systems (ESSs). To control power factor and current harmonics and manage time-shifting of energy, the ESS is required to have low steady-state error and fast transient response. It is well known that fast controllers often lack the required steady-state accuracy and trade-off is inevitable. A hybrid control system is therefore presented that combines a simple yet fast proportional derivative controller with a repetitive controller which is a type of learning controller with small steady-state error, suitable for applications with periodic grid current harmonic waveforms. This results in an improved system with distortion-free, high power factor grid current. The proposed controller model is developed and design parameters are presented. The stability analysis for the proposed system is provided and the theoretical analysis is verified through stability, transient and steady-state simulations.
Dieses Fachbuch gibt einen vertieften Einblick in das dynamische Verhalten von thermoaktiven Bauteilsystemen. Es wird eine neu entwickelte und vielfach erprobte, selbstlernende und vorausschauende TABS-Steuerung vorgestellt. Dazu wird auf die Erfordernisse einer effektiven TABS-Steuerung eingegangen und die Grundlagen und Funktionsweise der neu entwickelten AMLR-Steuerung erläutert. Anhand mehrerer Anwendungsbeispiele wird die Umsetzung in die bauliche Praxis erläutert und mit Hilfe von umfangreichen Messergebnissen die Funktion der neuen AMLR-Steuerung nachgewiesen. Abschließend werden Empfehlungen für die Anwendung von AMLR in der baulichen TABS-Praxis hinsichtlich Anlagenhydraulik und Umsetzung in der Gebäudeautomation gegeben.
Energiemanagement im Betrieb
(2021)
Über zwei Jahrzehnte hat sich an der Hochschule Offenburg im Umfeld von Professor Elmar Bollin eine Forschungsgruppe etabliert, die die Bereiche Gebäudeautomation und nachhaltige Energietechnik zusammenführten. Anfänglich ging es darum die Potenziale der internetbasierten Wetterprognostik und modell-basierten Anlagensteuerung für die Verbesserung des Komforts und der Energieeffizienz im Gebäude zu nutzen. Im Rahmen von Forschungs- und Entwicklungsarbeiten mit Einsatz von dynamischen Gebäudesimulationen konnte schließlich ein Algorithmus gefunden werden, der es ermöglichte auf Basis von prognostizierter Außentemperatur und Sonneneinstrahlung den Energiebedarf eines Bürogebäudes für den Folgetag vorherzusagen. In Verbindung mit der Gebäudeautomation entstand so die adaptive und prädiktive TABS-Steuerung AMLR.
Über zwei Jahrzehnte hat sich an der Hochschule Offenburg eine Forschungsgruppe etabliert, die die beiden Bereiche Gebäudeautomation und nachhaltige Energietechnik zusammenführte. Anfangs ging es darum, Potentiale der internetbasierten Wetterprognostik und modell-basierten Anlagensteuerung für die Verbesserung des Komforts und der Energieeffizienz im Gebäude zu nutzen. Im Rahmen von Forschungs- und Entwicklungsarbeiten mit Einsatz von dynamischen Gebäudesimulationen konnte ein Algorithmus gefunden werden, der es ermöglichte auf Basis von prognostizierter Außentemperatur und Sonneneinstrahlung den Energiebedarf eines Bürogebäudes für den Folgetag vorherzusagen. In Verbindung mit der Gebäudeautomation entstand so die adaptive und prädiktive TABS-Steuerung AMLR.
In Solarthermie-2000, Teilprogramm 2 soll anhand von Beispiellösungen für größere solarthermische Anlagen mit einer Mindestkollektorfläche von 100 m² an unterschiedlich genutzten Gebäuden nachgewiesen werden, dass im Bereich der thermischen Solarenergienutzung technisch gute Lösungen zur Verfügung gestellt werden können. Diese Systemlösungen sollen weiter verbessert und angepasst werden. Zugleich soll erreicht werden, dass die wirtschaftliche Konkurrenzfähigkeit gesteigert wird, indem durch Reduzierung der spezifischen Systemkosten und Erhöhung des spezifischen Nutzenergieertrages die solaren Nutzwärmekosten gesenkt werden.