Refine
Document Type
- Article (reviewed) (12) (remove)
Language
- English (12)
Is part of the Bibliography
- yes (12)
Keywords
- Haustechnik (3)
- Algorithmus (2)
- Fotovoltaik (2)
- MPC (2)
- Adaptive predictive control (1)
- Batterie (1)
- Battery energy management system (1)
- Building automation system (1)
- Controlling (1)
- Demand Side Management (1)
- Edge control (1)
- Energieversorgung (1)
- Grid (1)
- Lineare Regression (1)
- Multiple regression (1)
- Netzwerk (1)
- Photovoltaic (1)
- Photovoltaics (1)
- Predictive Management (1)
- Rückfluss (1)
- Smart Grid (1)
- Thermal Storage (1)
- Thermal comfort (1)
- Thermo-activate building system (TABS) (1)
- aging characteristics (1)
- edge computing (1)
- electric battery (1)
- energy management system (1)
- fuzzy logic (1)
- lithium iron phosphate (LFP) (1)
- lithium-ion battery (1)
- microgrid operation (1)
- photovoltaic (1)
- rural distribution grid (1)
- stationary electrical energy storage (1)
- thermally activated building systems (1)
Institute
Open Access
- Closed Access (7)
- Open Access (3)
- Gold (2)
Recently, photovoltaic (PV) with energy storage systems (ESS) have been widely adopted in buildings to overcome growing power demands and earn financial benefits. The overall energy cost can be optimized by combining a well-sized hybrid PV/ESS system with an efficient energy management system (EMS). Generally, EMS is implemented within the overall functions of the Building Automation System (BAS). However, due to its limited computing resources, BAS cannot handle complex algorithms that aim to optimize energy use in real-time under different operating conditions. Furthermore, islanding the building's local network to maximize the PV energy share represents a challenging task due to the potential technical risks. In this context, this article addresses an improved approach based on upgrading the BAS data analytics capability by means of an edge computing technology. The edge communicates with the BAS low-level controller using a serial communication protocol. Taking advantage of the high computing ability of the edge device, an optimization-based EMS of the PV/ESS hybrid system is implemented. Different testing scenarios have been carried out on a real prototype with different weather conditions, and the results show the implementation feasibility and technical performance of such advanced EMS for the management of building energy resources. It has also been proven to be feasible and advantageous to operate the local energy network in island mode while ensuring system safety. Additionally, an estimated energy saving improvement of 6.23 % has been achieved using optimization-based EMS compared to the classical rule-based EMS, with better ESS constraints fulfillment.
Building energy management systems (BEMSs), dedicated to sustainable buildings, may have additional duties, such as hosting efficient energy management systems (EMSs) algorithms. This duty can become crucial when operating renewable energy sources (RES) and eventual electric energy storage systems (ESSs). Sophisticated EMS approaches that aim to manage RES and ESSs in real time may need high computing capabilities that BEMSs typically cannot provide. This article addresses and validates a fuzzy logic-based EMS for the optimal management of photovoltaic (PV) systems with lead-acid ESSs using an edge computing technology. The proposed method is tested on a real smart grid prototype in comparison with a classical rule-based EMS for different weather conditions. The goal is to investigate the efficacy of islanding the building local network as a control command, along with ESS power control. The results show the implementation feasibility and performance of the fuzzy algorithm in the optimal management of ESSs in both operation modes: grid-connected and islanded modes.
Photovoltaics Energy Prediction Under Complex Conditions for a Predictive Energy Management System
(2015)
Demand Side Management for Thermally Activated Building Systems based on Multiple Linear Regression
(2015)
The significant market growth of stationary electrical energy storage systems both for private and commercial applications has raised the question of battery lifetime under practical operation conditions. Here, we present a study of two 8 kWh lithium-ion battery (LIB) systems, each equipped with 14 lithium iron phosphate/graphite (LFP) single cells in different cell configurations. One system was based on a standard configuration with cells connected in series, including a cell-balancing system and a 48 V inverter. The other system featured a novel configuration of two stacks with a parallel connection of seven cells each, no cell-balancing system, and a 4 V inverter. The two systems were operated as part of a microgrid both in continuous cycling mode between 30% and 100% state of charge, and in solar-storage mode with day–night cycling. The aging characteristics in terms of capacity loss and internal resistance change in the cells were determined by disassembling the systems for regular checkups and characterizing the individual cells under well-defined laboratory conditions. As a main result, the two systems showed cell-averaged capacity losses of 18.6% and 21.4% for the serial and parallel configurations, respectively, after 2.5 years of operation with 810 (serial operation) and 881 (parallel operation) cumulated equivalent full cycles. This is significantly higher than the aging of a reference single cell cycled under laboratory conditions at 20 °C, which showed a capacity loss of only 10% after 1000 continuous full cycles.
The building sector is one of the main consumers of energy. Therefore, heating and cooling concepts for renewable energy sources become increasingly important. For this purpose, low-temperature systems such as thermo-active building systems (TABS) are particularly suitable. This paper presents results of the use of a novel adaptive and predictive computation method, based on multiple linear regression (AMLR) for the control of TABS in a passive seminar building. Detailed comparisons are shown between the standard TABS and AMLR strategies over a period of nine months each. In addition to the reduction of thermal energy use by approx. 26% and a significant reduction of the TABS pump operation time, this paper focuses on investment savings in a passive seminar building through the use of the AMLR strategy. This includes the reduction of peak power of the chilled beams (auxiliary system) as well as a simplification of the TABS hydronic circuit and the saving of an external temperature sensor. The AMLR proves its practicality by learning from the historical building operation, by dealing with forecasting errors and it is easy to integrate into a building automation system.
In recent times, the energy consumed by buildings facilities became considerable. Efficient local energy management is vital to deal with building power demand penalties. This operation becomes complex when a hybrid energy system is included in the power system. This study proposes new energy management between photovoltaic (PV) system, Battery Energy Storage System (BESS) and the power network in a building by controlling the PV/BESS inverter. The strategy is based on explicit model predictive control (MPC) to find an optimal power flow in the building for one-day ahead. The control algorithm is based on a simple power flow equation and weather forecast. Then, a cost function is formulated and optimised using genetic algorithms-based solver. The objective is reducing the imported energy from the grid preventing the saturation and emptiness of BESS. Including other targets to the control policy as energy price dynamic and BESS degradation, MPC can optimise dramatically the efficacy of the global building power system. The strategy is implemented and tested successfully using MATLAB/SimPowerSystems software, compared to classical hysteresis management, MPC has given 10% in energy cost economy and 25% improvement in BESS lifetime.
In rural low voltage grid networks, the use of battery in the households with a grid connected Photovoltaic (PV) system is a popular solution to shave the peak PV feed-in to the grid. For a single electricity price scenario, the existing forecast based control approaches together with a decision based control layer uses weather and load forecast data for the on–off schedule of the battery operation. These approaches do bring cost benefit from the battery usage. In this paper, the focus is to develop a Model Predictive Control (MPC) to maximize the use of the battery and shave the peaks in the PV feed-in and the load demand. The solution of the MPC allows to keep the PV feed-in and the grid consumption profile as low and as smooth as possible. The paper presents the mathematical formulation of the optimal control problem along with the cost benefit analysis . The MPC implementation scheme in the laboratory and experiment results have also been presented. The results show that the MPC is able to track the deviation in the weather forecast and operate the battery by solving the optimal control problem to handle this deviation.